Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lost production”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Alabama Disasters: Leveraging NASA EOS to Explore the Environmental and Economic Impact of the April 27 Tornado Outbreak

The disastrous tornado outbreak in Alabama on April 27, 2011 greatly impacted the economy of the state. On record, the tornado outbreak was the second deadliest tornado outbreak in U.S. When considering the agricultural and value-added activities such as food and timber processing, farm inputs, manufacturing, transportation, and retail sales, the dollar value of Alabama agribusiness annually exceeds $40 billion (NASS, 2011). This research aims to examine how the timber and agriculture damage affected the state economy of Alabama and will be used to aid in long-term economic recovery. ASTER imagery was used along with ground-truthed NASS (National Agriculture Statistics Service) crop location records to verify the economic impact tornadoes had on the agricultural economy of the state. This swath damage can be calculated by correlating tornado path with NASS statistics on crop yield, precisely showing the fields affected and dollars lost to this disaster. Not only can this be executed manually using ENVI and ArcGIS, but also through the use of Python, a programming language that has the ability to automate the process, creating a product for initial damage assessment.

Herdy, Claire↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Consolidation and Permeability of the B1 and D1 Gas Hydrate Bearing Sands and Associated Seal Sediments of the Extended-Duration Gas Production Test Site on the Alaska North Slope

Gas hydrate, a solid combination of gas (mostly methane in nature) and water molecules stable at low temperatures and elevated pressures, occurs naturally in marine and permafrost-associated environments. Gas hydrate reservoirs, such as those in the Alaska North Slope, have been considered potential energy resources for gas production. To understand the petrophysical and geo-mechanical characteristics of the reservoir, core samples retrieved from the site of the JOGMEC-DOE-USGS collaborative gas hydrate R&D project have been analyzed in the laboratory for their hydraulic and mechanical properties. This paper focuses on both seal and reservoir samples associated with the B1 and D1 sands, which are evaluated for index properties (including porosity, grain size distribution, liquid and plastic limits, specific surface area, and specific gravity), consolidation, permeability, and water retention. Furthermore, the reservoir core samples were tested with pore-filling, laboratory-grown tetrahydrofuran hydrate, in order to assess reservoir behavior during gas production from hydrates. Under simulated in situ stress conditions, the seal and hydrate-free reservoir cores had a permeability anisotropy ratio of k h /k v = 3.0−5.0, and k h /k v = 2.4−3.0 for the reservoir tetrahydrofuran hydrate-bearing cores. The data suggest that depressurizing the reservoir to induce hydrate dissociation alters the reservoir effective permeability in three ways: permeabilities decrease due to porosity lost (e.g., the initial reservoir thickness can decrease by up to 5% upon 7 MPa depressurization), permeability increases due to the loss of solid hydrate in the pore space, and permeability anisotropy k h /k v decreases in response to the evolving pore-space geometry. We show that given the simulated in situ gas hydrate saturations (i.e., S h = 32% in core 7P-2E and S h = 21% in core 20P-4), gas production from the dissociation of tetrahydrofuran hydrate in the two tested cores results in a net increase in effective permeability and a decrease in k h /k v . This study highlights the importance of investigating seal and reservoir sediments and the impacts of depressurization on the porosity and permeability responses during production.

Geological materials↗

High Tc screen-printed YBa2Cu3O(7-x) films - Effect of the substrate material

Thick films of YBa2Cu3O(7-x) have been deposited on highly polished alumina, magnesia spinel, nickel aluminum titanate (Ni-Al-Ti), and barium tetratitanate (Ba-Ti) substrates by the screen printing technique. Properties of the films were found to be highly sensitive to the choice of the substrate material. The film on Ba-Ti turned green after firing, due to a reaction with the substrate and were insulating. A film on Ni-Al-Ti had a Tc (onset) of about 95 K and lost 90 percent of its resistance by about 75 K. However, even at 4 K it was not fully superconducting, possibly due to a reaction between the film and the substrate and interdiffusion of the reaction products. The film on alumina had Tc (onset) of about 96 K, Tc (zero) of about 66 K, and Delta Tc of about 10 K. The best film was obtained on spinel and had Tc (onset) of about 94 K, zero resistance at 81 K, and a transition width of about 7 K.

Bansal, Narottam P.↗

Is xenon eldest?

It is well known that the solubility of noble gases in magmas decreases with increasing atomic weight. Xenon, the weightiest of the stable noble gases, is the least soluble atmospheric gas in magma. It is not unreasonable to suppose that the noble gases should have degassed from (or equilibrated with) a bubbling mantle in order of increasing solubility, such that xenon was the most rapidly degassed and helium the least. The apparent relative ages of the famous radiogenic noble gas isotopes agrees, at least qualitatively, with this premise. When atmospheric loss processes are assigned their proper place, several long-standing xenonological puzzles become added evidence for xenon's relative antiquity. Xenon being the afore-mentioned sense the oldest atmospheric gas, will have been most greatly subject to escape, be it impact-driven or EUV-driven. Nonradiogenic xenon's pronounced isotopic fractionation has already been attributed to escape; why it should be more fractionated than krypton would be assigned to xenon's greater atmospheric age. The small atmospheric inventory of xenon relative to the other nonradiogenic noblegases, known as the 'missing xenon' problem, could easily be explained by differential escape. The relatively tiny atmospheric inventories of the radiogenic daughter products of 129 Iodine and 244 Plutonium, both much smaller than would be expected from the inferred abundances of the parents in meteorites, offer a third and fourth data to support the hypothesis that Earth has lost most of its xenon.

Zahnle, K.↗

Project H - A Complete Spaceport Hydrogen Solution

This slide presentation reviews Project H, and its importance in the development of Kennedy Space Center (KSC) as a Spaceport capable of multiple launches. It is known that current KSC cryogenic technology results in only approximately 55 % of purchased hydrogen being used. The rest is lost at various points in the process: transfer from transporting vehicle to tank, storage tank boil off, and from the tank to the intended propulsion tanks. Project H's goals would be to have local hydrogen production and liquifaction capability, and to increase the efficiency of hydrogen operations to greater than 80 %. The project envisions two phases: Phase 1 will build a smaller scale demonstration system, and phase 2 will build a full scale spaceport system. This initial project has proposed ideas for local hydrogen production, gaseous distribution, integrated refrigeration and storage, and high efficiency transfer lines that merit further investigation.

Notardonato, William↗

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗

Reflective Coatings Protect People and Animals

Led by Marshall Space Flight Center, NASA engineers called upon National Metalizing of Cranbury, New Jersey, to help create a reflective sunshield to deploy on Skylab in place of a shield that was lost during launch in 1973. Years later, a former employee for National Metalizing founded Advanced Flexible Materials (AFM) Inc., of Petaluma, California, and utilized the radiant barrier technology in the public domain to produce a variety of products such as wraps to keep marathon finishers safe from hypothermia as well as a lining for mittens and vests. Recently, the material helped to keep manatees warm as they were lifted from the water as part of a tag-and-release program.

Source record↗

Heat Stress to Jeopardize Crop Production in the US Corn Belt Based on Downscaled CMIP5 Projections

CONTEXT Global food security faces increasing challenges from the changing climate. Changes of agricultural output from some of the most productive regions such as the US Corn Belt can largely affect the world's food market. Developing predictive understanding of the agricultural risk of climate change and potential mitigation strategies is critical for the global food security. OBJECTIVE The objective of this study is to assess the responses of maize and soybean yield to projected climate changes in the Corn Belt, identify the shifting environment stressors on crop yield, and tackle potential climate adaptation strategies. METHODS We drive a process-based model, the Decision Support System for Agrotechnology Transfer, with high-resolution statistically downscaled and bias-corrected historical and future climates from ten CMIP5 models in the MACA-2 database. RESULTS AND CONCLUSIONS The multi-model ensemble mean suggests a 12% decrease of maize yield by mid-century and 40% by late century, with a high degree of model consensus in the direction of changes; for individual models, the projected decrease of maize yield by late century ranges from <5% to over 80%, with the worst crop outcome corresponding to the most sensitive climate models. Soybean yield is projected to increase by midcentury with a high degree of model consensus, but such consensus is lost by late century as some projections shift to significant decreases. Crop yield in the Corn Belt is currently limited by water stress, but is projected to be increasingly limited by heat stress as well after the midcentury. The mounting heat stress will drive the most productive zone for maize to shift from central to northern part of the Corn Belt, but the projected increase in the northern states cannot fully compensate for the decrease in the south, causing the total production to decrease if agricultural practice stays the same. Earlier planting can alleviate only a small fraction of the heat-induced crop loss in a warmer climate. Climate change will (at least partially) offset the yield boost caused by agricultural technology and intensification. SIGNIFICANCE This study advances our predictive understanding of crop yield responses to climate change, and suggests that a multitude of strategies will be needed to address the climate change challenges for the U.S. agriculture.

Crop yield↗

A numerical analysis of shipboard and coastal zone color scanner time series of new production within Gulf Stream cyclonic eddies in the South Atlantic Bight

Eddy-induced upwelling occurs along the western edge of the Gulf Stream between Cape Canaveral, Florida, and Cape Hatteras, North Carolina, in the South Atlantic Bight (SAB). Coastal zone color scanner images of 1-km resolution spanning the period April 13-21, 1979, were processed to examine these eddy features in relation to concurrent shipboard and current/temperature measurements at moored arrays. A quasi-one-dimensional (z), time dependent biological model, using only nitrate as a nutrient source, has been combined with a three-dimensional physical model in an attempt to replicate the observed phytoplankton field at the northward edge of an eddy. The model is applicable only to the SAB south of the Charleston Bump, at approximately 31.5 deg N, since no feature analogous to the bump exists in the model bathymetry. The modeled chlorophyll, nitrate, and primary production fields of the euphotic zone are very similar to those obtained from the satellite and shipboard data at the leading edges of the observed eddies south of the Charleston Bump. The horizontal and vertical simulated fluxes of nitrate and chlorophyll show that only approximately 10% of the upwelled nitrate is utilized by the phytoplankton of the modeled grid box on the northern edge of the cyclone, while approximately 75% is lost horizontally, with the remainder still in the euphotic zone after the 10-day period of the model. Loss of chlorophyll due to sinking is very small in this strong upwelling region of the cyclone. The model is relatively insensitive to variations in the sinking parameterization and the external nitrate and chlorophyll fields but is very sensitive to a reduction of the maximum potential growth rate to half that measured. Given the success of this model in simulating the new production of the selcted upwelling region, other upwelling regions for which measurements or successful models of physical and biological quantities and rates exist could be modeled similarly.

Pribble, J. Raymond↗

Co-synthesis of Hydrogen and High-Value Carbon Products from Methane Pyrolysis

The ARPA-E Methane Pyrolysis Project successfully developed a scalable technology for hydrogen production with low-CO x emission through methane pyrolysis, co-producing high-value carbon nanotubes (CNTs). The project focused on optimizing reactor design, enhancing catalyst performance, and assessing techno-economic feasibility to create a commercially viable and environmentally sustainable process. The fluidized bed reactor achieved over 90% methane (CH 4 ) conversion by using a 5% CO 2 co-feed, which stabilizes carbon yields and minimizes catalyst deactivation. This setup allowed for continuous operation across ten cycles, each consisting of a 14-minute pyrolysis phase followed by a 10-minute dislodging phase to remove a fraction of the accumulated carbon, resulting in stable performance and high-quality CNT production. In parallel, monolith reactors coated with Fe demonstrated a sustained methane conversion of 73% while producing CNTs with high crystallinity. Although promising for continuous operation, monolith reactors face challenges in coating durability and scalability, highlighting areas for further optimization in commercial applications. Catalyst formulation played a key role in enhancing process efficiency. The core catalyst used was 5%Fe/Al 2 O 3 (wt%), optimized through wet impregnation, which improved CNT morphology, yielding longer and more uniform CNTs. The catalyst's performance was further enhanced by adding promoters: 2.5 wt% Ni increased methane conversion close to the thermodynamic limit, while 2.5 wt% Mn improved CNT alignment and crystallinity, and 1.5 wt% NaCl boosted CNT morphology but slightly lowered methane conversion. These adjustments allowed the reactor to maintain high methane conversion while producing high-quality CNTs, enabling stable performance over multiple cycles. To address carbon buildup and ensure uninterrupted operation, a pneumatic conveying tube was implemented for effective carbon dislodging in the fluidized bed configuration. CO 2 and H 2 O co-feeds were also introduced to enhance carbon removal, with CO 2 boosting CNT yield by approximately 15%. This setup enabled stable reactor operation across multiple cycles, preventing clogging and minimizing catalyst wear, making the process suitable for industrial scaling. Techno-economic analysis (TEA) projected hydrogen production costs between $\$$1.00 and $\$$1.64 per kilogram, with CNT values assumed at $\$$375/ton and $\$$100/ton. The life cycle assessment showed that CO 2 emissions could be as low as 0.64 kg CO 2 e/kg H 2 at 95% methane conversion assuming an electricity input of 50 kg CO 2 e/MWh. Even at 50% methane conversion, emissions remained below 1 kg CO 2 e/kg H 2 , demonstrating the process's low-emission potential and making it a viable alternative to traditional steam methane reforming. Overall, the results from this project demonstrate the feasibility of a pyrolysis process where carbon is continuously removed from the catalyst surface and hydrogen is continuously produced until a catalyst regeneration step is required to fully clean the catalyst surface and renew catalyst performance. Major open challenges are related to avoiding the loss of catalyst material in the dislodged carbon during fluidized bed conditions, since our best result demonstrated a carbon purity of ~70 wt. % (rest being iron and alumina). A monolith reactor was used to favor dislodgement of carbon compared to fluidized bed conditions but our results do not demonstrate an advantage of the monolith configuration. Catalyst performance was similar to fluidized bed conditions with slower deactivation rates overall, but we could not observe carbon dislodging in any of the tens of experiments that were run at Stanford. Our results show that the most relevant areas of improvement are related to the fundamental understanding of the iron-carbon interface for dislodging, and the development of catalyst that can produce CNTs via a base-growth mechanism such that catalyst is not lost in the dislodgement steps. The final report documents all findings and methodologies in detail, providing a valuable resource for the scientific community. By building on these results, researchers can further advance methane pyrolysis technology, moving toward a more sustainable, scalable pathway for hydrogen production. This work lays the foundation for future research and commercial efforts to reduce emissions in hydrogen production while generating valuable carbon products.

08 HYDROGEN↗

Regal Beloit Final Technical Report

The original project proposal submitted from NovaTorque Inc (NovaTorque) in 2016 was to improve the existing motor with 95% efficiency by reducing the losses by 21% to achieve 96%. A few months after the proposal was submitted, NovaTorque lost funding and went out of business. The assets of NovaTorque were then acquired by Regal Beloit Corporation (“Regal Beloit” or “Regal”). When the NovaTorque proposal was selected, the project was transferred to Regal Beloit. Once we had production samples from the new Regal production line, they were tested at the Regal Beloit test lab in Wausau, WI. The original NovaTorque motor had an efficiency of 95%, but when the technology was transferred to Regal Beloit, there were multiple manufacturing improvements made, even though the basic electromagnetic design did not change. The test results in Wausau showed that the motors made at the Regal Beloit plant had an efficiency of 96%. Since the goal of the project was to reduce the losses by 21%, a new efficiency target of 96.8% became the project objective. In the first budget period, motors were tested to get the baseline performance. We then used FEA modeling with ANSYS Maxwell to model the existing motor to get correlation between the FEA simulations and the actual test results. Once the model was validated, we evaluated some changes that could be made to the stator to reduce the losses and improve efficiency without changing the rotor or stator housing, keeping the modifications easy to implement. The changes were primarily in the area of making the stator axially shorter and adding Soft Magnetic Composite (SMC) tooth tips. In the second budget period, we proceeded to design and build the new stator that was identified above and identified additional improvements in the process that included a stator machining modification and the use of rectangular wire. When we actually built the motor, the choice of rectangular wire turned out to be a problem. The wire was made by squishing round wire to get the rectangular shape, which caused work hardening, making the wire too stiff to make the desired coils. We shifted to annealed square wire which was better, but we still could not maintain the proper coil envelope. The result was that we had reduced cross section area for stator laminations. We also had to have a radial offset resulting in a radial misalignment between the stator and rotor because of the oversized coils. After the motor was completed, it was shipped to Texas A&M University for testing. With the loss of flux from these issues, the measured motor efficiency was only 96.3%. The primary focus of this motor was to make sure our FEA simulation model predicted the measured losses and overall efficiency, this we moved on to the FEA simulation. The FEA simulations of the motor “as built” with misalignments had good correlation with the test results, so the next step was to use that model to optimize the design of the motor for a final build. This time we considered changes to the stator and rotor and also minor changes to the housing diameter. In the third budget period, we did the detailed design and construction of the final prototypes. The final prototypes had a slight increase in the stator diameter to fit in a standard Regal Beloit housing. We shortened the stator and use more layers of wire in the coils. We also increased the cone angle of the rotor and stator from the original 110 degrees to 130 degrees to get some additional efficiency and optimized the stator cross section. The predicted efficiency from the FEA simulations was 96.9%. When completed, the motors were tested. We were a little short of reaching our target efficiency goal of 96.8%. We were only able to get to 96.7% efficiency. While it may be possible with additional iterations in designs and future builds to gain that additional 0.1%, we believe that we are close to the best we can achieve from a practical viewpoint, and additional iterations would be more work than the potential gains would be worth. No other motor in this class can even reach the 96% that we started with.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Measurement of Sulfur Oxidation Products and Their Role in Homogeneous Nucleation

An improved version of a transverse ion source was developed which uses selected ion chemical ionization mass spectrometry techniques inside of a particle nucleation flow tube. These new techniques are very unique, in that the chemical ionization is done inside of the flow tube rather than by having to remove the compounds and clusters of interest which are lost on first contact,with any surfaces. The transverse source is also unique because it allows the ion reaction time to be varied over more than an order of magnitude, which in turn makes possible the separation of ion induced cluster growth from the charging of preexisting molecular clusters. As a result of combining these unique capabilities, the first ever measurements of prenucleation molecular clusters were performed. These clusters are the intermediate stage of growth in the gas-to-particle conversion process. This new technique provides a means of observing clusters containing 2, 3, 4, ... and up to about 8 sulfuric acid molecules, where the critical cluster size under these measurement conditions was about 4 or 5. Thus, the nucleation process can now be directly observed and even growth beyond the critical cluster size can be investigated. The details of this investigation are discussed in a recently submitted paper, which is included as Appendix A. Measurements of the diffusion coefficient of sulfuric acid and sulfuric acid clustered with a water molecule have also been performed. The measurements are also discussed in more detail in another recently submitted paper which is included as Appendix B. The empirical results discussed in both of these papers provide a critical test of present nucleation theories. They also provide new hope for resolving many of the huge discrepancies between field observation and model prediction of particle nucleation. The second part of the research conducted under this project was directed towards the development of new chemical ionization techniques for measuring sulfur oxidation products.

Eisele, F. L.↗

TEAMER: Water Tunnel Data from Testing the Pterofin Skimmer Concept

Pterofin's Skimmer concept relies on a flapping and pitching hydrofoil to extract hydrokinetic energy from water flows. The concept aims to utilize unsteady fluid dynamics phenomena (added mass, shed vorticity, and unsteady boundary layer development) to achieve higher lift coefficients, enabling increased power density of the hydrokinetic device and a fundamental shift in the rpm/torque scaling of the power take off compared with turbines. The Applied Research Laboratory at Penn State, in collaboration with Pterofin, designed and built a proof-of-concept flapping/pitching mechanism which was subsequently tested in ARL's 12-inch water tunnel facility. The mechanical power supplied to or extracted from the mechanism was measured for a range of hydrofoils provided by Pterofin over operating conditions including reduced frequency, Reynolds number, and the ratio between pitching and flapping amplitudes. The power lost to friction in the mechanism was removed from the net power measurement by means of a bare hub tare, with the resultant hydrodynamic power being used to calculate a mechanism-independent and non-dimensional power coefficient. The product of this effort is a dataset describing the power coefficient of a hydrofoil having simultaneous pitching and flapping motions, both of which are approximately sinusoidal. Power coefficients were collected for a range of primary design variables including: - Reduced frequency: 0.01 to 0.95 - Pitching/flapping peak angle ratio: 1.5 to 3.0 - Chord-based Reynolds number: 60,000 to 560,000 Secondary design variables relating to the hydrofoil geometry were explored including: - Aspect ratio - Planform shape - Section thickness distribution - Hydrofoil position relative to the pitching axis - Hydrofoil sweep angle relative to the pitching axis Measured data are provided in mean and time series formats. MATLAB scripts are provided which can be used to generate figures of time-averaged and phase-averaged hydrodynamic power coefficients calculated from the measured data. A complete description of the experiment and data reduction can be found in the Post Access Report for the Pterofin Skimmer test effort which will be available on the TEAMER website. This work was supported by the Pacific Energy Ocean Trust via a TEAMER award.

16 TIDAL AND WAVE POWER↗

Criteria for identification of ablation debris from primitive meteoric bodies

Samples of ablated materials are analyzed to determine properties expected to be characteristic of particulates generated by the ablation of primitive meteoric bodies. Analyses of carbonaceous-chondrite fusion crusts and samples artificially ablated in the laboratory indicate that most meteor-ablation debris should consist of assemblages of silicate minerals, principally olivine, and micron-sized magnetic grains. It is expected that ablation debris of at least 10 microns should have abundances of Fe, Mg, Si, Ca, and Ni similar to those found in chondritic meteorites. Volatile species such as S, H2O, and Cl are lost during ablation and normally should not be found in ablated material. The major findings of this study are supported by analysis of spherules collected in the atmosphere which are thought, on separate grounds, to be genuine meteor-ablation products. The majority of meteoric bodies probably have cometary origins, and it is hoped that the ability to collect and identify meteor-ablation debris reliably will provide an opportunity to do laboratory analysis of cometary matter.-

Brownlee, D. E.↗

Chemical differentiation of a convecting planetary interior: Consequences for a one-plate planet such as Venus

Chemically depleted mantle forming a buoyant, refractory layer at the top of the mantle can have important implications for the evolution of the interior and surface. On Venus, the large apparent depths of compensation for surface topographic features might be explained if surface topography were supported by variations in the thickness of a 100-200 km thick chemically buoyant mantle layer or by partial melting in the mantle at the base of such a layer. Long volcanic flows seen on the surface may be explained by deep melting that generates low-viscosity MgO-rich magmas. The presence of a shallow refractory mantle layer may also explain the lack of volcanism associated with rifting. As the depleted layer thickens and cools, it becomes denser than the convecting interior and the portion of it that is hot enough to flow can mix with the convecting mantle. Time dependence of the thickness of a depleted layer may create episodic resurfacing events as needed to explain the observed distribution of impact craters on the venusian surface. We consider a planetary structure consisting of a crust, depleted mantle layer, and a thermally and chemically well-mixed convecting mantle. The thermal evolution of the convecting spherical planetary interior is calculated using energy conservation: the time rate of change of thermal energy in the interior is equated to the difference in the rate of radioactive heat production and the rate of heat transfer across the thermal boundary layer. Heat transfer across the thermal boundary layer is parameterized using a standard Nusselt number-Rayleigh number relationship. The radioactive heat production decreases with time corresponding to decay times for the U, Th, and K. The planetary interior cools by the advection of hot mantle at temperature T interior into the thermal boundary layer where it cools conductively. The crust and depleted mantle layers do not convect in our model so that a linear conductive equilibrium temperature distribution is assumed. The rate of melt production is calculated as the product of the volume flux of mantle into the thermal boundary layer and the degree of melting that this mantle undergoes. The volume flux of mantle into the thermal boundary layer is simply the heat flux divided by amount of heat lost in cooling mantle to the average temperature in the thermal boundary layer. The degree of melting is calculated as the temperature difference above the solidus, divided by the latent heat of melting. A maximum degree of melting is prescribed corresponding to the maximum amount of basaltic melt that the mantle can initially generate. As the crust thickens, the pressure at the base of the crust becomes high enough and the temperature remains low enough for basalt to transform to dense eclogite.

Parmentier, E. M.↗

Calculation of energy deposition distributions for simple geometries

When high-energy charged particles pass through a thin detector, the ionization energy loss in that detector is subject to fluctuations or straggling which must be considered in interpreting the data. Under many conditions, which depend upon the charge and energy of the incident particle and the detector geometry, the ionization energy lost by the particle is significantly different from the energy deposited in the detector. This problem divides naturally into a calculation of the energy loss that results in excitation and low-energy secondary electrons which do not travel far from their production points, and a calculation of energy loss that results in high-energy secondary electrons which can escape from the detector. The first calculation is performed using a modification of the Vavilov energy loss distribution. A cutoff energy is introduced above which all electrons are ignored and energy transferred to low energy particles is assumed to be equivalent to the energy deposited by them. For the second calculation, the trajectory of the primary particle is considered as a source of secondary high-energy electrons. The electrons from this source are transported using Monte Carlo techniques and multiple scattering theory, and the energy deposited by them in the detector is calculated. The results of the two calculations are then combined to predict the energy deposition distribution. The results of these calculations are used to predict the charge resolution of parallel-plate pulse ionization chambers that are being designed to measure the charge spectrum of heavy nuclei in the galactic cosmic-ray flux.

Watts, J. W., Jr.↗

Functional patterns in an annual grassland during an AVIRIS overflight

This study relates Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) imagery to ground measurements of vegetation distribution, physiology, and productivity at Stanford University's Jasper Ridge Biological Preserve. Primary efforts focused on a 9-ha region of annual grassland where we completed a detailed ground-based study in conjunction with a 15 May 1991 AVIRIS overflight. Spectral mixture analysis and the normalized difference vegetation index (NDVI) calculated from AVIRIS data were used to evaluate spatial patterns of vegetation type, productivity, and potential physiological activity. Concurrent ground sampling revealed a high degree of correlation between NDVI and estimates of canopy chemistry, structure, productivity, and CO2 flux, supporting the use of imaging spectrometry to estimate spatial and temporal trends in vegetation physiology and productivity in this relatively simple grassland ecosystem. Geostatistical analyses of both ground and AVIRIS data supported the conclusion that the AVIRIS pixel size was suitable for describing the influence of major landscape features in this grassland and that spatial detail would be lost at slightly larger pixel sizes typical of other imaging spectrometers.

Gamon, John A.↗