Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

WE-A-BRE-01: Debate: To Measure or Not to Measure

Recent studies have highlighted some of the limitations of patient-specific pre-treatment IMRT QA measurements with respect to assessing plan deliverability. Pre-treatment QA measurements are frequently performed with detectors in phantoms that do not involve any patient heterogeneities or with an EPID without a phantom. Other techniques have been developed where measurement results are used to recalculate the patient-specific dose volume histograms. Measurements continue to play a fundamental role in understanding the initial and continued performance of treatment planning and delivery systems. Less attention has been focused on the role of computational techniques in a QA program such as calculation with independent dose calculation algorithms or recalculation of the delivery with machine log files or EPID measurements. This session will explore the role of pre-treatment measurements compared to other methods such as computational and transit dosimetry techniques. Efficiency and practicality of the two approaches will also be presented and debated. The speakers will present a history of IMRT quality assurance and debate each other regarding which types of techniques are needed today and for future quality assurance. Examples will be shared of situations where overall quality needed to be assessed with calculation techniques in addition to measurements. Elements where measurements continue to be crucial such as for a thorough end-to-end test involving measurement will be discussed. Operational details that can reduce the gamma tool effectiveness and accuracy for patient-specific pre-treatment IMRT/VMAT QA will be described. Finally, a vision for the future of IMRT and VMAT plan QA will be discussed from a safety perspective. Learning Objectives: Understand the advantages and limitations of measurement and calculation approaches for pre-treatment measurements for IMRT and VMAT planning Learn about the elements of a balanced quality assurance program involving modulated techniques Learn how to use tools and techniques such as an end-to-end test to enhance your IMRT and VMAT QA program.

60 APPLIED LIFE SCIENCES↗

Measurement of Sauter mean diameter in diesel sprays using a scattering–absorption measurement ratio technique

A new diagnostic for the quantification of Sauter mean diameter in high-pressure fuel sprays has been recently developed using combined optical and X-ray measurements at the Georgia Institute of Technology and Argonne National Laboratory, respectively. This diagnostic utilizes liquid scattering extinction measurements from diffuse back-illumination imaging, conducted at Georgia Tech, and liquid absorption measurements from X-ray radiography, conducted at Argonne’s Advanced Photon Source. The new diagnostic, entitled the scattering–absorption measurement ratio, quantifies two-dimensional distributions of path-integrated Sauter mean diameter, enabling the construction of the spatial history of drop size development within practical fuel sprays. This technique offers unique benefits over conventional drop-sizing methods in that it can be more robust in optically dense regions of the spray, while also providing high spatial resolution of the corresponding droplet field. The methodology for quantification of Sauter mean diameter distributions using the scattering–absorption measurement ratio technique has been previously introduced and demonstrated in diesel sprays using the Engine Combustion Network Spray D injector; however, a more detailed treatment of measurement uncertainties has been needed. In this work, we present a summary of the various sources of measurement uncertainty in the scattering–absorption measurement ratio diagnostic, like those due to the experimental setup, data processing methods, and theoretical assumptions, and assess how these sources of uncertainty affect the quantified Sauter mean diameter. The spatially resolved Sauter mean diameter measurements that result from the scattering–absorption measurement ratio diagnostic will be especially valuable to the engine modeling community for the quantitative validation of spray submodels in engine computational fluid dynamics codes. Careful evaluation and quantification of measurement uncertainties are important to support accurate model validation and to ensure the development of more predictive spray models.

42 ENGINEERING↗

Shipboard Sunphotometer Measurements of Aerosol Optical Depth Spectra and Columnar Water Vapor During ACE-2, and Comparison with Selected Land, Ship, Aircraft, and Satellite Measurements

Analyses of aerosol optical depth (AOD) and columnar water vapor (CWV) measurements acquired with NASA Ames Research Center's six-channel Airborne Tracking Sunphotometer (AATS-6) operated aboard the R/V (research vehicle) Professor Vodyanitskiy during the second Aerosol Characterization Experiment (ACE-2) are discussed. Data are compared with various in situ and remote measurements for selected cases. The focus is on 10 July, when the Pelican airplane flew within 70 km of the ship near the time of a NOAA (National Oceanographic and Atmospheric Administration)-14/AVHRR (Advanced Very High Resolution Radiometer) satellite overpass and AOD measurements with the 14-channel Ames Airborne Tracking Sunphotometer (AATS-14) above the marine boundary layer (MBL) permitted calculation of AOD within the MBL from the AATS-6 measurements. A detailed column closure test is performed for MBL AOD on 10 July by comparing the AATS-6 MBL AODs with corresponding values calculated by combining shipboard particle size distribution measurements with models of hygroscopic growth and radiosonde humidity profiles (plus assumptions on the vertical profile of the dry particle size distribution and composition). Large differences (30-80% in the mid-visible) between measured and reconstructed AODs are obtained, in large part because of the high sensitivity of the closure methodology to hygroscopic growth models, which vary considerably and have not been validated over the necessary range of particle size/composition distributions. The wavelength dependence of AATS-6 AODs is compared with the corresponding dependence of aerosol extinction calculated from shipboard measurements of aerosol size distribution and of total scattering measured by a shipboard integrating nephelometer for several days. Results are highly variable, illustrating further the great difficulty of deriving column values from point measurements. AATS-6 CWV values are shown to agree well with corresponding values derived from radiosonde measurements during eight soundings on seven days and also with values calculated from measurements taken on 10 July with the AATS-14 and the University of Washington Passive Humidigraph aboard the Pelican.

Livingston, John M.↗

The extended Bloch representation of quantum mechanics and the hidden-measurement solution to the measurement problem

A generalized Bloch sphere, in which the states of a quantum entity of arbitrary dimension are geometrically represented, is investigated and further extended, to also incorporate the measurements. This extended representation constitutes a general solution to the measurement problem, inasmuch it allows to derive the Born rule as an average over hidden-variables, describing not the state of the quantum entity, but its interaction with the measuring system. According to this modelization, a quantum measurement is to be understood, in general, as a tripartite process, formed by an initial deterministic decoherence-like process, a subsequent indeterministic collapse-like process, and a final deterministic purification-like process. We also show that quantum probabilities can be generally interpreted as the probabilities of a first-order non-classical theory, describing situations of maximal lack of knowledge regarding the process of actualization of potential interactions, during a measurement. - Highlights: • An extended Bloch representation of quantum measurements is given. • Quantum measurements are explained in terms of hidden-measurement interactions. • Quantum measurements are explained as tripartite processes. • The Born rule results from a universal average, over all possible measurement processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal measurement strategies for effective suppression of drift errors

Drifting of experimental setups with change in temperature or other environmental conditions is the limiting factor of many, if not all, precision measurements. The measurement error due to a drift is, in some sense, in-between random noise and systematic error. In the general case, the error contribution of a drift cannot be averaged out using a number of measurements identically carried out over a reasonable time. In contrast to systematic errors, drifts are usually not stable enough for a precise calibration. Here a rather general method for effective suppression of the spurious effects caused by slow drifts in a large variety of instruments and experimental setups is described. An analytical derivation of an identity, describing the optimal measurement strategies suitable for suppressing the contribution of a slow drift described with a certain order polynomial function, is presented. A recursion rule as well as a general mathematical proof of the identity is given. The effectiveness of the discussed method is illustrated with an application of the derived optimal scanning strategies to precise surface slope measurements with a surface profiler.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of two-photon exchange effect with CLAS

The structure of the proton is one the most important and most studied topics in nuclear physics. However, discrepant measurements of the proton's electromagnetic form factor ratio, G{sub E}/G{sub M}, seriously jeopardize a definitive understanding of the proton's structure. Measurements of G{sub E}G{sub M} using the Rosenbluth separation technique disagree with those using polarization transfer methods by about a factor of three at Q{sup 2{approx}}5.6 GeV{sup 2}. It has been hypothesized that this discrepancy is due to two-photon exchange (TPE) effects that are not part of the usual radiative corrections. Theoretical corrections for the TPE effect are difficult due to the fact that a large number of excited nucleon states can contribute to the process. However, the TPE effect can be directly determined by measuring the ratio of the positron-proton to electron-proton elastic scattering cross sections, R = {sigma}(e{sup +})/{sigma}(e{sup -}), as the TPE effect changes sign with respect to the charge of the incident particle. A brief test run of a modified beamline and the CLAS detector at Jefferson Lab has resulted in the most precise measurements of the R to date. We will present results from the test run covering Q{sup 2}<0.8 GeV{sup 2} and 0.78{<=}{epsilon}{<=}0.97. In addition, the test run demonstrated the feasibility of producing a mixed electron/positron beam of good quality so that the measurements can be extended up to Q{sup 2{approx}}3.0 GeV{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron temperature measurements inside the ablating plasma of gas-filled hohlraums at the National Ignition Facility

The first measurement of the electron temperature (T{sub e}) inside a National Ignition Facility hohlraum is obtained using temporally resolved K-shell X-ray spectroscopy of a mid-Z tracer dot. Both isoelectronic- and interstage-line ratios are used to calculate the local T{sub e} via the collisional–radiative atomic physics code SCRAM [Hansen et al., High Energy Density Phys 3, 109 (2007)]. The trajectory of the mid-Z dot as it is ablated from the capsule surface and moves toward the laser entrance hole (LEH) is measured using side-on x-ray imaging, characterizing the plasma flow of the ablating capsule. Data show that the measured dot location is farther away from the LEH in comparison to the radiation-hydrodynamics simulation prediction using HYDRA [Marinak et al., Phys. Plasmas 3, 2070 (1996)]. To account for this discrepancy, the predicted simulation T{sub e} is evaluated at the measured dot trajectory. The peak T{sub e}, measured to be 4.2 keV ± 0.2 keV, is ∼0.5 keV hotter than the simulation prediction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear chirped slope profile for spatial calibration in slope measuring deflectometry

Slope measuring deflectometry is commonly used by the X-ray optics community to measure the long-spatial-wavelength surface figure error of optical components dedicated to guide and focus X-rays under grazing incidence condition at synchrotron and free electron laser beamlines. The best performing instruments of this kind are capable of absolute accuracy on the level of 30-50 nrad. However, the exact bandwidth of the measurements, determined at the higher spatial frequencies by the instrument’s spatial resolution, or more generally by the instrument’s modulation transfer function (MTF) is hard to determine. An MTF calibration method based on application of a test surface with a one-dimensional (1D) chirped height profile of constant amplitude was suggested in the past. In this work, we propose a new approach to designing the test surfaces with a 2D-chirped topography, specially optimized for MTF characterization of slope measuring instruments. The design of the developed MTF test samples based on the proposed linear chirped slope profiles (LCSPs) is free of the major drawback of the 1D chirped height profiles, where in the slope domain, the amplitude strongly increases with the local spatial frequency of the profile. We provide the details of fabrication of the LCSP samples. The results of first application of the developed test samples to measure the spatial resolution of the BESSY-NOM at different experimental arrangements are also presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross-section measurement and analysis for the {sup 149}Sm(n,alpha){sup 146}Nd reaction at 6.0 MeV

We have measured the {sup 149}Sm(n,alpha){sup 146}Nd cross section at 6.0 MeV to be 0.12+-0.018 mb. This is the first reported result for this cross section in the MeV region and so should be helpful for constraining nuclear data evaluations (which differ by a factor of 40 for this reaction at this energy) and for testing and improving nuclear models. The experiment was performed at the at the 4.5-MV Van de Graaff accelerator of Peking University. Neutrons were produced via the {sup 2}H(d,n){sup 3}He reaction using a deuterium gas target, and absolute neutron flux was determined with a small {sup 238}U fission chamber. Alpha particles were detected using a two-section gridded ionization chamber in which two large-area {sup 149}Sm{sub 2}O{sub 3} samples were placed back-to-back so that the cross section and forward/backward ratio were measured for nearly the entire 4pi solid angle. The data were compared to statistical-model predictions using the code talys. Good agreement between the measured and theoretical cross sections could be obtained with a small modification of the alpha-optical potential parameters from their default values in talys. However, we were not able to reproduce the measured forward/backward ratio. In addition, using the previously reported {sup 147}Sm(n,alpha){sup 144}Nd cross section at 6.0 MeV together with our new result, good agreement was found between the measured and predicted cross-section ratio for these two isotopes. Finally, none of the existing evaluated data libraries are in agreement with our new data to within the experimental uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temperature Measurements in the Magnetic Measurement Facility

Several key LCLS undulator parameter values depend strongly on temperature primarily because of the permanent magnet material the undulators are constructed with. The undulators will be tuned to have specific parameter values in the Magnetic Measurement Facility (MMF). Consequently, it is necessary for the temperature of the MMF to remain fairly constant. Requirements on undulator temperature have been established. When in use, the undulator temperature will be in the range 20.0 {+-} 0.2 C. In the MMF, the undulator tuning will be done at 20.0 {+-} 0.1 C. For special studies, the MMF temperature set point can be changed to a value between 18 C and 23 C with stability of {+-}0.1 C. In order to ensure that the MMF temperature requirements are met, the MMF must have a system to measure temperatures. The accuracy of the MMF temperature measurement system must be better than the {+-}0.1 C undulator tuning temperature tolerance, and is taken to be {+-}0.01 C. The temperature measurement system for the MMF is under construction. It is similar to a prototype system we built two years ago in the Sector 10 alignment lab at SLAC. At that time, our goal was to measure the lab temperature to {+-}0.1 C. The system has worked well for two years and has maintained its accuracy. For the MMF system, we propose better sensors and a more extensive calibration program to achieve the factor of 10 increase in accuracy. In this note we describe the measurement system under construction. We motivate our choice of system components and give an overview of the system. Most of the software for the system has been written and will be discussed. We discuss error sources in temperature measurements and show how these errors have been dealt with. The calibration system is described in detail. All the LCLS undulators must be tuned in the Magnetic Measurement Facility at the same temperature to within {+-}0.1 C. In order to ensure this, we are building a system to measure the temperature of the undulators to {+-}0.01 C. This note describes the temperature measurement system under construction.

43 PARTICLE ACCELERATORS↗

Measurement of inclusive jet and dijet cross-sections in proton-proton collisions at $$ \sqrt{s}=13 $$ TeV with the ATLAS detector

Inclusive jet and dijet cross-sections are measured in proton-proton collisions at a centre-of-mass energy of 13 TeV. The measurement uses a dataset with an integrated luminosity of 3.2 fb -1 recorded in 2015 with the ATLAS detector at the Large Hadron Collider. Jets are identified using the anti- k t algorithm with a radius parameter value of R = 0 . 4. The inclusive jet cross-sections are measured double-differentially as a function of the jet transverse momentum, covering the range from 100 GeV to 3.5 TeV, and the absolute jet rapidity up to | y | = 3. The double-differential dijet production cross-sections are presented as a function of the dijet mass, covering the range from 300 GeV to 9 TeV, and the half absolute rapidity separation between the two leading jets within | y | < 3, y * , up to y * = 3. Next-to-leading-order, and next-to-next-to-leading-order for the inclusive jet measurement, perturbative QCD calculations corrected for non-perturbative and electroweak effects are compared to the measured cross-sections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of charm and beauty production at central rapidity versus charged-particle multiplicity in proton-proton collisions at $ \sqrt{s}=7 $ TeV

Prompt D meson and non-prompt J/ψ yields are studied as a function of the multiplicity of charged particles produced in inelastic proton-proton collisions at a centre-of-mass energy of √s = 7 TeV. The results are reported as a ratio between yields in a given multiplicity interval normalised to the multiplicity-integrated ones (relative yields). They are shown as a function of the multiplicity of charged particles normalised to the average value for inelastic collisions (relative charged-particle multiplicity). D 0 , D + and D *+ mesons are measured in five p T intervals from 1 GeV/c to 20 GeV/c and for |y| < 0.5 via their hadronic decays. The D-meson relative yield is found to increase with increasing charged-particle multiplicity. For events with multiplicity six times higher than the average multiplicity of inelastic collisions, a yield enhancement of a factor about 15 relative to the multiplicity-integrated yield in inelastic collisions is observed. The yield enhancement is independent of transverse momentum within the uncertainties of the measurement. The D0-meson relative yield is also measured as a function of the relative multiplicity at forward pseudo-rapidity. The non-prompt J/ψ, i.e. the B hadron, contribution to the inclusive J/ψ production is measured in the di-electron decay channel at central rapidity. It is evaluated for p T > 1.3 GeV/c and |y| < 0.9, and extrapolated to p T > 0. The fraction of non-prompt J/ψ in the inclusive J/ψ yields shows no dependence on the charged-particle multiplicity at central rapidity. Charm and beauty hadron relative yields exhibit a similar increase with increasing charged-particle multiplicity. The measurements are compared to PYTHIA 8, EPOS 3 and percolation calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development and evaluation of a list mode neutron coincidence collar for spatial response measurements of fresh fuel assemblies

A traditional safeguards neutron coincidence counting system, the Neutron Coincidence Collar, has been modified to incorporate individual preamplifiers on each of its 18 3He tubes in active interrogation mode. When used with list mode data acquisition (LMDA) and analysis, a signal from each 3He tube can be recorded and analyzed to allow a spatial response measurement to be performed on an item based on count rate and 3He tube location within the system. The ultimate goal of this project is to demonstrate the capabilities of a list mode response matrix for the nondestructive assay of fresh nuclear fuel assemblies. To enable partial defect detection of fuel pin locations and absences within an assembly, the project aims to extend well-established correlated neutron analysis techniques on a preexisting Neutron Coincidence Collar by extracting a greater number of useful signatures from the system than are currently generated. LMDA, combined with the addition of multiple preamplifiers, facilitates this capability by increasing the number of simultaneous signals that can be measured; this allows an in-depth analysis of neutron coincidence events to determine a fissioning item’s location based on the measured doubles count rate in various channel logic coincidence combinations. All of this can be done from a single measurement pulse train in offline analysis, which is the major benefit provided by LMDA. Through various stages of development and testing, a Mirion Technologies model JCC-71 Neutron Coincidence Collar has been successfully retrofit with modern electronics designed in-house at Oak Ridge National Laboratory, matching preexisting JAB-01 electronics performance, while maintaining the original system footprint. This paper presents these various stages of development and experimental evaluation of the proof of concept system.

Moore, Angela S.↗

Measuring solar reflectance - Part II: Review of practical methods

A companion article explored how solar reflectance varies with surface orientation and solar position, and found that clear sky air mass 1 global horizontal (AM1GH) solar reflectance is a preferred quantity for estimating solar heat gain. In this study we show that AM1GH solar reflectance R{sub g,0} can be accurately measured with a pyranometer, a solar spectrophotometer, or an updated edition of the Solar Spectrum Reflectometer (version 6). Of primary concern are errors that result from variations in the spectral and angular distributions of incident sunlight. Neglecting shadow, background and instrument errors, the conventional pyranometer technique can measure R{sub g,0} to within 0.01 for surface slopes up to 5:12 [23 ], and to within 0.02 for surface slopes up to 12:12 [45 ]. An alternative pyranometer method minimizes shadow errors and can be used to measure R{sub g,0} of a surface as small as 1 m in diameter. The accuracy with which it can measure R{sub g,0} is otherwise comparable to that of the conventional pyranometer technique. A solar spectrophotometer can be used to determine R{sub g,0}{sup *}, a solar reflectance computed by averaging solar spectral reflectance weighted with AM1GH solar spectral irradiance. Neglecting instrument errors, R{sub g,0}{sup *} matches R{sub g,0} to within 0.006. The air mass 1.5 solar reflectance measured with version 5 of the Solar Spectrum Reflectometer can differ from R{sub g,0}{sup *} by as much as 0.08, but the AM1GH output of version 6 of this instrument matches R{sub g,0}{sup *} to within about 0.01. (author)

14 SOLAR ENERGY↗

Direct Measurement of the Tunable Electronic Structure of Bilayer MoS 2 by Interlayer Twist

Using angle-resolved photoemission on micrometer-scale sample areas, we directly measure the interlayer twist angle-dependent electronic band structure of bilayer molybdenum-disulfide (MoS 2 ). Our measurements, performed on arbitrarily stacked bilayer MoS 2 flakes prepared by chemical vapor deposition, provide direct evidence for a downshift of the quasiparticle energy of the valence band at the Brillouin zone center ($\bar{Γ}$ point) with the interlayer twist angle, up to a maximum of 120 meV at a twist angle of ~40°. Our direct measurements of the valence band structure enable the extraction of the hole effective mass as a function of the interlayer twist angle. While our results at $\bar{Γ}$agree with recently published photoluminescence data, our measurements of the quasiparticle spectrum over the full 2D Brillouin zone reveal a richer and more complicated change in the electronic structure than previously theoretically predicted. The electronic structure measurements reported here, including the evolution of the effective mass with twist-angle, provide new insight into the physics of twisted transition-metal dichalcogenide bilayers and serve as a guide for the practical design of MoS 2 optoelectronic and spin-/valley-tronic devices.

36 MATERIALS SCIENCE↗

Measurement of parity violation in electron–quark scattering

Symmetry permeates nature and is fundamental to all laws of physics. One example is parity (mirror) symmetry, which implies that flipping left and right does not change the laws of physics. Laws for electromagnetism, gravity and the subatomic strong force respect parity symmetry, but the subatomic weak force does not1, 2. Historically, parity violation in electron scattering has been important in establishing (and now testing) the standard model of particle physics. One particular set of quantities accessible through measurements of parity-violating electron scattering are the effective weak couplings C2q, sensitive to the quarks’ chirality preference when participating in the weak force, which have been measured directly3, 4 only once in the past 40 years. Here we report a measurement of the parity-violating asymmetry in electron–quark scattering, which yields a determination of 2C2u-C2d (where u and d denote up and down quarks, respectively) with a precision increased by a factor of five relative to the earlier result. These results provide evidence with greater than 95 per cent confidence that the C2q couplings are non-zero, as predicted by the electroweak theory. They lead to constraints on new parity-violating interactions beyond the standard model, particularly those due to quark chirality. Whereas contemporary particle physics research is focused on high-energy colliders such as the Large Hadron Collider, our results provide specific chirality information on electroweak theory that is difficult to obtain at high energies. Our measurement is relatively free of ambiguity in its interpretation, and opens the door to even more precise measurements in the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Qweak experiment: a precision measurement of the proton's weak charge

The Qweak experiment will conduct the first precision measurement of the weak charge of the proton, Q{sub W}{sup p}, at Jefferson Laboratory, building on the technical advances that have been made in the laboratory's parity-violation program and using the results of earlier measurements to constrain hadronic corrections. When the results from this measurement are combined with atomic-parity violation and other PVES measurements the weak charges of the 'up' and 'down' quarks can be extracted. The experiment is basically a measurement of the parity-violating longitudinal analyzing power in e-p elastic scattering at Q{sup 2} = 0.026 (GeV/c){sup 2} employing 150 {mu}A's of 85% polarized electrons on a 0.35 m long liquid hydrogen target. The experiment will determine the weak charge of the proton with about 4.1% combined statistical and systematic errors. This corresponds to constraints on parity violating new physics at a mass scale of 2.3 TeV at the 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A synthetic diagnostic for validation of electron gyroradius scale turbulence simulations against coherent scattering measurements

Comparison between spectra of short-scale density fluctuations measured with coherent electromagnetic scattering experiments and those extracted from space-resolved numerical simulations is affected by a number of systematic errors. These include the locality of scattering measurements, the different domain covered (space-resolved simulations versus wavenumber resolved measurements), and the stationarity of simulated nonlinear spectra. To bridge the gap between theory-simulations and experiments, a synthetic diagnostic for high- k scattering measurements has been developed. This synthetic scattering predicts the propagation of the beam in an anisotropic, inhomogeneous plasma and accounts for the spatial variation of the instrumental transfer function. Here the latter, in particular, is proven to provide an important calibration factor not only for the simulated spectra, but also for the measured ones, allowing the use of the synthetic diagnostic in predictive mode. Results from a case study for National Spherical Torus Experiment plasmas using high- k</em. tangential scattering system and the gyrokinetic tokamak simulation code are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗