Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Modal Testing of a Flexible Wing on a Dynamically Active Test Fixture Using Fixed Base Correction Method - IFASD 2019

In modal testing and finite element model correlation, analysts desire modal results using free-free or rigid boundary conditions to ease comparisons of test versus analytical data. It is often expensive both in cost and schedule to build and test with boundary conditions that replicate the free-free or rigid boundaries. Static test fixtures for load testing are often large, heavy, and unyielding, but do not provide adequate boundaries for modal tests because they are dynamically too flexible and often contain natural frequencies within the test article frequency range of interest. The dynamic coupling between the test article and test fixture complicates the model updating process because significant effort needs to be spent on modeling the test fixture and boundary conditions in addition to the test article. If the modal results could be corrected for fixture coupling, then setups used for other structural testing could be adequate for modal testing and would allow significant schedule and cost savings by eliminating a unique setup for only modal testing. To simplify future modal tests, this paper reports on a fixed base correction method that was investigated during modal testing of a full-scale, half-span, flexible wing cantilevered from a static test fixture. The results of this fixed base correction approach look very promising. The method aided in producing similar wing modal characteristics for two different physical boundary configurations of a dynamically active test fixture.

modal testing↗

Modal Testing of a Flexible Wing on a Dynamically Active Test Fixture Using the Fixed Base Correction Method

In modal testing and finite element model correlation, analysts desire modal results using free-free or rigid boundary conditions to ease comparisons of test versus analytical data. It is often expensive both in cost and schedule to build and test with boundary conditions that replicate the free-free or rigid boundaries. Static test fixtures for load testing are often large, heavy, and unyielding, and not provide adequate boundaries for modal tests because they are dynamically too flexible and often contain natural frequencies within the test article frequency range of interest. The dynamic coupling between the test article and test fixture complicates the model updating process because significant effort needs to be spent on modeling the test fixture and boundary conditions in addition to the test article. If the modal results could be corrected for fixture coupling, then setups used for other structural testing could be adequate for modal testing and would allow significant schedule and cost savings by eliminating a unique setup for only modal testing. To simplify future modal tests, this report describes a Fixed Base Correction method that was investigated during modal testing of a full-scale, half-span, flexible wing cantilevered from a static test fixture. The results of this Fixed Base Correction approach look very promising. The method aided in producing similar wing modal characteristics for two different physical boundary configurations of a dynamically active test fixture.

Natalie D Spivey↗

EFFECTS OF LASER SHOCK PEENING ON SCC BEHAVIOR OF ALLOY 600

In this study, the effects of laser shock peening (LSP) on stress corrosion cracking (SCC) behavior of Alloy 600 in tetrathionate solution were investigated. The degree of sensitization was quantified using double loop electrochemical potentiokinetic reactivation (DLEPR) tests. The sensitized Alloy 600 was demonstrated to be susceptible to intergranular SCC in tetrathionate solution. Following LSP, residual stresses and the amount of plastic strain introduced in Alloy 600 were characterized. The effects of LSP on SCC susceptibility of Alloy 600 in tetrathionate solution were evaluated by slow strain rate tests and constant load tests. Results indicate a significant increase in resistance to crack initiation and decreased susceptibility to SCC after LSP.

36 MATERIALS SCIENCE↗

Highly Loaded Composite Strut Test Development

Highly loaded composite struts, representative of structural elements of a proposed truss-based lunar lander descent stage concept, were selected for design, development, fabrication and testing under NASA s Advanced Composites Technology program. The focus of this paper is the development of a capability for experimental evaluation of the structural performance of these struts. Strut lengths range from 60 to over 120 inches, and compressive launch and ascent loads can exceed -100,000 lbs, or approximately two times the corresponding tensile loads. Allowing all possible compressive structural responses, including elastic buckling, were primary considerations for designing the test hardware.

Wu, K. Chauncey↗

Hypersonic Inflatable Aerodynamic Decelerator (HIAD) Torus Mechanical Testing

The Armstrong Flight Research Center has performed loads testing of a series of developmental atmospheric entry decelerator structural components. Test setup hardware were designed and fabricated. In addition, test plan and checklist were developed for the consistent and efficient execution of the tests. Eight test articles were successfully tested in over one hundred test runs as test objectives were met. Test article buckling shapes and buckling loads were observed. Displacements and strains were also recorded as various load cases were applied. The test data was sent to Langley Research Center to help with the construction of the finite element model of the decelerator assembly.

buckling↗

Mission load dynamic tests of two undensified Space shuttle thermal protection system tiles

Two tests of undensified Space Shuttle thermal protection tiles under combined static and dynamic loads were conducted. The tiles had a density of approximately 144 Kg/cum (LI900 tiles) and were mounted on a strain isolation pad which was 0.41 cm (.160 inch) thick. A combined static and dynamic mission stress histogram representative of the W-3 area of the wing of the orbiter vehicle was applied. The stress histogram was provided by the space shuttle project. Results presented include: tabulation of measured peak and root-mean-square (RMS) accelerations in both compression and tension; peak SIP stress in compression and tension, peak and RMS amplitude response ratios; lateral to vertical response ratios; response time histories; peak stress distributions (histograms), and SIP extension measured both with and without static tension at various mission times.

Leatherwood, J. D.↗

In-flight deflection measurement of the HiMAT aeroelastically tailored wing

An electro-optical flight deflection measurement system was developed for NASA for use on the highly maneuverable aircraft technology (HiMAT) remotely piloted research vehicle (RPRV) to provide a means of evaluating the performance of the HiMAT's aeroelastically tailored composite wing and canard. A description of the flight deflection measurement system is presented from a user's viewpoint and includes the general method of operation, system capabilities and limitations, method of installation on the HiMAT vehicle, and calibration of targets. Also included is a general description of the HiMAT RPRV and its design goals. Preliminary flight deflection and bending moment data were obtained at Mach 0.8 and were extrapolated to the Mach 0.9 maneuver design condition for comparison to NASTRAN predictions and ground loads test results. The preliminary flight test results tended to agree with the results obtained from the static ground loads tests, that is, that the NASTRAN model overpredicted the streamwise twist of the composite outer wing panel.

Deangelis, V. M.↗

Compliance calibration of the short rod chevron-notch specimen for fracture toughness testing of brittle materials

The short rod chevron-notch specimen has the advantages of (1) crack development at the chevron tip during the early stage of test loading, and (2) convenient calculation of plane-strain fracture toughness from the maximum test load and from a calibration factor which depends only on the specimen geometry and manner of loading. For generalized application, calibration of the specimen over a range of specimen proportions and chevron-notch configurations is necessary. Such was the objective of this investigation, wherein calibration of the short rod specimen was made by means of experimental compliance measurements converted into dimensionless stress intensity factor coefficients.

Bubsey, R. T.↗

Effects of truncation of a predominantly compression load spectrum on the life of a notched graphite/epoxy laminate

Constant amplitude and transport wing spectrum compressive loading tests were used to explore the fatigue behavior of a notched, graphite/epoxy T300/5208 laminate specimen. Results indicate that (1) the amount of buckling near the notch allowed in the tests significantly affected fatigue life; (2) load spectrum truncation at either high or low ends produced lives greater than those obtained for the baseline complete-spectrum test, but with greater impact at the high-load end; and (3) the predictions of the Palmgren-Miner cumulative damage theory were found to always be far longer than those obtained in the spectrum loading tests.

Phillips, E. P.↗

Electronic load for testing power generating devices

Instrument tests various electric power generating devices by connecting the devices to the input of the load and comparing their outputs with a reference voltage. The load automatically adjusts until voltage output of the power generating device matches the reference.

Friedman, E. B.↗

Step-loaded creep testing of Zircaloy-4 cladding at higher temperatures in the α-phase

A refined understanding of zirconium-based cladding thermomechanical performance during rapid transients is essential for enhancing the safety and operation of light-water reactors. Traditional models for zirconium alloys under accident conditions generally assume that creep dominates fuel cladding performance. Here, these historic models have largely remained unchanged and serve as the basis for safety criteria development. As the U.S. nuclear industry pursues higher burnup levels, the increased release of fission gases during transients raises the risk of cladding failure in the low-temperature hcp α-phase, making the fidelity of these models of greater importance. Creep testing was conducted from 550–700°C with 25–120 MPa applied hoop stresses to investigate Zircaloy-4 deformation at accident-relevant temperatures in the α-phase. Step-loading was employed to capture creep behavior across a wide stress range from a single sample. The stress-strain rate data at higher temperatures (650 and 700°C) were well-described by isotropic versions of the Erbacher and Kaddour models, while the lower temperature data (550 and 600°C) were underpredicted by both anisotropic and isotropic model variants. Greater strain rates during the initial loading step at 650 and 700°C were attributed to recrystallization and grain growth of sub-micron crystallites. Yet, texture analysis revealed the basal split texture remained after testing. These observations produced results suggesting Zircaloy-4 claddings experience higher creep rates across the α-phase than previously thought, possibly related to dynamic anisotropy due to temperature dependent activation of deformation mechanisms, effects of biaxial loading, and variation in material condition between the current testing used in previous model development.

36 MATERIALS SCIENCE↗

Ducted Fuel Injection And Cooled Spray Technologies For Particulate Control In Heavy-duty Diesel Engines (Final Report)

Cooled Spray (CS) and Ducted Fuel Injection (DFI) are in-cylinder technologies for diesel engines that can reduce particulate matter and soot emissions and data has been published showing that these technologies can reduce soot emissions by 75-100% for some engines at some operating conditions. However, little is known about scaling the devices for engine size. Additionally, the performance of either technology over the engine duty cycle has not been explored. This project addresses both of these points through single-cylinder engine investigations. The objectives of this project are to provide details about dimensional scaling of these devices and to demonstrate 75% PM reduction over a range of operating conditions on a single-cylinder engine. Two engines were used for this project: a 125mm bore optically accessible engine at Sandia National Laboratories and a 168mm bore metal engine at Southwest Research Institute. The optical engine was used to study the performance of DFI and CS inserts for a large injector orifice diameter injector that is characteristic of a locomotive engine and to perform scaling studies for DFI. The metal engine was used to perform scaling and alignment studies for CS and to evaluate the technology for both EGR and non-EGR engines over the engine operating map. Modifications were required for both engines to accept the prototype inserts being tested. The optical engine required a new fuel injector, cylinder head and piston so that tests could be run at the pressures and engine speeds required. Additionally, a novel rotating stage was designed for the optical engine to simplify alignment of the modules. The metal engine required a modified cylinder head to accept CS inserts and a modified piston to provide additional space around the fuel injector for the CS inserts. Tests on the optical engine showed that DFI reduces PM emissions for both small injector orifices (0.170mm diameter) and large injector orifices (0.290mm). For high load testing, the DFI modules were not as effective as at low load testing, but it was acknowledged that minimal geometric optimization was performed and more improvements may be possible. Comparing DFI to CS and conventional diesel combustion (CDC), DFI performed better than CS or CDC. The CS geometries used in these studies may not be ideal for that engine and additional modifications likely would improve performance. Tests on the metal engine showed PM reductions as high has 80% at some operating conditions with duty-cycle PM reductions of ~50% for EGR and non-EGR configurations. The CS testing on the metal engine showed that chamfering of the fuel passage inlet either through hydro-erosion or mechanical grinding provided significant improvements in the PM reduction capabilities of the insert. Additionally, alignment sensitivities were explored and the data show that the tolerance to misalignment is approximately 0.05 to 0.1mm for the inserts that were studied here. Air-fuel ratio was shown to be important in the effectiveness of the CS inserts. In several tests, it was shown that the CS inserts are more effective at reducing the PM for high-AFR operating conditions compared to low AFR conditions. In summary, multiple designs were evaluated on both engines. It was found that for the conditions and configurations studied here, a fuel passage diameter of ~2.5mm performed best overall. Significant duty-cycle PM reductions are possible using these technologies and sensitivities to AFR, alignment fuel passage diameter and inlet fuel passage shaping were explored and are reported here. More PM reduction may be possible with improved geometric design and attention to alignment practices.

02 PETROLEUM↗

Axial-Load Fatigue Properties of 24S-T and 75S-T Aluminum Alloy as Determined in Several Laboratories

In the initial phase of a NACA program on fatigue research, axial-load tests on 24S-T3 and 75S-T6 aluminum-alloy sheet have been made at the Battelle Memorial Institute and at the Langley Aeronautical Laboratory of the National Advisory Committee for Aeronautics. The test specimens were polished and unnotched. The manufacturer of the material, the Aluminum Company of America, has made axial-load tests on 24S-T4 and 75S-T6 rod material. The test techniques used at the three laboratories are described in detail; the test results are presented and are compared with each other and with results obtained on unpolished sheet by the National Bureau of Standards. (author)

Grover, H J↗

Vibratory Loads Reduction Testing of the NASA/Army/MIT Active Twist Rotor

Recent studies have indicated that controlled strain-induced blade twisting can be attained using piezoelectric active fiber composite technology, and that such advancement may provide a mechanism for reduced rotorcraft vibrations and increased rotor performance. In order to validate these findings experimentally, a cooperative effort between the NASA Langley Research Center, the Army Research Laboratory, and the MIT Active Materials and Structures Laboratory has been developed. As a result of this collaboration a four-bladed, aeroelastically-scaled, active-twist model rotor has been designed and fabricated for testing in the heavy gas test medium of the NASA Langley Transonic Dynamics Tunnel. Initial wind tunnel testing has been conducted to assess the impact of active blade twist on both fixed- and rotating-system vibratory loads in forward flight. The active twist control was found to have a pronounced effect on all system loads and was shown to generally offer reductions in fixed-system loads of 60% to 95%, depending upon flight condition, with 1.1 to 1.4 of dynamic blade twist observed. A summary of the systems developed and the vibratory loads reduction results obtained are presented in this paper.

Wilbur, Matthew↗

A free-piston Stirling engine/linear alternator controls and load interaction test facility

A test facility at LeRC was assembled for evaluating free-piston Stirling engine/linear alternator control options, and interaction with various electrical loads. This facility is based on a 'SPIKE' engine/alternator. The engine/alternator, a multi-purpose load system, a digital computer based load and facility control, and a data acquisition system with both steady-periodic and transient capability are described. Preliminary steady-periodic results are included for several operating modes of a digital AC parasitic load control. Preliminary results on the transient response to switching a resistive AC user load are discussed.

Rauch, Jeffrey S.↗

A free-piston Stirling engine/linear alternator controls and load interaction test facility

A test facility at LeRC was assembled for evaluating free-piston Stirling engine/linear alternator control options, and interaction with various electrical loads. This facility is based on a 'SPIKE' engine/alternator. The engine/alternator, a multi-purpose load system, a digital computer based load and facility control, and a data acquisition system with both steady-periodic and transient capability are described. Preliminary steady-periodic results are included for several operating modes of a digital AC parasitic load control. Preliminary results on the transient response to switching a resistive AC user load are discussed.

Rauch, Jeffrey S.↗

Fracture toughness of brittle materials determined with chevron notch specimens

Short bar, short rod, and four-point-bend chevron-notch specimens were used to determine the plane strain fracture toughness of hot-pressed silicon nitride and sintered aluminum oxide brittle ceramics. The unique advantages of this specimen type are: (1) the production of a sharp natural crack during the early stage of test loading, so that no precracking is required, and (2) the load passes through a maximum at a constant, material-independent crack length-to-width ratio for a specific geometry, so that no post-test crack measurement is required. The plane strain fracture toughness is proportional to the maximum test load and functions of the specimen geometry and elastic compliance. Although results obtained for silicon nitride are in good mutual agreement and relatively free of geometry and size effects, aluminum oxide results were affected in both these respects by the rising crack growth resistance curve of the material.

Shannon, J. L., Jr.↗

Analysis of helicopter maneuver-loads and rotor-loads flight test data

A study was conducted in which available airload and blade response data for the NH-3A and CH-53A rotors were analyzed in an attempt to provide greater insight into the sources of rotor vibratory loads in both level and maneuvering flight. Primary emphasis in the study was placed on examining and understanding causes of high-frequency rotor control loads. Secondary objectives were: (1) to examine the effect of number of rotor blades on hub vibratory shear forces and (2) to assess which of the many terms appearing in the hub vibratory shear force expression were of most significance.

Beno, E. A.↗