A microwave phase bridge technique for measuring the mutual coupling of identical coupled antennas.
Waveguide bridge technique for measuring phase of coupled signal between two loosely coupled antennas
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Waveguide bridge technique for measuring phase of coupled signal between two loosely coupled antennas
Explore the source record for details and available documents.
Estimates of total spacecraft weight and packaging options were made for three conceptual designs of a microwave radiometer spacecraft. Erectable structures were found to be slightly lighter than deployable structures but could be packaged in one-tenth the volume. The tension rim concept, an unconventional design approach, was found to be the lightest and transportable to orbit in the least number of shuttle flights.
A technique for measurement of individual hydrometeor absorption cross sections is presented. Cross sections are inferred by inserting the hydrometeor into a high Q resonant cavity and measuring the Q perturbation. Tests were conducted in a 10.64 GHz, TM(010) cavity. Absorption cross sections were measured at room temperature for 0.5 to 2.0 mm water drops, and were found to agree with the Rayleigh theory. Cross sections were also measured as a function of temperature, and from these the dielectric loss term lm(-K) was inferred for supercooled water down to -17 C.
Microwave and optical diagnostic techniques applied to high enthalpy shock tube and shock tunnel plasma flows
Techniques necessary to fabricate a high performance S-band microwave single source using state-of-the-art shallow bulk acoustic wave (SBAW) were explored. The bulk wave structures of the AlN/Al 2O3 were investigated for both the R plane and basal plane of sapphire. A 1.072 GHz SBAW delay line and oscillators were developed. A method of selecting and setting oscillator output frequency by selecting substrate orientation angle was also established.
Techniques for using combined image data from the Shuttle Imaging Radar (SIR-B) and the LANDSAT Thematic Mapper (TM) or Multispectral Scanner (MSS) for studies of irrigated crops, and boreal and deciduous forests are developed and evaluated. The effects of the structure and composition of crop canopies and soil surfaces on multiangle L-band HH (Horizontal polarization for transmission and reception) backscattering and on optical reflectance (in TM or MSS bands viewed at the nadir) are investigated. The relative accuracy of digital, calibrated SIR-B image data and LANDSAT TM or MSS image data is evaluated. Textural information extraction-techniques are developed for radar and optical image analysis.
An ultrafast microwave-assisted chemical insertion with magnesium acetate as the Mg-ion source and diethylene glycol as the reducing agent can be used to rapidly screen and identify potential hosts for Mg-ion batteries, without the necessity of fabricating electrodes and assembling electrochemical cells.
A technique is described which enables the large-signal current and voltage waveforms to be determined for a mixer diode. This technique is applicable to any configuration where the impedance seen by the diode at the local oscillator frequency and its harmonics is known.-
Not Available
The properties of materials can change dramatically at the nanoscale new and useful properties can emerge. An example is found in the paramagnetism in iron oxide magnetic nanoparticles. Using magnetically sensitive nitrogen-vacancy centers in diamond, we developed a platform to study electron spin resonance of nanoscale materials. To implement the platform, diamond substrates were prepared with nitrogen vacancy centers near the surface. Nanoparticles were placed on the surface using a drop casting technique. Using optical and microwave pulsing techniques, we demonstrated T1 relaxometry and double electron-electron resonance techniques for measuring the local electron spin resonance. The diamond NV platform developed in this project provides a combination of good magnetic field sensitivity and high spatial resolution and will be used for future investigations of nanomaterials and quantum materials.
Two simple microwave radar techniques that are potentially capable of providing routine satellite measurements of the directional spectrum of ocean waves were developed. One technique, the short pulse technique, makes use of very short pulses to resolve ocean surface wave contrast features in the range direction; the other technique, the two frequency correlation technique makes use of coherency in the transmitted waveform to detect the large ocean wave contrast modulation as a beat or mixing frequency in the power backscattered at two closely separated microwave frequencies. A frequency domain analysis of the short pulse and two frequency systems shows that the two measurement systems are essentially duals; they each operate on the generalized (three frequency) fourth-order statistical moment of the surface transfer function in different, but symmetrical ways, and they both measure the same directional contrast modulation spectrum. A three dimensional physical optics solution for the fourth-order moment was obtained for backscatter in the near vertical, specular regime, assuming Gaussian surface statistics.
The purpose of the Differential Microwave Radiometer (DMR) experiment on the Cosmic Background Explorer (COBE) satellite is to make whole-sky maps, at frequencies of 31.5, 53, and 90 GHz, of any departures of the Cosmic Microwave Background (CMB) from its mean value of 2.735 K. An elaborate software system is necessary to calibrate and invert the differential measurements, so as to make sky maps free from large scale systematic errors to levels less than a millionth of the CMB.
This paper describes a novel technique for measurements of the complex surface impedance Z(s) of high-T(c) superconductors over an extremely wide range of temperature, from 4.2 K and at least 200 K. The technique uses a superconducting Pb-plated Cu high-Q-cavity resonator operated at an ambient temperature of 4.2 K, with the sample (typically a 3-mm-diam x 1-mm-thick disk) mounted on a sapphire rod in the center of cavity, at a high B-field and thermally insulated from the cavity walls, making it possible to control the sample temperature externally. Since the cavity characteristics are dominated by the sample properties (the contribution of the Pb-covered walls maintained at 4.2 K is negligible), measurement of the cavity Q and resonant frequency makes it possible to measure Zs as a function of the sample temperature. The Z(s) values for bulk Y1Ba2Cu3O(y) and La(1.85)Sr(0.15)CuO4 were measured over a temperature range 4.2-100 K.
The various techniques that utilize microwave interferometry could be employed to determine distances of several thousand kilometers with an accuracy of 1 cm or 2 cm. Such measurements would be useful to obtain new knowledge of earth dynamics, greater insight into fundamental astronomical constants, and the ability to accurately navigate a spacecraft in interplanetary flight. There is, however, a basic problem, related to the presence of tropospheric water vapor, which has to be overcome before such measurements can be realized. Differing amounts of water vapor over the interferometer stations cause errors in the differential time of arrival which is the principal observable quantity. Approaches for overcoming this problem are considered, taking into account requirements for water vapor calibration to support interferometric techniques.
This paper reports the local detection of buried calibrated metal defects in metal samples by a new experimental technique, scanning microwave microscopy. This technique combines the electromagnetic measurement capabilities of a microwave vector network analyzer with the subnanometer-resolution capabilities of an atomic force microscope. The network analyzer authorizes the use of several frequencies in the range 1-6 GHz, allowing three-dimensional tomographical investigation, which is useful for the detection of bulk defects in metal materials.
Evidence is presented that microwave rotational spectroscopy can be developed for use in air pollution monitoring, with the employment of a diode-cavity spectrometer capable of detecting small concentrations of NO2, SO2, H2CO, and HN3 gas with very high specificity. The theory behind the technique is discussed, together with its application and experimental results.
A multi-point microwave interferometer (MPMI) concept was previously proposed by the authors for spatially-resolved, non-invasive tracking of a shock, reaction, or detonation front in energetic media [P. Specht et al., AIP Conf. Proc. 1793, 160010 (2017).]. The advantage of the MPMI concept over current microwave interferometry techniques is its detection of Doppler shifted microwave signals through electro-optic (EO) modulation of a laser. Since EO modulation preserves spatial variations in the Doppler shift, collecting the EO modulated laser light into a fiber array for recording with an optical heterodyne interferometer yields spatially-resolved velocity information. This work demonstrates the underlying physical principle of the MPMI diagnostic: the monitoring of a microwave signal with nanosecond temporal resolution using an optical heterodyne interferometer. For this purpose, the MPMI concept was simplified to a single-point construction using two tunable 1550 nm lasers and a 35.2 GHz microwave source. A (110) ZnTe crystal imparted the microwave frequency onto a laser, which was combined with a reference laser for determination of the microwave frequency in an optical heterodyne interferometer. A single, characteristic frequency associated with the microwave source was identified in all experiments, providing a means to monitor a microwave signal on nanosecond time scales. Lastly, areas for improving the frequency resolution of this technique are discussed, focusing on increasing the phase-modulated signal strength.