Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Multi-modular power plant with dedicated electrical grid

A multi-modular power plant includes a plurality of on-site nuclear power modules that generate a power plant output, and a number of power plant systems which operate using electricity associated with a house load of the power plant. A switchyard associated with the power plant may electrically connect the power plant to a distributed electrical grid. The distributed electrical grid may be configured to service a plurality of geographically distributed consumers. Additionally, the switchyard may electrically connect the power plant to a dedicated electrical grid. The dedicated electrical grid may provide electricity generated from the power plant output to a dedicated service load, and the power plant output may be equal to or greater than a combined load of the dedicated service load and the house load. At least a portion of the power plant output may be distributed to both the power plant systems and the dedicated electrical grid.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enabling Load Following Capability in the Transatomic Power MSR

This project is dedicated towards designing a fuel processing system that enables liquid-fueled molten salt reactors (MSR) to load follow by removing the dissolved xenon in the fuel salt. As one of the Gen-IV nuclear reactor concepts, the molten salt reactor receives increasing development interests in the recent years. One distinguishing feature of the liquid-fueled molten salt reactor is its improved ability to operate in a load-following mode by including the unique online fission product removal system. Load-following means that the reactor changes its power output based on the demand on the grid. Most of the current operating nuclear reactors have limited load-following ability and operate as the base load on the grid. Due to the rapid increase of solar energy, the requirement on load-following capacity is significantly increased because of the varying power output of the solar panels, yet the traditional load-following capacity is expected to decrease as the decarbonization of the grid continues. Therefore, the ability to perform load-following operation for the nuclear reactors will greatly enhance the resilience of the grid and make nuclear energy more economically competitive. This load-following feature is included in many commercial molten salt reactor designs, such as the designs by Transatomic Power, Terrestrial Energy, and Flibe Energy. Unfortunately, detailed analysis of the fuel processing system for commercial scale MSRs is still lacking, as well as how the fuel processing quantitively impacts the load-following operation. Moreover, experimental data for many of the underlying physics of fuel processing is limited. This project aims to pave the way for the fuel processing technology to advance to the commercial stage by performing combined experimental and simulation research. During the project period, four interconnected aspects of the development of the fuel processing system in liquid-fueled molten salt reactors are investigated. These aspects are the simulation and analysis of the fission product removal system, the fuel cycle simulation, the coupled reactor neutronics and thermal hydraulics transient simulation, and the gaseous fission product removal experiment. Multiphase CFD simulations are performed for components of the processing systems, and simplified air-water experiments are carried out to provide validation data. It is concluded that the CFD simulation can satisfactorily predict the system level performance of the components, and engineering models are constructed based on this success. Fuel cycle analysis is performed for two representative MSR design, the MSBR and the Transatomic Power MSR. Open-source code SaltProc is developed to incorporate the unique fuel processing system of the MSRs. It is concluded that the removal of xenon is essential for load-following operation in thermal spectrum MSR and Molten Salt Breeder Reactor. For the Transatomic Power MSR, the xenon poisoning effect is negligible due to its relatively fast neutron spectrum, though the overall fuel cycle economics still benefits from the removal of xenon. Coupled reactor neutronics and thermal hydraulics transient simulation is performed specifically for the Transatomic Power MSR. It is concluded that the reactor core design could perform power ramping fast enough to satisfy load-following operation. Combining the findings from each aspect, it is concluded that the load-following operation of a thermal neutron MSR is dependent upon the removal of xenon, which could be achieved for a commercial sized reactor using continuous inert gas sparging in a separate system with reasonable dimensions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Grid-Supportive Loads - A New Approach to Increasing Renewable Energy in Power Systems

This paper demonstrates the potential of inverter-based loads to support grid reliability during power system transients thereby enabling reliable integration of renewable energy in power systems. Such loads are referred to in this paper as grid-supportive loads (GSLs). A new GSL model is developed that simulates the transient response capabilities that can be programmed in electronic loads. The model’s design enables it to be easily integrated in widely used commercial power system transient analysis software. Theoretical expressions are derived that explain the workings of the GSL model. The performance, numerical stability, and impact of the GSL model is validated on 9-bus and 2000-bus synthetic power system models using generator tripping and bus fault disturbances. Results on the 2000 bus system show that in the absence of frequency support from wind/solar generation resources, just 20% of loads with grid-supportive capabilities can improve frequency response by up to 2000 MW/0.1 Hz and reduce deviation in frequency at nadir by up to 60% compared to the situation when GSLs are absent. Power system reliability also improves under fault events. Here, it is further shown that GSLs can aid in integrating more renewable generation without degrading the overall transient response of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordination of thermostatically controlled loads

Apparatus and methods for a market-based control framework to coordinate a group of autonomous thermostatically controlled loads (TCL) to achieve system-level objectives with pricing incentives is disclosed. In one example of the disclosed technology, a method of providing power to a load via a power grid by submitting bids to a coordinator includes determining an energy response relating price data for one or more energy prices to quantity data for power to be consumed by the load, sending a bid for power for a finite time period based on the energy response to the coordinator, and receiving a clearing price based on: the bid, on bids received from a plurality of additional loads, and a feeder power constraint. In some examples, the energy response is based at least in part on an equivalent thermal parameter model and a control policy indicating one or more power states for the load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Upwind vs. downwind: loads and acoustics of a 1.5 MW wind turbine

This paper discusses the motivation, preparation, risk mitigation, execution, and results of a full-scale experiment where the conventional upwind rotor of a 1.5 MW wind turbine was operated in a downwind configuration. The experiment took place at the National Renewable Energy Laboratory Flatirons Campus in Colorado, USA, and involved the collection of loads and power together with acoustic measurements from an array of four microphones. To validate the numerical predictions of the aeroelastic solver OpenFAST in terms of loads and performance, 410 min of downwind operation and 960 min of conventional upwind operations were used. In the wind speed range from 4.5 to 12.5 m s−1, the downwind rotor generates higher damage equivalent loads for the blade root flapwise moment, blade root edgewise moment, and tower-base fore-aft moment compared to the upwind rotor. For these metrics of fatigue loads, numerical predictions match the experimental observations well. OpenFAST is, however, also seen underpredicting a power gain in the downwind rotor. In terms of acoustics, the overall sound pressure levels recorded in the field are similar between the upwind and downwind cases, but downwind operation worsens the metrics describing amplitude modulation.

17 WIND ENERGY↗

Coordination of thermostatically controlled loads

Apparatus and methods for a market-based control framework to coordinate a group of autonomous thermostatically controlled loads (TCL) to achieve system-level objectives with pricing incentives is disclosed. In one example of the disclosed technology, a method of providing power to a load via a power grid by submitting bids to a coordinator includes determining an energy response relating price data for one or more energy prices to quantity data for power to be consumed by the load, sending a bid for power for a finite time period based on the energy response to the coordinator, and receiving a clearing price based on: the bid, on bids received from a plurality of additional loads, and a feeder power constraint. In some examples, the energy response is based at least in part on an equivalent thermal parameter model and a control policy indicating one or more power states for the load.

Lian, Jianming↗

Annual Performance of the Second-Generation Variable-Geometry Oscillating Surge Wave Energy Converter

Recent studies in wave energy have highlighted the need for a structured innovation approach in wave energy converter (WEC) design because cost-of-energy estimates have remained high. One specific innovation being investigated by the National Renewable Energy Laboratory is WEC geometry control, which uses control surfaces in combination with an oscillating surge WEC (OSWEC) to increase device availability and power generation while limiting structural costs. This study performs the first analysis of annual performance for a novel OSWEC with geometry control to understand how the geometry control affects availability, annual power generation, and structural loadings like the power-take-off (PTO) torque or surge foundation force. Device hydrodynamic coefficients are calculated using linear potential theory for six geometry configurations. A nonideal PTO system is assumed and quadratic viscous damping losses are considered. Annual performance is evaluated and compared for three U.S. wave energy sites. The WEC geometry and PTO system are controlled on a sea-state basis to optimize for power capture while remaining under limits set on motion amplitude and structural loads. Results indicate that geometry control can increase availability up to 25 days in an average year depending on design limits, increase average power generation, and significantly reduce peak structural loads.

30 DIRECT ENERGY CONVERSION↗

Evaluating the Impact of Off-Design CHP Performance on the Optimal Sizing and Dispatch on Hybrid Renewable-CHP Distributed Energy Resources

The maturation of distributed energy resources (DER) has prompted the exploration of their deployment in commercial building applications due to their potential to supply energy at lower costs and emissions rates compared to centralized generation. While several software tools exist for evaluating the techno-economic potential of integrated renewable energy and combined heat and power (CHP) systems for distributed generation applications, many suffer from poor accuracy in capturing off-design (part load and changes in ambient air temperature and pressure) performance characteristics of microturbines, combustion turbines, or internal combustion engines. Thus, this paper presents a methodology for integrating these off-design characteristics in the mixed-integer linear program within REopt, a hybrid DER screening tool. The economic impact of the CHP off-design performance is observed through several application studies of various hybrid system configurations in different climates. Each study indicates how CHP off-design performance influences optimal sizing and dispatch decisions and therefore overall system economic value. We observe through case studies that modeling without the off-design effects, depending on the CHP prime mover and site, can result in Net Present Value predictions of hybrid systems that can be overoptimistic in frequently hot climates (up to 52%), too conservative in frequently cold climates (up to 11%), or unaffected (+/-1%) in temperate climates. Cases also highlight several advantages of hybrid systems relative to non-hybrid systems such as total economic value and the systems' ability to mitigate potentially negative consequences attributed to off-design performance.

ambient de-rate↗

Impact of Open Communication Networks on Load Frequency Control with Plug-In Electric Vehicles by Cyber-Physical Dynamic Co-Simulation

With the increasing electrification of the transportation sector to achieve the carbon neutrality objective, despite the challenges of charging electric vehicles (EV), there are also opportunities through smart charging EVs to improve system frequency stability; however, EV control technologies might require nontraditional communication support. This paper investigates the impacts of communication variations of EV on power system load frequency control through a cyber-physical dynamic system (CPDS) co-simulation. Here, the CPDS is built upon our previously developed transmission-and-distribution dynamic co-simulation model with the added communication variation functions (i.e., delay and packet loss). The case studies consider multiple communication variation scenarios when the system experiences an N-1 generation trip contingency. The scenarios include communication delays and packet loss using both homogeneous and heterogeneous assumptions. The outcomes of this work can help improve EV frequency regulation services and provide robust and effective tests for different load frequency control algorithms of the future power systems.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Electromagnetic Transient Modeling of Large Data Centers for Grid-Level Studies

The magnitude and complexity of electricity usage patterns from large data centers are having significant impacts on the operation and dynamics of the power grid; grid operators and planners require a range of specialized data center models to properly evaluate these impacts and specify technical solutions as needed. Towards addressing this need, Pacific Northwest National Laboratory (PNNL) has developed a library of electromagnetic transient (EMT) models for grid-level studies of data centers called the data center model library (DML). This report describes how the DML was created and how it may properly be used. The models present in the DML are generic models; subject matter expertise and additional technical data are needed to modify these models before they can represent any real data center. However, they will significantly reduce the level of effort required to develop site-specific models and can serve as a common starting point to guide industry towards a more refined consensus. Most of the models within DML are dedicated to representing the power electronics interfaces commonly used in modern data centers, such as double-conversion uninterruptible power supplies and single-phase power factor correction converters. These models are intended for use in grid-level studies and are a simplified aggregation of many small components. That said, background material on the physical and electrical design of large data centers is provided as companion material so that users can be aware of many of the details which have been omitted or streamlined as a matter of practical necessity. Additionally, guidance on the application of EMT analysis for data center interconnection studies is provided, which aids users in identifying when the DML is necessary and what sort of additional model development may be necessary for conducting real-world studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Autonomous Control of Microreactors Using Multi-Agent Reinforcement Learning

In order for microreactors to be economically competitive, operation costs will need to be minimized through some degree of autonomous control. Previous work has demonstrated the effectiveness of reinforcement learning (RL) for load-following control in a drum-controlled microreactor. This study extends that work by exploring the potential of RL to independently control each of the reactor’s drums. We compare a single-agent RL approach with a multi-agent RL (MARL) framework, testing them for generalization across different load-following power profiles and control timescales, and for robustness in cases of randomly disabled control drums. Since the point kinetics simulation environment used in this study cannot resolve spatial effects, we assume that in the absence of spatially localized disturbances, optimal drum movements should be symmetrical. We demonstrate that single-agent RL is able to achieve accurate performance only when symmetric actions are ignored; otherwise, it fails to train a useful controller. Meanwhile, the MARL framework performs symmetric actions by design and trains a robust, accurate agent, as evidenced by mean absolute errors in power matching of 0.41% for the training power profile, 0.68% for a profile with half the drums disabled, and 0.21% for a profile on a realistic load-following time horizon.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration of a modeling toolkit for the design of building electrical distribution systems

The deployment of building equipment (e.g., lighting, security) and miscellaneous electrical loads that fundamentally require DC power for operation is increasing. Powering these DC loads has traditionally required an AC/DC converter, but the installation of photovoltaic (PV) and battery energy storage systems that primarily produce DC power eliminates the need for AC/DC converters at each end-device. However, analyzing system energy efficiency and cost for different electrical distribution architectures can be challenging as software tools that support this are not readily available. This paper presents preliminary results from a laboratory verification of the Building Electrical Efficiency Analysis Model (BEEAM) toolkit that was developed to address this gap. Three different eight-luminaire lighting systems comprised of market-available products were designed and modeled: one that used traditional AC distribution, a second that used a hybrid AC -to- centralized DC electrical distribution architecture, and a third that used a hybrid AC -to- distributed DC architecture. Notably, AC/DC conversions are required in all three systems. BEEAM models for LED drivers as well as Power-over-Ethernet (PoE) switches were created using laboratory characterization data. The lighting systems were simulated in Modelica, and the results were compared with each other and physics-based expectations. Simulation results show that PoE system energy efficiency is highly dependent on both device specification (e.g., LED driver and PoE switch efficiency) and system architecture (e.g., PoE switch loading) choices, as expected. For the products and system architectures selected for this study, the two DC systems were found to be less efficient than the AC system over the course of typical operation. In future work, simulation results will be compared with laboratory measurements to validate the usefulness of this software for design, and lighting systems with integrated PV and battery energy storage will be simulated to quantify the energy performance improvements that result from the elimination of some AC/DC converters.

Waghale, Anay S.↗

Coordinated net-load management

A management device includes at least one processor communicatively coupled to at least one energy resource controller controlling at least one energy resource and to at least one deferrable load controller controlling power to at least one deferrable load. The is configured to receive an indication, determined based on a frequency value of an electrical network and a nominal frequency value, that a frequency anomaly event has occurred. Responsive to receiving the indication that the frequency anomaly event has occurred, the processor is also configured to determine, for at least one of the energy resource and the deferrable load, based on the frequency value, the nominal frequency value, and a power value of the electrical network, a respective power command, and cause at least one of the at least one energy resource and the at least one deferrable load to modify operation based on the respective power command.

42 ENGINEERING↗

Coordinated net-load management

A management device includes at least one processor communicatively coupled to at least one energy resource controller controlling at least one energy resource and to at least one deferrable load controller controlling power to at least one deferrable load. The is configured to receive an indication, determined based on a frequency value of an electrical network and a nominal frequency value, that a frequency anomaly event has occurred. Responsive to receiving the indication that the frequency anomaly event has occurred, the processor is also configured to determine, for at least one of the energy resource and the deferrable load, based on the frequency value, the nominal frequency value, and a power value of the electrical network, a respective power command, and cause at least one of the at least one energy resource and the at least one deferrable load to modify operation based on the respective power command.

Lundstrom, Blake Richard↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Comparative Analysis of HEATNETS for Geothermal Network Performance: Preprint

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer, rather than also comparing control systems responses. HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study shows that HEATNETS, while not intended to replace other modeling tools, can be a unique modeling tool for the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

Comparison of three DWM-based wake models at above-rated wind speeds

In this study we investigate three mid-fidelity wind turbine wake models based on the dynamic wake meandering (DWM) model principle, and compare their performance with a reference dataset, produced with large-eddy simulations using the actuator line model. The models are compared with respect to flow field, power, and loads on a row of four 5MW reference turbines experiencing above-rated wind conditions. In general, the DWM models show fairly good agreement with large-eddy simulation for the time-averaged flow fields, blade forces and power, with increasing differences along the turbine row. Also when comparing fatigue loads of blade root moments, the differences between the models increase further into the row, with deviations up to 25 % of the reference case. However, while the development in blade root moment fatigue along the turbine row is predominantly driven by the energy content at the frequency corresponding to the turbine's rotational period (1 P ) for the DWM models, the large-eddy simulation results suggest that the key drivers for the blade root and tower loads are the increase in meandering and energy at higher frequencies (> 1 P ) deeper into the turbine row. For the tower loads, the DWM models highly underestimate the fatigue for the waked turbines. From these results, we suggest priorities for future model developments so that robust model implementations can be used in wind farm design and operation.

17 WIND ENERGY↗