Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microscale”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Microscale Distribution of Hydrogen Isotopes in Two Carbonaceous Chondrites

Hydrogen isotopes are highly variable among primitive meteorites and interplanetary dust particles (IDPs) [1, 2]. In particular, many primitive objects exhibit D (and N-15) enrichments, relative to terrestrial values, thought to represent partial preservation of presolar material fractionated in molecular clouds. However, the diversity of D/H ratios among IDPs and chondrites indicates a complex history of processing in the solar nebula and on meteorite parent bodies. Deconvolving this record requires identification and characterization of the carriers of D enrichments in different objects. Isotopic imaging has proven to be a powerful method to quantitatively explore the distribution of D/H ratios on a one to several m scale in IDPs [2-4] and the CR chondrite Renazzo [5, 6]. In this study, we have used ion imaging to explore the microscale D/H distribution of two carbonaceous chondrites, Tagish Lake (unique) and Al Rais (CR2). Previous D/H measurements (on a ~tens of microns scale) of Tagish Lake matrix fragments by Messenger [7] and Engrand et al. [8] have found different results, most likely related to the analytical techniques used. Previous work has also shown a large range of D/H ratios in CR chondrites, including very large variations on a scale of a few microns [5, 6, 9].

Young, A. F.↗

Microscale Particulate Classifiers (MiPAC) Being Developed

The NASA Glenn Research Center is developing microscale sensors to characterize atmospheric-borne particulates. The devices are fabricated using MEMS (microelectromechanical systems) technologies. These technologies are derived from those originally developed in support of the semiconductor processing industry. The resulting microsensors can characterize a wide range of particles and are, therefore, suitable to a broad range of applications. This project is supported under a collaborative program called the Glennan Microsystems Initiative. The initiative comprises members of NASA Glenn Research Center, various university affiliates from the State of Ohio, and a number of participating industrial partners. Funding is jointly provided by NASA, the State of Ohio, and industrial members. The work described here is a collaborative arrangement between researchers at Glenn, the University of Minnesota, The National Institute of Standards and Technology (NIST), and the Cleveland State University. Actual device fabrication is conducted at Glenn and at the laboratories of Case Western Reserve University. Case Western is also located in Cleveland, Ohio, and is a participating member of the initiative. The principal investigator for this project is Paul S. Greenberg of Glenn. Two basic types of devices are being developed, and target different ranges of particle sizes. The first class of devices, which is used to measure nanoparticles (i.e., particles in the range of 0.002 to 1 mm), is based on the technique of Electrical Mobility Classification. This technique also affords the valuable ability of measuring the electrical charge state of the particles. Such information is important in the understanding of agglomeration mechanisms and is useful in the development of methods for particle repulsion. The second type of device being developed, which utilizes optical scattering, is suitable for particles larger than 1 mm. This technique also provides information on particle shape and composition. Applications for these sensors include fundamental planetary climatology, monitoring and filtration in spacecraft, human habitation modules and related systems, characterization of particulate emissions from propulsion and power systems, and as early warning sensors for both space-based and ter-restrial fire detection. These devices are also suitable for characterizing biological compounds such as allergens, infectious agents, and biotoxic agents.

Greenberg, Paul S.↗

Microscale out-of-plane anemometer

A microscale out-of-plane thermal sensor. A resistive heater is suspended over a substrate by supports raised with respect to the substrate to provide a clearance underneath the resistive heater for fluid flow. A preferred fabrication process for the thermal sensor uses surface micromachining and a three-dimensional assembly to raise the supports and lift the resistive heater over the substrate.

Liu, Chang↗

Using PEACE Data from the four CLUSTER Spacecraft to Measure Compressibility, Vorticity, and the Taylor Microscale in the Magnetosheath and Plasma Sheet

We present determinations of compressibility and vorticity in the magnetosheath and plasma sheet using moments from the four PEACE thermal electron instruments on CLUSTER. The methodology used assumes a linear variation of the moments throughout the volume defined by the four satellites, which allows spatially independent estimates of the divergence, curl, and gradient. Once the vorticity has been computed, it is possible to estimate directly the Taylor microscale. We have shown previously that the technique works well in the solar wind. Because the background flow speed in the magnetosheath and plasma sheet is usually less than the Alfven speed, the Taylor frozen-in-flow approximation cannot be used. Consequently, this four spacecraft approach is the only viable method for obtaining the wave number properties of the ambient fluctuations. Our results using electron velocity moments will be compared with previous work using magnetometer data from the FGM experiment on Cluster.

Goldstein, Melvyn L.↗

Method for fabricating a microscale anemometer

Method for fabricating a microscale anemometer on a substrate. A sacrificial layer is formed on the substrate, and a metal thin film is patterned to form a sensing element. At least one support for the sensing element is patterned. The sacrificial layer is removed, and the sensing element is lifted away from the substrate by raising the supports, thus creating a clearance between the sensing element and the substrate to allow fluid flow between the sensing element and the substrate. The supports are raised preferably by use of a magnetic field applied to magnetic material patterned on the supports.

Liu, Chang↗

Evaluation of the Anisotropic Radiative Conductivity of a Low-Density Carbon Fiber Material from Realistic Microscale Imaging

The radiative heat transfer inside a low-density carbon fiber insulator is analyzed using a three-dimensional direct simulation model. A robust procedure is presented for the numerical calculation of the geometric configuration factor to compute the radiative energy exchange processes among the small discretized surface areas of the fibrous material. The methodology is applied to a polygonal mesh of a fibrous insulator obtained from three-dimensional microscale imaging of the real material. The anisotropic values of the radiative conductivity are calculated for that geometry. The results yield both directional and thermal dependence of the radiative conductivity.

Evaluation↗

Microscale Analysis of Spacecraft Heat Shields

Imagine entering Earth’s atmosphere after returning from the outer solar system. A heat shield less than 2 inches thick protects you from temperatures up to 2,900° Celsius (5,252° Fahrenheit). Such conditions were experienced by NASA’s Stardust capsule during reentry in 2006. The only materials capable of providing the necessary protection are composites with complex microstructures. Evaluating these materials is difficult, requiring precise knowledge of their properties. To this end, NASA scientists are developing research codes to compute material properties and simulate ablation at the microscale using agency supercomputers. Utilizing these tools, along with experiments, researchers are working to push the limits of spaceflight, allowing for greater flexibility in future space missions.

Thornton, John M.↗

Microscale Characterization of Damage Accumulation in CMCs

The developing roles of damage mechanisms in the failure response of SiC/SiC minicomposites was investigated by the characterization of microscale damage accumulation with respect to microstructure. A multi-modal approach combining spatially resolved acoustic emission (AE) with tensile testing in-SEM (scanning electron microscope) was used to simultaneously examine surface (observed in-SEM) and bulk damage (monitored via AE). Strong agreement was shown between the evolving crack density estimated by AE and in-SEM measurements. The following were observed: (i) in-plane matrix content and distribution impacted crack growth; (ii) spatially-distributed matrix cracks generated varying stress-dependent AE; and (iii) certain individual cracks became more probable failure locations due to unique combinations of damage mechanisms that drove their growth. This approach enabled characterizing potential failure determinants and suggests that early damage behavior is related to certain microstructural features (e.g. surface flaws), while subsequent damage behavior is coupled to interactions of local mechanisms evolving with stress.

ceramic matrix composites↗

Bridging the Gap Between Microscale Modeling and Additive Manufacturing for TPS

An overview of the now open-source NASA ARC software PuMA will be provided. On top of the well-documented ability to import and compute material properties from micro-CT images, PuMA has the ability to design microstructures and compute/predict material properties such as: porosity, permeability, tortuosity, thermal and electrical conductivity, tensile strength, etc. Therefore, a whole new range of capabilities is available, and provides users with the ability to build TPS materials (both fibrous and woven types) and optimize their properties based on missions and requirements. This talk will aim to provide a seed to start bridging the gap between microscale modeling of TPS materials and additive manufacturing.

Conductivity↗

Observing Coronal Microscales and Their Connection With Mesoscales

Why the Sun has a tenuous upper atmosphere some 1000 times hotter than the photosphere is a fundamental open problem in space plasma physics despite decades of study. A leading hypothesis, supported by indirect evidence, is that in most of the corona heating is confined to narrow current sheets in which energy is dissipated despite the low large-scale resistivity of the coronal plasma. Although the kinetic scales of reconnection or wave heating are beyond remote observation, thermal structure on scales ≲100 km are expected to be produced by the primary heating mechanisms operating within a filamentary magnetic field. This white paper considers what could be learned from direct observations of coronal plasma on those scales and outlines a mission concept that is more fully described in a Heliophysics Mission Concept Study for the Coronal Microscale Observatory.

Douglas Rabin↗

Microscale isoelectric fractionation using immobilized pH-specific membranes for multi-dimensional analysis.

We report on advancements of our microscale isoelectric fractionation ({mu}IEFr) methodology for fast on-chip separation and concentration of proteins based on their isoelectric points (pI). We establish that proteins can be fractionated depending on posttranslational modifications into different pH specific bins, from where they can be efficiently transferred to downstream membranes for additional processing and analysis. This technology can enable on-chip multidimensional glycoproteomics analysis, as a new approach to expedite biomarker identification and verification.

59 BASIC BIOLOGICAL SCIENCES↗

Microscale autonomous sensor and communications module

Various technologies pertaining to a microscale autonomous sensor and communications module are described herein. Such a module includes a sensor that generates a sensor signal that is indicative of an environmental parameter. An integrated circuit receives the sensor signal and generates an output signal based at least in part upon the sensor signal. An optical emitter receives the output signal and generates an optical signal as a function of the output signal. An energy storage device is configured to provide power to at least the integrated circuit and the optical emitter, and wherein the module has a relatively small diameter and thickness.

97 MATHEMATICS AND COMPUTING↗

Devices, systems, and methods for microscale isoelectric fractionation

Embodiments of the present invention provide devices, systems, and methods for microscale isoelectric fractionation. Analytes in a sample may be isolated according to their isoelectric point within a fractionation microchannel. A microfluidic device according to an embodiment of the invention includes a substrate at least partially defining a fractionation microchannel. The fractionation microchannel has at least one cross-sectional dimension equal to or less than 1 mm. A plurality of membranes of different pHs are disposed in the microchannel. Analytes having an isoelectric point between the pH of the membranes may be collected in a region of the fractionation channel between the first and second membranes through isoelectric fractionation.

59 BASIC BIOLOGICAL SCIENCES↗

Devices, systems, and methods for microscale isoelectric fractionation

Embodiments of the present invention provide devices, systems, and methods for microscale isoelectric fractionation. Analytes in a sample may be isolated according to their isoelectric point within a fractionation microchannel. A microfluidic device according to an embodiment of the invention includes a substrate at least partially defining a fractionation microchannel. The fractionation microchannel has at least one cross-sectional dimension equal to or less than 1 mm. A plurality of membranes of different pHs are disposed in the microchannel. Analytes having an isoelectric point between the pH of the membranes may be collected in a region of the fractionation channel between the first and second membranes through isoelectric fractionation.

47 OTHER INSTRUMENTATION↗

Microscale gas breakdown device and process

A microscale gas breakdown device includes a first surface and a second surface. The first surface and the second surface define a gap distance. The device includes a perturbation on the first surface or the second surface. The perturbation is defined by a height value and a radius value. The device includes a current source or a voltage source configured to apply a current or a voltage across the first surface and the second surface. In response to the current or the voltage being applied, a resulting discharge travels along a first discharge path in response to being exposed to a high pressure and a second discharge path in response to being exposed to a low pressure.

Fu, Yangyang↗

Microscale depletion of high abundance proteins in human biofluids using IgY14 immunoaffinity resin: Analysis of human plasma and cerebrospinal fluid

Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 µL) due to low yields stemming from losses caused by nonspecific binding to the column matrix. Additionally, the cost of the depletion media can be prohibitive for larger scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large scale studies. We characterized the performance of a 346 µL column volume micro-scale depletion system, using four different flow rates to determine the most effective depletion conditions for ~6 μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10 mL depletion column served as the control. Results showed depletion efficiency of the micro-scale column increased as flow rate decreased, and that our micro-depletion was reproducible. We found, in an initial application, a 600 µL sample of human cerebral spinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.

59 BASIC BIOLOGICAL SCIENCES↗