Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Uncertainty Quantification for Empirical X-59 Sonic Boom Loudness Levels

Estimates of the total uncertainty for empirically determined loudness levels are documented when GRS (Ground Recording System) noise monitors are used to record X 59 sonic boom waveforms. The total uncertainty is characterized by combining nine different sources of uncertainty that may affect the apparent gain of the measurement chain. These uncertainty estimates are presented as expected measurement error relative to the true loudness level, and separate error estimates are provided for eight different noise metrics in which NASA has interest. The behavior of the Perceived Level (PL) metric is studied within the report body, while the total uncertainties for the seven other noise metrics are summarized in appendices for brevity. The effects of four sources of uncertainty are estimated simply from information found on hardware specification sheets provided by the manufacturer. However, mock acoustic recordings are created to estimate the effects of other sources because those effects are expected to induce spectral coloration, so they may vary with noise metric type and sound level. These sources are not well modeled by simple gain adjustments. Importantly, measurement error is computable when processing mock recordings since the true levels are knowable, which is not the case when processing data recorded in the field. Specifically, the true levels are knowable because the components of the mock recordings are separable – e.g., loudness levels of booms can be computed with or without superimposed background noise. Mock acoustic recordings also have the benefit of allowing analysis of sonic booms from vehicles that are not yet flying, like the X-59, since the mock recordings are created by combining vehicle-specific predicted waveforms with other audio sources. The estimates of total measurement error are documented as a function of the signal-to-noise ratio (SNR) of the loudness level, where the corrected SNR is computed while accounting for the effects of the method that is used to correct for background noise contamination when computing the noise metric values. The corrected SNR calculations used here can be applied to both mock recordings and in-field measurements, so the uncertainty of in-field recordings can be found using pre-computed lookup tables that identify the relationship between metric type, corrected SNR, and the expected measurement error.

Sonic Boom↗

Progress in Understanding Error-field Physics in NSTX Spherical Torus Plasmas

The low aspect ratio, low magnetic field, and wide range of plasma beta of NSTX plasmas provide new insight into the origins and effects of magnetic field errors. An extensive array of magnetic sensors has been used to analyze error fields, to measure error field amplification, and to detect resistive wall modes in real time. The measured normalized error-field threshold for the onset of locked modes shows a linear scaling with plasma density, a weak to inverse dependence on toroidal field, and a positive scaling with magnetic shear. These results extrapolate to a favorable error field threshold for ITER. For these low-beta locked-mode plasmas, perturbed equilibrium calculations find that the plasma response must be included to explain the empirically determined optimal correction of NSTX error fields. In high-beta NSTX plasmas exceeding the n=1 no-wall stability limit where the RWM is stabilized by plasma rotation, active suppression of n=1 amplified error fields and the correction of recently discovered intrinsic n=3 error fields have led to sustained high rotation and record durations free of low-frequency core MHD activity. For sustained rotational stabilization of the n=1 RWM, both the rotation threshold and magnitude of the amplification are important. At fixed normalized dissipation, kinetic damping models predict rotation thresholds for RWM stabilization to scale nearly linearly with particle orbit frequency. Studies for NSTX find that orbit frequencies computed in general geometry can deviate significantly from those computed in the high aspect ratio and circular plasma cross-section limit, and these differences can strongly influence the predicted RWM stability. The measured and predicted RWM stability is found to be very sensitive to the E × B rotation profile near the plasma edge, and the measured critical rotation for the RWM is approximately a factor of two higher than predicted by the MARS-F code using the semi-kinetic damping model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improving IPATS Channel-to-Channel Registration Assessment

The Image Navigation and Registration (INR) Performance Assessment Tool Set (IPATS) is a primary tool for assessing INR performance of GOES-R series ABI images. IPATS assesses five INR metrics: navigation, channel-to-channel registration (CCR), frame-to-frame registration, within-frame registration, and swath-to-swath registration. It was discovered that CCR assessment results between Visible-Near-Infrared (VNIR) channels and Infrared (IR) channels exhibits an annual oscillation in the north-south (NS) direction and a diurnal oscillation in the east-west (EW) direction, with an amplitude of approximately 5 μrad and 2.5 μrad, respectively. However, differences of navigation assessment results between VNIR and IR channels do not exhibit the annual or diurnal oscillations observed in CCR results. This indicates that the observed oscillations are due to measurement errors. The characteristics of the oscillations imply that cloud shadows are a possible cause of these measurement errors. In this study, several methods are explored to minimize the impact of cloud shadows on VNIR to IR CCR assessments: a) assessment at landmark locations only; b) using navigation assessment results to filter CCR assessments; c) using the ABI clear-sky-ratio product as a cloud mask; and d) smaller CCR assessment windows. In this paper, each method and a combination of several methods are evaluated based on assessment accuracy and the number of successful assessments. The selected approach is then used to reprocess GOES-16 ABI CCR data to show reductions in the annual and diurnal measurement error oscillations.

INR↗

A Predictive Attitude Determination Algorithm

In this paper, a new and efficient algorithm is developed for attitude determination from vector observations. The new algorithm, called the Predictive Attitude Determination (PAD) algorithm, is derived from a general nonlinear predictive filter approach. Traditional deterministic algorithms are shown to be suboptimal for anisotropic measurement errors. The major advantage of the PAD algorithm is that it can be easily applied to the case where anisotropic measurement errors exist. Also, an analytical expression is derived for the steady-state attitude error covariance, which is shown to be equivalent to the optimal covariance derived from maximum likelihood techniques. Simulation studies indicate that the new algorithm is able to accurately determine the attitude of a spacecraft, even for radically anisotropic measurement errors.

Markley, F. Landis↗

Repeatability of the Over-All Errors of an Airplane Altimeter Installation in Landing-Approach Operations

Flight tests have been conducted to determine the repeatability of the over-all altimetry errors in the landing-approach condition of two sensitive altimeters (Air Force type C-12) installed in the cockpit of a transport airplane and of four precision altimeters (Air Force type MA-1) installed in a photo-observer. Data were obtained through a speed range of 62 to 100 knots during 42 landing-approach operations conducted on four different days. The results of the tests show that the repeatability errors of the two sensitive altimeters are +/- 35 feet and +/- 39 feet. These errors are of the same order as the maximum repeatability error measured in previous tests of eleven airplanes of the same type. For each of the four flights of the present tests the mean values of the data obtained with the two sensitive altimeters shifted by relatively large amounts, apparently because of the interaction of the stability and aftereffect- recovery characteristics of the instruments. For concurrent measurements of the over-all errors of the four precision altimeters, it is concluded that for comparable installations, the repeatability errors measured with these altimeters would be smaller than those measured with the sensitive altimeters.

Gracey, William↗

Tests of the Tully-Fisher relation. 1: Scatter in infrared magnitude versus 21 cm width

We examine the precision of the Tully-Fisher relation (TFR) using a sample of galaxies in the Coma region of the sky, and find that it is good to 5% or better in measuring relative distances. Total magnitudes and disk axis ratios are derived from H and I band surface photometry, and Arecibo 21 cm profiles define the rotation speeds of the galaxies. Using 25 galaxies for which the disk inclination and 21 cm width are well defined, we find an rms deviation of 0.10 mag from a linear TFR with dI/d(log W(sub c)) = -5.6. Each galaxy is assumed to be at a distance proportional to its redshift, and an extinction correction of 1.4(1-b/a) mag is applied to the total I magnitude. The measured scatter is less than 0.15 mag using milder extinction laws from the literature. The I band TFR scatter is consistent with measurement error, and the 95% CL limits on the intrinsic scatter are 0-0.10 mag. The rms scatter using H band magnitudes is 0.20 mag (N = 17). The low width galaxies have scatter in H significantly in excess of known measurement error, but the higher width half of the galaxies have scatter consistent with measurement error. The H band TFR slope may be as steep as the I band slope. As the first applications of this tight correlation, we note the following: (1) the data for the particular spirals commonly used to define the TFR distance to the Coma cluster are inconsistent with being at a common distance and are in fact in free Hubble expansion, with an upper limit of 300 km/s on the rms peculiar line-of-sight velocity of these gas-rich spirals; and (2) the gravitational potential in the disks of these galaxies has typical ellipticity less than 5%. The published data for three nearby spiral galaxies with Cepheid distance determinations are inconsistent with our Coma TFR, suggesting that these local calibrators are either ill-measured or peculiar relative to the Coma Supercluster spirals, or that the TFR has a varying form in different locales.

Bernstein, Gary M.↗

A volumetric model-based 2D to 3D registration method for measuring kinematics of natural knees with single-plane fluoroscopy

Purpose: Accurate measurement of the three-dimensional (3D) rigid body and surface kinematics of the natural human knee is essential for many clinical applications. Existing techniques are limited either in their accuracy or lack more realistic experimental evaluation of the measurement errors. The purposes of the study were to develop a volumetric model-based 2D to 3D registration method, called the weighted edge-matching score (WEMS) method, for measuring natural knee kinematics with single-plane fluoroscopy to determine experimentally the measurement errors and to compare its performance with that of pattern intensity (PI) and gradient difference (GD) methods. Methods: The WEMS method gives higher priority to matching of longer edges of the digitally reconstructed radiograph and fluoroscopic images. The measurement errors of the methods were evaluated based on a human cadaveric knee at 11 flexion positions. Results: The accuracy of the WEMS method was determined experimentally to be less than 0.77 mm for the in-plane translations, 3.06 mm for out-of-plane translation, and 1.13 deg. for all rotations, which is better than that of the PI and GD methods. Conclusions: A new volumetric model-based 2D to 3D registration method has been developed for measuring 3D in vivo kinematics of natural knee joints with single-plane fluoroscopy. With the equipment used in the current study, the accuracy of the WEMS method is considered acceptable for the measurement of the 3D kinematics of the natural knee in clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Empirical State Error Covariance Matrix Orbit Determination Example

State estimation techniques serve effectively to provide mean state estimates. However, the state error covariance matrices provided as part of these techniques suffer from some degree of lack of confidence in their ability to adequately describe the uncertainty in the estimated states. A specific problem with the traditional form of state error covariance matrices is that they represent only a mapping of the assumed observation error characteristics into the state space. Any errors that arise from other sources (environment modeling, precision, etc.) are not directly represented in a traditional, theoretical state error covariance matrix. First, consider that an actual observation contains only measurement error and that an estimated observation contains all other errors, known and unknown. Then it follows that a measurement residual (the difference between expected and observed measurements) contains all errors for that measurement. Therefore, a direct and appropriate inclusion of the actual measurement residuals in the state error covariance matrix of the estimate will result in an empirical state error covariance matrix. This empirical state error covariance matrix will fully include all of the errors in the state estimate. The empirical error covariance matrix is determined from a literal reinterpretation of the equations involved in the weighted least squares estimation algorithm. It is a formally correct, empirical state error covariance matrix obtained through use of the average form of the weighted measurement residual variance performance index rather than the usual total weighted residual form. Based on its formulation, this matrix will contain the total uncertainty in the state estimate, regardless as to the source of the uncertainty and whether the source is anticipated or not. It is expected that the empirical error covariance matrix will give a better, statistical representation of the state error in poorly modeled systems or when sensor performance is suspect. In its most straight forward form, the technique only requires supplemental calculations to be added to existing batch estimation algorithms. In the current problem being studied a truth model making use of gravity with spherical, J2 and J4 terms plus a standard exponential type atmosphere with simple diurnal and random walk components is used. The ability of the empirical state error covariance matrix to account for errors is investigated under four scenarios during orbit estimation. These scenarios are: exact modeling under known measurement errors, exact modeling under corrupted measurement errors, inexact modeling under known measurement errors, and inexact modeling under corrupted measurement errors. For this problem a simple analog of a distributed space surveillance network is used. The sensors in this network make only range measurements and with simple normally distributed measurement errors. The sensors are assumed to have full horizon to horizon viewing at any azimuth. For definiteness, an orbit at the approximate altitude and inclination of the International Space Station is used for the study. The comparison analyses of the data involve only total vectors. No investigation of specific orbital elements is undertaken. The total vector analyses will look at the chisquare values of the error in the difference between the estimated state and the true modeled state using both the empirical and theoretical error covariance matrices for each of scenario.

Frisbee, Joseph H., Jr.↗

WE-FG-207B-08: Dual-Energy CT Iodine Accuracy Across Vendors and Platforms

Purpose: Although a major benefit of dual-energy CT is its quantitative capabilities, it is critical to understand how results vary by scanner manufacturer and/or model before making clinical patient management decisions. Each manufacturer utilizes a specific dual-energy CT approach; cross-calibration may be required for facilities with more than one dual-energy CT scanner type. Methods: A solid dual-energy quality control phantom (Gammex, Inc.; Appleton, WI) representing a large body cross-section containing three Iodine inserts (2mg/ml, 5mg/ml, 15 mg/ml) was scanned on these CT systems: GE HD-750 (80/140kVp), prototype GE Revolution CT with GSI (80/140kVp), Siemens Flash (80/140kVp and 100/140kVp), and Philips IQon (120kVp and 140kVp). Iodine content was measured in units of concentration (mg/ml) from a single 5mm-thick central image. Three to five acquisitions were performed on each scanner platform in order to compute standard deviation. Scan acquisitions were approximately dose-matched (∼25mGy CTDIvol) and image parameters were as consistent as possible (thickness, kernel, no noise reduction applied). Results: Iodine measurement error ranges were −0.24-0.16 mg/ml for the 2mg/ml insert (−12.0 − 8.0%), −0.28–0.26 mg/ml for the 5mg/ml insert (−5.6 − 5.2%), and −1.16−0.99 mg/ml for the 15mg/ml insert (−7.7 − 6.6%). Standard deviations ranged from 0 to 0.19 mg/ml for the repeated acquisitions from each scanner. The average iodine measurement error and standard deviation across all systems and inserts was −0.21 ± 0.48 mg/ml (−1.5 ± 6.48%). The largest absolute measurement error was found in the 15mg/ml iodine insert. Conclusion: There was generally good agreement in Iodine quantification across 3 dual-energy CT manufacturers and 4 scanner models. This was unexpected given the widely different underlying dual-energy CT mechanisms employed. Future work will include additional scanner platforms, independent verification of the Iodine insert standard concentrations (especially the 15 mg/ml insert), and how much measurement variability can be clinically tolerated. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

Measurement of precision oscillator phase noise using the two-oscillator coherent down-conversion technique

The characterization of precision frequency standard phase noise and spurious outputs is addressed, using the two-oscillator coherent downconversion technique. Focus is on techniques for making accurate measurements of phase noise and spurious outputs within 100 KHz of a carrier. Significant sources of measurement error related to hardware design problems and inadequate measurement procedures are discussed: measurement errors resulting from system noise sources, phase-locked loop effects, and system bandwidth limitations. In addition, methods and design considerations for minimizing the effects of such errors are presented. Analytic discussions and results are supplemented with actual test data and measurements made using measurement hardware developed at the Ball Corporation, Efratom Division.

Christopher J. Pagnanelli↗

Effects of error covariance structure on estimation of model averaging weights and predictive performance

When conducting model averaging for assessing groundwater conceptual model uncertainty, the averaging weights are often evaluated using model selection criteria such as AIC, AICc, BIC, and KIC (Akaike Information Criterion, Corrected Akaike Information Criterion, Bayesian Information Criterion, and Kashyap Information Criterion, respectively). However, this method often leads to an unrealistic situation in which the best model receives overwhelmingly large averaging weight (close to 100%), which cannot be justified by available data and knowledge. It was found in this study that this problem was caused by using the covariance matrix, CE, of measurement errors for estimating the negative log likelihood function common to all the model selection criteria. This problem can be resolved by using the covariance matrix, Cek, of total errors (including model errors and measurement errors) to account for the correlation between the total errors. An iterative two-stage method was developed in the context of maximum likelihood inverse modeling to iteratively infer the unknown Cek from the residuals during model calibration. The inferred Cek was then used in the evaluation of model selection criteria and model averaging weights. While this method was limited to serial data using time series techniques in this study, it can be extended to spatial data using geostatistical techniques. The method was first evaluated in a synthetic study and then applied to an experimental study, in which alternative surface complexation models were developed to simulate column experiments of uranium reactive transport. It was found that the total errors of the alternative models were temporally correlated due to the model errors. The iterative two-stage method using Cek resolved the problem that the best model receives 100% model averaging weight, and the resulting model averaging weights were supported by the calibration results and physical understanding of the alternative models. Using Cek obtained from the iterative two-stage method also improved predictive performance of the individual models and model averaging in both synthetic and experimental studies.

error correlation↗

Development of an optical three-dimensional laser tracker using dual modulated laser diodes and a signal detector

Laser trackers are widely used in industry for tasks such as the assembly of airplanes and automobiles, contour measurement, and robot calibration. However, laser trackers are expensive, and the corresponding solution procedure is very complex. The influence of measurement uncertainties is also significant. This study proposes a three-dimensional space position measurement system which consists of two tracking modules, a zero tracking angle return subsystem, and a target quadrant photodiode (QPD). The target QPD is placed on the object being tracked. The origin locking method is used to keep the rays on the origin of the target QPD. The position of the target QPD is determined using triangulation since the two laser rays are projected onto one QPD. Modulation and demodulation are utilized to separate the coupled positional values. The experiment results show that measurement errors in the X, Y, and Z directions are less than {+-}0.05% when the measured object was moved by 300, 300, and 200 mm in the X, Y, and Z axes, respectively. The theoretical measurement error estimated from the measurement model is between {+-}0.02% and {+-}0.07% within the defined measurable range. The proposed system can be applied to the measurements of machine tools and robot arms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fully redundant double difference algorithm for obtaining minimum variance estimates from GPS observations

In double differencing a regression system obtained from concurrent Global Positioning System (GPS) observation sequences, one either undersamples the system to avoid introducing colored measurement statistics, or one fully samples the system incurring the resulting non-diagonal covariance matrix for the differenced measurement errors. A suboptimal estimation result will be obtained in the undersampling case and will also be obtained in the fully sampled case unless the color noise statistics are taken into account. The latter approach requires a least squares weighting matrix derived from inversion of a non-diagonal covariance matrix for the differenced measurement errors instead of inversion of the customary diagonal one associated with white noise processes. Presented is the so-called fully redundant double differencing algorithm for generating a weighted double differenced regression system that yields equivalent estimation results, but features for certain cases a diagonal weighting matrix even though the differenced measurement error statistics are highly colored.

Melbourne, William G.↗

An Evaluation of Redd Counts as a Measure of Bull Trout Population Size and Trend

Abstract The use of redd counts to monitor abundance and trend of bull trout Salvelinus confluentus has been clouded by uncertainties concerning measurement error, life history variation, and correspondence of redd counts to adult population size. We compared census redd counts with population estimates of mature females for a migratory fluvial population of bull trout (primarily ≥ 300 mm fork length) and for a population of small (<200 mm), likely resident, bull trout. We also compared the measurement error of the experienced surveyors who conducted the redd counts to that of a group of inexperienced surveyors. Although the regression of redd counts on adult females for the migratory population was statistically significant, a large proportion of the variation in the relationship was unexplained (r 2 = 0.47). Despite that variation, redd counts accurately reflected a greater than 50% decline in the population over 10 years; however, 5-year trends in redd counts could be misleading. Power analysis parameterized by using the variation in the number of females per redd and measurement error of experienced surveyors indicated that minimum declines of 44–56% or increases of 78–118% over 10–15 years would be necessary for detection using traditional statistical criteria. Geometric mean abundance of migratory adults derived from redd counts and adults-per-redd values from the present study and published averages were similar to measured adult numbers in most cases. For both migratory and resident populations, redd counts by experienced surveyors were substantially more accurate and precise than those by inexperienced surveyors. Counts of migratory bull trout redds were more accurate and precise than counts of resident bull trout redds, which were significantly smaller and consistently underestimated. Thus, bull trout redd counts can be used to estimate abundance levels and to detect substantial longer-term changes in abundance, particularly for migratory populations. However, the reliability of the counts depends on the skill of the surveyors. Received April 4, 2011; accepted August 8, 2011

Howell, Philip J.↗

A Regional CO2 Observing System Simulation Experiment for the ASCENDS Satellite Mission

Top-down estimates of the spatiotemporal variations in emissions and uptake of CO2 will benefit from the increasing measurement density brought by recent and future additions to the suite of in situ and remote CO2 measurement platforms. In particular, the planned NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) satellite mission will provide greater coverage in cloudy regions, at high latitudes, and at night than passive satellite systems, as well as high precision and accuracy. In a novel approach to quantifying the ability of satellite column measurements to constrain CO2 fluxes, we use a portable library of footprints (surface influence functions) generated by the WRF-STILT Lagrangian transport model in a regional Bayesian synthesis inversion. The regional Lagrangian framework is well suited to make use of ASCENDS observations to constrain fluxes at high resolution, in this case at 1 degree latitude x 1 degree longitude and weekly for North America. We consider random measurement errors only, modeled as a function of mission and instrument design specifications along with realistic atmospheric and surface conditions. We find that the ASCENDS observations could potentially reduce flux uncertainties substantially at biome and finer scales. At the 1 degree x 1 degree, weekly scale, the largest uncertainty reductions, on the order of 50 percent, occur where and when there is good coverage by observations with low measurement errors and the a priori uncertainties are large. Uncertainty reductions are smaller for a 1.57 micron candidate wavelength than for a 2.05 micron wavelength, and are smaller for the higher of the two measurement error levels that we consider (1.0 ppm vs. 0.5 ppm clear-sky error at Railroad Valley, Nevada). Uncertainty reductions at the annual, biome scale range from 40 percent to 75 percent across our four instrument design cases, and from 65 percent to 85 percent for the continent as a whole. Our uncertainty reductions at various scales are substantially smaller than those from a global ASCENDS inversion on a coarser grid, demonstrating how quantitative results can depend on inversion methodology. The a posteriori flux uncertainties we obtain, ranging from 0.01 to 0.06 Pg C yr-1 across the biomes, would meet requirements for improved understanding of long-term carbon sinks suggested by a previous study.

remote sensing↗

Digitally modulated bit error rate measurement system for microwave component evaluation

The NASA Lewis Research Center has developed a unique capability for evaluation of the microwave components of a digital communication system. This digitally modulated bit-error-rate (BER) measurement system (DMBERMS) features a continuous data digital BER test set, a data processor, a serial minimum shift keying (SMSK) modem, noise generation, and computer automation. Application of the DMBERMS has provided useful information for the evaluation of existing microwave components and of design goals for future components. The design and applications of this system for digitally modulated BER measurements are discussed.

Shalkhauser, Mary Jo W.↗