Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microwave sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Apparatus for use in determining surface conductivity at microwave frequencies

An apparatus is provided for use in determining surface conductivity of a flat or shaped conductive material at microwave frequencies. A plate has an electrically conductive surface with first and second holes passing through the plate. An electrically conductive material under test (MUT) is maintained in a spaced apart relationship with the electrically conductive surface of the plate by one or more non-conductive spacers. A first coupling loop is electrically shielded within the first hole while a second coupling loop is electrically shielded within the second hole. A dielectric resonator element is positioned between the first and second coupling loops, while also being positioned closer to the MUT than the electrically conductive surface of the plate. Microwave energy at an operating frequency f is supplied from a signal source to the first coupling loop while microwave energy received at the second coupling loop is measured. The apparatus is capable of measuring the Q-factor of the dielectric resonator situated in the cavity existing between the electrically conductive surface of the plate and the MUT. Surface conductivity of the electrically conductive surface can be determined via interpolation using: 1) the measured Q-factor with the electrically conductive surface in place, and 2) the measured Q-factor when the MUT is replaced with reference standards having known surface conductivities.

Hearn, Chase P.↗

A microwave plasma cleaning apparatus

In a microwave electron cyclotron resonance plasma source, reactive plasmas of oxygen and its mixtures of argon have been used for evaluating plasma cleaning technologies. Small aluminum samples (0.95 x 1.9 cm) were coated with thin films (less than or equal to 20 micrometers in thickness) of Shell Vitrea oil and cleaned with reactive plasmas. The discharge parameters, such as gas pressure, magnetic field, substrate biasing, and microwave power, were varied to change cleaning conditions. A mass spectroscopy (or residual gas analyzer) was used to monitor the status of plasma cleaning. Mass loss of the samples after plasma cleaning was measured to estimate cleaning rates. Measured cleaning rates of low-pressure (0.5-m torr) argon/oxygen plasmas were as high as 2.7 micrometers/min. X-ray photoelectron spectroscopy was used to determine cleanliness of the sample surfaces. In this paper, significant results of the plasma cleaning are reported and discussed.

Tsai, C. C.↗

Electron trapping in evolving coronal structures during a large gradual hard X-ray/radio burst

Gradual hard X-ray/radio bursts are characterized by their long duration, smooth time profile, time delays between peaks at different hard X-ray energies and microwaves, and radiation from extended sources in the low and middle corona. Their characteristic properties have been ascribed to the dynamic evolution of the accelerated electrons in coronal magnetic traps or to the separate acceleration of high-energy electrons in a 'second step' process. The information available so far was drawn from quality considerations of time profiles or even only from the common occurrence of emissions in different spectral ranges. This paper presents model computations of the temporal evolution of hard X-ray and microwave spectra, together with a qualitative discussion of radio lightcurves over a wide spectral range, and metric imaging observations. The basis hypothesis investigated is that the peculiar 'gradual' features can be related to the dynamical evolution of electrons injected over an extended time interval in a coronal trap, with electrons up to relativistic energies being injected simultaneously. The analyzed event (26 April. 1981) is particularly challenging to this hypothesis because of the long time delays between peaks at different X-ray energies and microwave frequencies. The observations are shown to be consistent with the hypothesis, provided that the electrons lose their energy by Coulomb collisions and possibly betatron deceleration. The access of the electrons to different coronal structures varies in the course of the event. The evolution and likely destabilization of part of the coronal plasma-magnetic field configuration is of crucial influence in determining the access to these structures and possibly the dynamical evolution of the trapped electrons through betatron deceleration in the late phase of the event.

Bruggmann, G.↗

Slot-Antenna/Permanent-Magnet Device for Generating Plasma

A device that includes a rectangular-waveguide/slot-antenna structure and permanent magnets has been devised as a means of generating a substantially uniform plasma over a relatively large area, using relatively low input power and a low gas flow rate. The device utilizes electron cyclotron resonance (ECR) excited by microwave power to efficiently generate plasma in a manner that is completely electrodeless in the sense that, in principle, there is no electrical contact between the plasma and the antenna. Plasmas generated by devices like this one are suitable for use as sources of ions and/or electrons for diverse material-processing applications (e.g., etching or deposition) and for ion thrusters. The absence of plasma/electrode contact essentially prevents plasma-induced erosion of the antenna, thereby also helping to minimize contamination of the plasma and of objects exposed to the plasma. Consequently, the operational lifetime of the rectangular-waveguide/ slot-antenna structure is long and the lifetime of the plasma source is limited by the lifetime of the associated charged-particle-extraction grid (if used) or the lifetime of the microwave power source. The device includes a series of matched radiating slot pairs that are distributed along the length of a plasma-source discharge chamber (see figure). This arrangement enables the production of plasma in a distributed fashion, thereby giving rise to a uniform plasma profile. A uniform plasma profile is necessary for uniformity in any electron- or ion-extraction electrostatic optics. The slotted configuration of the waveguide/ antenna structure makes the device scalable to larger areas and higher powers. All that is needed for scaling up is the attachment of additional matched radiating slots along the length of the discharge chamber. If it is desired to make the power per slot remain constant in scaling up, then the input microwave power must be increased accordingly. Unlike in prior ECR microwave plasma-generating devices, there is no need for an insulating window on the antenna. Such windows are sources of contamination and gradually become ineffective as they become coated with erosion products over time. These characteristics relegate prior ECR microwave plasma-generating devices to non-ion beam, non-deposition plasma applications. In contrast, the lack of need for an insulating window in the present device makes it possible to use the device in both ion-beam (including deposition) and electron-beam applications. The device is designed so that ECR takes place above each slot and the gradient of the magnetic field at each slot is enough to prevent backflow of plasma.

Foster, John E.↗

TOPEX/POSEIDON microwave radiometer performance and in-flight calibration

Results of the in-flight calibration and performance evaluation campaign for the TOPEX/POSEIDON microwave radiometer (TMR) are presented. Intercomparisons are made between TMR and various sources of ground truth, including ground-based microwave water vapor radiometers, radiosondes, global climatological models, special sensor microwave imager data over the Amazon rain forest, and models of clear, calm, subpolar ocean regions. After correction for preflight errors in the processing of thermal/vacuum data, relative channel offsets in the open ocean TMR brightness temperatures were noted at the approximately = 1 K level for the three TMR frequencies. Larger absolute offsets of 6-9 K over the rain forest indicated a approximately = 5% gain error in the three channel calibrations. This was corrected by adjusting the antenna pattern correction (APC) algorithm. AS 10% scale error in the TMR path delay estimates, relative to coincident radiosondes, was corrected in part by the APC adjustment and in part by a 5% modification to the value assumed for the 22.235 FGHz water vapor line strength in the path delay retrieval algorithm. After all in-flight corrections to the calibration, TMR global retrieval accuracy for the wet tropospheric range correction is estimated at 1.1 cm root mean square (RMS) with consistent peformance under clear, cloudy, and windy conditions.

Ruf, C. S.↗

Environmental considerations for the microwave beam from a solar power satellite

Solar power satellite (SPS) systems in geosynchronous orbit are possible future energy sources. The SPS concept uses a highly focused microwave beam to transmit the energy to the earth. The microwave power transmission system parameters are summarized, emphasizing those parameters which may affect the earth's environment. Environmental impacts of the microwave beam are discussed. The power levels for the main beam, sidelobes, grating lobes, and ground receiving antenna reradiation patterns are presented. Ionospheric/microwave beam interaction studies, experimental and theoretical, are reviewed. Possible radio frequency interference sources and the magnitude of expected interference levels are discussed.

Arndt, G. D.↗

COBE Differential Microwave Radiometers - Preliminary systematic error analysis

The techniques available for the identification and subtraction of sources of dynamic uncertainty from data of the Differential Microwave Radiometer (DMR) instrument aboard COBE are discussed. Preliminary limits on the magnitude in the DMR 1 yr maps are presented. Residual uncertainties in the best DMR sky maps, after correcting the raw data for systematic effects, are less than 6 micro-K for the pixel rms variation, less than 3 micro-K for the rms quadruple amplitude of a spherical harmonic expansion, and less than 30 micro-(K-squared) for the correlation function.

Kogut, A.↗

Igniter Testing and Development for Liquid Oxygen/Liquid Methane (LOX/LCH4) and Liquid Oxygen/Gaseous Hydrogen (LOX/GH2) Injectors

In support of NASA's efforts to advance methane technology for future exploration missions, two different igniter concepts were developed and tested at NASA's Marshall Space Flight Center for ignition of oxygen/methane propellants. The first type of igniter, an impinging injection, spark-initiated torch igniter (impinging igniter), used traditional spark plug technology to produce a small, but very intense, pulsed plasma as the ignition source. The second type of igniter, a microwave-generated plasma igniter (microwave igniter), used a microwave magnetron to produce a continuous, larger-volume plasma as the ignition source. Two new designs for both types of igniters were leveraged off past oxygen/methane igniter designs that were tested at MSFC and documented in a 2008 JANNAF paper. In this most recent work, the two new igniters were to be tested at the component level as well as inside a liquid oxygen/liquid methane (LOX/LCH4) 40-element swirl coaxial injector. Although the microwave igniter achieved ignition in every test, it encountered technical difficulties that prevented it from being tested with the injector. The impinging igniter required several design iterations as well as testing at different mixture ratios and mass flow rates before reliable operation with minimal ignition delay was achieved. The final design of the impinging igniter was successfully tested in the LOX/LCH4 injector. The same igniter was later re-configured and component-tested to demonstrate reliable ignition of oxygen/hydrogen propellants. Future tests of the impinging igniter will include ignition of a LOX/hydrogen two-stage swirl injector, which is one of several injector concepts being tested in the Lunar Lander Descent Engine Test Bed at MSFC. All igniter and injector tests have been funded by the Propulsion & Cryogenics Advanced Development project managed by Glenn Research Center and sponsored by NASA s Exploration Technology Development Program.

Osborne, Robin J.↗

On the Characterization and Mitigation of Noise in Space-borne Microwave Sounding Instruments

Space-borne microwave sounding instruments have become vital data sources for weather prediction and climate change studies. Among the various radiometer configurations, the total power microwave radiometer is particularly appealing for current and future operational satellites due to its superior sensitivity and simple design. However, its performance is vulnerable to degradation caused by receiver gain fluctuations, electronic 1/f noise, and other time varying receiver characteristics. For Numerical Weather Prediction (NWP) users, 1/f noise introduces inter-channel correlations, complicating the assimilation of affected observations and reducing their accuracy. Addressing this noise issue in ground data processing system is essential to enhance the utility of microwave sounding data. This paper focuses on the characterization and mitigation of noise in current and future microwave sounding instruments, with particular emphasis on the impact of 1/f noise. Various methods are applied to quantitatively characterize noise features in both frequency and time domains. Additionally, the influence of calibration parameters on 1/f noise are analyzed. Based on these findings, we propose a mitigation algorithm for reducing noise during the on-orbit calibration of microwave sounding instruments, aiming to improve the quality of retrieved data for operational use.

calibration↗

Spontaneous Raman scattering as a high resolution XUV radiation source

A type of high resolution XUV radiation source is described which is based upon spontaneous anti-Stokes scattering of tunable incident laser radiation from atoms excited to metastable levels. The theory of the source is summarized and two sets of experiments using He (1s2s)(1)S atoms, produced in a cw hollow cathode and in a pulsed high power microwave discharge, are discussed. The radiation source is used to examine transitions originating from the 3p(6) shell of potassium. The observed features include four previously unreported absorption lines and several sharp interferences of closely spaced autoionizing lines. A source linewidth of about 1.9 cm(-1) at 185,000 cm(-1) is demonstrated.

Rothenberg, J. E.↗

Spontaneous Raman scattering as a high-resolution XUV radiation source

A type of high resolution XUV radiation source is described which is based upon spontaneous anti-Stokes scattering of tunable incident laser radiation from atoms excited to metastable levels. The theory of the source is summarized and two sets of experiments using He (1s2s)(1)S atoms, produced in a CW hollow cathode and in a pulsed high power microwave discharge, are discussed. The radiation source is used to examine transitions originating from the 3p(6) shell of potassium. The observed features include four previously unreported absorption lines and several sharp interferences of closely spaced autoionizing lines. A source linewidth of about 1.9 cm(-1) at 185,000 cm(-1) is demonstrated. Previously announced in STAR as N83-18422

Rothenberg, J. E.↗

The effect of mismatched components on microwave noise-temperature calibrations

Analysis of errors on microwave noise-temperature measurements is important due to development of very low-noise antenna receiving systems and in the absolute accuracies to which the noise temperatures of these systems can be calibrated. Scattering parameters describe properties of the microwave network connected between noise source and receiver.

Otoshi, T. Y.↗

Summary of LSST systems analysis and integration task for SPS flight test articles

The structural and equipment requirements for two solar power satellite (SPS) test articles are defined. The first SPS concept uses a hexagonal frame structure to stabilize the array of primary tension cables configured to support a Mills Cross antenna containing 17,925 subarrays composed of dipole radiating elements and solid state power amplifier modules. The second test article consists of a microwave antenna and its power source, a 20 by 200 m array of solar cell blankets, both of which are supported by the solar blanket array support structure. The test article structure, a ladder, is comprised of two longitudinal beams (215 m long) spaced 10 m apart and interconnected by six lateral beams. The system control module structure and bridge fitting provide bending and torsional stiffness, and supplement the in plane Vierendeel structure behavior. Mission descriptions, construction, and structure interfaces are addressed.

Greenberg, H. S.↗

A frequency and timing subsystem for the ORION mobile unit

A mobile surveying instrument in support of the crustal dynamics program measures the length and direction of the distance between sites on the Earth's surface using VLBI techniques operating at microwave frequencies and extragalactic radio sources. The frequency and timing subsystem uses as a frequency standard the hydrogen maser. An important part of the subsystem is a sophisticated automatic system to monitor frequency stability and accumulated clock error.

Clements, P. A.↗

Global atmospheric moisture variability

Research efforts during FY-88 have focused on completion of several projects relating to analysis of FGGE data during SOP-1 and on expanded studies of global atmospheric moisture. In particular, a revised paper on the relationship between diabatic heating and baroclinicity in the South Pacific Convergence Zone (SPCZ) was submitted. A summary of completed studies on diagnostic convective parameterization was presented at the Satellite Meteorology and Oceanography Convergence last February. These investigations of diabatic heating in the SPCZ have demonstrated the requirement for a more quantitative description of atmospheric moisture. As a result, efforts were directed toward use of passive remote microwave measurements from the Nimbus-7 SMMR and the DOD's Special Sensor Microwave Imager (SSMI/I) as critical sources of moisture data. Activities this year are summarized.

Robertson, Franklin R.↗

Microwaves and hard X-rays from solar flares - Multithermal and nonthermal interpretations

It is generally accepted that the hard X rays and centimeter-wavelength (microwave) radio emission from impulsive solar flares come from a common source. The present investigation is concerned with the development of a model for impulsive hard X rays and microwaves under the assumption that they arise from the same distribution of electrons, possibly, but not necessarily, from the same volume of space. An examination is conducted of a model in which the hard X rays and microwaves are produced in a homogeneous volume by a power-law electron distribution (nonthermal model). An investigation is also performed of a multithermal model in which the hard X rays and microwaves come from an inhomogeneous source, a nest of magnetic arches in which the highest temperature electrons are confined to a small core, and where, away from the core, the temperature decreases. It is found that more or less satisfactory models can be constructed using either multithermal or nonthermal, power-law electron distributions.

Dulk, G. A.↗

Energetic electrons in impulsive and extended solar flares as deduced from flux correlations between hard X-rays and microwaves

The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped in a coronal loop or loops.

Kosugi, Takeo↗

Active region magnetic fields inferred from simultaneous VLA microwave maps, X-ray spectroheliograms, and magnetograms

The VLA maps at 6-cm wavelength discussed here are generated from observations of a solar active region (NOAA 2363) on March 29 and 30, 1980. The X-ray spectroheliograms were acquired for this region in the lines of O VIII, Ne IX, Mg XI, Si XIII, S XV, and Fe XXV. It is found that the peaks of X-ray and 6-cm emission do not coincide but that the sources in the two wavelength domains tend to overlap. These facts are seen as evidence for the existence of opacity mechanisms other than thermal bremsstrahlung. To quantify this assertion, differential emission measures are computed to derive densities and temperatures. Using these and calculated force-free magnetic fields from Kitt Peak magnetograms, an assessment is made of the mechanism of gyroresonance absorption at low harmonics of the electron gyrofrequency as the source of opacity responsible for the microwave features. It is concluded that large-scale currents must be present in the active region loops to account for the bright 6-cm sources far from sunspots.

Schmahl, E. J.↗