Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Skylab water balance error analysis

Estimates of the precision of the net water balance were obtained for the entire Skylab preflight and inflight phases as well as for the first two weeks of flight. Quantitative estimates of both total sampling errors and instrumentation errors were obtained. It was shown that measurement error is minimal in comparison to biological variability and little can be gained from improvement in analytical accuracy. In addition, a propagation of error analysis demonstrated that total water balance error could be accounted for almost entirely by the errors associated with body mass changes. Errors due to interaction between terms in the water balance equation (covariances) represented less than 10% of the total error. Overall, the analysis provides evidence that daily measurements of body water changes obtained from the indirect balance technique are reasonable, precise, and relaible. The method is not biased toward net retention or loss.

Leonard, J. I.↗

Relative tracking of multiple spacecraft by interferometry

An analysis is conducted of earth-based radiometric tracking of one spacecraft relative to an angularly nearby second spacecraft. Two cases are studied: relative positioning between a lander and a rover on the surface of Mars and relative tracking between a Mars lander and a Mars orbiter. All spacecraft signals are simultaneously received in the same beamwidth of an earth tracking antenna. Differential interferometric measurement errors are predicted. Errors which scale with angular separation between sources and errors which scale with temporal separation between measurement epochs are reduced virtually to zero. System thermal noise and systematic phase shifts introduced by receiver electronics typically dominate the error budget. Solar plasma delays become dominant for signal paths which pass close to the sun. Precise line-of-sight range measurements, differenced between stations, are also considered. Meter-level accuracy is obtained for lander/rover relative position by combining interferometric and precise range measurements. Either data type alone, for geometries where earth is not near zero declination as seen from Mars and Mars is not near zero declination as seen from earth, can provide accuracy at the 10-100-m level.

Border, James S.↗

An Exploratory Statistical Analysis of a Planet Approach-Phase Guidance Scheme Using Angular Measurements with Significant Error

An exploratory analysis of vehicle guidance during the approach to a target planet is presented. The objective of the guidance maneuver is to guide the vehicle to a specific perigee distance with a high degree of accuracy and minimum corrective velocity expenditure. The guidance maneuver is simulated by considering the random sampling of real measurements with significant error and reducing this information to prescribe appropriate corrective action. The instrumentation system assumed includes optical and/or infrared devices to indicate range and a reference angle in the trajectory plane. Statistical results are obtained by Monte-Carlo techniques and are shown as the expectation of guidance accuracy and velocity-increment requirements. Results are nondimensional and applicable to any planet within limits of two-body assumptions. The problem of determining how many corrections to make and when to make them is a consequence of the conflicting requirement of accurate trajectory determination and propulsion. Optimum values were found for a vehicle approaching a planet along a parabolic trajectory with an initial perigee distance of 5 radii and a target perigee of 1.02 radii. In this example measurement errors were less than i minute of arc. Results indicate that four corrections applied in the vicinity of 50, 16, 15, and 1.5 radii, respectively, yield minimum velocity-increment requirements. Thrust devices capable of producing a large variation of velocity-increment size are required. For a vehicle approaching the earth, miss distances within 32 miles are obtained with 90-percent probability. Total velocity increments used in guidance are less than 3300 feet per second with 90-percent probability. It is noted that the above representative results are valid only for the particular guidance scheme hypothesized in this analysis. A parametric study is presented which indicates the effects of measurement error size, initial perigee, and initial energy on the guidance requirements. Measurement error size significantly affects both guidance accuracy and velocity-increment expenditure. The initial trajectory, as given by its perigee and energy, affects the velocity-increment expenditure but not final guidance accuracy.

Friedlander, Alan L.↗

One way Doppler extractor. Volume 1: Vernier technique

A feasibility analysis, trade-offs, and implementation for a One Way Doppler Extraction system are discussed. A Doppler error analysis shows that quantization error is a primary source of Doppler measurement error. Several competing extraction techniques are compared and a Vernier technique is developed which obtains high Doppler resolution with low speed logic. Parameter trade-offs and sensitivities for the Vernier technique are analyzed, leading to a hardware design configuration. A detailed design, operation, and performance evaluation of the resulting breadboard model is presented which verifies the theoretical performance predictions. Performance tests have verified that the breadboard is capable of extracting Doppler, on an S-band signal, to an accuracy of less than 0.02 Hertz for a one second averaging period. This corresponds to a range rate error of no more than 3 millimeters per second.

Blasco, R. W.↗

One-way Doppler extractor

This paper presents a feasibility analysis, tradeoffs, and implementation for a one-way Doppler extractor system. A Doppler error analysis is discussed which shows that quantization error is a primary source of Doppler measurement error. Several competing extraction techniques are compared, and a 'Vernier' technique is presented which obtains high Doppler resolution with low-speed logic. Parameter tradeoffs and sensitivities for this Vernier technique are discussed, leading to a hardware design configuration. Also presented is a performance evaluation of the resulting breadboard model that verifies the theoretical performance predictions. The breadboard model contains the circuitry to interface with an S-band transponder, to extract the Doppler and time-interval counts, to compute navigational parameters by means of a microprocessor, and to display the results. Performance tests have verified that the breadboard is capable of extracting Doppler, on an S-band signal, to an accuracy of better than 0.02 hertz for a one-second averaging period. This corresponds to a range rate error of no more than 3 millimeters per second.

Nossen, E. J.↗

Water vapor measurement system in global atmospheric sampling program, appendix

The water vapor measurement system used in the NASA Global Atmospheric Sampling Program (GASP) is described. The system used a modified version of a commercially available dew/frostpoint hygrometer with a thermoelectrically cooled mirror sensor. The modifications extended the range of the hygrometer to enable air sample measurements with frostpoint temperatures down to -80 C at altitudes of 6 to 13 km. Other modifications were made to permit automatic, unattended operation in an aircraft environment. This report described the hygrometer, its integration with the GASP system, its calibration, and operational aspects including measurement errors. The estimated uncertainty of the dew/frostpoint measurements was + or - 1.7 Celsius.

Englund, D. R.↗

Psychophysical rating of image compression techniques

Image compression schemes abound with little work which compares their bit-rate performance based on subjective fidelity measures. Statistical measures of image fidelity, such as squared error measures, do not necessarily correspond to subjective measures of image fidelity. Most previous comparisons of compression techniques have been based on these statistical measures. A psychophysical method has been used to estimate, for a number of compression techniques, a threshold bit-rate yielding a criterion level of performance in discriminating original and compressed images. The compression techniques studied include block truncation, Laplacian pyramid, block discrete cosine transform, with and without a human visual system scaling, and cortex transform coders.

Stein, Charles S.↗

Parallel computers - Estimate errors caused by imprecise data

A new approach to the problem of estimating errors caused by imprecise data is proposed in the context of software engineering. A software device is used to produce an ideal solution to the problem, when the computer is capable of computing errors of arbitrary programs. The software engineering aspect of this problem is to describe a device for computing the error estimates in software terms and then to provide precise numbers with error estimates to the user. The feasibility of the program capable of computing both some quantity and its error estimate in the range of possible measurement errors is demonstrated.

Kreinovich, Vladik↗

The effect of sensor sheltering and averaging techniques on wind measurements at the Shuttle Landing Facility

This document presents results of a field study of the effect of sheltering of wind sensors by nearby foliage on the validity of wind measurements at the Space Shuttle Landing Facility (SLF). Standard measurements are made at one second intervals from 30-feet (9.1-m) towers located 500 feet (152 m) from the SLF centerline. The centerline winds are not exactly the same as those measured by the towers. A companion study, Merceret (1995), quantifies the differences as a function of statistics of the observed winds and distance between the measurements and points of interest. This work examines the effect of nearby foliage on the accuracy of the measurements made by any one sensor, and the effects of averaging on interpretation of the measurements. The field program used logarithmically spaced portable wind towers to measure wind speed and direction over a range of conditions as a function of distance from the obstructing foliage. Appropriate statistics were computed. The results suggest that accurate measurements require foliage be cut back to OFCM standards. Analysis of averaging techniques showed that there is no significant difference between vector and scalar averages. Longer averaging periods reduce measurement error but do not otherwise change the measurement in reasonably steady flow regimes. In rapidly changing conditions, shorter averaging periods may be required to capture trends.

Merceret, Francis J.↗

Infusing Statistical Thinking into the NASA Quesst Community Test Campaign

Statistical thinking permeates many important decisions as NASA plans its Quesst mission, which will culminate in a series of community overflights using the X-59 aircraft to demonstrate low-noise supersonic flight. Month-long longitudinal surveys will be deployed to assess human perception and annoyance to this new acoustic phenomenon. NASA works with a large contractor team to develop systems and methodologies to estimate noise doses, to test and field socio-acoustic surveys, and to study the relationship between the two quantities, dose and response, through appropriate choices of statistical models. This latter dose-response relationship will serve as an important tool as national and international noise regulators debate whether overland supersonic flights could be permitted once again within permissible noise limits. In this presentation we highlight several areas where statistical thinking has come into play, including issues of sampling, classification and data fusion, and analysis of longitudinal survey data that are subject to rare events and the consequences of measurement error. We note several operational constraints that shape the appeal or feasibility of some decisions on statistical approaches, and we identify several important remaining questions to be addressed.

Bayesian model↗

Uncertainty Analysis of Seebeck Coefficient and Electrical Resistivity Characterization

In order to provide a complete description of a materials thermoelectric power factor, in addition to the measured nominal value, an uncertainty interval is required. The uncertainty may contain sources of measurement error including systematic bias error and precision error of a statistical nature. The work focuses specifically on the popular ZEM-3 (Ulvac Technologies) measurement system, but the methods apply to any measurement system. The analysis accounts for sources of systematic error including sample preparation tolerance, measurement probe placement, thermocouple cold-finger effect, and measurement parameters; in addition to including uncertainty of a statistical nature. Complete uncertainty analysis of a measurement system allows for more reliable comparison of measurement data between laboratories.

Seebeck effect↗

Bias Reduction and Filter Convergence for Long Range Stereo

We are concerned here with improving long range stereo by filtering image sequences. Traditionally, measurement errors from stereo camera systems have been approximated as 3-D Gaussians, where the mean is derived by triangulation and the covariance by linearized error propagation. However, there are two problems that arise when filtering such 3-D measurements. First, stereo triangulation suffers from a range dependent statistical bias; when filtering this leads to over-estimating the true range. Second, filtering 3-D measurements derived via linearized error propagation leads to apparent filter divergence; the estimator is biased to under-estimate range. To address the first issue, we examine the statistical behavior of stereo triangulation and show how to remove the bias by series expansion. The solution to the second problem is to filter with image coordinates as measurements instead of triangulated 3-D coordinates.

robotics↗

A source of experimental underestimation of aerosol bolus deposition

We examined the measurement error in inhaled and exhaled aerosol concentration resulting from the bolus delivery system when small volumes of monodisperse aerosols are inspired to different lung depths. A laser photometer that illuminated approximately 75% of the breathing path cross section recorded low inhaled bolus half-widths (42 ml) and negative deposition values for shallow bolus inhalation when the inhalation path of a 60-ml aerosol was straight and unobstructed. We attributed these results to incomplete mixing of the inhaled aerosol bolus over the breathing path cross section, on the basis of simultaneous recordings of the photometer with a particle-counter sampling from either the center or the edge of the breathing path. Inserting a 90 degrees bend into the inhaled bolus path increased the photometer measurement of inhaled bolus half-width to 57 ml and yielded positive deposition values. Dispersion, which is predominantly affected by exhaled bolus half-width, was not significantly altered by the 90 degrees bend. We conclude that aerosol bolus-delivery systems should ensure adequate mixing of the inhaled bolus to avoid error in measurement of bolus deposition.

Non-NASA Center↗

Accuracy of earth albedo estimates from wide-angle radiation measurements

The instantaneous resolution and accuracy that can be expected from two inversion techniques to be used in the Earth Radiation Budget Experiment (ERBE) are examined. It is shown that measurement errors are magnified by the numerical filter and that this magnification is a function of the magnitude of the inversion factor. By using singular value decomposition, these magnitudes can be reduced to improve the estimates. A simulation of the estimation process using an albedo field derived from scanning radiometer data shows that retaining 6 of the 13 singular values gives the best results. If there are no bidirectional model errors the medium-field-of-view data give the best estimates. However, when bidirectional model errors are considered, the wide-field-of-view measurements give better estimates since they are less sensitive to these errors.

Green, R. N.↗

The impact of data density and data error on the evolution of mesoscale forecast error

The effects of data density and data errors on the accuracy of mesoscale weather forecasts were assessed by simulations of a period in February 1979 when a snowstorm occurred along the U.S. eastern seaboard. The simulations were initiated every 12 hr and the growth of the rms error was tracked as a function of time and varying data densities. A uniform grid of instrumentation separation and perfect boundary conditions were assumed for all the simulations. A bias error representation was defined to account for systematic measurement errors. A brief summary of features of the somewhat complex storm is provided, together with the parameters of the 11 different simulations with high, medium and low data densities. The accuracy of the forecasts were proportional to the data density, although the error decreased for all the simulations over a 24 hr period. The density of the vertical data had a significant impact on the accuracy of the forecast, whereas the horizontal data density did not. Finally, pathways by which errors were transferred among variables were identified.

Warner, T. T.↗

Single pulse vibrational Raman scattering by a broadband KrF excimer laser in a hydrogen-air flame

Spontaneous vibrational Raman scattering (VRS) is produced by a broadband excimer laser at 248 nm (KrF) in a H2-air flame, and VRS spectra are recorded for lean, stoichiometric, and rich flames. Except at very lean flame conditions, laser-induced fluorescence (LIF) processes interfere with VRS Stokes lines from H2, H2O, and O2. No interference is found for the N2 Stokes and N2 anti-Stokes lines. In a stoichiometric H2/air flame, single-pulse measurements of N2 concentration and temperature (by the VRS Stokes to anti-Stokes ratio) have a relative standard deviation of 7.7 and 10 percent, respectively. These single pulse measurement errors compare well with photon statistics calculations using measured Raman cross sections.

Pitz, Robert W.↗