Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “micro”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Buckling analysis of planar compression micro-springs

Large compression deformation causes micro-springs buckling and loss of load capacity. We analyzed the impact of structural parameters and boundary conditions for planar micro-springs, and obtained the change rules for the two factors that affect buckling. A formula for critical buckling deformation of micro-springs under compressive load was derived based on elastic thin plate theory. Results from this formula were compared with finite element analysis results but these did not always correlate. Therefore, finite element analysis is necessary for micro-spring buckling analysis. We studied the variation of micro-spring critical buckling deformation caused by four structural parameters using ANSYS software under two constraint conditions. The simulation results show that when an x-direction constraint is added, the critical buckling deformation increases by 32.3-297.9%. The critical buckling deformation decreases with increase in micro-spring arc radius or section width and increases with increase in micro-spring thickness or straight beam width. We conducted experiments to confirm the simulation results, and the experimental and simulation trends were found to agree. Buckling analysis of the micro-spring establishes a theoretical foundation for optimizing micro-spring structural parameters and constraint conditions to maximize the critical buckling load.

36 MATERIALS SCIENCE↗

Non-linear macro evolution of a dc driven micro atmospheric glow discharge

We studied the macro evolution of the micro atmospheric glow discharge generated between a micro argon jet into ambient air and static water. The micro discharge behaves similarly to a complex ecosystem. Non-linear behaviors are found for the micro discharge when the water acts as a cathode, different from the discharge when water behaves as an anode. Groups of snapshots of the micro discharge formed at different discharge currents are captured by an intensified charge-coupled device with controlled exposure time, and each group consisted of 256 images taken in succession. Edge detection methods are used to identify the water surface and then the total brightness is defined by adding up the signal counts over the area of the micro discharge. Motions of the water surface at different discharge currents show that the water surface lowers increasingly rapidly when the water acts as a cathode. In contrast, the water surface lowers at a constant speed when the water behaves as an anode. The light curves are similar to logistic growth curves, suggesting that a self-inhibition process occurs in the micro discharge. Meanwhile, the total brightness increases linearly during the same time when the water acts as an anode. Discharge-water interactions cause the micro discharge to evolve. The charged particle bomb process is probably responsible for the different behaviors of the micro discharges when the water acts as cathode and anode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of the optically stimulated luminescence (OSL) technique for mouse dosimetry in micro-CT imaging

Purpose: Micro-CT is considered to be a powerful tool to investigate various models of disease on anesthetized animals. In longitudinal studies, the radiation dose delivered by the micro-CT to the same animal is a major concern as it could potentially induce spurious effects in experimental results. Optically stimulated luminescence dosimeters (OSLDs) are a relatively new kind of detector used in radiation dosimetry for medical applications. The aim of this work was to assess the dose delivered by the CT component of a micro-SPECT (single-photon emission computed tomography)/CT camera during a typical whole-body mouse study, using commercially available OSLDs based on Al{sub 2}O{sub 3}:C crystals.Methods: CTDI (computed tomography dose index) was measured in micro-CT with a properly calibrated pencil ionization chamber using a rat-like phantom (60 mm in diameter) and a mouse-like phantom (30 mm in diameter). OSLDs were checked for reproducibility and linearity in the range of doses delivered by the micro-CT. Dose measurements obtained with OSLDs were compared to those of the ionization chamber to correct for the radiation quality dependence of OSLDs in the low-kV range. Doses to tissue were then investigated in phantoms and cadavers. A 30 mm diameter phantom, specifically designed to insert OSLDs, was used to assess radiation dose over a typical whole-body mouse imaging study. Eighteen healthy female BALB/c mice weighing 27.1 ± 0.8 g (1 SD) were euthanized for small animal measurements. OLSDs were placed externally or implanted internally in nine different locations by an experienced animal technician. Five commonly used micro-CT protocols were investigated.Results: CTDI measurements were between 78.0 ± 2.1 and 110.7 ± 3.0 mGy for the rat-like phantom and between 169.3 ± 4.6 and 203.6 ± 5.5 mGy for the mouse-like phantom. On average, the displayed CTDI at the operator console was underestimated by 1.19 for the rat-like phantom and 2.36 for the mouse-like phantom. OSLDs exhibited a reproducibility of 2.4% and good linearity was found between 60 and 450 mGy. The energy scaling factor was calculated to be between 1.80 ± 0.16 and 1.86 ± 0.16, depending on protocol used. In phantoms, mean doses to tissue over a whole-body CT examination were ranging from 186.4 ± 7.6 to 234.9 ± 7.1 mGy. In mice, mean doses to tissue in the mouse trunk (thorax, abdomen, pelvis, and flanks) were between 213.0 ± 17.0 and 251.2 ± 13.4 mGy. Skin doses (3 OSLDs) were much higher with average doses between 350.6 ± 25.3 and 432.5 ± 34.1 mGy. The dose delivered during a topogram was found to be below 10 mGy. Use of the multimouse bed of the system gave a significantly 20%–40% lower dose per animal (p < 0.05).Conclusions: Absorbed doses in micro-CT were found to be relatively high. In micro-SPECT/CT imaging, the micro-CT unit is mainly used to produce a localization frame. As a result, users should pay attention to adjustable CT parameters so as to minimize the radiation dose and avoid any adverse radiation effects which may interfere with biological parameters studied.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mississippi State University Cooling, Heating, and Power (Micro-CHP) and Bio-Fuel Center

Between 2008 and 2014, the U.S. Department of Energy funded the MSU Micro-CHP and Bio-Fuel Center located at Mississippi State University. The overall objective of this project was to enable micro-CHP (micro-combined heat and power) utilization, to facilitate and promote the use of CHP systems and to educate architects, engineers, and agricultural producers and scientists on the benefits of CHP systems. Therefore, the work of the Center focused on the three areas: CHP system modeling and optimization, outreach, and research. In general, the results obtained from this project demonstrated that CHP systems are attractive because they can provide energy, environmental, and economic benefits. Some of these benefits include the potential to reduce operational cost, carbon dioxide emissions, primary energy consumption, and power reliability during electric grid disruptions. The knowledge disseminated in numerous journal and conference papers from the outcomes of this project is beneficial to engineers, architects, agricultural producers, scientists and the public in general who are interested in CHP technology and applications. In addition, more than 48 graduate students and 23 undergraduate students, benefited from the training and research performed in the MSU Micro-CHP and Bio-Fuel Center. The project scope consisted of six separate, but related areas: 1. Micro-CHP modeling - Computational simulations and verification/validation studies of selected models for technical and economic viability. 2. Fuel flexibility in micro-CHP applications – Demonstrating and quantifying the operation of micro-CHP systems on alternative fuels. 3. Outreach activities – Providing provide educational materials for engineers and architects and conducting outreach seminars, workshops, and demonstrations for engineers and architects as well as for more general audiences. 4. Biofuel and opportunity fuel processing and utilization – Determining the processing requirements and feasibility to utilize biofuels and disaster debris for micro-CHP systems. 5. CHP Systems Optimization – Optimization of internal combustion and Stirling engines integrated with heat recovery systems for CHP operation. 6. Distributed Generation and Grid Interconnection – Developing requirements and control systems for interconnection of micro-CHP systems with the electrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Micro rotary machine and methods for using same

A micro rotary machine may include a micro actuator and a micro shaft coupled to the micro actuator. The micro shaft comprises a horizontal shaft and is operable to be rotated by the micro actuator. A micro tool is coupled to the micro shaft and is operable to perform work in response to motion of the micro shaft.

47 OTHER INSTRUMENTATION↗

Method of fabricating a micro machine

A micro machine may be in or less than the micrometer domain. The micro machine may include a micro actuator and a micro shaft coupled to the micro actuator. The micro shaft is operable to be driven by the micro actuator. A tool is coupled to the micro shaft and is operable to perform work in response to at least motion of the micro shaft.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Micro rotary machine and methods for using same

A micro rotary machine may include a micro actuator and a micro shaft coupled to the micro actuator. The micro shaft comprises a horizontal shaft and is operable to be rotated by the micro actuator. A micro tool is coupled to the micro shaft and is operable to perform work in response to motion of the micro shaft.

42 ENGINEERING↗

Methods and systems for micro machines

A micro machine may be in or less than the micrometer domain. The micro machine may include a micro actuator and a micro shaft coupled to the micro actuator. The micro shaft is operable to be driven by the micro actuator. A tool is coupled to the micro shaft and is operable to perform work in response to at least motion of the micro shaft.

42 ENGINEERING↗

Methods and systems for micro machines

A micro machine may be in or less than the micrometer domain. The micro machine may include a micro actuator and a micro shaft coupled to the micro actuator. The micro shaft is operable to be driven by the micro actuator. A tool is coupled to the micro shaft and is operable to perform work in response to at least motion of the micro shaft.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Methods and systems for micro machines

A micro machine may be in or less than the micrometer domain. The micro machine may include a micro actuator and a micro shaft coupled to the micro actuator. The micro shaft is operable to be driven by the micro actuator. A tool is coupled to the micro shaft and is operable to perform work in response to at least motion of the micro shaft.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Methods and systems for micro machines

A micro machine may be in or less than the micrometer domain. The micro machine may include a micro actuator and a micro shaft coupled to the micro actuator. The micro shaft is operable to be driven by the micro actuator. A tool is coupled to the micro shaft and is operable to perform work in response to at least motion of the micro shaft.

42 ENGINEERING↗

Effect of helical micro-fins on two-phase flow behavior of R410A evaporating in horizontal round tubes obtained through visualization

This paper presents a new approach in visualization of the evaporation mechanism and the two phase flow. The visualization test section is a transparent micro-fin tube made by 3D printing. The 3D printing technology helps reproduce the real geometry in commercial metal micro-fin tubes. Even though the wall material is different from the real metal, this new method provides a more complete understanding of the mechanisms of flow boiling and the heat transfer enhancement due to micro-fin geometry. To investigate the effect of micro-fin geometries on two-phase flow behavior, R410A flow boiling experiments are conducted at 1°C saturation temperature and visualized through a clear smooth tube and micro-fin tubes of 0°, 10° and 18° helix angles. The results showed that the annular flow pattern in the helical micro-fin tube occurred at a lower vapor quality than the smooth and axial micro-fin tubes. Helix angle affects the transition boundary of stratified wavy flow to wavy annular flow, which shifts downward (to lower mass flux and vapor quality conditions) as the helix angle increases. Other transitions are not significantly affected by the helix angle. Helical micro-fin tubes with different groove directions were made to understand the flow behavior on the upward side and downward side of the tube.

3D printing↗

A methodology for understanding the impacts of large-scale penetration of micro-combined heat and power

Co-generation at small kW-e scale has been stimulated in recent years by governments and energy regulators as one way to increasing energy efficiency and reducing CO 2 emissions. If a widespread adoption should be realized, their effects from a system's point of view are crucial to understand the contributions of this technology. Based on a methodology that uses long-term capacity planning expansion, this paper explores some of the implications for an electric power system of having a large number of micro-CHPs. Results show that fuel cells-based micro-CHPs have the best and most consistent performance for different residential demands from the customer and system's perspectives. As the penetration increases at important levels, gas-based technologies - particularly combined cycle units - are displaced in capacity and production, which impacts the operation of the electric system during summer peak hours. Other results suggest that the tariff design impacts the economic efficiency of the system and the operation of micro-CHPs under a price-based strategy. Finally, policies aimed at micro-CHPs should consider the suitability of the technology (in size and heat-to-power ratio) to meet individual demands, the operational complexities of a large penetration, and the adequacy of the economic signals to incentivize an efficient and sustainable operation. Highlights: Capacity displacements and daily operation of an electric power system are explored; Benefits depend on energy mix, prices, and micro-CHP technology and control scheme; Benefits are observed mostly in winter when micro-CHP heat and power are fully used; Micro-CHPs mostly displace installed capacity from natural gas combined cycle units; and, Tariff design impacts economic efficiency of the system and operation of micro-CHPs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A tutorial on the micro-trench technique for incident ion angle, material erosion, and impurity deposition measurements at plasma-facing surfaces

The micro-trench method is a new technique to measure polar and azimuthal incident ion angles, material erosion, and impurity deposition at plasma-facing surfaces, and has been applied in the DIII-D divertor. This article gives a tutorial of the micro-trench technique consisting of six steps: (1) micro-trench fabrication, (2) pre-exposure measurement of the fabricated micro-trench geometry, (3) tracer material deposition, (4) plasma exposure, (5) post-exposure observation of the tracer material, and (6) post-exposure measurement of the micro-trench geometry. Two criteria need to be satisfied to apply the micro-trench method successfully: (i) uniform impurity deposition on the micro-trench floor, and (ii) erosion dominated by the physical sputtering induced by the impinging ions. Furthermore, when those two criteria are satisfied, post-exposure analysis of the impurity deposition patterns on the micro-trench floor may be used to determine the polar and azimuthal incident ion directions (mean values of the ion angle directions), erosion rate, and impurity deposition rate during plasma exposure without computational interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication Of Micro-Nozzles Via {mu}-EDM Process

Since traditional handling mechanisms have an unpredictable behavior at micro scale, micro-assembly is a bottleneck in the development of hybrid micro-systems, and the development of new approaches is strongly demanded. In this paper, a recent study of the fabrication of a ceramics vacuum micro-gripper to handle parts in the range of hundreds of microns (300-1000) is presented. Among the possible micro manufacturing processes, micro-EDM has been selected as proving to be a very competitive fabrication technology for the manufacturing of ultra miniature components and micro sized features. The influence of the process parameters on the machining performance of interest is firstly investigated; then, the experimental results on machining the micro gripper are presented, finally concluding remarks are given.

36 MATERIALS SCIENCE↗

Dosimetry concepts for scanner quality assurance and tissue dose assessment in micro-CT

Purpose: At present, no established methods exist for dosimetry in micro computed tomography (micro-CT). The purpose of this study was therefore to investigate practical concepts for both dosimetric scanner quality assurance and tissue dose assessment for micro-CT. Methods: The computed tomography dose index (CTDI) was adapted to micro-CT and measurements of the CTDI both free in air and in the center of cylindrical polymethyl methacrylate (PMMA) phantoms of 20 and 32 mm diameter were performed in a 6 month interval with a 100 mm pencil ionization chamber calibrated for low tube voltages. For tissue dose assessment, z-profile measurements using thermoluminescence dosimeters (TLDs) were performed and both profile and CTDI measurements were compared to Monte Carlo (MC) dose calculations to validate an existing MC tool for use in micro-CT. The consistency of MC calculations and TLD measurements was further investigated in two mice cadavers. Results: CTDI was found to be a reproducible quantity for constancy tests on the micro-CT system under study, showing a linear dependence on tube voltage and being by definition proportional to mAs setting and z-collimation. The CTDI measured free in air showed larger systematic deviations after the 6 month interval compared to the CTDI measured in PMMA phantoms. MC calculations were found to match CTDI measurements within 3% when using x-ray spectra measured at our micro-CT installation and better than 10% when using x-ray spectra calculated from semi-empirical models. Visual inspection revealed good agreement for all z-profiles. The consistency of MC calculations and TLD measurements in mice was found to be better than 10% with a mean deviation of 4.5%. Conclusions: Our results show the CTDI implemented for micro-CT to be a promising candidate for dosimetric quality assurance measurements as it linearly reflects changes in tube voltage, mAs setting, and collimation used during the scan, encouraging further studies on a variety of systems. For tissue dose assessment, MC calculations offer an accurate and fast alternative to TLD measurements allowing for dose calculations specific to any geometry and scan protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-84: Accuracy Comparison of Multi-Modality Image-Based Volumes of Rodent Solid Tumors Using In-Air Micro-CT Image Volume

Purpose: Tumor volume is considered as a better predictor for therapy response monitoring and tumor staging over Response Evaluation Criteria In Solid Tumors (RECIST) or World Health Organization (WHO) criteria. In this study, the accuracy of subcutaneous rodent tumor volumes using preclinical magnetic resonance imaging (MRI), micro-computed tomography (micro-CT) and ultrasound (US) equipment and with an external caliper was compared using in-air micro-CT image volume of excised tumors determined as reference tumor volume in our prior study. Methods: MR, US and micro-CT images of subcutaneous SCC4 head and neck tumor xenografts were acquired 4, 6, 9, 11 and 13 days after tumor cell inoculation. Before MR and US scans, caliper measurements were made. After tumors were excised, in-air micro-CT imaging and ex vivo caliper measurements were performed. Tumor volumes were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three image modalities and caliper, and compared with reference tumor volume by linear regression analysis as well as Bland-Altman plots. A one-way Analysis of Variance (ANOVA) test was also performed to compare volumes among caliper measurements. Results: The correlation coefficients (R2) of the regression lines for tumor volumes measured by the three imaging modalities and caliper were 0.9939, 0.9669, 0.9806, 0.9274, 0.9619 and 0.9819 for MRI, US and micro-CT, caliperbeforeMRI, caliperbeforeUS and ex vivo caliper respectively. In Bland-Altman plots, the average of tumor volume difference from reference tumor volume (bias) was significant for caliper and micro- CT, but not for MRI and US. Comparison of caliper measurements showed a significant difference (p < 0.05). Conclusion: Using the in-air micro-CT image volume, tumor volume measured by MRI was the most accurate among the three imaging modalities. In vivo caliper volume measurements showed unreliability while ex vivo caliper measurements reduced errors.

60 APPLIED LIFE SCIENCES↗

Advanced Moderation Module for High-Temperature Micro-Reactor Applications

Development and deployment of micro-reactors that provide competitive efficiency, prevailing compactness, and inherent safety is an immediate focus of the U.S. nuclear industry. For thermal neutron micro-reactors operating at elevated temperature for optimized efficiency, such as micro molten-salt reactors (MSRs), heat-pipe reactors, and very-high temperature reactors (VHTRs), high-performance moderator based on metal hydride can enhance the neutron economy and therefore achieve reduced weight and enhanced portability. As unclad metal hydride inevitably decomposes at elevated temperature, an enclosure is required for hydride moderator to deliver desired performance at elevated temperatures. Conventional moderator enclosure solutions based on high-temperature alloys introduce extraneous neutron penalty into the micro-reactor, affecting the neutronic benefits provided by the hydride moderator. Additionally, the compatibility between the high-temperature alloy enclosure and the micro-reactor matrix is also a potential issue. In this report, we disclose an Advanced Moderator Module (AMM) concept enabled by an innovative enclosure solution combining the advantages of refractory metals, ceramic matrix composites (CMCs), and advanced coating technology to serve as hydrogen permeation barrier up to very-high temperatures. A schematic description of the AMM structure is illustrated in Figure A1. The AMM contains a moderating material core made of metal hydride with high thermal stability, such as YH 2-x . The hydride core is enclosed by an H 2 barrier layer coated on a ductile refractory metal liner to minimize hydrogen loss during high-temperature operation. A ceramic matrix composite (CMC) cladding is adopted to provide further structural strength, especially during power transients. Between the CMC cladding and metal liner, an extra diffusion barrier coating is inserted to suppress the chemical interaction at elevated temperatures. Hence, based on a series of innovative material solutions, the AMM is capable of containing the metal hydride core at elevated temperature (>900oC) inside coated and lined CMC envelop with negligible hydrogen loss throughout the microreactor lifetime. The benefit of the AMM technology was assessed based on a comprehensive multi-stage reactor-physics analysis. Advanced moderation based on hydride metals (such as YH2-x) enables reaching optimum moderation with higher fuel content than traditional VHTR technology, which is required to design compact micro-reactor cores targeting long-life operation. The AMM enclosure technology provides lower thermal neutron absorption rates than traditional solutions (based on stainless steel or Mo-based alloy such as TZM), which reduces the fissile enrichment requirements by 6-8% on a TRISO-fueled design based on the EMPIRE core. Finally, combining the hydride moderator with neutron transparent enclosure solutions provides significant potential to boost neutronics performance of micro-reactors in terms of increased core lifetime or reduced size and weight by 30-50% on a micro-reactor based on the Holos Quad technology. The progress and plans for on-going development and demonstration efforts are also discussed in this report. The current demonstration of AMM is focused on the hydrogen diffusion barrier demonstration under thermal cycling, while radiation tolerance demonstration is planned. The next step of the demonstration plan will be the assembly of miniature AMM for high-temperature testing, which can be used as a prototype for future pilot scale demonstration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗