Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “matrix isolation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

164 records · Page 10

AGR-5/6/7 Final Release-to-Birth Ratio Data Analysis

AGR-5/6/7 is the last of a series of Advanced Gas Reactor (AGR) experiments conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) in support of development and qualification of tristructural isotropic (TRISO) low-enriched fuel for use in the high-temperature gas cooled reactor (HTGR). AGR configuration and irradiation conditions are based on prismatic HTGR technology that is distinguished primarily through the use of helium coolant, a low-power-density ceramic core capable of withstanding very high temperatures, and TRISO-coated particle fuel. The AGR tests provide valuable irradiation-performance data to support fuel process development, qualify fuel for normal operation and accident conditions, and support development and validation of fuel performance and fission-product (FP) transport models and codes. Each AGR test consists of multiple independently controlled and monitored capsules containing fuel compacts placed in a graphite cylinder shrouded by a steel shell. Release-to-birth ratios (R/B) for fission-gas isotopes released from each capsule are calculated from release rates, measured by germanium detectors in the Fission Product Monitoring System (FPMS) installed downstream from each capsule, and birth rates calculated using numerical models of FG generation. The R/Bs are a critical measure of the ability of the fuel kernel, the particle coating layers, and the compact matrix to retain fission-gas atoms, preventing their release into the sweep-gas flow, and the impact of initially defective particles and/or particle-coating failures that occur during irradiation. For fission-gas isotopes, particle failure is defined as failure of all coating layers, allowing gaseous fission atoms to escape from a particle. During the first five cycles (162B ? 165A), R/Bs were stable in the 10-8?10-6 range, and no in-pile particle failures were observed, based on the gross gamma counts. The maximum R/B value of around 2 ? 10-6 for Kr-85m resulted from the presence of as-fabricated exposed kernels (based on the high exposed kernel fraction), the dispersed uranium, and high fuel particle temperatures in Capsule 1. Comparison of capsule-measured R/Bs from these early cycles to predictions using the previously developed AGR R/B model demonstrated FG release from the AGR-5/6/7 TRISO fuel was comparable to that of previous experiments. In addition, the Kr-85m R/B per-exposed-kernel values are comparable to R/B values obtained in AGR-3/4 irradiation experiment and four irradiation experiments performed during 1980s: (1) HRB-17/18, (2) COMEDIE-BD1, (3) HFR B1, and (4) HRB-21. In contrast, all measured R/B values are lower than predictions by the commonly used Richards and German models, which are intentionally conservative. A large number of in-pile particle failures occurred in Capsule 1 by the end of Cycle 166A. During the final four cycles (166A ? 168A), apparent damage to the Capsule 1 gas line appeared to cause FG leakage from that capsule into the other four capsules, resulting in an increase in fission gas (FG) detected in the effluent for all capsules. Isolation of the Capsule 1 gas line during the last three cycles also prevented measurement of its FG release. Thus, R/Bs in all capsules after Cycle 166A are highly uncertain because of undefined amount of leakage from Capsule 1, especially for long-lived isotopes. A few hundred in-pile particle failures were estimated for Capsule 1 before the end of Cycle 166A, but the total number of failures is unknown due to the lack of FG release data in the later cycles. Based primarily on evidence from the gross gamma counts during Cycle 168A, approximately 15 particles failed in Capsule 3 and four particles failed in Capsule 2. In-pile failures in Capsule 3 were anticipated because this capsule was designed to operate beyond the HTGR normal operating temperature range. In contrast, no in-pile failures were identified in the top two capsules (4 and 5) based on the absence of the typical spikes in gross gamma counts and low failure estimates using the AGR model, developed in INL/EXT-14-32970, for R/B of the short-lived isotopes (Kr-89 and Xe-137) with minimal leakage from Capsule 1.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New Modulation and Impact of Transformer Leakage Inductance on Current-Source Solid-State Transformer

This article presents a novel modulation scheme for device voltage stress mitigation and comprehensive analysis of the impact of transformer leakage inductance in a current-source solid-state transformer (SST). Different from dual active bridge (DAB) SST, the operation of the current-source SST is similar to that of a flyback converter. The device bridge on only one side of the transformer is active to store energy into or release energy from the magnetizing inductance which acts as a current-source dc link. Such flyback operation with reverse-blocking switches can lead to additional device voltage stress and incomplete zero-voltage switching (ZVS) on the current-source soft-switching solid-state transformer (S4T) under conventional modulation. A new modulation scheme is proposed to address this issue. Moreover, different from the DAB, the leakage inductance of the medium-frequency transformer (MFT) in the S4T is a parasitic element similar to that in a matrix SST and can cause additional device voltage stress. Though the resonant capacitors, originally added to achieve ZVS, can absorb and recycle the leakage energy in the S4T, these capacitors need to be increased with larger leakage inductances to limit the voltage stress. However, large resonant capacitors can result in more lost duty cycles and reduced efficiency. The impact of such leakage inductance on device voltage stress is analyzed comprehensively, which is critical to guide future research and design of the S4T. Experimental results from S4T prototypes for DC-DC, multiport AC-DC, and AC-AC conversion with 1:1 and 4:1 MFT comprehensively verify the proposed concepts. Lastly, a case study of a three-phase AC-AC S4T over a power range from 1 kVA to 100 kVA each module reveals that the MFT leakage inductance should be less than 1% of the magnetizing inductance for safe operation.

14 SOLAR ENERGY↗