Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Distinct Mechanism of Anti-Corrosion and Swelling-Adhesion Modeling of Low-Dimensional Nylon-Fluoropolymer Composite Coatings

Compared to other polymers, composite coatings with fluoropolymers as the matrix have attracted considerable interest due to their mechanical performance, chemical stability, and low surface energy. Herein, we present an anticorrosion mechanism of fluoropolymer composite coatings achieved by dispersing varying amounts of polyamide 12 (PA-12) particles over a poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) matrix. The choice of PVDF-HFP as a coating matrix was driven by its superior processability and mechanical properties over Teflon, while PA-12 afforded swelling capacity, preventing electrolyte permeation, and inhibiting matrix stress crack propagation. The corrosion resistance of the coatings was assessed mainly by potentiodynamic polarization and impedance measurements while being immersed in a NaCl solution. Our electrochemical measurement findings showed that 0.75% w/w PA-12 in the PVDF-HFP matrix significantly enhanced corrosion protection even after 21 days of immersion. Microscopy, dielectric spectroscopy, surface analysis, and mechanical testing (American Society for Testing and Materials standards) corroborated the results. PVDF-HFP coatings containing a minimum percolation threshold of 0.75 wt % PA-12 with 1 mil thickness on mild steel exhibited a remarkable increase in resistance and film adhesion, and a notable corrosion rate decrease. Finite element analysis simulation with a bilinear traction-separation law confirmed the swelling mechanism and adhesion behavior. Finally, this study highlights the potential of nylon particle dispersion in PVDF-HFP matrices as a practical approach to developing advanced anticorrosion coatings with promising practical applications in various industries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quasiparticle Level Alignment for Photocatalytic Interfaces

Electronic level alignment at the interface between an adsorbed molecular layer and a semiconducting substrate determines the activity and efficiency of many photocatalytic materials. Standard density functional theory (DFT)-based methods have proven unable to provide a quantitative description of this level alignment. This requires a proper treatment of the anisotropic screening, necessitating the use of quasiparticle (QP) techniques. However, the computational complexity of QP algorithms has meant a quantitative description of interfacial levels has remained elusive. We provide a systematic study of a prototypical interface, bare and methanol-covered rutile TiO2(110) surfaces, to determine the type of many-body theory required to obtain an accurate description of the level alignment. This is accomplished via a direct comparison with metastable impact electron spectroscopy (MIES), ultraviolet photoelectron spectroscopy (UPS), and two-photon photoemission (2PP) spectroscopy. We consider GGA DFT, hybrid DFT, and G0W0, scQPGW1, scQPGW0, and scQPGW QP calculations. Our results demonstrate that G0W0, or our recently introduced scQPGW1 approach, are required to obtain the correct alignment of both the highest occupied and lowest unoccupied interfacial molecular levels (HOMO/LUMO). These calculations set a new standard in the interpretation of electronic structure probe experiments of complex organic molecule/semiconductor interfaces.

Environmental Molecular Sciences Laboratory↗

Analysis of Metal Site Preference and Electronic Structure of Brownmillerite-Phase Oxides (A[subscript 2]B'[subscript x]B[subscript 2-x]O[subscript 5]; A=Ca, Sr; B'/B=Al, Mn, Fe, Co) by X-ray Absorption Near-Edge Spectroscopy

X-ray absorption near-edge spectroscopic (XANES) measurements of the Fe and Co K-edges for a series of Brownmillerite-type transition-metal oxides (A{sub 2}B{prime}{sub x}B{sub 2-x}O{sub 5}; A = Ca, Sr; B{prime}/B = Al, Mn, Fe, Co) have been made. In these compounds, the metal atoms are present in both octahedral and tetrahedral coordination environments. The spectra were interpreted with the aid of electronic structure calculations. Significant changes in intensity and energy were observed in the Fe K-edge spectra as the average Fe{sup 3+} coordination number (CN) was changed from 5.5 (Ca{sub 2}AlFeO{sub 5}) to 4.2 (Ca{sub 2}FeMnO{sub 5}). In Ca{sub 2}Co{sub x}Fe{sub 2-x}O{sub 5}, the Fe K- and Co K-edge XANES spectra indicated that Fe has a slight octahedral site preference in these series. This confirmed that size effects play a significant role in controlling the site preference of metal atoms in these compounds. The change in the average Fe CN with Co substitution was examined by analysis of a 3D plot, which compared all of the changes observed in the spectra. This type of analysis gives an accurate depiction of the change in Fe CN as compared to standard materials. The Fe K-edge peak intensities in Ca{sub 2-y}Sr{sub y}Fe{sub 2}O{sub 5} decreased with higher values of y, a result of decreased Fe 4p(3d)-O 2p overlap with increasing Sr concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spontaneous and strong multi-layer graphene n-doping on soda-lime glass and its application in graphene-semiconductor junctions

Scalable and low-cost doping of graphene could improve technologies in a wide range of fields such as microelectronics, optoelectronics, and energy storage. While achieving strong p-doping is relatively straightforward, non-electrostatic approaches to n-dope graphene, such as chemical doping, have yielded electron densities of 9.5 × 10 12 e/cm 2 or below. Furthermore, chemical doping is susceptible to degradation and can adversely affect intrinsic graphene’s properties. Here we demonstrate strong (1.33 × 10 13 e/cm 2 ), robust, and spontaneous graphene n-doping on a soda-lime-glass substrate via surface-transfer doping from Na without any external chemical, high-temperature, or vacuum processes. Remarkably, the n-doping reaches 2.11 × 10 13 e/cm 2 when graphene is transferred onto a p-type copper indium gallium diselenide (CIGS) semiconductor that itself has been deposited onto soda-lime-glass, via surface-transfer doping from Na atoms that diffuse to the CIGS surface. Using this effect, we demonstrate an n-graphene/p-semiconductor Schottky junction with ideality factor of 1.21 and strong photo-response. As a result, the ability to achieve strong and persistent graphene n-doping on low-cost, industry-standard materials paves the way toward an entirely new class of graphene-based devices such as photodetectors, photovoltaics, sensors, batteries, and supercapacitors.

14 SOLAR ENERGY↗

Low-Temperature, Solution-Processed Molybdenum Oxide Hole-Collection Layer for Organic Photovoltaics

We have utilized a commercially available metal-organic precursor to develop a new, low-temperature, solution-processed molybdenum oxide (MoO{sub x}) hole-collection layer (HCL) for organic photovoltaic (OPV) devices that is compatible with high-throughput roll-to-roll manufacturing. Thermogravimetric analysis indicates complete decomposition of the metal-organic precursor by 115 C in air. Acetonitrile solutions spin-cast in a N{sub 2} atmosphere and annealed in air yield continuous thin films of MoO{sub x}. Ultraviolet, inverse, and X-ray photoemission spectroscopies confirm the formation of MoO{sub x} and, along with Kelvin probe measurements, provide detailed information about the energetics of the MoO{sub x} thin films. Incorporation of these films into conventional architecture bulk heterojunction OPV devices with poly(3-hexylthiophene) and [6,6]-phenyl-C{sub 61} butyric acid methyl ester afford comparable power conversion efficiencies to those obtained with the industry-standard material for hole injection and collection: poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS). The MoO{sub x} HCL devices exhibit slightly reduced open circuit voltages and short circuit current densities with respect to the PEDOT:PSS HCL devices, likely due in part to charge recombination at Mo{sup 5+} gap states in the MoO{sub x} HCL, and demonstrate enhanced fill factors due to reduced series resistance in the MoO{sub x} HCL.

14 SOLAR ENERGY↗

Characterization of extreme ultraviolet laser ablation mass spectrometry for actinide trace analysis and nanoscale isotopic imaging

The purpose of this research was to characterize Extreme Ultraviolet Time-of-Flight (EUV TOF) Laser Ablation Mass Spectrometry for high spatial resolution elemental and isotopic analysis. We compare EUV TOF results with Secondary Ionization Mass Spectrometry (SIMS) to orient the EUV TOF method within the overall field of analytical mass spectrometry. Using the well-characterized NIST 61x glasses, we show that the EUV ionization approach produces relatively few molecular ion interferences in comparison to TOF SIMS. We demonstrate that the ratio of element ion to element oxide ion is adjustable with EUV laser pulse energy and that the EUV TOF instrument has a sample utilization efficiency of 0.014%. The EUV TOF system also achieves a lateral resolution of 80 nm and we demonstrate this lateral resolution with isotopic imaging of closely spaced particles or uranium isotopic standard materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preparation, characterization, and optical properties of nano- and submicron-sized Y{sub 2}O{sub 3}:Eu{sup 3+} phosphors

Ultrafine Y{sub 2}O{sub 3}:Eu{sup 3+} phosphors were prepared by a modified solution combustion method. The as-prepared samples with sizes of 17.6-80 nm (nanophosphors) and 300 nm (submicron phosphors) were characterized by x-ray diffraction, transmission electron microscope, scanning electron microscopy, selected area electron diffraction, and energy dispersive x-ray spectroscopy. The emission spectra of the samples are unchanged in comparison with that of standard material. The excitation spectra show a redshift in the charge-transfer-state band and a blueshift in the host gap band. In relation to commercial sample, the relative luminescence intensities of nano- and submicron phosphors are increased sufficiently to 64.4% and 93.6%, respectively. Higher quenching concentration of the activator Eu{sup 3+} ion was observed in the nanophosphor than that in the phosphor synthesized by solid state reaction.

36 MATERIALS SCIENCE↗

Shock Hugoniot and temperature data for polystyrene obtained with quartz standard

Equation-of-state data, not only pressure and density but also temperature, for polystyrene (CH) are obtained up to 510 GPa. The region investigated in this work corresponds to an intermediate region, bridging a large gap between available gas-gun data below 60 GPa and laser shock data above 500 GPa. The Hugoniot parameters and shock temperature were simultaneously determined by using optical velocimeters and pyrometers as the diagnostic tools and the {alpha}-quartz as a new standard material. The CH Hugoniot obtained tends to become stiffer than a semiempirical chemical theoretical model predictions at ultrahigh pressures but is consistent with other models and available experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calorimetric low temperature detectors for low-energetic heavy ions and their application in accelerator mass spectrometry

The energy-sensitive detection of heavy ions with calorimetric low temperature detectors was investigated in the energy range of E=0.1-1 MeV/amu, commonly used for accelerator mass spectrometry (AMS). The detectors used consist of sapphire absorbers and superconducting aluminum transition edge thermometers operated at T{approx}1.5 K. They were irradiated with various ion beams ({sup 13}C,{sup 197}Au,{sup 238}U) provided by the VERA tandem accelerator in Vienna, Austria. The relative energy resolution obtained was {Delta}E/E=(5-9)x10{sup -3}, even for the heaviest ions such as {sup 238}U. In addition, no evidence for a pulse height defect was observed. This performance allowed for the first time to apply a calorimetric low temperature detector in an AMS experiment. The aim was to precisely determine the isotope ratio of {sup 236}U/{sup 238}U for several samples of natural uranium, {sup 236}U being known as a sensitive monitor for neutron fluxes. Replacing a conventionally used detection system at VERA by the calorimetric detector enabled to substantially reduce background from neighboring isotopes and to increase the detection efficiency. Due to the high sensitivity achieved, a value of {sup 236}U/{sup 238}U=6.1x10{sup -12} could be obtained, representing the smallest {sup 236}U/{sup 238}U ratio measured at the time. In addition, we contributed to establishing an improved material standard of {sup 236}U/{sup 238}U, which can be used as a reference for future AMS measurements.

43 PARTICLE ACCELERATORS↗

Shock-wave equation-of-state measurements in fused silica up to 1600 GPa

The properties of silica are important to geophysical and high-pressure equation of state research. The most prevalent crystalline form, α-quartz, has been extensively studied to TPa pressures. Recent experiments with amorphous silica, commonly referred to as fused silica, provided Hugoniot and reflectivity data up to 630 GPa using magnetically-driven aluminum impactors. This article presents measurements of the fused silica Hugoniot over the range from 200 to 1600 GPa using laser-driven shocks with a quartz standard. These results extend the measured Hugoniot of fused silica to higher pressures, but more importantly, in the 200-600 GPa range, the data are very good agreement with those obtained with a different driver and standard material. As a result, a new shock velocity-particle velocity relation is derived to fit the experimental data.

58 GEOSCIENCES↗

Magnetic cooling close to a quantum phase transition—The case of Er{sub 2}Ti{sub 2}O{sub 7}

Magnetic cooling, first introduced in the late twenties of last century, has regained considerable interest recently as a cost-efficient and easy-to-handle alternative to {sup 3}He-based refrigeration techniques. Especially, adiabatic demagnetization of paramagnets—the standard materials for magnetic refrigeration—has become indispensable for the present space applications. To match the growing demand for increasing the efficiency in these applications, a new concept for magnetic cooling based on many-body effects around a quantum-critical-point has been introduced and successfully tested [B. Wolf et al., Proc. Natl. Acad. Sci. U.S.A. 108, 6862 (2011)]. By extending this concept to three-dimensional magnetic systems, we present here the magnetothermal response of the cubic pyrochlore material Er{sub 2}Ti{sub 2}O{sub 7} in the vicinity of its B-induced quantum-critical point which is located around 1.5 T. We discuss performance characteristics such as the range of operation, the efficiency, and the hold time. These figures are compared with those of state-of-the-art paramagnetic coolants and with other quantum-critical systems which differ by the dimensionality of the magnetic interactions and the degree of frustration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the Hugoniot and shock-induced phase transition stress in wrought 17-4 PH H1025 stainless steel

Uniaxial strain, reverse-ballistic impact experiments were performed on wrought 17-4 PH H1025 stainless steel, and the resulting Hugoniot was determined to a peak stress of 25 GPa through impedance matching to known standard materials. The measured Hugoniot showed evidence of a solid–solid phase transition, consistent with other martensitic Fe-alloys. The phase transition stress in the wrought 17-4 PH H1025 stainless steel was measured in a uniaxial strain, forward-ballistic impact experiment to be 11.4 GPa. Linear fits to the Hugoniot for both the low and high pressure phase are presented with corresponding uncertainty. The low pressure martensitic phase exhibits a shock velocity that is weakly dependent on the particle velocity, consistent with other martensitic Fe-alloys.

36 MATERIALS SCIENCE↗

Extreme nonlinear electrodynamics in metamaterials with very small linear dielectric permittivity

We consider a subwavelength periodic layered medium whose slabs are filled by arbitrary linear metamaterials and standard nonlinear Kerr media and show that the homogenized medium behaves as a Kerr medium whose parameters can assume values not available in standard materials. Exploiting such a parameter availability, we focus on the situation where the linear relative dielectric permittivity is very small, thus allowing the observation of the extreme nonlinear regime where the nonlinear polarization is comparable with or even greater than the linear part of the overall dielectric response. The behavior of the electromagnetic field in the extreme nonlinear regime is very peculiar and characterized by interesting features such as the transverse power flow reversing. In order to probe this regime, we consider a class of fields (transverse magnetic nonlinear guided waves) admitting full analytical description and show that these waves are allowed to propagate even in media with {epsilon}<0 and {mu}>0 since the nonlinear polarization produces a positive overall effective permittivity. The considered nonlinear waves exhibit, in addition to the mentioned features, a number of interesting properties like hyperfocusing induced by the phase difference between the field components.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-peaked and flat-top perfect bright solitons in nonlinear metamaterials with epsilon near zero

We investigate analytically transverse-magnetic spatial bright solitons, as exact solutions of Maxwell's equations, propagating through nonlinear metamaterials whose linear dielectric permittivity is very close to zero and whose effective nonlinear Kerr parameters can be tailored to achieve values not available in standard materials. Exploiting the fact that, in the medium considered, linear and nonlinear polarization can be comparable at feasible and realistic optical intensities, we identify two self-trapping mechanisms able to support two-peaked and flat-top solitons, respectively. Specifically, these two mechanisms are based on the occurrence of critical points at which the effective nonlinear permittivity vanishes, the two mechanisms differing in the way the compensation between linear and nonlinear polarization is achieved through the nonstandard values of the nonlinear parameters.

36 MATERIALS SCIENCE↗

Na Diffusion and Device Performance of AgBr Treated CuGaSe 2 Thin Films

Previous work demonstrated that uniform CuGaSe2 (CGS) thin films with large grains could be grown using a short AgBr vapor treatment during growth. Here, devices made with this treated CGS showed better performance compared to devices made with standard material. Here, it is shown that AgBr treated CGS device performance worsens over time and is attributed to the suppression of Na diffusion. A NaF post-deposition treatment is shown to effectively introduce Na into the AgBr treated CGS film and prevent device degradation.

14 SOLAR ENERGY↗

The Influence of Strain Path and Heat Treatment Variations on Recrystallization in Cold-Rolled High-Purity Niobium Polycrystals

With the standard material and cavity production guidelines, the properties and performance of industrially produced high-purity niobium superconducting radiofrequency (SRF) cavities are unpredictably variable. Currently, assembled niobium SRF cavities undergo post-purification vacuum heat treatment at 800 °C for three hours to remove hydrogen and increase performance; however, recent work has shown significant improvements in cavity performance when annealed between 900–1000 °C, causing recrystallization (Rx). Increasing the annealing temperature and/or the heating rate should facilitate the onset of Rx, resulting in a greater reduction in the density of geometrically necessary dislocations (GNDs) that are strongly associated with the degradation of cavity performance via trapped magnetic flux. Improving the SRF community's understanding of the influence of both heat treatment and deformation history on the resulting microstructure and Rx behavior in high-purity niobium is needed. This fundamental metallurgy is critical for identifying improved specifications for the consistent production of high-performing niobium SRF cavities. This research investigates variations in deformation paths, heating rates, and annealing temperatures on Rx of deformed samples of polycrystalline high-purity niobium. To assess the effects of strain path, samples were cold-rolled to ~30% reduction prior to annealing, with half of the sample set rolled parallel to the as-received niobium sheet and the other half in the transverse direction.

36 MATERIALS SCIENCE↗

The liquidus temperature of nuclear waste glasses: an international Round-Robin Study

Ten institutions from five countries participated in a Round Robin study to contribute to the Precision and Bias section of an American Society for Testing and Materials standard procedure that Pacific Northwest National Laboratory (PNNL) is developing for measuring the liquidus temperature (TL) of radioactive and simulated waste glasses. In this study, three separate TL measurement methods were a gradient temperature (GT) method, a uniform temperature (UT) method, and a crystal fraction extrapolation (CF) method. Three different glasses were measured with a combination of these three methods. The TL values reported by different institutions are generally consistent and vary within a narrow range. The precision of a TL measurement was evaluated as ±10°C regardless of the method used for making the measurement. The Round Robin glasses were all previously studied at PNNL and included ARG-1 (Glass A), Zr-9 (Glass B), and AmCm2-19 (Glass C), with measured TL values spanning the temperature range ~960-1240°C. The three methods discussed here in more detail are the GT, UT, and CF methods. A best-case precision for TL has been obtained from the data, even though the data were not acquired for all three glasses using all three methods from each participating organization.

ASTM↗

Accurate Determination of the Values of Fundamental Physical Constants: The Basis of the New “Quantum” SI Units

The metric system appeared as the system of units designed for macroscopic (laboratory scale) measurements. The progress in accurate determination of the values of quantum constants (such as the Planck constant) in SI units shows that the capabilities in high-precision measurement of microscopic and macroscopic quantities in terms of the same units have increased substantially recently. At the same time, relative microscopic measurements (for example, the comparison of atomic transition frequencies or atomic masses) are often much more accurate than relative measurements of macroscopic quantities. This is the basis for the strategy to define units in microscopic phenomena and then use them on the laboratory scale, which plays a crucial role in practical methodological applications determined by everyday life and technologies. The international CODATA task group on fundamental constants regularly performs an overall analysis of the precision world data (the so-called Adjustment of the Fundamental Constants ) and publishes their recommended values. The most recent evaluation was based on the data published by the end of 2014; here, we review the corresponding data and results. The accuracy in determination of the Boltzmann constant has increased, the consistency of the data on determination of the Planck constant has improved; it is these two dimensional constants that will be used in near future as the basis for the new definition of the kelvin and kilogram, respectively. The contradictions in determination of the Rydberg constant and the proton charge radius remain. The accuracy of determination of the fine structure constant and relative atomic weight of the electron has improved. Overall, we give a detailed review of the state of the art in precision determination of the values of fundamental constants. The mathematical procedure of the Adjustment, the new data and results are considered in detail. The limitations due to macroscopic properties of material standards (such as the International prototype of the kilogram) and the isotopic composition of substances involved in precision studies in general (as standard measures for the triple point of water) and, in particular, in the determination of the fundamental constants are discussed. The perspectives of the introduction of the new quantum units, which will be free from the mentioned problems, are considered. Many physicists feel no sympathy for the International system of units (SI), believing that it does not properly reflect the character of physical laws. In fact, there are three parallel systems, namely the systems of quantities, system of their units and the related standards. The definition of the units, in particular, the SI units, above all, reflects our ability to perform precision measurements of physical values under certain conditions, in particular, to create appropriate standards. This requirement is not related to the beauty of fundamental laws of nature. More accurate determination of the fundamental constants is one of the areas where we accumulate such experience.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗