Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A high-capacity Sn metal anode for aqueous acidic batteries

Aqueous acidic batteries as a good choice to respond battery diversity, delivering safety, cost, environmental friendliness and high-power necessary for renewable energy storage. However, the practical adoption is greatly challenged by low-voltage and energy density due to the inadequate metal anode materials. Here we report an interfacial regulated Sn metal anode as the solution of the last piece of the puzzle. In this study, the ease of recycling, low potential, fast redox kinetics, and high capacity of Sn perfectly fit the battery system, and the Sn metal shedding critical issue is successfully suppressed by promoting uniform deposition for added interaction from alloying. Consequently, this reversible Sn anode with 442 mAh g -1 matches well to different types of cathodes. The as-assembled acidic batteries also demonstrate sufficient output voltage (up to 1.7 V), energy density (up to 312 Wh kg -1 based on both electrodes), kinetics (up to 24 C) and stability (up to 2400 cycles).

25 ENERGY STORAGE↗

Design and Demonstration of an 850 V dc to 13.8 kV ac 100 kW Three-phase Four-wire Power Conditioning System Converter Using 10 kV SiC MOSFETs

In this paper, an 850 V dc to 13.8 kV ac 100 kW modular multilevel three-phase four-wire dc/ac converter based on 10 kV SiC MOSFETs is designed and demonstrated. The design considerations of key components, including the dc-link, device cooling, gate driver, isolated gate driver power supply (GDPS), medium voltage (MV) ac filter inductor, MV and medium frequency transformer, and the mechanical design are discussed. Two converters are designed, and two prototypes are developed, to study the converter paralleling operation and scalability. Both converters are fully tested up to their voltage and power ratings. However, the two converters are not identical. Based on the design and test results of the first converter, the MV power stage, transformer design, GDPS, as well as the low voltage power stage in the second converter are improved for smaller size and/or higher efficiency. Compared to the version 1 converter, the version 2 converter achieves 49% volume reduction and 2 percentage point efficiency improvement, with a peak efficiency of 98.4% at the rated power.

Li, Haiguo↗

Hydroxide Exchange Membrane Carbon Capture (HEMCC) Using Nickel Hydroxide Batteries and Flow-through Membranes

Proposed is an electrochemical nickel hydroxide based hydroxide exchange membrane carbon capture (HEMCC) device for Direct Air Capture (DAC) of CO2. DAC has been identified as one of the key net negative carbon technologies to achieve net zero carbon emissions. Net negative carbon technologies are required to offset continued emissions from dilute CO2 sources such as agriculture and construction. The majority of current DAC technologies at scale (>1 KT∙yr-1) are adsorbent based technologies with significant energy cost. The traditional DAC energy cost is primarily driven by the temperature swing required to regenerate the sorbent and has been shown to be 1.8 MWh·ton-1 at the system level. Electrochemical pH swing devices are a growing research area for carbon capture devices with the goal of lowering the energy cost required for DAC. A pH gradient is built by generating OH- at the cathode and consuming OH- at the anode. An acid-base equilibrium with CO2 allows for the capture of CO2 at the cathode and release at the anode. This extends from other electrochemical CO2 capture devices based on pKa shifts of an electrochemically active organic species allowing for the capture and release of CO2. Electrochemical CO2 capture is considered promising based on potentially low energy costs to capture CO2 in comparison with current temperature swing adsorption technologies. This work explores Ni(OH)2 electrodes to produce the pH gradient for CO2 capture and release. At the cathode NiOOH is reduced to Ni(OH)2 while at the anode Ni(OH)2 is oxidized to NiOOH. The symmetrical electrodes allow for a low voltage requirement; the thermodynamic potential difference of standard electrochemical reactions is zero. Most of the voltage observed is to produce the pH gradient with the remainder driving the polarization of the electrodes. There is a resistance component as well, but this is small in comparison due to the low current densities used in the device, nominally 2 mA·cm-1. Two similar devices are presented, a traditional MEA (membrane electrode assembly) and a flow-through MEA. The traditional MEA separates the two Ni(OH)2 electrodes with an 80μm Piperion® membrane. While the flow-through membrane separates the electrodes with a three piece membrane consisting of two 80μm Piperion® membranes with a porous membrane between them. In the traditional MEA system air is passed over the cathode for capture, while the flow-through MEA the air is passed through the porous membrane isolated from the electrodes. The traditional MEA has been used to establish a baseline performance of the device and has been shown to capture CO2 at an energy cost of 1 MWh·ton-1 at the device level. An understanding has been built around the components of that energy cost including the relationship of flux to current density, effect of a regeneration process, transient battery behavior, and gas losses coinciding with changing the polarization of the batteries. The flow-through MEA looks to address of transient battery behavior and gas losses. It allows for denser, higher capacity electrodes, which can lean on traditional Ni-MH battery technology used in alkaline batteries used today. The higher capacities, limit the transient battery effect on flux in the device. Gas losses are addressed by having a continuous inlet air stream to the device and continuous outlet product.

Buchen, James↗

All-MOCVD-grown gallium nitride diodes with ultra-low resistance tunnel junctions

In this work, we carefully investigate three important effects including postgrowth activation annealing, delta (δ) dose and magnesium (Mg) buildup delay as well as experimentally demonstrate their influence on the electrical properties of GaN homojunction p–n diodes with a tunnel junction (TJ). The diodes were monolithically grown by metalorganic chemical vapor deposition (MOCVD) in a single growth step. By optimizing the annealing parameters for Mg activation, δ-dose for both donors and acceptors at TJ interfaces, and p + -GaN layer thickness, a significant improvement in tunneling properties is achieved. For the TJs embedded within the continuously-grown, all-MOCVD GaN diode structures, ultra-low voltage penalties of 158 mV and 490 mV are obtained at current densities of 20 A cm –2 and 100 A cm –2 , respectively. The diodes with the engineered TJs show a record-low differential resistivity of 1.6 × 10 –4 Ω cm 2 at 5 kA cm –2 .

42 ENGINEERING↗

Cooperative Model Predictive Control Scheme for Dispersed Smart Inverters at the Grid Edge

Growing number of distributed energy resources (DERs) requires cutting-edge control schemes to ensure uniform but not identical involvement of DERs to address rapid fluctuations on voltage of the grid clusters. Designing such control schemes for a grid with high penetration of DERs connected various clusters is complex and depends on physical configuration of the clusters themselves. This paper proposes a two-layered cooperative model predictive control scheme for fleet of dispersed smart inverters connected to a three-phase grid cluster located at the edge of a grid cluster. The upper layer of the controller ensures cooperative operation of fleet of smart inverters to perform voltage regulation and address voltage fluctuations in the grid cluster; while the lower level controller guarantees each individual inverter obeys the dictated references for active/reactive powers by the upper layer controller. In addition, the proposed twolayered controller has low voltage ride through (LVRT) capability to support the grid clusters during voltage sags. By employing the proposed control approach, the smart inverters will inject desired active/reactive powers based on circumstance of the entire cluster while guaranteeing proper power curtailment among the generation units. The control scheme is verified by simulation.

Fard, Amin Y.↗

Status of the Mu2e calorimeter readout electronics

The Mu2e experiment [1] at Fermilab will search for the neutrino-less coherent conversion of a muon into an electron in the field of a nucleus. Mu2e detectors comprise a straw tracker, an electromagnetic calorimeter and a veto for cosmic rays. The calorimeter employs 1348 Cesium Iodide crystals readout by silicon photomultipliers and fast front-end and digitization electronics. The front-end electronics consists of two discrete readout circuits (AMP-HV) for each crystal. These provide the amplification, shaping stage and linear regulation of the SiPM bias voltage and monitoring. The SiPM and front-end control electronics is implemented in a battery of mezzanine boards each equipped with an ARM processor that controls a group of 20 Amp-HV circuits distributing the low voltage and the high-voltage. The electronic is hosted in crates located on the external surface of calorimeter disks. The crates also host the waveform digitizer board (DIRAC) that performs digitization of the front end signals and transmit the digitized data to the Mu2e DAQ. Calorimeter electronic is hosted inside the cryostat and must sustain very high radiation and magnetic field so it was necessary to fully qualify it. The system design and quality assurance procedures will be reviewed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hypochlorite Redox Chemistry Enables High-Voltage and High-Power Saltwater Batteries

Saltwater batteries (SWBs) are promising alternatives to lithium-ion batteries for large-scale stationary energy storage. However, the performance of conventional oxygen redox-based saltwater battery systems is often constrained by sluggish oxygen evolution and reduction reactions (OER/ORR) at the cathode, leading to low voltage efficiency and limited power density. Here, OER and ORR are replaced by hypochlorite-based redox reactions through the introduction of sodium hypochlorite into saltwater. Operando pH and dissolved oxygen measurements confirm that OER and ORR are minimized and that hypochlorite redox reactions dominate the cathode behavior. Owing to the higher operating potential and faster reaction kinetics, the hypochlorite-redox-based SWBs delivers a higher discharge voltage of 3.3 V and reduced charge-discharge voltage polarization to 0.66 V. Further improvement is achieved by adjusting the saltwater pH to near-neutral conditions, increasing the discharge voltage to 3.5 V and more than doubling the peak power. The hypochlorite redox environment also exhibits chemical stability with key cell components, including the solid electrolyte and cathode current collectors. Operation of series-connected cells and cells employing hard carbon anodes demonstrates scalability and compatibility with alternative anode materials. These results provide a strong foundation for next-generation SWBs targeting large-scale stationary energy storage applications.

Go, Wooseok [ORNL]↗

Demonstration of resonant tunneling effects in metal-double-insulator-metal (MI2M) diodes

Abstract Although the effect of resonant tunneling in metal-double-insulator-metal (MI 2 M) diodes has been predicted for over two decades, no experimental demonstrations have been reported at the low voltages needed for energy harvesting rectenna applications. Using quantum-well engineering, we demonstrate the effects of resonant tunneling in a Ni/NiO/Al 2 O 3 /Cr/Au MI 2 M structures and achieve the usually mutually exclusive desired characteristics of low resistance ( $${R}_{0}^{DC} \sim$$ R 0 D C ~ 13 kΩ for 0.035 μm 2 ) and high responsivity ( β 0 = 0.5 A W −1 ) simultaneously. By varying the thickness of insulators to modify the depth and width of the MI 2 M quantum well, we show that resonant quasi-bound states can be reached at near zero-bias, where diodes self-bias when driven by antennas illuminated at 30 THz. We present an improvement in energy conversion efficiency by more than a factor of 100 over the current state-of-the-art, offering the possibility of engineering efficient energy harvesting rectennas.

42 ENGINEERING↗

A disordered rock salt anode for fast-charging lithium-ion batteries

Rechargeable lithium-ion batteries with high energy density that can be safely charged and discharged at high rates are desirable for electrified transportation and other applications. However, the sub-optimal intercalation potentials of current anodes result in a trade-off between energy density, power and safety. In this paper we report that disordered rock salt Li 3+ x V 2 O 5 can be used as a fast-charging anode that can reversibly cycle two lithium ions at an average voltage of about 0.6 volts versus a Li/Li + reference electrode. The increased potential compared to graphite reduces the likelihood of lithium metal plating if proper charging controls are used, alleviating a major safety concern (short-circuiting related to Li dendrite growth). In addition, a lithium-ion battery with a disordered rock salt Li 3 V 2 O 5 anode yields a cell voltage much higher than does a battery using a commercial fast-charging lithium titanate anode or other intercalation anode candidates (Li 3 VO 4 and LiV 0.5 Ti 0.5 S 2 ). Further, disordered rock salt Li 3 V 2 O 5 can perform over 1,000 charge–discharge cycles with negligible capacity decay and exhibits exceptional rate capability, delivering over 40 per cent of its capacity in 20 seconds. We attribute the low voltage and high rate capability of disordered rock salt Li 3 V 2 O 5 to a redistributive lithium intercalation mechanism with low energy barriers revealed via ab initio calculations. This low-potential, high-rate intercalation reaction can be used to identify other metal oxide anodes for fast-charging, long-life lithium-ion batteries.

25 ENERGY STORAGE↗

Transmission and Distribution Real-Time Analysis Software for Monitoring and Control: Design and Simulation Testing

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. This paper introduces software designed to meet these challenges. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. The software architecture along with selected analysis modules is presented. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hardware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

14 SOLAR ENERGY↗

Piezo-optomechanical cantilever modulators for VLSI visible photonics

Visible-wavelength very large-scale integration photonic circuits have a potential to play important roles in quantum information and sensing technologies. The realization of scalable, high-speed, and low-loss photonic mesh circuits depends on reliable and well-engineered visible photonic components. Here, we report a low-voltage optical phase shifter based on piezo-actuated mechanical cantilevers, fabricated on a CMOS compatible, 200 mm wafer-based visible photonics platform. We show linear phase and amplitude modulation with 6 V π cm in differential operation, −1.5 to −2 dB insertion loss, and up to 40 dB contrast in the 700–780 nm range. By adjusting selected cantilever parameters, we demonstrate a low-displacement and a high-displacement device, both exhibiting a nearly flat frequency response from DC to a peak mechanical resonance at 23 and 6.8 MHz respectively, which, through resonant enhancement of Q ∼ 40, further decreases the operating voltage down to 0.15 V π cm.

Dong, Mark↗

Exploring transport mechanisms in atomic precision advanced manufacturing enabled pn junctions

We investigate the different transport mechanisms that can occur in pn junction devices made using atomic precision advanced manufacturing at temperatures ranging from cryogenic to room temperature. We first elucidate the potential cause of the anomalous behavior observed in the forward-bias response of these devices in recent cryogenic temperature measurements, which deviates from the theoretical response of a silicon Esaki diode. These anomalous behaviors include current suppression at low voltages in the forward-bias response and a much lower valley voltage at cryogenic temperatures than theoretically expected for a silicon diode. To investigate the potential causes of these anomalies, we studied the effects of a few possible transport mechanisms, including band-to-band tunneling, bandgap narrowing, potential impact of non-Ohmic contacts, band quantization, impact of leakage, and inelastic trap-assisted tunneling, through semi-classical simulations. We find that a combination of two sets of band-to-band tunneling (BTBT) parameters can qualitatively approximate the shape of the tunneling current at low bias. This can arise from band quantization and realignment due to the strong potential confinement in δ-layers. We also find that the lower-than-theoretically-expected valley voltage can be attributed to modifications in the electronic band structure within the δ-layer regions, leading to a significant bandgap narrowing induced by the high density of dopants. Finally, we extend our analyses to room temperature operation and predict that trap-assisted tunneling (TAT) facilitated by phonon interactions may become significant, leading to a complex superposition of BTBT and TAT transport mechanisms in the electrical measurements.

band gap↗

Electrical Switching of Nematic Plasmonic Nanocolloids for Infrared Solar Gain Control

Controlling solar gain is essential to reduce the energy consumption by residential and commercial buildings, which are responsible for ≈40% of all energy generated globally. However, the dynamic control of solar gain in the near-infrared that corresponds to ≈50% of the overall Sun's energy at the Earth's surface, separately from the visible spectral range has been a challenge, albeit commercial coatings provide passive control while retaining highly visible transmission. To address this problem, in this paper switchable silver colloids (SSCs) are demonstrated, colloidal analogs of the common silver coatings used for solar gain control. When dispersed in a nematic liquid crystal, orientations of such plasmonic silver nanoplates are controlled by ≈1 V low-voltage electric fields, allowing for sub-second switching of the near-infrared-based solar gain. Installed and retrofit products made from thin films of such nanoplate dispersions confined between glass and plastic substrates, respectively, exhibit electrically controlled infrared-based solar gain while retaining high visible-range transparency, low haze, and high color rendering index. Furthermore, this study's findings reveal a great potential of soft-matter systems in addressing energy-related problems.

36 MATERIALS SCIENCE↗

Co-free gradient lithium-rich cathode for high-energy batteries with optimized cyclability

Lithium-rich layered oxides (LLOs) hold the promise for high-energy battery cathodes. However, its application has been hindered by voltage decay associated with irreversible reactions at high voltages despite decades of intensive efforts. Here, we first theoretically studied the molecular orbitals of Mn-based Li-rich configurations. We found that the π-bond ring formed within the LiMn 6 structure could participate in stable redox reactions as one unit, but Co could disrupt its symmetry. We thus designed and synthesized Co-free concentration-gradient LLOs (CF-CG-LLOs) materials. The combination of concentration gradient and Co removal leads to exceptional capacity retention without any fading over 100 cycles of the pouch cell. More importantly, it exhibits an extraordinarily low voltage decay of 0.15 mV/cycle, accompanied by a high Coulombic efficiency of 99.86%. This concept and demonstration of CF-CG-LLO cathodes reveal a viable avenue toward low-cost, high-energy-density battery cathodes.

25 ENERGY STORAGE↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Challenges of Modeling Distributed Energy Resources (DERs) as Blackstart Resources and for Volt-VAR Optimality

Modeling, testing and instituting Distributed Energy Resources (DERs) as Blackstart Resoucrces presents several challenges due to the fundamental differences between traditional black start resources (e.g., large generators) versus DERs like solar PV systems with battery storage. This paper addresses some of these key challenges. These include intermittency of coordinating DERs to provide continuous power during a black start event, especially during extended periods of cloud cover or when battery energy storage is depleted. This paper additionally addresses the collapsing voltage and stability control challenges specific to maintaining bulk power system stability during black start synchronization These physical and engineering limitations require careful engineering design, modeling and engineering to ensure that DERs can support critical loads and substations during black start events. A variety of additional challenges also exist. Additionally, there are challenges associated with feeder location and low voltage secondary system impacts on DER functions and settings. We compare typical functions and settings for DERs for power factor control and correction. We also demonstrate how voltag control via Volta-VAR power factor correction can be done

Mukherjee, Srijib↗

Photovoltaic Inverter Momentary Cessation: Recovery Process is Key

Momentary cessation refers to an inverter control mode. When the inverter terminal voltage falls below (or exceeds) a certain level, the inverter ceases to output any current, but attempts to maintain (or quickly regain) phase-locked loop synchronization to allow for quick reinjection of current when the voltage recovers to a certain point. This paper presents a photovoltaic (PV) momentary cessation model developed in PSS/E. Simulations are presented for a high voltage transmission line fault contingency in the Hawaiian island of Oahu power system on a validated PSS/E model, modified to include a custom distributed PV inverter model, and different near-future distributed PV penetration levels. Simulations for the island power system include different penetration levels of PV, and different recovery times (ramp rates and delays) after momentary cessation. The results indicate that during low voltage events, such as faults, momentary cessation can produce severe under frequency events, causing significant load shed and shortly thereafter, in some cases, over frequency events that cause generation to trip offline. The problem is exacerbated with higher penetration levels of PV. If momentary cessation is used (as is typically the case for distribution-connected resources), the recovery process after momentary cessation should be carefully considered to minimize impacts to bulk power system stability.

14 SOLAR ENERGY↗

Revealing the Roles of CuF 2 /NiF 2 Incorporation in the Electrochemical Performance of FeF 3 Cathodes in Solid‐State Batteries

Mixed metal fluorides have been considered as a promising candidate to lower the voltage hysteresis of conversion-type iron fluoride cathodes, but their cycling stability is limited due to transition metal dissolution and interphase growth in liquid electrolyte batteries. Here, we study the role of incorporating CuF 2 and NiF 2 in the electrochemical performance of FeF 3 cathode in halide-based solid-state batteries to test whether we can transfer the kinetic benefit of low voltage hysteresis to solid-state batteries while using solid electrolyte to eliminate transition metal dissolution and stabilize the interphase. Synchrotron X-ray absorption spectroscopy results indicated the redox reactions are attributed to Cu 0 /Cu + and Fe 0 /Fe 2+ in 25CuF 2 -75FeF 3 and Ni 0 /Ni 2+ and Fe 0 /Fe 3+ in 10NiF 2 -90FeF 3 . While no apparent improvement in electrode kinetics can be observed, the incorporation of CuF 2 and NiF 2 can largely improve the cycling stability of FeF 3 cathodes. In conclusion, the results demonstrate the advantages of using solid-state concept to improve the cycling stability of conversion-type cathodes.

25 ENERGY STORAGE↗