Experimental data shows that both ionization charge and scintillation light in LAr depend on the deposited energy density ($dE/dx$) and electric field ($\mathcal{E}$). Moreover, free ionization charge and scintillation light are anticorrelated, complementary at a given ($dE/dx$, $\mathcal{E}$) pair. We present LArQL, a phenomenological model that provides the anticorrelation between light and charge and its dependence on the deposited energy as well as on the electric field applied. It modifies the Birks' charge model considering the contribution from the escape electrons at null and low electric fields, and reconciles with Birks' model prediction at higher fields. Deviations from current Birks' model are observed for LArTPCs operating at low $\mathcal{E}$ and for heavily ionizing particles. The LArQL model presents a satisfactory description at $dE/dx$ and field ranges for interacting particles in LArTPCs and fits well the available data. Improvements via data sets compilation and global fits are also interesting features of the model.
Explore the source record for details and available documents.
We find that it is possible to increase sensitivity to low energy physics in a third or fourth DUNE-like module with careful controls over radiopurity and some modifications to a detector similar to the DUNE Far Detector design. In particular, sensitivity to supernova and solar neutrinos can be enhanced with improved MeV-scale reach. A neutrinoless double beta decay search with $^{136}$Xe loading appears feasible. Furthermore, sensitivity to Weakly-Interacting Massive Particle (WIMP) Dark Matter (DM) becomes competitive with the planned world program in such a detector, offering a unique seasonal variation detection that is characteristic for the nature of WIMPs.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, 39Ar, a ß emitter of cosmogenic origin. For large detectors, the atmospheric 39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of 39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of 39Ar with respect to AAr by a factor larger than 1400. Assessing the 39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly ?-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.
The next-generation neutrino experiment, DUNE, will utilize a high-intensity neutrino beam produced to measure electron-neutrino appearance and muon-neutrino disappearance with its 40 kilotons (fiducial mass) liquid argon far detector. Liquid argon purity is crucial to use liquid argon time projection chambers (LArTPC) in DUNE’s large detectors. A purity monitor is a miniature TPC that measures the lifetime of photoelectrons generated by its UV-illuminated gold photocathode to measure the purity of liquid argon. ProtoDUNEs are full-scale DUNE prototype LArTPCs built at CERNand perform beam tests. The following will discuss the design, implementation, and results of liquid argon purity monitors deployed in ProtoDUNE.
The Sanford Underground Research Facility (SURF) will host the Far Detector of the Deep Underground Neutrino Experiment (DUNE), an international multi-kiloton Long-Baseline neutrino experiment that will be installed about one and a half kilometers underground in Lead, SD. Detectors will be located inside four cryostats filled with almost 70,000 metric tons of ultrapure liquid argon, with a level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The cryogenics infrastructure supporting this experiment is provided by the Long-Baseline Neutrino Facility (LBNF). This contribution presents modes of operation, layout, and main features of the LBNF Far Site cryogenic system, which is composed of three subsystems: Infrastructure, Proximity, and Internal cryogenics. The Infrastructure cryogenics supports the needs of the cryostat and Proximity cryogenics. It includes the equipment to receive the argon in liquid phase, vaporize it and transfer it underground as a gas, the nitrogen system (composed of the refrigeration system, liquid nitrogen buffer tanks and liquid and gaseous nitrogen distribution), liquid and gaseous argon distribution and process controls. The Proximity cryogenics receives fluids from the Infrastructure cryogenics and delivers them to the Internal cryogenics at the required temperature, pressure, purity and mass flow rate. It includes the argon condensers, liquid and gaseous argon purification and regeneration systems, nitrogen and argon phase separators, piping, valves, and instrumentation. The Internal cryogenics comprises the liquid and gaseous argon distribution inside the cryostats for the commissioning, cool down, fill, and steady state operations of the cryostats and detectors. An international engineering team is designing these systems and will manufacture, install, commission, and qualify them. This contribution describes the main features, performance, functional requirements, and modes of operation of the LBNF Far Site cryogenics system. It also presents the status of the design, along with present and future needs to support the DUNE experiment.
The movable temperature profiler is a 7 m vertical array of 24 sensors that measures cryogenic temperatures with a precision of a few mK. This precision is necessary to monitor the efficiency of re-circulation and purification of liquid-argon inside large liquid-argon based neutrino detectors. Liquid argon temperature impacts electron (signal) drift velocity, flow, purity distribution and thus the overall energy calibration. The temperature profiler is motorized and moves vertically, while in the detector, and cross-calibrates neighboring sensors. The temperature offsets between each sensor cancel the effects of electromagnetic noise. This poster reports on the temperature measurements and such in-situ cross-calibrations at ProtoDUNE (single phase) at CERN.}
The ProtoDUNE Single-Phase Liquid Argon Time Projection Chamber \\ (ProtoDUNE-SP LArTPC) is a prototype for the Deep Underground Neutrino Experiment (DUNE), a future long-baseline neutrino oscillation experiment. Based at the CERN Neutrino Platform, ProtoDUNE-SP LArTPC collected data from a charged test beam in the fall of 2018. It then took data of cosmic-ray muons from November 2018 to the summer of 2020. The main goals of the prototype were to measure parameters related to charged particle passage in argon and evaluate the performance of the detector to inform future DUNE Far Detector development. The test beam provided kaons, pions, muons, protons, and electrons to the detector. These particles represent common final state particles in neutrino interactions, therefore providing information to DUNE on modeling charged particles in argon for its neutrino physics program. In addition to neutrino physics, DUNE has proposed an analysis using the DUNE Far Detector module to set limits for proton decay through the decay channel $p\rightarrow K^++\bar{\nu}$. This measurement would require information on kaons in argon, providing ProtoDUNE-SP LArTPC another opportunity to aid DUNE. This thesis describes the calibration of ProtoDUNE-SP and its detector performance, which serves as a benchmark for the performance of the DUNE Far Detector modules. A specific calibration highlighted is the evaluation of the liquid argon purity in the detector. These measurements use cosmic-ray muons reconstructed in the detector that are calibrated and matched to data from scintillator strips external to the TPC, known as the Cosmic Ray Tagger (CRT). The thesis will discuss the algorithms to match the data between the ProtoDUNE-SP LArTPC and the CRT and discuss the liquid argon purity measurements using one of the algorithms. Data sets of calibrated tracks measured the liquid argon contamination as consistently below 100 ppt oxygen equivalent. After these discussions on the ProtoDUNE-SP LArTPC detector, the thesis will present an evaluation of the inclusive inelastic, sometimes referred to as a reactive, cross section on argon of kaons from the ProtoDUNE-SP test beam with an average momentum of 6 GeV/c.
Scintillation light analysis in liquid argon based neutrino detectors is restrained in capability due to uncertainty in fundamental constants critical to the analysis process. One such property is the Rayleigh scattering length of liquid argon. In the fall of 2023, the TallBo cryostat, located in the Noble Liquid Testing Facility (NLTF) at Fermilab, was used to study the scattering length of liquid argon in the Liquid Argon Scattering (LArS) experiment. Due to systematic errors unknown during measurement analysis, LArS s measurements were quite uncertain. By simulating the LArS experiment, we found that the downturn in detector count rate as a function of liquid argon height at low heights was caused by a misplaced silicon photo multiplier (SiPM). With concentrated effort, we may be able to successfully correct this effect by understanding the relationship between the specified Rayleigh scattering length and the measured attenuation length. With this information and further progression in analysis, we may be able to extract corrected measurements from the LArS data and attain a tangible experimental measurement of the scattering length of liquid argon.