Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurements and characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Novel Method for Characterization of Superconductors: Physical Measurements and Modeling of Thin Films

A method for characterization of granular superconducting thin films has been developed which encompasses both the morphological state of the sample and its fabrication process parameters. The broad scope of this technique is due to the synergism between experimental measurements and their interpretation using numerical simulation. Two novel technologies form the substance of this system: the magnetically modulated resistance method for characterizing superconductors; and a powerful new computer peripheral, the Parallel Information Processor card, which provides enhanced computing capability for PC computers. This enhancement allows PC computers to operate at speeds approaching that of supercomputers. This makes atomic scale simulations possible on low cost machines. The present development of this system involves the integration of these two technologies using mesoscale simulations of thin film growth. A future stage of development will incorporate atomic scale modeling.

Kim, B. F.↗

Land-based wind plant wake characterization using dual-Doppler radar measurements at AWAKEN

Wind plant wakes have been shown to persist for tens of kilometers downstream in offshore environments, reducing the power output of neighboring plants, but their behavior on land remains relatively unexplored through observation. This study capitalizes on the unique and extensive field data collected for the American WAKE ExperimeNt (AWAKEN) project underway in northern Oklahoma. X-band dual-Doppler radars deployed at this site measure wind speed and direction at 25-m and 2-min resolution within a 30-km range, capturing the interactions between three neighboring wind plants. These measurements show that the wake of one wind plant extends at least 15 km downstream under easterly wind and stable atmospheric conditions. Though the wake wind speed increases within the first 10 km, it plateaus at 90% of the freestream wind speed. The spanwise velocity distribution within the wake initially shows the clear signature of the wind plant layout, which is smoothed as it propagates downstream, indicating spanwise momentum transfer is a key mechanism in wind plant wake development and recovery. These findings have important implications for wind plant siting decisions and resource assessments, and provide insights into atmospheric interactions at the wind plant scale.

17 WIND ENERGY↗

Radiological Characterization of Hard to Measure Nuclides Using Accelerator Mass Spectrometry (AMS) - 20140

In this project irradiated heavy concrete was characterized regarding hard to measure nuclides like Ca-41 using Accelerator Mass Spectrometry (AMS). Concrete samples were irradiated with a known neutron flux and the Ca-41 content was investigated via AMS measurements. The comparison of the results with calculations shows a very good agreement in the Ca-41 content. The project revealed that AMS can be used to characterize irradiated concrete and contributes to improve the methodological basis of the radiological characterization and to extending the validation of nuclide vectors. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating the Utility of Pressure Scanners for Unsteady Pressure Measurements in Wind Tunnel Characterization of the Space Launch System

In many aerodynamic measurement applications, the ability to make time-accurate measurements with pressure scanners provides practical advantages over making the same measurements directly using flush-mounted transducers. The pneumatic distortion due to the tubing between the sensing module and surface port limits the usefulness of such measurements to averaged, steady data only. This issue has restricted the application of pressure scanners for unsteady pressure measurements in wind tunnel and flight-testing applications. The Wiener-filtered inverse system response model has been proven to be effective in reconstructing complex unsteady pressure signals acquired remotely using pressure scanners. In this work, the feasibility of using pressure scanning systems for time-resolved pressure measurements in the NASA Langley 14- by 22-Foot Subsonic Wind Tunnel was evaluated. Results demonstrated good agreement between the reference transducers and reconstructed pressure scanner measurements up to frequencies of approximately 500 Hz.

Unsteady pressure↗

Computer signal processing for ultrasonic attenuation and velocity measurements for material property characterizations

This report deals with instrumentation and computer programming concepts that have been developed for ultrasonic materials characterization. Methods that facilitate velocity and attenuation measurements are described. The apparatus described is based on a broadband, buffered contact probe using a pulse-echo approach for simultaneously measuring velocity and attenuation. Instrumentation, specimen condition, and signal acquisition and acceptance criteria are discussed. Typical results with some representative materials are presented.

Vary, A.↗

Characterization and Absolute QE Measurements of Delta-Doped N-Channel and P-Channel CCDs

In this paper we present the methodology for making absolute quantum efficiency (QE) measurements from the vacuum ultraviolet (VUV) through the near infrared (NIR) on delta-doped silicon CCDs. Delta-doped detectors provide an excellent platform to validate measurements through the VUV due to their enhanced UV response. The requirements for measuring QE through the VUV are more strenuous than measurements in the near UV and necessitate, among other things, the use of a vacuum monochromator, and good camera vacuum to prevent chip condensation, and more stringent handling requirements. The system used for these measurements was originally designed for deep UV characterization of CCDs for the WF/PC instrument on Hubble and later for Cassini CCDs.

Jacquot, Blake C.↗

Hydraulic fracture mapping using wavelet-based fusion of wave transmission and emission measurements

Fracture characterization is essential to hydrocarbon and geothermal exploration and production as well as carbon geo-sequestration. Active and passive measurements have been extensively applied to map fractures across various scales. Active and passive methods have inherent advantages and limitations that complement each other. Here, in this study, to improve the mapping of embedded fractures and the surrounding geomechanically altered regions, we integrate active shear-wave transmission measurement with passive acoustic-emission measurement collected during a lab-scale hydraulic-fracturing experiment. The proposed data fusion leverages the advantages of the two modalities of measurements, while minimizing their individual limitations. Polarized shear-wave transmission (active) measurement was collected before and after the hydraulic fracturing, and the acoustic emission (passive) measurement was collected during hydraulic fracturing. Two sets of two-dimensional maps of fracture and fracture-induced damage in axial, median and frontal planes were obtained by separately processing active and passive measurements. These 2D maps are then fed to wavelet-based image fusion technique to integrate the two sources of information for the reliable mapping/imaging of the embedded fractures and the surrounding geomechanically altered regions.

58 GEOSCIENCES↗

Metrics of Balance Control for Use in Screening Tests of Vestibular Function

Decrements in balance control have been documented in astronauts after space flight. Reliable measures of balance control are needed for use in postflight field tests at remote landing sites. Diffusion analysis (DA) is a statistical mechanical tool that shows the average difference of the dependent variable on varying time scales. These techniques have been shown to measure differences in open-loop and closed-loop postural control in astronauts and elderly subjects. The goal of this study was to investigate the reliability of these measures of balance control. Eleven subjects were tested using the Clinical Test of Sensory Interaction on Balance: the subject stood with feet together and arms crossed on a stable or compliant surface, with eyes open or closed and with or without head movements in the pitch or yaw plane. Subjects were instrumented with inertial motion sensors attached to their trunk segment. The DA curves for linear acceleration measures were characterized by linear fits measuring open- (Ds) and closed-loop (Dl) control, and their intersection point (X-int, Y-int). Ds and Y-int showed significant differences between the test conditions. Additionally, Ds was correlated with the root mean square (RMS) of the signal, indicating that RMS was dominated by open-loop events (< 0.5 seconds). The Y-int was found to be correlated with the average linear velocity of trunk movements. Thus DA measures could be applied to derive reliable metrics of balance stability during field tests.

Fiedler, Matthew↗

Computer signal processing for ultrasonic attenuation and velocity measurements for material property characterizations

Instrumentation and computer programming concepts that were developed for ultrasonic materials characterization are described. Methods that facilitate velocity and attenuation measurements are outlined. The apparatus described is based on a broadband, buffered contact probe using a pulse-echo approach for simultaneously measuring velocity and attenuation. Instrumentation, specimen condition, and signal acquisition and acceptance criteria are discussed. Typical results with some representative materials are presented.

Vary, A.↗

Analytical ultrasonics for structural materials

The application of ultrasonic velocity and attenuation measurements to characterize the microstructure of structural materials is discussed. Velocity measurements in cast stainless steel are correlated with microstructural variations ranging from equiaxed (elastically isotropic) to columnar (elastically anisotropic) grain structure. The effect of the anisotropic grain structure on the deviation of ultrasonic waves in cast stainless steel is also reported. Field-implementable techniques for distinguishing equiaxed from columnar grain structures in cast strainless steel structural members are presented. The application of ultrasonic velocity measurements to characterize structural ceramics in the green state is also discussed.

Kupperman, D. S.↗

A new technique to retrieve aerosol vertical profiles using micropulse lidar and ground-based aerosol measurements

Accurately characterizing the vertical distribution of aerosols and their cloud-forming properties is crucial for understanding aerosol-cloud interactions and their impact on climate. This study presents a novel technique for retrieving vertical profiles of aerosols, cloud condensation nuclei (CCN), and ice nucleating particles (INP) by combining micropulse lidar, radiosonde, and ground-based aerosol measurements. Herein, the technique is applied to data collected by our team at Texas A&M University during the Tracking Aerosol Convection Interactions ExpeRiment (TRACER) campaign. Ground-based aerosol size distribution and CCN counter data are used to estimate the value of the aerosol hygroscopicity parameter, κ. The derived κ, together with Mie scattering theory and the relative humidity profile from the radiosonde, is used to estimate aerosol size growth and the associated increase in backscatter at each altitude. We then correct the lidar backscatter to dry conditions to produce the dry aerosol backscatter coefficient profile. The dry aerosol backscatter coefficient profile is linearly scaled to collocated surface measurements of aerosols, CCN, and INP to produce corresponding vertical profiles. Combining lidar backscatter profiles with aerosol and cloud nucleation measurements leads to a more realistic representation of vertical distributions of aerosol properties. The method could be readily applied to lidar measurements in future field campaigns.

Chen, Bo [Texas A & M Univ., College Station, TX (↗

Characterization of Orbital Debris Photometric Properties Derived from Laboratory-Based Measurements

To better characterize and model optical data acquired from ground-based telescopes, the Optical Measurements Center (OMC) at NASA/JSC attempts to emulate illumination conditions seen in space using equipment and techniques that parallel telescopic observations and source-target-sensor orientations. The OMC uses a 75 Watt Xenon arc lamp as a solar simulator, an SBIG CCD camera with standard Johnson/Bessel filters, and a robotic arm to simulate an object's position and rotation. The laboratory uses known shapes, materials suspected to be consistent with the orbital debris population, and three phase angles to best match the lighting conditions of the telescope based data. The fourteen objects studied in the laboratory are fragments or materials acquired through ground-tests of scaled-model satellites/rocket bodies as well as material samples in more/less "flight-ready" condition. All fragments were measured at 10 increments in a full 360 rotation at 6 , 36 , and 60 phase angles. This paper will investigate published color photometric data for a series of orbital debris targets and compare it to the empirical photometric measurements generated in the OMC. Using the data acquired over specific rotational angles through different filters (B, V, R, I), a color index is acquired (B-R, R-I). Using these values and their associated lightcurves, this laboratory data is compared to observational data obtained on the 1 m telescope of the Astronomical Institute of the University of Bern (AUIB), the 0.9 m operated by the Small- and Medium-Aperture Research Telescope System (SMARTS) Consortium and the Curtis-Schmidt 0.6 m Michigan Orbital Debris Space Debris Telescope both located at Cerro Tololo Inter-American Observatory (CTIO). An empirical based optical characterization model will be presented to provide preliminary correlations between laboratory based and telescope-based data in the context of classification of GEO debris objects.

Cowardin, H.↗

CTS/Comstar communications link characterization experiment

Measurements of angle of arrival and amplitude fluctuations on millimeter wavelength Earth-space communication links are described. Measurement of rainfall attenuation and radiometric temperature statistics and the assessment of the performance of a self-phased array as a receive antenna on an Earth-space link are also included.

Hodge, D. B.↗

Remote gate capacitance-voltage studies for noninvasive surface characterization

A measurement technique has been developed which allows noncontact capacitance-voltage measurements to be made using a gate electrode located remote from the semiconductor surface under study. With gate electrodes about 0.5 mm in diameter and gate to semiconductor separations of about 1500 A, it was possible to generate data entirely comparable to that obtained with integrated MIS structures but with the advantage that there was access directly to the free-semiconductor surface. This technique was applied to bulk single-crystal Si and InP samples.

Chang, R. R.↗

Spectra-to-exposure conversion using polynomial response models for gamma-ray field characterization

Accurate measurement of exposure rate from gamma-ray spectral data remains a critical challenge during radiological emergency response operations. Conventional methods rely on pre-defined static conversion factors derived from fixed geometries and isotopic compositions, which often fail to capture real-world environmental variability. This study presents a generalized approach as a "next-step" for converting gamma-ray spectral data into exposure rate using polynomial response models. The method introduces a flexible weighting scheme based on the in-situ detector response to distributed sources, enabling a pathway towards improved correspondence between measured spectra and "ground-truth" exposure rates. Experimental data from sodium iodide NaI(Tl) detectors were used to validate the approach as, at least equivalent to the current count-to-exposure method employed in emergency response CONOPS. Results show that the polynomial weighting model is sufficiently equal to the count-to-exposure method and may help improve accuracy given its adaptability to real-world conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Rotating-Coil Measurement System for Small-Bore-Diameter Magnet Characterization

Rotating-coil measurement systems are widely used to measure the multipolar fields of particle accelerator magnets. This paper presents a rotating-coil measurement system that aims at providing a complete data set for the characterization of quadrupole magnets with small bore diameters (26 mm). The PCB magnetometer design represents a challenging goal for this type of transducer. It is characterized by an aspect ratio 30% higher than the state of the art, imposed by the reduced dimension of the external radius of the rotating shaft and the necessity of covering the entire magnet effective length (500 mm or higher). The system design required a novel design for the mechanical asset, also considering the innovation represented by the commercial carbon fiber tube, housing the PCB magnetometer. Moreover, the measurement system is based primarily on standard and commercially available components, with simplified control and post-processing software applications. The system and its components are cross-calibrated using a stretched-wire system and another rotating-coil system. The measurement precision is established in a measurement campaign performed on a quadrupole magnet characterized by an inner bore diameter of 45 mm.

42 ENGINEERING↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗

Biogeochemical cycling in terrestrial ecosystems - Modeling, measurement, and remote sensing

The use of modeling, remote sensing, and measurements to characterize the pathways and to measure the rate of biogeochemical cycling in forest ecosystems is described. The application of the process-level model to predict processes in intact forests and ecosystems response to disturbance is examined. The selection of research areas from contrasting climate regimes and sites having a fertility gradient in that regime is discussed, and the sites studied are listed. The use of remote sensing in determining leaf area index and canopy biochemistry is analyzed. Nitrous oxide emission is investigated by using a gas measurement instrument. Future research projects, which include studying the influence of changes on nutrient cycling in ecosystems and the effect of pollutants on the ecosystems, are discussed.

Peterson, D. L.↗