Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “long pulse operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Continuous and Time-Domain Coherent Signal Conversion between Optical and Microwave Frequencies

A quantum network consisting of computational nodes connected by high-fidelity communication channels could expand information-processing capabilities significantly beyond those of classical networks. Superconducting qubits hold promise for scalable and high-fidelity quantum computation at microwave frequencies but must operate in an isolated cryogenic environment, obviating the potential for practical long-range communication. Quantum communication has, however, been demonstrated with optical photons. A fast efficient quantum-coherent interface between superconducting qubits and optical photons would provide a key resource for a large-scale quantum network or distributed quantum computer. Here, we describe the design and experimental operation of a device incorporating a silicon optomechanical nanobeam combined with an aluminum-nitride-based electromechanical transducer. We experimentally demonstrate classical continuous-wave operation of this device at room temperature with external conversion efficiencies of (2.5 +/- 0.4) x 10 -5 (microwave to optical) and (3.8 +/- 0.4) x 10 -5 (optical to microwave), corresponding to internal efficiencies of 2.4% and 3.7%, respectively. Finally, this device also has a larger bandwidth than previous efficient microwave-optical transducers, allowing us to operate in the time domain with 20-ns pulses.

74 ATOMIC AND MOLECULAR PHYSICS↗

Results from the DUNE ND-LAr 2x2 Demonstrator Run 2

The Deep Underground Neutrino Experiment (DUNE) is a cutting-edge, long-baseline experiment under construction in the United States, based on large liquid-argon time projection chambers (LArTPCs). The DUNE Near Detector LArTPC (ND-LAr) will employ a novel modular architecture using a pixelated LArPix charge readout. To validate this design and characterize detector response, the 2×2 demonstrator—an array of eight optically isolated LArTPC modules—was deployed at Fermilab in 2024. During winter 2025, the 2x2 demonstrator was operated for a second data-taking campaign (Run 2) with the aim of studying the low-energy response of the detector. Run 2 focused on calibration and response studies using a suite of deployed radioactive sources. Gamma sources (²²Na, ⁶⁰Co, and ⁸⁸Y) were used to probe module-to-module performance variations, energy resolution, and calibrations. Neutron sources (AmBe and a pulsed neutron generator) enabled studies of neutron interactions in liquid argon, including inelastic scatters and neutron capture signals, relevant for low-energy backgrounds and detector modeling. In addition, the detector was doped with ²²⁰Rn, providing Bi–Po coincidence signals that allow precise calibration of the charge and scintillation response. This poster will present results from these calibration campaigns. These studies provide critical validation of the ND-LAr modular LArTPC concept and inform calibration and reconstruction strategies for the full DUNE near detector.

Mora-Lepin, Luis [Florida State U.] (ORCID:0000000↗

Disruption Prediction and Avoidance in High Beta Long Pulse KSTAR Plasmas

DoE Grant DE-SC0016409 (Disruption Prediction and Avoidance in High Beta Long Pulse KSTAR Plasmas) supported a collaboration among Columbia University, the Princeton Plasma Physics Laboratory (PPPL), and the Plasma Science and Fusion Center (PSFC) at MIT to conduct research on the KSTAR tokamak at the National Fusion Research Institute (NFRI) in Korea to improve predictive capability for disruptions in tokamaks. This initiative included upgrades to kinetic diagnostics at KSTAR whose measurements form the basis for the disruption prediction models. The major thrust of the PPPL and PSFC work was implementing a capability at KSTAR to allow partially-polarized background light seen by the KSTAR Motional Stark Effect (MSE) diagnostic to be compensated by ‘wavelength interpolation’ rather than the traditional ‘beam modulation’ technique. This objective was completed on time and on budget, and the MSE Background Polychromator is currently functioning at KSTAR. Primary responsibility for maintaining and operating the MSE-BP was transferred to Nova Photonics, Inc. in 2019.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of advanced vacuum technologies for extending plasma pulse duration on EAST

Advanced vacuum technologies, including pumping, fueling and wall conditioning, have been successfully developed or upgraded to efficiently control the fuel and impurity particles to extend the plasma pulse duration in the experimental advanced superconducting tokamak (EAST). To improve the particle exhaust rate cryopumps with a 60% increase in pumping speed and ∼2 times increase in saturation capacity have been developed, and molecular pumps with a ∼30% increase in pumping speed have been upgraded. In order to monitor the molecular pump status while avoiding bearing faults and overload accidents, a fault detection system has been built which can offer an early warning to avoid more losses within the fusion device. A series of fueling technologies have been developed including gas injection system, supersonic molecular beam injector, pellet injector (PI), massive gas injector and shattered pellet injector, installed at the midplane and divertor positions at different ports to improve fueling uniformity and efficiency. Meanwhile, routine wall conditioning such as electric and hot N 2 baking, ion cyclotron wall conditioning and glow discharge cleaning have been successfully developed to remove the impurity particles from the inner component and materials. The low Z material wall coating and real-time powder injection during plasma discharge are also designed and applied to further improve particle control capability. Finally, by using these advanced vacuum related technologies, good vacuum (<2 × 10 −6 Pa) and wall conditions are realized, and the fuel and impurity particles can be effectively and stably controlled, which promotes the achievement of the record plasma of ∼1056 s pulse duration with the line-averaged electron density of 1.8 × 10 19 m −3 on EAST. They provide a very important reference for vacuum system design and operation for future fusion devices.

EAST↗

Design and Testing of a Prototype Eddy Current Actuated Valve for the ITER Shattered Pellet Injection System

Reliably mitigating disruptions is essential for ITER to meet its long-term operational research plan without damage to the in-vessel components. Currently, the shattered pellet injection (SPI) technique is the most effective radiator of thermal energy and has been chosen for the baseline disruption mitigation system (DMS) for ITER. The SPI process uses cryogenic temperatures to desublimate material into the barrel of a pipe gun forming a solid cylindrical pellet. Pellets for ITER will initially be hydrogen and hydrogen-neon mixtures. Once formed, pellets are dislodged and accelerated using high-pressure gas (40-60 bar) delivered by a fast-opening valve. The solenoid valves currently used for SPI experiments will not operate in an ITER environment due to the large background magnetic field. An ITER prototype fast-opening valve, called a flyer plate valve (FPV), has been designed and has undergone a wide range of testing. The FPV operates by pulsing current through a pancake coil that is closely coupled with a ``flyer plate.'' The flyer plate is an aluminum plate in which eddy currents are generated creating a repulsive force from the pancake coil. The force generated in the flyer plate rapidly lifts the valve tip off the seat and delivers a pulse of gas to the rear of the pellet, breaking it free from the barrel and accelerating the pellet downstream to its intended target. The design of the valve has been iterated on over the lifetime of this project, as the DMS for ITER shifted from massive gas injection (MGI) to SPI. The most recent design has been tested, and operational ranges have been mapped. The valve must survive 3000+ cycles in an ITER-like magnetic field. The principal functional requirement of this valve is to reliably dislodge and accelerate hydrogen (or H-Ne mixture) pellets into ITER. The valve was mated with an ITER SPI test stand and has been shown to be capable of launching pellets reliably. The valve and power supply design will be discussed in this article, along with the various testing setups used to determine the feasibility of this valve for use on ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technical Performance and Cost Optimization of Unobtrusive Multi-static Serial LiDAR Imager (UMSLI) for Wide-area Surveillance and Identification of Marine Life at Marine Energy Installations

Florida Atlantic University developed an underwater optical monitoring system prototype - Unobtrusive Multi-static Serial LiDAR Imager (UMSLI) - suitable for marine energy full project lifecycle observation (baseline, commissioning, and decommissioning), with an automated real-time classification of marine animals. With precursor 2014 DOE funding (award DE-EE0006787), a prototype UMSLI was demonstrated in a controlled laboratory environment and achieved a TRL 6. This EERE DE-EE0007828 award aimed to both increase the TRL of the UMSLI by improving the technology performance (e.g., increase distance of marine animal target detection capability, add additional species classification capabilities, improve the system performance during the day, etc.) and reduce the cost. The UMSLI presents a novel application of underwater distributed Light Detection And Ranging (LiDAR), an advanced remote sensing method that uses light in the form of laser pulses for an application, this paired with an algorithm provides 360 degrees underwater detection, imaging, and classification of marine life. This solution for underwater monitoring of biota preserves the advantages of traditional optical and acoustic solutions while overcoming many associated disadvantages for marine energy site environmental monitoring, such as difficulties in species detection and classification in low light or night and turbid environments. This new approach is a purposefully designed, reconfigurable adaptation of an existing class 3B laser technology into one UMSLI instrument that can be easily mounted on or around different classes of marine energy equipment, such as devices to capture ocean current energy or wave energy. The system uses relatively low average power, utilizes far-red (> 635nm) laser illumination to be invisible and eye-safe to marine animals, is compact, and cost-effective. The equipment is designed for long-term, maintenance-free operations (i.e., current design is targeting more than 7 days continuous operation), to inherently generate a sparse primary dataset that only includes detected anomalies, and to allow robust real-time automated animal classification and identification with a low data bandwidth requirement. The technology’s overarching goal for application, is a system that can be deployed to collect pre-installation baseline species observations at a proposed marine energy deployment site with minimal post-processing overhead. The envisioned system will also produce high-resolution imagery of marine animals through a wide range of conditions and support automated tracking and notification of the presence of managed animals within established perimeters of marine energy equipment to satisfy deployed marine energy projects’ endangered and threatened species monitoring requirements. Through the current project, we demonstrated the UMSLI prototype in an operational environment and increased the UMSLI’s Technology Readiness Level from 6 to 7. The project resulted in many novel technologies, including: 1) an eye-safe red laser based, low-cost LiDAR system that can detect targets up to 10 meters distance; 2) the GAN-based machine learning underwater LiDAR image enhancement technique (this is the first known application of GAN technique in underwater LiDAR); 3) LiDAR-based real-time automated detection capabilities; and 4) a template matching based automated classification tool. These technologies build a solid foundation for future efforts to develop an extended range electro-optical monitoring system suitable for marine energy deployments. In addition to technology development, a key lesson learned is that addressing regulatory and safety requirements must be front and center in any marine energy monitoring applications.

16 TIDAL AND WAVE POWER↗

Kinetic Inductance Phonon-Mediated Detectors for Dark Matter: R&D at NEXUS

Superconducting thin films have long been used as phonon sensors, particularly in the field of dark matter (DM) direct detection, due to the meV-scale Cooper-pair binding energy. A novel class of these detectors based on microwave kinetic inductance detectors, dubbed Kinetic Inductance Phonon-Mediated Detectors (KIPMDs), offers an attractive architecture for microcalorimeters to probe DM down to the fermionic thermal relic mass limit of a few keV. Such a device featuring an aluminum resonator patterned onto a silicon substrate was operated at the NEXUS low-background facility at Fermilab for characterization and evaluation of its efficacy for a dark matter search. With this device we have demonstrated a resolution on the energy absorbed by the superconductor of 2.5 eV, a factor of two better than current state-of-the-art. In this talk, I will present our measurement of the energy resolution and phonon collection efficiency performed by exposing the bare substrate to a pulsed source of 470 nm photons. I will also discuss the path forward to obtaining in these devices the sub-eV resolution required to test the “Freeze-in” class of DM models. Finally, I will review other complementary efforts in our group to develop a superconducting qubit-based low-threshold detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a Low-Temperature Plasma (LTP) Ambient Ionization Source Using Temporally Resolved Monochromatic Imaging Spectrometry

The low-temperature plasma (LTP) probe is a common plasma-based source used for ambient desorption–ionization mass spectrometry (MS). While the LTP probe has been characterized in detail with MS, relatively few studies have used optical spectroscopy. In this paper, two-dimensional (2D) imaging at selected wavelengths is used to visualize important species in the LTP plasma jet. First, 2D steady-state images of the LTP plume for N 2 + (391.2 nm), He I (706.5 nm), and N 2 (337.1 nm) emissions were recorded under selected plasma conditions. Second, time-resolved 2D emission maps of radiative species in the LTP plasma jet were recorded through the use of a 200 ns detection gate and varying gate delays with respect to the LTP trigger pulse. Emission from He I, N 2 + , and N 2 in the plasma jet region was found to show a transient behavior (often referred to as plasma bullets) lasting only a few microseconds. The N 2 + and He I maps were highly correlated in spatial and temporal structure. Further, emission from N 2 showed two maxima in time, one before and one after the maximum emission for N 2 + and He I, due to an initial electronic excitation wave and ion–electron recombination, respectively. Third, the interaction of the LTP probe with a sample substrate and an electrically grounded metallic needle was studied. Emission from a fluorophore on the sample substrate showed an initial photon-induced excitation from plasma-generated photons followed by electronic excitation by other plasma species. The presence of a grounded needle near the plasma jet significantly extended the plasma jet lifetime and also generated a long-lived corona discharge on the needle. The effect of LTP operating parameters on emission spectra was correlated with mass-spectral results including reagent-ion signals. Lastly, five movies provide a side-by-side comparison of the temporal behavior of emitting species and insights into the interactions of the emission clouds with a sample surface as well as an external needle. Temporally and spatially resolved imaging provided insights into important processes in the LTP plasma jet, which will help improve analyte ion sampling in LTP–MS.

Chan, George C. -Y.↗

HSQC spectra of lignin isolated from poplar stems

Here we present a curated dataset of two-dimensional heteronuclear single quantum coherence (HSQC) nuclear magnetic resonance (NMR) spectra of lignin isolated from stems of genetically engineered poplar through auxin signaling gene modification. The plants were grown in greenhouse with temperatures between 21 and 23 °C. Plants were harvested and the aboveground stems were cut off an approximately five-inch-long segment from the bottom end of the plant stem, debarked and air-dried for three weeks. The dried stem samples were Wiley milled (mesh size 20), Soxhlet-extracted with toluene/ethanol for 24 h to remove extractives. The extracted biomass was ball-milled in a Retsch PM100 planetary ball mill using a porcelain jar with ceramic balls at 600 rpm for 2 h (in 5 min on and 5 min off cycles to avoid excessive sample heating). The ball-milled materials were then subjected to enzymatic hydrolysis for 48 h followed by centrifugation and washing with deionized water. The solid residue was freeze-dried to recover the lignin. The dry stem lignin samples were dissolved in deuterated dimethyl sulfoxide (d6) and transferred into a 5 mm tube. 13C–1H HSQC experiments were performed in a Bruker Avance III HD 500 MHz NMR spectrometer operating at a frequency of 125.12 MHz for the 13C nucleus using a standard Bruker pulse sequence on a Prodigy platform cryoprobe. The NMR spectra were acquired under the following acquisition conditions: 230 ppm spectral width in F1 (13C) dimension with 256 data points and 12 ppm spectral width in F2 (1H) dimension with 2048 data points, a 90° pulse, a one bond C–H coupling constant of 145 Hz, a 1.0 s pulse delay, and 64 scans. Spectra were processed using the Bruker TopSpin 3.6 software. Additional meta data is embedded in the raw spectra figures.

HSQC, lignin, poplar, stems, CBI↗

Online and noninvasive monitoring of battery health at negative-half cell in all-vanadium redox flow batteries using ultrasound

Hydrogen evolution is one of the major side reactions that is detrimental to the health of all-vanadium redox flow batteries, especially for long-term cycling. Effective, low-cost, and accurate online prediction and detection methods for hydrogen generation are not yet available. In this work, we designed an online, noninvasive ultrasonic probing approach for monitoring the state of charge (SoC), predicting the hydrogen generation, and detecting hydrogen gas bubbles in anolyte solutions. The technique employs a pulse-echo method to measure the sound speed and the acoustic attenuation coefficient of the anolyte solution. Through static offline experiments and online in operando experiments, we have demonstrated that when hydrogen gas is generated in anolyte solutions, large variations are observed in both sound speed and acoustic attenuation coefficient measurements. We found that the variations of acoustic attenuation coefficient are highly correlated (correlation coefficients >0.9) with the gas flow rate. In conclusion, the designed acoustic method can monitor the SoC of anolyte, predict the hydrogen generation, and detect the presence of gas bubbles in an anolyte solution and, thus, provide information about the state of health for operation and management of flow battery systems.

25 ENERGY STORAGE↗

Survey of tungsten gross erosion from main plasma facing components in WEST during a L-mode high fluence campaign

An initial high fluence campaign was performed in WEST, in 2023, on the newly installed actively cooled tungsten divertor composed of ITER-grade monoblocks. The campaign consisted in the repetition of a 60 s long Deuterium L-mode pulse in attached divertor conditions, cumulating over 10000s of plasma exposure. A maximum deuterium fluence of approximately 5⋅1⁢026 m−2 was reached in the outer strike point region, representative of a few high performance ITER pulses. Gross tungsten erosion inferred from visible spectroscopy shows that the most eroded plasma facing component is the inner divertor target with rates ten times larger than on the outer divertor target. The outer midplane tungsten bumpers, located a few centimeters from the plasma, show gross erosion rates two times lower than at the outer divertor. We conclude that the outer midplane bumpers have a negligible contribution to the long range tungsten migration and deposition onto the lower divertor. The cumulated gross erosion rate on the inner divertor translates in an effective gross erosion thickness of about 20μ⁢m, while it is about 2μ⁢m for the outer divertor. Strikingly, these orderings coincide with the thickness of deposits found locally on the divertor: the exposed surfaces of high field side monoblocks are covered with several tens of μ⁢m tungsten deposits, while on the lower field side, few μ⁢m thin tungsten deposits are only found on the magnetically shadowed parts of monoblocks. The strong impact of those deposits on WEST operation, namely perturbation of surface temperature measurement with infra-red thermography, and the emission of flakes causing radiative perturbation of the confined plasma, calls for anticipating similar issues in ITER. In particular, the start of research operation shall consider the definition of a divertor erosion budget in order to anticipate the formation of deleterious deposits.

Fedorczak, N.↗

Suppression of toroidal Alfvén eigenmodes by the electron cyclotron current drive in KSTAR plasmas

Advanced operation scenarios such as high poloidal beta ( β P ) or high q min are promising concepts to achieve the steady-state high-performance fusion plasmas. However, those scenarios are prone to substantial Alfvénic activity, causing fast-ion transport and losses. Recent experiments with the advanced operation scenario on KSTAR tokamak have shown that the electron cyclotron current drive (ECCD) is able to mitigate and suppress the beam-ion driven toroidal Alfvén eigenmodes (TAEs) for over several tens of global energy confinement time. Co-current directional intermediate off-axis ECCD lowers the central safety factor slightly and tilts the central q -profile shape so that the continuum damping in the core region increases. Besides, the rise of central plasma pressure and increased thermal-ion Landau damping contribute to TAE stabilization. While the TAEs are suppressed, neutron emission rate and total stored energy increase by approximately 45% and 25%, respectively. Fast-ion transport estimated by TRANSP calculations approaches the classical level during the TAE suppression period. Substantial reduction in fast-ion loss and neutron deficit is also observed. Subsequently, enhancement of fast-ion confinement by suppressing the TAEs leads to an increase of non-inductive current fraction and will benefit the sustainment of the long-pulse high-performance discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modular chip-integrated photonic control of artificial atoms in diamond waveguides

A central goal in creating long-distance quantum networks and distributed quantum computing is the development of interconnected and individually controlled qubit nodes. Atom-like emitters in diamond have emerged as a leading system for optically networked quantum memories, motivating the development of visible-spectrum, multi-channel photonic integrated circuit (PIC) systems for scalable atom control. However, it has remained an open challenge to realize optical programmability with a qubit layer that can achieve high optical detection probability over many optical channels. Here, we address this problem by introducing a modular architecture of piezoelectrically actuated atom-control PICs (APICs) and artificial atoms embedded in diamond nanostructures designed for high-efficiency free-space collection. The high-speed four-channel APIC is based on a splitting tree mesh with triple-phase shifter Mach–Zehnder interferometers. This design simultaneously achieves optically broadband operation at visible wavelengths, high-fidelity switching (>40dB) at low voltages, submicrosecond modulation timescales (>30MHz), and minimal channel-to-channel crosstalk for repeatable optical pulse carving. Via a reconfigurable free-space interconnect, we use the APIC to address single silicon vacancy color centers in individual diamond waveguides with inverse tapered couplers, achieving efficient single photon detection probabilities (∼15%) and second-order autocorrelation measurements g (2) (0)<0.14 for all channels. The modularity of this distributed APIC–quantum memory system simplifies the quantum control problem, potentially enabling further scaling to thousands of channels.

47 OTHER INSTRUMENTATION↗

A phenomenological rate of injection model for predicting fuel injection with application to mixture formation in light-duty diesel engines

Fuel injection rate laws are one of the most important pieces of information needed when modeling engine combustion with computational fluid dynamics. In this study, a simple phenomenological model of a common-rail injector was developed and calibrated for the Bosch CRI2.2 platform. The model requires three tunable parameter fits, making it relatively easy to calibrate and suitable for injector modeling when high-fidelity information about the internal injector’s geometry and electrical circuit details are not available. Each injection pulse is modeled as a sequence of up to four stages: an injection needle mechanical opening transient, a full-lift viscous flow inertial transient, a Bernoulli steady-state stage, and a needle descent transient. Parameters for each stage are obtained as polynomial fits from measured injection rate properties. The model enforces total injected mass, and the intermediate stages are only introduced if the injection pulse duration is long enough. Experimental rates of injection from two separate campaigns on the same injector were used to calibrate the model. The model was first validated against measured injection rate laws featuring pilot injections, short partially premixed combustion pulses, and conventional diesel combustion injection strategies. Then, it was employed as an input to engine computational fluid dynamics simulations, which were run to simulate experiments of mixture formation in an optically accessible light-duty diesel engine. It was found that, though simple, this model is capable of predicting both pilot and main injection pulse mass flow rates well: the simulations yielded accurate predictions of in-cylinder equivalence ratio distributions from injection strategies for both partially premixed combustion and pilot injections. Also, once calibrated, the model produced appropriate results for a wide range of injected mass and rail pressure values. Finally, it was observed that usage of such a relatively simple model can be a good choice when high-fidelity injection rate input and highly detailed information of the injector’s geometry and operation are not available, particularly as noticeable discrepancies can be present also among different experimental campaigns on similar hardware.

42 ENGINEERING↗

Tantalum Experiments in Fully-Reflected Water-Moderated Triangular-Pitched U(6.90)O 2 Fuel Rod Lattices (1.02 cm Pitch)

The United States (US) Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories (SNL). The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5 % 235 U. The 7uPCX assembly is a water moderated and — reflected array of aluminum-clad U(6.90 %)O 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMP-THERM 096, LEU- COMP-THERM-097, LEU-COMP-THERM-101, LEU-COMP-THERM-102, and LEU-COMP-THERM-111. Applied interests in neutron-absorbing elements at epithermal and intermediate neutron energy ranges at DOE’s Hanford Site and Savannah River Site were identified through DOE Office of Environmental Management (EM) workshops and needs surveys performed in conjunction with the National Nuclear Security Administration/Nuclear Criticality Safety Program. In response, a team lead by Oak Ridge National Laboratory (ORNL) performed a study evaluating the use of 7uPCX for testing the epithermal cross sections of materials at SNL. This marked the inception of the set of experiments described here. The purpose of these experiments was to measure the effects of tantalum in nearly-critical systems. The tantalum was introduced into the fuel arrays as experiment rods within a central test region. The central test region was designed to target the epithermal neutron energy range by providing a dry cylindrical cavity constructed of aluminum and lined with 0.04 in (0.1016 cm) thick cadmium sheet. The central test region has an outer diameter of 3.75 in (9.525 cm) length of 31 in (78.74 cm) and can hold 85 tantalum rods nominally 0.25 in (0.635 cm) outside diameter and 31.25 in (79.375 cm) long. The critical experiments were done using a set of triangular-pitched grid plates fabricated for these experiments. The grid plate set accommodated a fuel array of a total of 2016 fuel rod positions on a pitch of 0.4 in (1.016 cm) in a series of 21 hexagonal rings positioned around the central test region. The fuel used in these experiments was fabricated using unirradiated 6.90 % enriched UO 2 fuel pellets from fuel elements designed to be used in the internal nuclear superheater section of the Pathfinder boiling water reactor operated in South Dakota by the Northern States Power Company in the 1960s. The fuel elements were obtained from The Pennsylvania State University where they had been stored for many years. The fuel pellets in those fuel elements were removed from the original Incoloy cladding and reclad in 3003 aluminum tubes and end caps for use in the experiments reported here. The eight cases in this experiment series were performed in 2024 in the Sandia Critical Experiments (SCX) at the Sandia Pulsed Reactor Facility by varying the number of fuel rods in the critical assembly. The personnel involved in conducting these experiments included David Ames, Elijah Lutz, Beth Hanson, Patrick Ward, Jason Soares, and Augie Chapa from SNL, as well as Mathieu Dupont and B.J. Marshall from ORNL. Case 1 had no tantalum experiment rods. Case 2 had seven tantalum rods in the center of the central test region. Case 3 had 18 tantalum rods in the third hexagonal ring of the central test region. Case 4 had 19 tantalum rods in the center of the central test region. Case 5 had 30 tantalum rods in the outer most positions of the central test region. Case 6 had 37 tantalum rods in the center of the central test region. Case 7 had 61 tantalum rods in the center of the central test region. Case 8 had 85 tantalum rods filling all positions in the central test region. All eight critical experiments are judged to be acceptable as benchmark experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Atypical phase-change alloy Ga 2 Te 3 : atomic structure, incipient nanotectonic nuclei, and multilevel writing

Emerging brain-inspired computing, including artificial optical synapses, photonic tensor cores, neuromorphic networks, etc., needs phase-change materials (PCMs) of the next generation with lower energy consumption and a wider temperature range for reliable long-term operation. Gallium tellurides with higher melting and crystallization temperatures appear to be promising candidates and enable achieving the necessary requirements. Here, using high energy X-ray diffraction and Raman spectroscopy supported by first-principles simulations, we show that vitreous g-Ga 2 Te 3 films essentially have a tetrahedral local structure and sp 3 hybridization, similar to those in the stable fcc Ga 2 Te 3 polymorph and in contrast to a vast majority of typical PCMs. Nevertheless, optical pump–probe laser experiments revealed high-contrast, fast and reversible multilevel SET-RESET transitions raising a question related to the phase change mechanism. A recently observed nanotectonic compression in bulk glassy Ga–Te alloys seems to be responsible for the PCM performance. Incipient nanotectonic nuclei, reminiscent of monoclinic high-pressure HP-Te II and rhombohedral HP-Ga 2 Te 3 , are present as minorities (2–4%) in g-Ga 2 Te 3 but are suggested to grow dramatically with increasing temperature while interacting with appropriate laser pulses. This leads to co-crystallization of HP-polymorphs amplified by a high internal local pressure reaching 4–8 GPa. The metallic HP-forms provide an increasing optical and electrical contrast, favorable for reliable PCM operations, and higher energy efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent H - ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced from spallation of liquid Hg by bombardment of short (~1 μs), intense (~35 A) pulses of protons delivered at 60 Hz by a storage ring which is fed by a high-intensity, ~1 GeV H - LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50–60 mA of H - ions with a duty-factor of 6% for maintenance-free runs of several months with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting this success: this report provides an update on some of the ongoing ion source research and development efforts which have been undertaken since the previous Negative Ion Beams and Sources (NIBS) conference in 2020. These include significant improvements to H - beam current by extraction from a larger source outlet aperture and improvements to the electron dumping system which should eliminate the gradual loss of electrode voltage over the course of a run which has occasionally impacted SNS operations. Improvement and simplification of the plasma ignition system for the external antenna ion source, a long-standing problem, was also realized. Lastly, RF coupling efficiency was measured for both the SNS internal and external antenna ion sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HSQC spectra of lignin isolated from poplar roots

Here we present a curated dataset of two-dimensional heteronuclear single quantum coherence (HSQC) nuclear magnetic resonance (NMR) spectra of lignin isolated from roots of a greenhouse grown natural population of an energy crop poplar (Populus trichocarpa). Dormant cuttings of field-grown poplar were grown in 6-liter pots in a peat-based media containing bark, perlite, vermiculite, dolomite lime and a wetting agent in an environmentally controlled greenhouse. Temperatures were between 21 and 23 °C, with supplemental lighting to support a 16-h day length using 1000-watt high-pressure sodium lights in greenhouse. Once established, all plants were cut-back, allowed to regrow and harvested at the same time following an eight-month long growth period. Plants were harvested and the belowground roots were washed off soils, blotted, dried in an oven at 70 °C for 3 days, and Wiley milled (mesh size 20). The roots were Soxhlet-extracted with toluene/ethanol for 24 h to remove extractives. The extracted roots were ball-milled in a Retsch PM100 planetary ball mill using a porcelain jar with ceramic balls at 600 rpm for 2 h (in 5 min on and 5 min off cycles to avoid excessive sample heating). The ball-milled materials were then subjected to enzymatic hydrolysis for 48 h followed by centrifugation and washing with deionized water. The solid residue was extracted twice with 96% (v/v) 1,4-dioxane/water mixture at room temperature overnight. The extracts were combined, rotary evaporated, and freeze-dried to recover lignin. The dry lignin samples were dissolved in deuterated dimethyl sulfoxide (d6) and transferred into a 5 mm tube. 13C–1H HSQC experiments were performed in a Bruker Avance III HD 500 MHz NMR spectrometer operating at a frequency of 125.12 MHz for the 13C nucleus using a standard Bruker pulse sequence on a Prodigy platform cryoprobe. The NMR spectra were acquired under the following acquisition conditions: 220 ppm spectral width in F1 (13C) dimension with 256 data points and 12 ppm spectral width in F2 (1H) dimension with 1024 data points, a 90° pulse, a one bond C–H coupling constant of 145 Hz, a 1.0 s pulse delay, and 64 scans. Spectra were processed using the Bruker TopSpin software. Additional meta data is embedded in the raw spectra figures.

HSQC, lignin, poplar, roots, CBI↗