Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid helium cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Compact, High-Power Superconducting Electron Linear Accelerators for MW Industrial Applications

Fermilab has developed a novel concept for an industrial electron linac using Nb₃Sn coating technology and conduction cooling. We will show the range of multi-cavity linac designs targeted toward various applications. We will also discuss technology development status with results on conduction cooling of SRF cavities based on cryocoolers, which removes the need for liquid Helium, thus making SRF technology accessible to industrial applications. These conduction-cooled linacs can generate electron beam energies up to 10 MeV in continuous-wave operation and can reach higher power (>=1 MW) by combing several modules. Compact and light enough to mount on mobile platforms, our machine is anticipated to enable new in-situ environmental remediation applications such as waste-water treatment for urban areas, X-ray medical device sterilization, and innovative pavement applications. We also show cost-economics and key R&D areas that much be addressed for a practical machine.

43 PARTICLE ACCELERATORS↗

Space simulation experiments on reaction control system thruster plumes

A space simulation procedure was developed for studying rocket plume contamination effects using a 5-pound bipropellant reaction control system thruster. Vacuum chamber pressures of 3 x 10 to the minus 5 torr (70 miles altitude) were achieved with the thruster firing in pulse trains consisting of eight pulses (50 msec on, 100 msec off, and seven minutes between pulse trains). The final vacuum was achieved by cooling all vacuum chamber surfaces to liquid helium temperature and by introducing a continuous argon leak of 48 std. cc/sec into the test chamber. An effort was made to simulate propellant system flow dynamics corresponding to actual spacecraft mission use. Fast time response liquid flow rate measurements showed that large variations occurred in the ratio of oxidizer to fuel flow for pulse-on times up to 120 msec. These variations could lead to poor combustion efficiency and the production of contamination.

Cassidy, J. F.↗

Magnetic refrigeration for low-temperature applications

The application of refrigeration at low temperatures ranging from production of liquid helium for medical imaging systems to cooling of infrared sensors on surveillance satellites is discussed. Cooling below about 15 K with regenerative refrigerators is difficult because of the decreasing thermal mass of the regenerator compared to that of the working material. In order to overcome this difficulty with helium gas as the working material, a heat exchanger plus a Joule-Thomson or other exponder is used. Regenerative magnetic refrigerators with magnetic solids as the working material have the same regenerator problem as gas refrigerators. This problem provides motivation for the development of nonregenerative magnetic refrigerators that span approximately 1 K to approximately 0 K. Particular emphasis is placed on high reliability and high efficiency. Calculations indicate considerable promise in this area. The principles, the potential, the problems, and the progress towards development of successful 4 to 20 K magnetic refrigerators are discussed.

Barclay, J. A.↗

Compact cryomodule for mobile stand-alone superconducting industrial accelerators

Superconducting RF (SRF) accelerators have the potential to be more profitable in comparison with normally conducting accelerators, as long they can be made compact, achieve operational simplicity, autonomy, trans- portability, satisfactory energy efficiency, as well as have reasonable costs. The development of SRF technologies such as Nb 3 Sn coating, conductively-cooled resonators, and high-capacity liquid-helium-free cryocoolers made SRF accelerators mobile and energetically and economically efficient at a beam power of tens of kW. One of the key elements of such an accelerator is the cryomodule, which must have minimal thermal losses to enable operation from low power cryoheads and enable conductive cooling of SRF resonator. In this research we present the design and test results of a compact cryomodule for an industrial stand-alone SRF linear accelerator proto- type, based on 650 MHz elliptical resonators, being developed at Fermi National Accelerator Laboratory.

43 PARTICLE ACCELERATORS↗

Advances in cryogenic engineering. Vols. 35A & 35B - Proceedings of the 1989 Cryogenic Engineering Conference, University of California, Los Angeles, July 24-28, 1989

The book presents a review of literature on superfluid helium, together with papers under the topics on heat and mass transfer in He II; applications of He II for cooling superconducting devices in space; heat transfer to liquid helium and liquid nitrogen; multilayer insulation; applications of superconductivity, including topics on magnets and other devices, magnet stability and coil protection, and cryogenic techniques; and refrigeration for electronics. Other topics discussed include refrigeration of superconducting systems; the expanders, cold compressors, and pumps for liquid helium; dilution refrigerators; magnetic refrigerators; pulse tube refrigerators; cryocoolers for space applications; properties of cryogenic fluids; cryogenic instrumentation; hyperconducting devices (cryogenic magnets); cryogenic applications in space science and technology and in transportation; and miscellaneous cryogenic techniques and applications.

Fast, R. W.↗

The cryogenic subsystem for the X-ray spectrometer on the Advanced X-Ray Astrophysics Facility (AXAF)

The X-ray Spectrometer (XRS) instrument on the Advanced X-ray Astrophysics Facility (AXAF) will use X-ray detectors that operate at 0.1 K. The detectors will be maintained at 0.1 K by an Adiabatic Demagnetization Refrigerator (ADR) that operates inside a liquid helium dewar. The ADR rejects approximately 2 mW of heat to the stored liquid helium. With this low instrument heat load, the liquid helium dewar will have a long lifetime if the parasitic heat load on the helium from the surrounding warm facility is minimized. Spaceborne helium dewars typically use up to 3 vapor cooled shields to intercept the parasitic heat load. The XRS will add mechanical coolers to provide additional cooling to the outer vapor cooled shield. The cryogenic system consists of an ADR, a liquid helium dewar, mechanical coolers, and a thermal strap to connect the coolers to the dewar. The lifetime of the stored cryogen is calculated to be up to 5 years. This cryogenic system is described, with particular attention given to the dewar, mechanical cooler, and ADR design, testing, and trade studies. A breadboard ADR is presently being fabricated and tested. The status of the construction and testing of this breadboard will be described.

Castles, Stephen H.↗

Study of helium transfer technology for STICCR: Fluid management

The Space Infrared Telescope Facility (SIRTF) is a long life cryogenically cooled space based telescope for infrared astronomy from 2 to 700 microns currently under study and planned for launch in the mid 90's. SIRTF will operate as a multi-user facility, initially carrying 3 instruments at the focal plane. It will be cooled to below 2 K by superfluid liquid helium to achieve radiometric sensitivity limited only by the statistical fluctuations in the natural infrared background radiation over most of its spectral range. The lifetime of the mission will be limited by the lifetime of the liquid helium supply, and is currently baselined to be 2 years. Candidates are reviewed for a liquid management device to be used in the resupply of liquid helium, and for the selection of an appropriate candidate.

Frank, D. J.↗

Measuring the Liquid Helium Volume on XRISM and Predicting the Liquid Lifetime

The XRISM/Resolve instrument uses an adiabatic demagnetization refrigerator (ADR) to cool microcalorimeters to 50 mK. The cryogenic system to support the ADR consists of a liquid helium dewar and 5 cryocoolers that provide a semi-redundant system. Operation of the ADR requires either a liquid helium heat sink at 1.2 K or 4.5 K heat sink provided by a multi-stage cryocooler system. The 5 cryocoolers also provide thermal protection to the liquid helium dewar. To calculate the expected lifetime of the liquid helium system, the liquid helium volume was measured before launch and several techniques were employed to determine on-orbit boil off rate.

Michael Dipirro↗

Study on Conduction Cooling of Superconducting Magnets for the ILC Main Linac

In the main linac of the International Linear Collider (ILC), superconducting magnets for beam focusing and steering will be located periodically in superconducting RF (SRF) cavity string for beam acceleration in common cryomodules. A concept of conduction cooling of the combined-functioned, splittable superconducting magnets has been proposed and investigated to adapt much different features and to meet different requirements for the superconducting magnet and SRF cavity in fabrication, assembly, and operation. It is required to integrate the superconducting magnet after the SRF cavity string assembly which completed under an ultra-clean environment. The magnet must be conductively cooled down through thermal links to a liquid helium supply pipe. According to this concept, a model magnet development was carried out in cooperation with Fermilab and KEK, and has been demonstrated in KEK superconducting RF test facility (STF). In addition, an important issue has been recently identified. High gradient SRF cavities naturally emit field emission electron flux from the inner surface, so-called dark current. It may pass through the subsequent SRF cavity string and penetrate into the superconducting magnets placed downstream. It may heat up the superconducting coils, and may cause a quench. Therefore, further study on reliable conduction cooling and to secure the superconducting magnet operation with a keeping sufficient safety margin is quite essential. In this paper, we report the installation, the improvement achieved in STF, and the R&D progress in the study on the conduction cooling of the superconducting magnet for the ILC main linac.

43 PARTICLE ACCELERATORS↗

Low gravity phase separator

An apparatus is described for phase separating a gas-liquid mixture as might exist in a subcritical cryogenic helium vessel for cooling a superconducting magnet at low gravity such as in planetary orbit, permitting conservation of the liquid and extended service life of the superconducting magnet.

Smoot, G. F.↗

Development of a motorized cryovalve for the control of superfluid liquid helium

Recent advances in the technology of infrared detectors have made possible a wide range of scientific measurements and investigations. One of the requirements for the use of sensitive IR detectors is that the entire instrument be cooled to temperatures approaching absolute zero. The cryogenic cooling system for these instruments is commonly designed as a large dewar containing liquid helium which completely surrounds the apparatus. Thus, there is a need for a remotely controlled, motorized cryovalve that is simple, reliable, and compact and can operate over extended periods of time in cryo-vac conditions. The design, development, and test of a motorized cryovalve with application to a variety of cryogenic systems currently under development is described.

Lorell, K. R.↗

Space simulation experiments on reaction control system thruster plumes.

A space simulation procedure was developed for studying rocket plume contamination effects using a 5-lb bipropellant reaction control system thrustor. Vacuum chamber pressures of 0.00003 torr (70 miles altitude) were achieved with the thrustor firing in pulse trains consisting of eight pulses - 50 msec on, 100 msec off, and seven minutes between pulse trains. The final vacuum was achieved by cooling all vacuum chamber surfaces to liquid-helium temperature and by introducing a continuous argon leak of 48 std. cc/sec into the test chamber. Fast time response liquid flow rate measurements showed that large variations occurred in the ratio of oxidizer to fuel flow for pulse-on times up to 120 msec. These variations could lead to poor combustion efficiency and the production of contamination.

Cassidy, J. F.↗

BASD: SIRTF Telescope Instrument Changeout and Cryogen Replenishment (STICCR) study

The Space Infrared Telescope Facility (SIRTF) is a long-life cryogenically cooled space-based telescope for infrared astronomy from 2 micrometer to 700 miocrometers currently under study by NASA-ARC, and planned for launch in approximately the mid 90's. SIRTF will operate as a multi-user facility, initially carrying 3 instruments at the focal plane. It will be cooled to below 2 K by superfluid liquid helium to achieve radiometric sensitivity limited only by the statistical fluctuations in the natural infrared background radiation over most of its spectral range. The lifetime of the mission will be limited by the lifetime of the liquid helium supply, and is currently baselined to be 2 years. The telescope changes required to allow in-space replenishment of the 2,000 liter superfluid helium tank are investigated. A preliminary design for the space services equipment is also developed. The impacts of basing the equipment and servicing on the space station are investigated. Space replenishment and changeout of instruments requires changes to the telescope design and preliminary concepts are presented.

Mord, A. J.↗

SIRTF Telescope Instrument Changeout and Cryogen Replenishment (STICCR) Study

The Space Infrared Telescope Facility (SIRTF) is a long-life cryogenically cooled space-based telescope for infrared astronomy from 2 to 700 micrometers. SIRTF is currently under study by NASA-ARC (Reference AP) and planned for launch in approximately the mid 1990s. SIRTF will operate as a multiuser facility, initially carrying three instruments at the focal plane. It will be cooled to below 2 K by superfluid liquid helium to achieve radiometric sensitivity limited only by the statistical fluctuations in the natural infrared background radiation over most of its spectral range. The lifetime of the mission will be limited by the lifetime of the liquid helium supply, and baseline is currently to be 2 years. The telescope changes required to allow in-space replenishment of the 4,000-L superfluid helium tank was investigated. A preliminary design for the space services equipment was also developed. The impacts of basing the equipment and servicing on the space station were investigated. Space replenishment and changeout of instruments required changes to the telescope design. Preliminary concepts are presented.

Nast, T. C.↗

Lightweight Liquid Helium Dewar for High-Altitude Balloon Payloads

Astrophysical observations at millimeter wavelengths require large (2-to-5- meter diameter) telescopes carried to altitudes above 35 km by scientific research balloons. The scientific performance is greatly enhanced if the telescope is cooled to temperatures below 10 K with no emissive windows between the telescope and the sky. Standard liquid helium bucket dewars can contain a suitable telescope for telescope diameter less than two meters. However, the mass of a dewar large enough to hold a 3-to-5-meter diameter telescope would exceed the balloon lift capacity. The solution is to separate the functions of cryogen storage and in-flight thermal isolation, utilizing the unique physical conditions at balloon altitudes. Conventional dewars are launched cold: the vacuum walls necessary for thermal isolation must also withstand the pressure gradient at sea level and are correspondingly thick and heavy. The pressure at 40 km is less than 0.3% of sea level: a dewar designed for use only at 40 km can use ultra thin walls to achieve significant reductions in mass. This innovation concerns new construction and operational techniques to produce a lightweight liquid helium bucket dewar. The dewar is intended for use on high-altitude balloon payloads. The mass is low enough to allow a large (3-to-5-meter) diameter dewar to fly at altitudes above 35 km on conventional scientific research balloons without exceeding the lift capability of the balloon. The lightweight dewar has thin (250- micron) stainless steel walls. The walls are too thin to support the pressure gradient at sea level: the dewar launches warm with the vacuum space vented continuously during ascent to eliminate any pressure gradient across the walls. A commercial 500-liter storage dewar maintains a reservoir of liquid helium within a minimal (hence low mass) volume. Once a 40-km altitude is reached, the valve venting the vacuum space of the bucket dewar is closed to seal the vacuum space. A vacuum pump then evacuates the dewar vacuum space to provide the necessary thermal isolation. Liquid helium may then be transferred from the storage dewar into the bucket dewar to cool the telescope inside the bucket dewar. By splitting the functions of helium storage and in-flight thermal isolation, the parasitic mass associated with the dewar pressure vessel is eliminated to achieve factor-of-five or better reduction in mass. The lower mass allows flight on conventional scientific research balloons, even for telescopes 3 to 5 meters in diameter.

Kogut, Alan↗

A liquid/gas phase separator for He-I and He-II

A liquid/gas phase separator has been developed which separates both liquid He-I and He-II from their vapor. The phase separator was designed for the Superfluid Helium On Orbit Transfer (SHOOT) Flight Demonstration both to cool the liquid He after launch (at temperatures between 2.8 and 4.3 K) to the operating temperature of 1.4 K and as a low rate vent on orbit to maintain operating temperature. The phase separator is made of high-purity copper disks held apart by 6 micron Kevlar fibers. It works on the principle of conducting heat from within the dewar to vaporize liquid as it is throttled in the slits to efficiently cool the remaining liquid. Laboratory tests have demonstrated perfect phase separation for both He at its saturated vapor pressure from 1.2 to 4.3 K and for He-II at 2.13 K at pressures from 4.6 to 112 kPa. The performance of this phase separator during lab testing as well as expected performance in space is discussed.

Shirron, P. J.↗

A study of the vent pipe for the gravity probe-B

The Gravity Probe B experiment to test Einstein's relativity theory is a possible Space Shuttle project. Cooling of the gyroscopes and thrusting of the Probe into a zero-drag environment is accomplished by vaporizing liquid helium and venting the gas from the Probe through a nozzle system. In order to avoid malfunctioning of this cooling-thruster system, the pressure difference across the vent pipe-thruster system must be maintained to be less than the vapor pressure of liquid helium at the given temperature. This study investigated helium gas flow through the vent pipe for various configurations, mass flow rates, and pipe diameters. In addition, pertinent properties of both liquid and gaseous helium were investigated. It was observed that helical coiling of the pipe about the Dewar caused less frictional drag and less pressure change than did sharp pipe bending. Also, for various flow rates and nozzle throat area sizes, the system would malfunction for a given bath temperature.

Knoshaug, R. N.↗

Zero Boil-Off Methods for Large Scale Liquid Hydrogen Tanks Using Integrated Refrigeration and Storage

NASA has completed a series of tests at the Kennedy Space Center to demonstrate the capability of using integrated refrigeration and storage (IRAS) to remove energy from a liquid hydrogen (LH2) tank and control the state of the propellant. A primary test objective was the keeping and storing of the liquid in a zero boil-off state, so that the total heat leak entering the tank is removed by a cryogenic refrigerator with an internal heat exchanger. The LH2 is therefore stored and kept with zero losses for an indefinite period of time. The LH2 tank is a horizontal cylindrical geometry with a vacuum-jacketed, multi-layer insulation system and a capacity of 125,000 liters. The closed-loop helium refrigeration system was a Linde LR1620 capable of 390W cooling at 20K (without any liquid nitrogen pre-cooling). Three different control methods were used to obtain zero boil-off: temperature control of the helium refrigerant, refrigerator control using the tank pressure sensor, and duty cycling (on/off) of the refrigerator as needed. Summarized are the IRAS design approach, zero boil-off control methods, and results of the series of zero boil-off tests.

ZBO↗