Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Grid Impact Analysis of Heavy-Duty Electric Vehicle Charging Stations

This paper presents a grid impact analysis of heavy-duty electric vehicle (EV) charging stations. In this work, heavy-duty EVs have battery capacities high enough to provide a range of 250-500 miles on a single charge, such as long-haul trucks. Heavy-duty EVs will require extremely fast charging rates to reduce charging time and will induce very high charging loads (at the multiple-megawatt scale) if several vehicles charge at the same time. Therefore, analysis is needed to understand the impact of charging station loads on the electric power grid and set the baseline for developing mitigation plans and necessary system upgrades. We develop a systematic procedure to analyze the potential impact of the placement of charging stations on the grid. Charging load is modeled using a DC fast-charging station model. A voltage load sensitivity matrix approach is leveraged to investigate the challenges of placing charging stations on the feeder. Given the charging load profiles and suggested charging station locations, time-series simulations are performed on various connection points on the feeder to understand the impact. The analysis is performed on both the IEEE 34-bus system and a realistic feeder from California. Initial mitigation solutions are developed based on insights from this analysis.

47 OTHER INSTRUMENTATION↗

DRDMannTurb: A Python package for scalable, data-driven synthetic turbulence

Synthetic turbulence models (STMs) are used in wind engineering to generate realistic flow fields and are employed as inputs to industrial wind simulations. Examples include prescribing inlet conditions in large eddy simulations that model loads on wind turbines and tall buildings. We are interested in STMs capable of generating fluctuations based on prescribed second-moment statistics since such models can simulate environmental conditions that closely resemble on-site observations. To this end, the widely used Mann model (see Mann, 1994, 1998) is the inspiration for DRDMannTurb. The Mann model is described by three physical parameters: a magnitude parameter influencing the global variance of the wind field and corresponding to the Kolmogorov constant multiplied by the rate of viscous dissipation of the turbulent kinetic energy to the two-thirds, αϵ 2/3 , a turbulence length scale parameter L, and a nondimensional parameter Γ related to the lifetime of the eddies. A number of studies, as well as international standards (e.g., those by the International Electrotechnical Commission (IEC)), include recommended values for these three parameters with the goal of standardizing wind simulations according to observed energy spectra. Yet, having only three parameters, the Mann model faces limitations in accurately representing the diversity of observable spectra. This Python package enables users to extend the Mann model and more accurately fit field measurements through flexible neural network models of the eddy lifetime function. Following Keith et al. (2021), we refer to this class of models as Deep Rapid Distortion (DRD) models. DRDMannTurb also includes a general module implementing an efficient method for synthetic turbulence generation based on a domain decomposition technique. This technique is also described in Keith et al. (2021).

17 WIND ENERGY↗

Recovery Act: Advanced Load Identification and Management for Buildings

In response to the U.S. Department of Energy (DoE)’s goal of achieving market ready, net-zero energy residential and commercial buildings by 2020 and 2025, Eaton partnered with the Department of Energy’s National Renewable Energy Laboratory (NREL) and Georgia Institute of Technology to develop an intelligent load identification and management technology enabled by a novel “smart power strip” to provide critical intelligence and information to improve the capability and functionality of building load analysis and building power management systems. Buildings account for 41% of the energy consumption in the United States, significantly more than either transportation or industrial. Within the building sector, plug loads account for a significant portion of energy consumption. Plug load consumes 15-20% of building energy on average. As building managers implement aggressive energy conservation measures, the proportion of plug load energy can increase to as much as 50% of building energy leaving plug loads as the largest remaining single source of energy consumption. This project focused on addressing plug-in load control and management to further improve building energy efficiency accomplished through effective load identification. The execution of the project falls into the following three major aspects; An intelligent load modeling, identification and prediction technology was developed to automatically determine the type, energy consumption, power quality, operation status and performance status of plug-in loads, using electric waveforms at a power outlet level. This project demonstrated the effectiveness of the developed technology through a large set of plug-in loads measurements and testing; A novel “Smart Power Strip (SPS) / Receptacle” prototype was developed to act as a vehicle to demonstrate the feasibility of load identification technology as a low-cost, embedded solution; and Market environment for plug-in load control and management solutions, in particular, advanced power strips (APSs) was studied. The project evaluated the market potential for Smart Power Strips (SPSs) with load identification and the likely impact of a load identification feature on APS adoption and effectiveness. The project also identified other success factors required for widespread APS adoption and market acceptance. Even though the developed technology is applicable for both residential and commercial buildings, this project is focused on effective plug-in load control and management for commercial buildings, accomplished through effective load identification. The project has completed Smart Receptacle (SR) prototype development with integration of Load ID, Control/Management, WiFi communication, and Web Service. Twenty SR units were built, tested, and demonstrated in the Eaton lab; eight SR units were tested in the National Renewable Energy Lab (NREL) for one-month of field testing. Load ID algorithm testing for extended load sets was conducted within the Eaton facility and at local university campuses. This report is to summarize the major achievements, activities, and outcomes under the execution of the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving operational flexibility of integrated energy system with uncertain renewable generations considering thermal inertia of buildings

Insufficient flexibility in system operation caused by traditional "heat-set" operating modes of combined heat and power (CHP) units in winter heating periods is a key issue that limits renewable energy consumption. In order to reduce the curtailment of renewable energy resources through improving the operational flexibility, a novel optimal scheduling model based on chance-constrained programming (CCP), aiming at minimizing the lowest generation cost, is proposed for a small-scale integrated energy system (IES) with CHP units, thermal power units, renewable generations and representative auxiliary equipments. In this model, due to the uncertainties of renewable generations including wind turbines and photovoltaic units, the probabilistic spinning reserves are supplied in the form of chance-constrained; from the perspective of user experience, a heating load model is built with consideration of heat comfort and inertia in buildings. To solve the model, a solution approach based on sequence operation theory (SOT) is developed, where the original CCP-based scheduling model is tackled into a solvable mixed-integer linear programming (MILP) formulation by converting a chance constraint into its deterministic equivalence class, and thereby is solved via the CPLEX solver. We report the simulation results on the modified IEEE 30-bus system demonstrate that the presented method manages to improve operational flexibility of the IES with uncertain renewable generations by comprehensively leveraging thermal inertia of buildings and different kinds of auxiliary equipments, which provides a fundamental way for promoting renewable energy consumption.

30 DIRECT ENERGY CONVERSION↗

slacgismo/pge-baseline-study

Examining existing PG&E baseline methodologies. Load modeling is a complex task, with factors such as weather, time of year, location, purpose of building, and more. This study’s purpose is to use non-Demand-Response data from customers in order to find the most accurate method of predicting load behavior for Demand-Response days.

Serbetcioglu, Berk↗

Heliostat Consortium: Gap Analysis on State of the Art in Wind Load Design

Wind loads are a major driver of heliostat cost. Standardized methods and tools are needed for a more detailed understanding of the static and dynamic loads of a heliostat design. This will enable cost reduction of wind-dependent heliostats to avoid unnecessarily conservative heliostat designs and increase field efficiency and reliability to reduce the risk of component failures due to high-wind events. Gaps related to wind load include lack of site characterization for wind measurements, insufficient critical load cases for heliostat design, insufficient understanding of turbulence impacts on heliostat tracking error, lack of knowledge on wind load under various heliostat array configurations, and underexplored heliostat field wind-load reduction and operating strategies. Recommended pathway forward is to develop wind load and site characterization guidelines for heliostat design and develop heliostat field wind-load models with optical performance impacts.

aerodynamics↗

Modeling and Energy Analysis of Refrigeration Systems in Supermarkets: A Case Study

Refrigeration systems are the single largest consumer of electricity in supermarkets, accounting for approximately 40–60% of total store electricity use. As supermarkets face increasing pressures to improve efficiency and reduce operational costs, understanding the energy performance of refrigeration systems in supermarkets has become essential. In this paper, we investigate the energy performance and patterns of the refrigeration system using field measurements in one supermarket. The compressor coefficient of performance (COP) averaged 4.5 during nighttime steady-state operation, providing a practical efficiency benchmark. We develop simple physical-based load models for the display cases in the supermarket, where the refrigeration system uses R404A. The results show the display case models achieve a good agreement with measured data, validating its utility for energy estimation during unoccupied hours. Finally, the analysis reveals several challenges of data collection systems for refrigeration systems in the supermarket industry as well.

Chen, Yimin [ORNL] (ORCID:0000000338181655)↗

Phasor-Measurement-Unit-Based Data Analytics Using Digital Twin and PhasorAnalytics Software

A major objective of this project was to apply GE’s commercial machine learning and data analytics toolsets to large-scale, real-world, anonymized Phasor Measurement Unit (PMU) datasets in order to extract signatures, correlated and/or causal factors, and precursor patterns associated with significant power system phenomena. The project had a particular emphasis on extraction of insights relevant to asset health monitoring, real-time load modeling and cybersecurity monitoring. Additionally, the team was directed to undertake a comprehensive data quality analysis for the provided datasets and encouraged to estimate the ‘machine-learning readiness’ of the datasets by documenting any major obstacles to the application of commercial machine learning algorithms. To accomplish the aforementioned objectives, the project team’s work centered around the identification of key event signatures and application of the identified event signatures for event detection and event classification. The industry-validated, semi-supervised machine learning strategy employed for event signature identification involved several major tasks, including data-preprocessing, generation of an overabundance of features, normal data identification, normality modeling, and event signature identification through a methodical, quantitative ranking of features in order of relevance to each studied event type. Throughout the project, data quality issues and mitigation techniques were investigated. In this report, insights are provided regarding the readiness of the provided synchrophasor datasets for application of machine learning and data analytics. The methodologies employed for this technical strategy are summarized in this report. With regards to data preprocessing and feature generation, the provided Training and Test Datasets were ingested into GE’s big data environment. Subsequently, the team applied bad data cleansing and data imputation scripts, event detection scripts, and application programming interfaces (APIs) to the datasets for convenient data access. The project team completed development and validation of dozens of physics-based, statistics-based and transformation-based feature functions used for the extraction of over 60 synchrophasor features. Using a new parallel feature generation technology developed on this project, over 60 features have been rapidly generated for the full two years’ worth of Training and Test Dataset data associated with both the Eastern and Western interconnects. Even accommodating for temporal down-sampling inherent to the feature extraction procedure, this parallel feature generation activity resulted in a massive feature set with a storage requirement approximately equal to that of the raw training dataset itself. With regards to normal data identification and normality modeling, a normality model was built using the feature data extracted from the Training Dataset and iteratively refined subsequent to incremental adjustments and expansions of the Training Dataset feature data. With respect to event characterization and signature identification, an event signature identification pipeline was developed and used in conjunction with the normality model to identify over 15 event signatures for key event categories within the Training Dataset. The identified event signatures were used to characterize hundreds of key events in terms of relative severity, duration, and location of the event. An investigation was undertaken to identify correlated and causal factors involved in transformer events. A separate investigation into temporal trends in ring-down analysis results was undertaken to determine possible associations between system dynamics and various other factors such as loading, season or year. To validate the identified event signatures, additional work was undertaken to develop signature-based anomaly detection and classification tools suitable for convenient application to the synchrophasor datasets. The anomaly detection and classification tools, suitable for online application, were then applied to the entirety of the Eastern Interconnect Training and Test Datasets. Performance of the event detection and classification tools was evaluated upon receipt of the Test Dataset event logs (i.e., the labels for events contained in the Test Dataset), and promising results were obtained despite several challenges (documented herein) associated with application of supervised or semi-supervised machine learning methods to large-scale, anonymized datasets. Finally, the detection and classification tools were used to detect, classify, and characterize thousands of new events not included in the original event logs provided by the DOE within both the Training and Test Datasets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Offshore Wind Farm Performance in Coastal Low-Level Jets Using Coupled Mesoscale-Microscale Large Eddy Simulations

Accurately predicting wind farm reliability under complex offshore atmospheric conditions remains a key challenge, particularly during noncanonical meteorological events such as coastal low-level jets (LLJs). LLJs, characterized by strong nonmonotonic vertical shear and directional veer, depart significantly from the simplified inflow assumptions embedded in conventional design standards, low-fidelity engineering models, and microscale large eddy simulations of the atmospheric boundary layer. In this work, we use the virtual wind farm framework—an exascale, graphics processing unit–accelerated large eddy simulation platform coupled with high-fidelity aeroservoelastic turbine models and advanced mesoscale-microscale coupling via the ExaWind software stack—to investigate turbine responses under realistic LLJ forcing. Simulations are performed over the U.S. North Atlantic offshore domain with the use of meteorological inputs from New York State Energy Research and Development Authority buoy data, focusing on a representative LLJ case impacting the International Energy Agency 15 MW reference turbine. Our results show that LLJs can cause up to 50% power deficits in downstream turbine rows and significantly amplify low-speed shaft and tower loads through nonlinear coupling between complex inflow characteristics and turbine structural dynamics. Two primary mechanisms drive these load amplifications: (1) unique LLJ inflow features—including veer and vertical/lateral shear—and (2) the downstream evolution of the flow under stable thermal stratification, which suppresses turbulence mixing and alters wake recovery. These mechanisms produce streamwise variations in turbine loading not captured by standard hub height–based metrics or existing design load case (DLC) definitions. This study highlights the critical role of rotor-scale flow gradients in driving fatigue and system-level aeroelastic responses, challenging current DLC and control strategies. We advocate the integration of full-flow field, environment-aware wind inputs into load modeling and control algorithms. By leveraging exascale computing to resolve mesoscale-microscale coupling, this work lays the groundwork for next-generation offshore wind turbine design and operation in meteorologically complex marine environments.

17 WIND ENERGY↗

Communication Simulations for Power System Applications

New smart grid technologies and concepts, such as dynamic pricing, demand response, dynamic state estimation, and wide area monitoring, protection, and control, are expected to require considerable communication resources. As the cost of retrofit can be high, future power grids will require the integration of high-speed, secure connections with legacy communication systems, while still providing adequate system control and security. While considerable work has been performed to create co-simulators for the power domain with load models and market operations, limited work has been performed in integrating communications directly into a power domain solver. The simulation of communication and power systems will become more important as the two systems become more inter-related. This paper will discuss ongoing work at Pacific Northwest National Laboratory to create a flexible, high-speed power and communication system co-simulator for smart grid applications. The framework for the software will be described, including architecture considerations for modular, high performance computing and large-scale scalability (serialization, load balancing, partitioning, cross-platform support, etc.). The current simulator supports the ns-3 (telecommunications) and GridLAB-D (distribution systems) simulators. Ongoing and future work will be described, including planned future expansions for a traditional transmission solver. A test case using the co-simulator, utilizing a transactive demand response system created for the Olympic Peninsula and AEP gridSMART demonstrations, requiring two-way communication between distributed and centralized market devices, will be used to demonstrate the value and intended purpose of the co-simulation environment.

co-simulation↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Grid Interactive Micro-Distributed Refrigerated Display Case

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Performance analysis of distributed symmetric sparse matrix vector multiplication algorithm for multi-core architectures

In this article, sparse matrix vector multiply (SpMVM) is an important kernel that frequently arises in high performance computing applications. Due to its low arithmetic intensity, several approaches have been proposed in literature to improve its scalability and efficiency in large scale computations. In this paper, our target systems are high end multi-core architectures and we use messaging passing interface + open multiprocessing hybrid programming model for parallelism. We analyze the performance of recently proposed implementation of the distributed symmetric SpMVM, originally developed for large sparse symmetric matrices arising in ab initio nuclear structure calculations. We also study important features of this implementation and compare with previously reported implementations that do not exploit underlying symmetry. Our SpMVM implementations leverage the hybrid paradigm to efficiently overlap expensive communications with computations. Our main comparison criterion is the "CPU core hours" metric, which is the main measure of resource usage on supercomputers. We analyze the effects of topology-aware mapping heuristic using simplified network load model. Furthermore, we have tested the different SpMVM implementations on two large clusters with 3D Torus and Dragonfly topology. Our results show that the distributed SpMVM implementation that exploits matrix symmetry and hides communication yields the best value for the "CPU core hours" metric and significantly reduces data movement overheads.

97 MATHEMATICS AND COMPUTING↗

Speed Variation Based Power Regulation Concept for Dynamic Wireless Charging

On-road wireless charging of electric vehicles (EVs) in-motion could potentially reduce range anxiety or battery size with wide-spread deployment. The planning and implementation of such systems are greatly complicated due to their susceptibility to load variation inherent to traffic flow. Here, this paper proposes a method for derisking the potential for traffic slowdowns by compensating for reduced vehicle speed and investigates how implementation may affect system performance. A load modeling case study is presented at 200kW for a mile of high-speed roadway employing speed-based power regulation with results indicating average power usage and maximum car hosting capability can be reduced by 20% and increased by 30% respectively. An 85kHz power electronics model is developed based on designs and prototypes for an 11kW, 190m airgap static system and a 200kW dynamic wireless track. The simulation is validated in the 11kW experimental prototype and modified for 200kW operation to compare with simulated performance. Sensitivity studies are performed in MATLAB/Simulink to evaluate how parameters influence system performance and confirm the capability to reduce output power and maintain efficiency at 11 and 200kW. The static 11kW experimental system operates at 93.6% efficiency and multiple options exist to reduce power while maintaining efficiency greater than 90%. The capability to dynamically modify power output from WPT coils, in an experimentally validated simulation, enables techniques to significantly mitigate load variability due to reductions in vehicle speed.

42 ENGINEERING↗

TAS: 89 0227: TAS Recovery Act - Optimization and Control of Electric Power Systems: ARRA

The name SuperOPF is used to refer several projects, problem formulations and soft-ware tools intended to extend, improve and re-define some of the standard methods of optimizing electric power systems. Our work included applying primal-dual interior point methods to standard AC optimal power flow problems of large size, as well as extensions of this problem to include co-optimization of multiple scenarios. The original SuperOPF problem formulation was based on co-optimizing a base scenario along with multiple post-contingency scenarios, where all AC power flow models and constraints are enforced for each, to find optimal energy contracts, endogenously determined locational reserves and appropriate nodal energy prices for a single period optimal power flow problem with uncertainty. This led to example non-linear programming problems on the order of 1 million constraints and half a million variables. The second generation SuperOPF formulation extends this by adding multiple periods and multiple base scenarios per period. It also incorporates additional variables and constraints to model load following reserves, ramping costs, and storage resources. A third generation of the multi-period SuperOPF, adds both integer variables and a receding horizon framework in which the problem type is more challenging (mixed integer), the size is even larger, and it must be solved more frequently, pushing the limits of currently available algorithms and solvers. The consideration of transient stability constraints in optimal power flow (OPF) problems has become increasingly important in modern power systems. Transient stability constrained OPF (TSCOPF) is a nonlinear optimization problem subject to a set of algebraic and differential equations. Solving a TSCOPF problem can be challenging due to (i) the differential-equation constraints in an optimization problem, (ii) the lack of a true analytical expression for transient stability in OPF. To handle the dynamics in TSCOPF, the set of differential equations can be approximated or converted into equivalent algebraic equations before they are included in an OPF formulation. In Chapter 4, a rigorous evaluation of using a predefined and fixed threshold for rotor angles as a mean to determine transient stability of the system is developed. TSCOPF can be modeled as a large-scale nonlinear programming problem including the constraints of differential-algebraic equations (DAE). Solving a TSCOPF problem can be challenging due to (i) the differential-equation constraints in an optimization problem, (ii) the lack of a true analytical expression for transient stability constraint in OPF. Unfortunately, even the current best TSCOPF solvers still suffer from the curse of dimensionality and unacceptable computational time, especially for large-scale power systems with multiple contingencies. In chapter 5, thse issues will be addressed and a new method to incorporate the transient stability constraints will be presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quenching measurements and modeling of a boron-loaded organic liquid scintillator

Organic liquid scintillators are used in a wide variety of applications in experimental nuclear and particle physics. Boron-loaded scintillators are particularly useful for detecting neutron captures, due to the high thermal neutron capture cross section of 10 B. These scintillators are commonly used in neutron detectors, including the DarkSide-50 neutron veto, where the neutron may produce a signal when it scatters o protons in the scintillator or when it captures on 10 B. Reconstructing the energy of these recoils is complicated by scintillation quenching. Understanding how nuclear recoils are quenched in these scintillators is an important and dicult problem. In this article, we present a set of measurements of neutron-induced proton recoils in a boron-loaded organic liquid scintillator at recoil energies ranging from 57-467 keV, and we compare these measurements to predictions from different quenching models. We and that a modified Birks' model whose denominator is quadratic in dE=dx best describes the measurements, with χ 2 /NDF = 1:6. This result will help model nuclear recoil scintillation in similar detectors and can be used to improve their neutron tagging efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A hybrid architecture for volt-var control in active distribution grids

Modern active distribution grids are characterized by the increasing penetration of distributed energy resources (DERs). The proper coordination and scheduling of a large numbers of these small-scale and spatially distributed DERs is necessary, and warrants the use of novel distributed approaches. In this paper, we propose a hybrid volt-var control architecture for the distribution grid, which leverages existing centralized and local approaches to planning, decision making, and control, and augments it with distributed optimization and distributed control for DER management. First, we propose a convex model to describe the power physics of distribution grids of meshed topology and unbalanced structure, based on current injection and McCormick Envelopes. Second, we employ the distributed proximal atomic coordination (PAC) algorithm to coordinate DERs to provide voltage support. We implement volt-var optimization by optimally coordinating DERs including PV smart inverters and demand response. We present results using the IEEE-34 bus network, using real data from a distribution feeder in Hawaii, to model load and PV generation. Different levels of DER penetration and objective functions are simulated. Finally, our results show the need for the coordination of DERs to improve voltage profiles, even in networks with existing voltage control devices. Further, we show the need for flexible reactive power capabilities to achieve desired grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗