Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “materials evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Guarded Hot Cylinder Apparatus for Characterization of Thermal Insulation Systems and Materials at Liquid Hydrogen Temperatures

As interest in liquid hydrogen (LH2) continues to grow within the energy and mobility sectors, so does the demand for testing capabilities at deep cryogenics temperatures. However, cost-, complexity-, and safety-related challenges associated with handling LH2 effectively limit the landscape of possible options. As an alternative, LH2 temperatures can be accessed via a helium-based cryogenic refrigerator, or “cryocooler”. Recently, NASA and its partners CB&I and Shell began the development of a cryocooler-based calorimeter to characterize the thermal performance of insulations and other materials down to 20 K. Deemed the Guarded Hot Cylinder (GHC), the apparatus utilizes a small vacuum chamber in conjunction with a GM cryocooler and trim heater to control the cold boundary temperature. A sealed, cylindrical copper cup bolts to the cryocooler and houses the material specimen, with an internal, cylindrical test heater assembly to maintain the warm boundary. The steady-state heat load, traveling radially through the specimen, is measured via the electrical input power to the test heater and then used to evaluate the material’s absolute thermal performance. Initial checkout and validation of the GHC using a common bulk-fill insulation material showed close agreement with published data from standardized LN2 boiloff calorimetry testing. The instrument is now considered a lab standard, with the goal of incorporating it into the ASTM C1774 standard in the future, and it is in continuous use, examining insulation materials for next-generation LH2 applications.

Swanger, Adam (ORCID:000000021487592X)↗

Techno-Economic Optimization of Advanced Energy Plants with Integrated Thermal, Mechanical, and Electro-Chemical Storage (Final Report)

The increasing use of renewable energy sources is leading to increased cycling of fossil-fueled power plants (FFPP) that are designed to operate at base-loaded conditions. Integrating energy storage facilities with the FFPPs can be helpful in reducing load-following operation of FFPPs. Decentralized deployment of energy storage facilities at the FFPP level has considerable advantages due to possibilities of smaller storage capacities, immediate benefits realized by the host power plant due to the increase in the efficiency, cleaner emission and higher plant life to name a few. Most importantly, deployment at the FFPP level can exploit the existing equipment items and facilities at the host power plant, thus reducing the CAPEX and reducing the storage capacity. However, realization of these benefits will critically depend on novel configuration/integration strategies with the least impact on the power plant operation and its configuration. Furthermore, dynamics of the entire integrated system including both the FFPP and the storage technologies must be taken into account to obtain the cost-optimal solution. With these motivations, the objective of this project was to complete a focused evaluation of decentralized deployments of energy storage facilities at the FFPP level. Promising thermal, chemical, mechanical, and electro-chemical storage technologies were evaluated with due consideration of their transient response to obtain various optimal system concepts that can minimize the levelized cost of storage. For thermal storage, cryogenic energy storage along with high temperature heat storage in molten salt as well as phase change material were evaluated. For mechanical storage, cryogenic air storage and pumped hydro storages were evaluated. For chemical storage, hydrogen storage was evaluated. For electrochemical storage, the team evaluated sodium sulfur, vanadium redox flow battery as well as Li-ion batteries. Integration of these storage technologies with the natural gas combined cycle (NGCC) and supercritical pulverized coal (SCPC) plants was considered. Six technologies, namely molten salt, cryogenics, compressed air, pumped hydro, H2 storage and Li-ion battery storage, were downselected based on their levelized cost of storage. It was observed that the ranking of the optimal storage technology can differ based on the host power plant technology even when same demand/supply/price profile for electricity are considered. It was also observed that as the variability in power demand varies, the ranking of the optimal storage technologies vary. However, for the same demand and LMP profile, top six optimal storage technologies for NGCC vs SCPC plants did not differ much even though LCOS for the same technology and optimal size of a given storage technology did differ. Detailed techno-economic assessment of these six technologies was undertaken.

01 COAL, LIGNITE, AND PEAT↗

Decarbonizing Cooking Appliances With Hydrogen

A novel hydrogen compatible heterogeneous burner prototype was engineered, fabricated, and evaluated for applications in cooking appliances. The key features targeted and accomplished under this effort included fuel flexibility, tolerance to high hydrogen concentrations (up to 85% in atmospheric design and 100% in premixed design), wide range of thermal power ratings, thermal cycling, reliability, and most importantly safety. The burner was operated in the range of 3000 – 12,000 Btu/h under all practical operating conditions (cold start, hot restart, fuel concentration variance). The heterogeneous oxidation burner technology was evaluated for overall performance targeting safety, reliability, emissions, fuel flexibility, and energy efficiency in a commercial RV and residential cooking range appliance prototypes. The burner demonstrated safe and reliable performance generating infrared heating energy without the consumption of any parasitic energy while using low-cost materials. Performance evaluation testing of the novel IR burner demonstrated fuel flexibility with hydrogen blended natural gas while significantly eliminating air pollutants like NOx and methane and increasing the energy efficiency by up to 20%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of fracture in porous materials: a phase-field fracture study informed by ReaxFF

Microscopic features (e.g, pore shapes, sizes, and distribution) in porous material substantially affect the overall mechanical properties such as stiffness and strength. In turn, these material properties determine the macroscopic behaviors of fracture in the porous material. In certain cases, macroscopic properties can be derived from the porous skeleton and void ratio (i.e., porosity), but in many other cases, such derivation is a challenging task. This paper presents a numerical investigation of microporosity and micropore shapes effect on the macrofracture behavior in porous amorphous silica. For this study, we extend the recently-proposed combined molecular dynamic (MD) and phase-field (PF) fracture modeling approach by including different pore shapes in the atomistic domain. In the MD simulations, we adopt ReaxFF to evaluate the material properties, where four different micropore cases are considered. Based on the material properties derived from MD simulations, the macrofracture propagation of porous media is studied using hybrid PF simulation. In the characterization of the pore structure, the concept of pore ligament is proposed to relate the pore shape and the critical energy release rate. Two classical fracture problems were used to evaluate the effect of pore shape on the macrofracture behavior. The results of the case study show that although the micropore shapes change the macrofracture behaviors, these effects vary with the geometry and loading conditions of macroscopic boundary value problems. Furthermore, the case study also shows that the influence of micropore structure can be captured at the macroscopic level through the material properties derived from the MD simulations.

42 ENGINEERING↗

Origin of Disorder Tolerance in Piezoelectric Materials and Design of Polar Systems

Current high-performing piezoelectric materials are dominated by perovskites that rely on soft optical phonon modes stabilized by disorder near a morphotropic phase boundary and a unique resilience of the polar response to that disorder. To identify structural families with similar resilience, in this study we develop a first-principles sensitivity analysis approach to determine the effect of disorder on the piezoelectric response for structures in the Materials Project database. In well-known piezoelectric systems, the lattice dynamics, rather than internal strain or dielectric, control the polar response. Additionally, multiple stable optical phonon modes are found to contribute to the piezoelectric response, providing a fingerprint for disorder tolerance. A multiple-phonon mode criterion is used to evaluate candidate materials for disorder-tolerant piezoelectric prototype systems. Five promising structures are altered through chemical substitution, generating potential MPB end points with large piezoelectric responses beyond perovskites including Akermanite Sr 2 x Ca 2 – 2 x CoSi 2 O 7 , which exhibits a nearly 20% increase in response at the 50% composition.

36 MATERIALS SCIENCE↗

Tuning acidity in silica-overcoated oxides for hydroalkoxylation

Mixed oxides are ubiquitious solid acid catalysts for a number of transformations. Here, the chemistry of mixed oxide interfaces was experimentally probed by constructing model SiO 2 on MO x interfaces using a liquid-phase, stoichiometrically-controlled deposition of tetraethyl orthosilicate (TEOS). Catalytically active Brønsted sites were generated in four series of overcoated SiO 2 on metal oxide materials prepared by depositing TEOS onto Al 2 O 3 , anatase TiO 2 , Nb 2 O 5 , and ZrO 2 . Pyridine DRIFTS studies indicate that the acidity of deposited silanol groups was enhanced by interaction with the metal oxide surface, suggesting that pseudo-bridging silanol type structures were formed. Trimethylphosphine oxide (TMPO) 31 P NMR experiments showed that Brønsted acid strength varied in the overcoated materials, with increasing strength in the following order: SiO 2 /ZrO 2 < SiO 2 /TiO 2 < SiO 2 /Nb 2 O 5 < SiO 2 /Al 2 O 3 . This order correlated with the Lewis acidity and chemical hardness of the underlying metal oxides. The catalytic performance of the materials was evaluated in the liquid-phase hydroalkoxylation of dihydropyran with n-octanol, revealing that activity was highly dependent on SiO 2 loading, which impacted the density of acid sites, and scaled exponentially with Brønsted acid strength, determined by the core metal oxide identity. Brønsted acid strength appears to be the key driver of the materials’ activity, with the highest areal rate of 2.2 mmol / m 2 – h being measured over SiO 2 /Al 2 O 3 . Furthermore, this study shows that SiO 2 -overcoated materials are a systematically tunable class of catalysts that can be applied to acid catalyzed reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solution processed high aspect ratio ultra-long vertically well-aligned ZnO nano scintillators for potential X-ray imaging applications

We report the photon (PL), electron (CL) and X-ray (XEL) induced luminescence characteristics of high aspect ratio ultra-long (~ 50 µm) ZnO nanorods (NRs) and discuss the potential for fast X-ray detection based on the consistent and efficient visible emission (~ 580 nm) from ZnO NRs. Nanostructured ZnO scintillators were rearranged to form a vertically well-aligned NR design in order to help light absorption and coupling resulting in luminescent and fast scintillation properties. The design of the nanorod array combines the key advantages of a low-cost growth technique together with environmentally friendly and widely available materials. A low temperature hydrothermal method was adopted to grow ZnO NRs in one cycle growth and their structural, optical and X-ray scintillation properties were investigated. The relatively short (~ 10 µm) ZnO NRs emitting in the near-band-edge region were found to be almost insensitive to X-rays. On the other hand, the higher XEL response of long ZnO NRs, which is a key parameter for evaluation of materials to be used as scintillators for high quality X-ray detection and imaging, along with a decay time response in the order of ns confirmed promising scintillation properties for fast and high-resolution X-ray detector applications.

47 OTHER INSTRUMENTATION↗

Redox Defect Thermochemistry of FeAl 2 O 4 Hercynite in Water Splitting from First-Principles Methods

Solar thermochemical hydrogen (STCH) production is a promising route to produce fuels from sunlight via high-temperature water splitting. However, efficient and technologically viable implementations of this process only allow a narrow window of thermodynamic boundary conditions that can be used to cycle the system, thus limiting the design space for suitable metal oxide redox mediators. An oxygen defect redox mechanism can contribute a favorable reduction entropy to expand this window, and computational evaluation of materials with high oxygen defect entropies could play a pivotal role in guiding the discovery and design of suitable oxides. This study employs first-principles calculations to investigate the redox mediating defect mechanism of the STCH candidate material, hercynite (FeAl 2 O 4 ). We compare the results of total energy calculations from density functional theory (DFT) with beyond-DFT approaches, including hybrid functionals and the random phase approximation, which are among the most advanced methods currently feasible for supercell defect calculations. Using the predicted formation energies, we perform thermodynamic modeling of FeAl2O4 reduction and oxidation via free energy minimization that incorporates ideal gas, configurational, and vibrational entropy contributions evaluated within the quasi-harmonic approximation. Special attention is devoted to understanding interactions among co-existing defects, such as the association of pairs and complexes of O vacancies and cation antisite defects, and the effect of mutually compensating defect charges. Our results corroborate the notion that the details of defect interactions can be decisive for the viability of hydrogen production within the desirable STCH process window.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Retractable Sensors for In-Core Use in Material Test Reactors - conf paper

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on friction drive wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 – 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 – 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology’s MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigation of the crush performance of prepreg platelet molding compound tubes

This work presents an experimental study characterizing the crush performance of hollow cylindrical tubes made with prepreg platelet molding compound (PPMC). PPMC is a composite material system that uses platelets from chopped and slit unidirectional prepreg as the basis for a molding compound. This material system has a higher fiber volume fraction and better mechanical properties than traditional short fiber systems and can be molded into complex geometries unlike continuous fiber systems. As such, this material system shows promise for use with complex structural members in vehicles. The failure morphology and specific energy absorption of the material are evaluated with different thickness-to-diameter geometries and test speeds. In addition, this work investigates how PPMC components compare to traditional continuous fiber components and finds that PPMC performs as well as continuous fiber layups with similar effective laminate stiffnesses.

Materials Science↗

Deployment of the HFIRCON transport and depletion tool for plutonium-238 production studies

Irradiation of {sup 237}Np-bearing targets in Oak Ridge National Laboratory's (ORNL) High Flux Isotope Reactor (HFIR) results in the efficient production of {sup 238}Pu, which, in the form of heat source PuO{sub 2}, is used as a reliable power source for deep-space and planetary NASA missions. A technology demonstration subproject was initiated at ORNL in 2011 to develop and implement the technology required to establish a {sup 238}Pu supply chain. A systematic progression of NpO{sub 2}/Al cermet (20 vol.% NpO{sub 2}) activities to date has successfully demonstrated target fabrication, irradiation, and chemical recovery processes. Recent program tasks have included the development of the HFIRCON transport and depletion tool for efficient reactor physics analyses and the evaluation of increased NpO{sub 2} loadings (i.e., beyond 20 vol.%) and NpN-based targets. This paper documents the deployment of the HFIRCON code to assess various Np concentrations in NpO{sub 2}- and NpN-based targets in HFIR's inner small vertical experiment facilities. Results indicate that {sup 238}Pu production and quality can be enhanced with increased Np loadings; however, target conversion rates are reduced. The results recorded in this paper, thermal and material balance evaluations, and testing requirement planning will be used to determine whether increased NpO{sub 2} loadings or NpN-based targets will be further considered. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Direct and Sensitive Electrochemical Evaluation of Pramipexole Using Graphitic Carbon Nitride (gCN) Sensor

Pramipexole (PMXL) belongs to the benzothiazole class of aromatic compounds and is used in treating Parkinson’s disease; however, overdosage leads to some abnormal effects that could trigger severe side effects. Therefore, it demands a sensitive analytical tool for trace level detection. In this work, we successfully developed an electrochemical sensor for the trace level detection of PMXL, using the voltammetric method. For the analysis, graphitic carbon nitride (gCN) was opted and synthesized by using a high-temperature thermal condensation method. The synthesized nanoparticles were employed for surface characterization, using transmission electron microscopy (TEM), X-ray diffraction (XRD), and atomic force microscopy (AFM) techniques. The electrochemical characterization of the material was evaluated by using the electrochemical impedance spectroscopy (EIS) technique to evaluate the solution–electrode interface property. The cyclic voltammetry (CV) behavior of PMXL displayed an anodic peak in the forward scan, indicating that PMXL underwent electrooxidation, and an enhanced detection peak with lower detection potential was achieved for gCN-modified carbon paste electrode (gCN·CPE). The influence of different parameters on the electrochemical behavior was analyzed, revealing the diffusion governing the electrode process with an equal number of hydronium ions and electron involvement. For the fabricated gCN·CPE, good linearity range was noticed from 0.05 to 500 µM, and a lower detection limit (L D ) of 0.012 µM was achieved for the selected concentration range (0.5 to 30 µM). Selectivity of the electrode in PMXL detection was investigated by conducting an interference study, while the tablet sample analysis demonstrates the sensitive and real-time application of the electrode. The good recovery values for the analysis illustrate the efficiency of the electrode for PMXL analysis.

36 MATERIALS SCIENCE↗

Distributed Magnetic Field and Temperature Monitoring for Superconducting Radio Frequency Cavities

The overall objective of the proposed Phase I program was to design, construct and demonstrate a fiber optic sensing system capable of providing temperature and magnetic field measurements with an enhanced spatial resolution that can be implemented over a large surface area (cryomodules) to survey superconducting radio frequency cavities and magnets. A magnetic field sensor capable of detecting fluxes on the order of 1 μT is required to detect the distribution of trapped flux on the cavity surface. A unique distributed magnetic field sensor was successfully designed and constructed to demonstrate the detection of magnetic fluxes less than 500 nT. The sensor leveraged the ultra-high sensitivity of Sentek’s picoDAS to measure the magnetostriction induced vibrations in a commercially available Metglas 2605 SC ribbon that was in physical contact with sensing fiber. Static magnetic fields were detected by applying an alternating current a copper wire proximate to the Metglas 2605SC ribbon to create an AC bias magnetic field. In an alternative approach, an AC bias magnetic field was applied to a special magnetic field sensing fiber with Metglas 2605SC cladding successfully detect a magnetic field flux of a 3 μT. Exhaustive testing was performed to characterize the dependency of sensor response on the direction of the applied magnetic field. Although the special sensing fiber based magnetic field sensor did not exhibit an observable dependence on the direction of the magnetic field, the Metglas 2605SC ribbon sensor exhibited a clear directional dependence. A wide variety of polymer materials were evaluated to enhance the temperature response of an FBG based sensor at cryogenic temperatures. The processing and performance challenges provided the motivation to develop a new simple cryogenic temperature sensor that uses a commercially available fiber optic splice protector. The EVA hot melt tube that becomes adhered to the optical fiber and the polyolefin outer tube that shrinks upon heating in the fusion splicer heater provide the high thermal expansion coefficient necessary to impart a significant strain on the FBG when exposed to cryogenic temperatures. The temperature sensitivity (Δ𝜆𝐵𝑟𝑎𝑔𝑔~ 62 𝑝𝑝𝑚/℃) of the FBG-based sensor was on par with the best reported to date. The simple design, use of readily available cost-effective materials, and well-established processing techniques lends this approach to the creation of hundreds to thousands of temperature sensors on one single optical fiber length. The inherently small form factor also allows for co-location with the distributed magnetic field sensor. In preparation for field testing of the prototype sensing system at the Jefferson Labs in potential Phase II program, several different cable designs were evaluated to package the sensors. The preliminary successful demonstration of fully functional sensing cables provides the foundation for subsequent development efforts to advance the Technology Readiness Level of the technology. The technical feasibility of the proposed approach was successfully demonstrated in this Phase I effort.

43 PARTICLE ACCELERATORS↗

Hot-melt extrudability of amorphous solid dispersions of flubendazole-copovidone: An exploratory study of the effect of drug loading and the balance of adjuvants on extrudability and dissolution

The FDA-approved anthelmintic flubendazole has shown potential to be repositioned to treat cancer and dry macular degeneration; however, its poor water solubility limits its use. Amorphous solid dispersions may overcome this challenge, but the balance of excipients may impact the preparation method and drug release. Here, we evaluate the influence of adjuvants and drug loading on the development of an amorphous solid dispersion of flubendazole-copovidone by hot-melt extrusion. The drug, copovidone, and adjuvants (magnesium stearate and hydroxypropyl cellulose) mixtures were statistically designed, and the process was performed in a twin-screw extruder. The study showed that flubendazole and copovidone mixtures were highly extrudable, except when drug loading was high (>40%). Furthermore, magnesium stearate positively impacted the extrusion and was more effective than hydroxypropyl cellulose. The extruded materials were evaluated by modulated differential scanning calorimetry and X-ray powder diffraction, obtaining positive amorphization and physical stability results. Pair distribution function analysis indicated the presence of drug rich domains with medium-range order structure and no evidence of polymer-drug interaction. All extrudates presented faster dissolution (HCl, pH 1.2) than pure flubendazole, and both adjuvants had a notable influence on the dissolution rate. In conclusion, hot-melt extrusion may be a viable option to obtain stable flubendazole: copovidone amorphous dispersions.

60 APPLIED LIFE SCIENCES↗

Characterization of CNC Nanoparticles Prepared via Ultrasonic-Assisted Spray Drying and Their Application in Composite Films

The ultrasonic-assisted spray dryer, also known as a nano spray dryer and predominantly used on a lab scale in the pharmaceutical and food industries, enables the production of nanometer-sized particles. In this study, the nano spray dryer was applied to cellulosic materials, such as cellulose nanofibrils (CNFs) and cellulose nanocrystals (CNCs). CNC suspensions were successfully dried, while the CNF suspensions could not be dried, attributable to their longer fibril lengths. The nano spray drying process was performed under different drying conditions, including nebulizer hole sizes, solid concentrations, and gas flow rates. It was confirmed that the individual particle size of nano spray-dried CNCs (nano SDCNCs) decreased as the nebulizer hole sizes and solid contents of the suspensions decreased. The production rate of the nano spray dryer increased with higher solid contents and lower gas flow rates. The resulting nano SDCNCs were added to a polyvinyl alcohol (PVA) matrix as a reinforcing material to evaluate their reinforcement behavior in a plastic matrix using solvent casting. After incorporating the 20 wt.% nano SDCNCs into the PVA matrix, the tensile strength and tensile modulus elasticity of the neat PVA nanocomposite film increased by 22% and 32%, respectively, while preserving the transparency of the films.

36 MATERIALS SCIENCE↗