Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linear power flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

PyAMG: Algebraic Multigrid Solvers in Python

PyAMG is a Python package of algebraic multigrid (AMG) solvers and supporting tools for approximating the solution to large, sparse linear systems of algebraic equations, Ax = b, where A is an n × n sparse matrix. Sparse linear systems arise in a range of problems in science, from fluid flows to solid mechanics to data analysis. While the direct solvers available in SciPy’s sparse linear algebra package (scipy.sparse.linalg) are highly efficient, in many cases iterative methods are preferred due to overall complexity. However, the iterative methods in SciPy, such as CG and GMRES, often require an efficient preconditioner in order to achieve a lower complexity. Preconditioning is a powerful tool whereby the conditioning of the linear system and convergence rate of the iterative method are both dramatically improved. PyAMG constructs multigrid solvers for use as a preconditioner in this setting. A summary of multigrid and algebraic multigrid solvers can be found in Olson (2015a), in Olson (2015b), and in Falgout (2006); a detailed description can be found in Briggs et al. (2000) and Trottenberg et al. (2001).

97 MATHEMATICS AND COMPUTING↗

Analyzing Impact of Distributed PV Generation on Integrated Transmission & Distribution System Voltage Stability—A Graph Trace Analysis Based Approach

The use of a Graph Trace Analysis (GTA)-based power flow for analyzing the voltage stability of integrated Transmission and Distribution (T&D) networks is discussed in the context of distributed Photovoltaic (PV) generation. The voltage stability of lines and the load carrying capability of buses is analyzed at various PV penetration levels. It is shown that as the PV generation levels increase, an increase in the steady state voltage stability of the system is observed. Moreover, within certain regions of stability margin changes, changes in voltage stability margins of transmission lines are shown to be linearly related to changes in the loading of the lines. Two case studies are presented, where one case study involves a model with eight voltage levels and 784,000 nodes. In one case study, a voltage-stability heat map is used to demonstrate the identification of weak lines and buses.

14 SOLAR ENERGY↗

Dark Energy Survey Year 3 results: Simulation-based 𝑤CDM inference from weak lensing and galaxy clustering maps with deep learning: Analysis design

Data-driven approaches using deep learning are emerging as powerful techniques to extract non-Gaussian information from cosmological large-scale structure. Here, this work presents the first simulation-based inference (SBI) pipeline that combines weak lensing and galaxy clustering maps in a realistic Dark Energy Survey Year 3 (DES Y3) configuration and serves as preparation for a forthcoming analysis of the survey data. We develop a scalable forward model based on the CosmoGridV1 suite of N-body simulations to generate over one million self-consistent mock realizations of DES Y3 at the map level. Leveraging this large dataset, we train deep graph convolutional neural networks on the full survey footprint in spherical geometry to learn low-dimensional features that approximately maximize mutual information with target parameters. These learned compressions enable neural density estimation of the implicit likelihood via normalizing flows in a ten-dimensional parameter space spanning cosmological 𝑤CDM, intrinsic alignment, and linear galaxy bias parameters, while marginalizing over baryonic, photometric redshift, and shear bias nuisances. To ensure robustness, we extensively validate our inference pipeline using synthetic observations derived from both systematic contaminations in our forward model and independent Buzzard galaxy catalogs. Our forecasts yield significant improvements in cosmological parameter constraints, achieving 2−3× higher figures of merit in the 𝛺 𝑚 − 𝑆 8 plane relative to our implementation of baseline two-point statistics and effectively breaking parameter degeneracies through probe combination. These results demonstrate the potential of SBI analyses powered by deep learning for upcoming Stage-IV wide-field imaging surveys.

Thomsen, A. [Zurich, ETH] (ORCID:0000000203099021)↗

Resolution requirements for energy conservation in kinetic plasma simulations

The kinetic codes used to model the coupled dynamics of electromagnetic fields and charged particle transport have requirements for spatial, temporal, and charge resolution. These requirements may vary by the solution technique and scope of the problem. In this report, we investigate the resolution limits in the energy-conserving implicit particle-in-cell code CHICAGO. This report has the narrow aim of determining the maximum acceptable grid spacing for the dense plasmas generated in models of z-pinch target gases and power-flow electrode plasmas. In the 2D sample problem, the plasma drifts without external forces with velocity of 10 cm/µs. Simulations are scaled by plasma density to maintain uniform strides across the plasma and from the plasma to the boundaries. Additionally, the cloud-in-cell technique is used with 400 particles per cell and Δ t = 0.85× the Courant limit. For the linear cloud distribution, the criterion for conserving energy is Δ E/E tot < 0.01 for 50,000 time steps. The grid resolution is determined to crudely be Δx ≲ 3 l s , where l s is the electron collisionless skin depth. For the second-order cloud distribution the criterion is Δ E/E tot < 0.005 yielding Δx ≤ 15 l s . These scalings are functions of the chosen v d , Δ t , particles-per-cell, and number of steps.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Supporting ARPA-E Power Grid Optimization (Final Report)

Pacific Northwest National Laboratory (PNNL), Arizona State University (ASU), Georgia Institute of Technology (Georgia Tech), Los Alamos National Laboratory (LANL), National Renewable Energy Laboratory (NREL), Texas A&M University (TAMU), The University of Texas at Austin (UT), and the University of Wisconsin-Madison (UW-M) supported the ARPA-E Grid Optimization (GO) Competition by providing a common problem formulation, data format, datasets, evaluation mechanism, scoring, rules, and results that resulted in the awarding of $\$9.24$ million dollars to teams from academia, industry, and national labs for solving three sets of increasingly difficult non-linear, security- constrained AC Optimal Powerflow (AC-OPF) optimization problems in order to increase the efficiency of the US Electric Grid. It is estimated that a 1% increase in efficiency can save $\$1$ billion. Current industry practices typically use a linear DC model (DC-OPF) in order solve the OPF problem within the time constraints of the operation schedule. The GO Competition challenges the best power engineers, mathematicians, and computer scientists to make possible operational decisions based on accurate physical models. To accomplish this, the GO Competition created a series of Challenges and funded teams to produce the best solver. Challenge 1 was to solve the security constrained Alternating Current Optimal Power Flow (ACOPF) problem. Challenge 2 extended that to by adding adjustable transformer tap ratios, phase shifting transformers, switchable shunts, price-responsive demand, ramp rate constrained generators and loads, and fast-start unit commitment (UC). Furthermore, Challenge 2 was a maximization problem while Challenge 1 was a minimization problem. While Challenge 3 was being developed, the entrants were invited to find better solutions to the Challenge 2 synthetic datasets with no restrictions on time, hardware, or algorithms. The Challenge 2 solutions turned out to be very good. Challenge 3 expanded the Challenge 2 problem further by using multiperiod dynamic markets, including advisory models for extreme weather events, day-ahead markets, and the real-time markets with an extended look-ahead. These problems included active bid-in demand and topology optimization. Together the Challenges used nearly 30 million CPU hours. Since each team was working on the same problem, using the same data, and running on the same hardware, fair comparisons could be drawn as to the best solver. The datasets were varied enough, however, that the best solver for one dataset was not necessarily the best at another, so cumulative scores were used. The process was managed by the PNNL maintained website https://GOCompetition.energy.gov, where Entrants could find information about the problem, the data, the rules, submit their solver for evaluation, and see the scores of all the competing teams on a Leaderboard. Interest was world-wide but only American teams were eligible for prizes. The Competition has produced 34 journal articles 115 papers and been cited over 500 times in the literature, including 12 dissertations (4 from foreign countries; Columbia (2), Germany, and Italy) and 3 from the DOE ExaScale project. Software developed by Pearl Street Technologies for Challenges 1 and 2 is now deployed by Southwest Power Pool (SPP) and Midcontinent Independent Service Operator (MISO). Other teams have received inquiries from venture capitalists. Google DeepMind has thanked the Competition for making the datasets developed for the Competition public. They are using it to train machine learning models. The larger datasets have billions of unknowns to be solved for, but only a small percent matter in the final solution. Knowing what unknowns are important can dramatically speedup the solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of modular analytical wake models to the Lillgrund wind plant

Efficient and accurate wake models are required for wind plant performance modeling and the suite of engineering processes that support wind plant layout, control, and monitoring. Although many analytical and engineering wake models with low computational costs have been proposed, their ability to represent the power production of large wind plants in a wide range of atmospheric conditions is not completely understood. The following validation study reviews the underlying theory for analytical wake models, outlines quality control procedures for observational data, and compares model results with observational data from the Lillgrund Wind Plant. Lillgrund makes a valuable case study for wake modeling because of its regular arrangement and the relatively close spacing of constituent wind turbines, which lead to regular and significant wake interactions within the wind plant and the development of deep array flow conditions. Formulations for the velocity deficit, wake-added turbulence, and wake superposition methods are considered in a modular sense, yielding many possible configurations to represent wind turbine wakes, of which seven are examined in detail. Velocity deficit models that account for flow conditions in the near wake are better able to reproduce power production for wind turbines in the transitional region of the wind plant, where wind turbines experience as many as five wakes from upstream turbines. Finally, in the deep array, where power production reaches asymptotic values and wake statistics become quasi-periodic, wake superposition schemes become the largest driver in error reduction; using the linear or maximum wake superposition methods can reduce the relative root mean square error by as much as 40% in the deep array.

17 WIND ENERGY↗

A New Proposal Generalized Predictive Control Algorithm With Polynomial Reference Tracking Applied for Sodium Fast Reactors

This paper proposes a generalized predictive control (GPC) with constraints and orthonormal Laguerre functions using the simplified model of the primary system (reactor core and intermediate heat exchanger (IHX)) of a prototypical sodium fast reactor (SFR). This paper develops a multiple-input multiple-output (MIMO) GPC with input constraints able to track polynomial references of any degree applied in coolant temperature difference across the core and fractional power. The manipulated variables of the GPC-SFR are the reactivity and the sodium flow rate of the primary and secondary pipes. Moreover, orthonormal Laguerre functions and step down condition number techniques were also applied to avoid the numerical ill-conditioning issue in quadratic programming of large systems. Thus, a GPC type-2 was designed to control fractional power, coolant temperature difference across the core and sodium tank temperature of the SFR primary system when temperature references change according to a linear ramp after reaching their steady-state operation, sustaining 100% power operation on the reactor. In order to analyze the load tracking capability of the GPC-SFR type-2, the load following from 100% fractional power (FP) to 60% FP at 0.8% FP/min rate is simulated. Constraints on the rate of coolant temperature difference across the core and reactivity were applied for the design safety. For comparison criteria, this paper compares the GPC-SFR type-2 with the GPC-SFR type-1, i.e., standard model predictive control (MPC), to verify the viability and superior performance of the proposal regarding: (a) ramp-tracking capability of temperature and load; (b) the rejections of a reactivity disturbance of -1 cent and a secondary sodium inlet temperature disturbance of +10°F; and (c) a simulation with uncertainty in reactor design. The simulations show that the GPC-SFR type-2 overcome the GPC-SFR type-1 robustness and performance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scaling Analysis of Two–Phase Flow in Fractal Permeability Fields

Fluid mixing in permeable media is essential in many practical applications. The mixing process is a consequence of velocity fluctuations owing to geological heterogeneities and mobility contrast of fluids. Heterogeneities in natural rocks are often spatially correlated, and their properties, such as permeability, may be described using fractal distributions. This work models the fractal characteristics of such permeability fields in which the covariance function is expressed as a power-law function. A generalized scaling relation is derived relating various fractal permeability fields using the magnitude of their fluctuations. Here, this relation reveals the self-similar behavior of two-phase flow in such permeable media. To that end, a recently developed, high-resolution numerical simulator is employed to validate the analytically derived scaling relations. Two flow problems are considered in which flow is governed by 1) a linear, and 2) a nonlinear transport equation. Due to the probabilistic representation of the fractal permeability fields, a sensitivity study is conducted for each flow scenario to determine the number of realizations required for statistical convergence. Scaling analysis is performed using ensemble averages of simulated saturation profiles and their mixing lengths. Results support the validity of the developed scaling relation across the range of investigated flow conditions at intermediate times. The dynamics of linear flow in the asymptotic regime is affected by the correlation structure of heterogeneity. In nonlinear flow, scaling behavior appears to be dominated by the degree of nonlinearity.

58 GEOSCIENCES↗

LCLS-II Helium Refrigeration System Commissioning Results

SLAC National Accelerator Laboratory has upgraded to LCLS-II, featuring a 4 GeV superconducting linear accelerator composed of 37 cryomodules and two large helium refrigeration systems with a cooling capacity of 4 kW at 2.0 K. The LCLS-II Helium Refrigeration System (HRS) consists of two compressor stations, each with a power of approximately 4.5 MW, two 4.5 K cold boxes, each with a power of 18 kW equivalent at 4.5 K, and two sets of cold compressors that can each produce a flow of 230 g/s at 31 mbar (2.0K). Performance tests of the HRS were meticulously planned and successfully carried out, with results demonstrating that it exceeded the process requirements for LCLS-II operations. This paper provides a detailed presentation of the LCLS-II HRS performance and the challenges encountered during the commissioning phase.

42 ENGINEERING↗

Ocean Energy Systems Wave Energy Modeling Task 10.4: Numerical Modeling of a Fixed Oscillating Water Column

This paper reports on an ongoing international effort to establish guidelines for numerical modeling of wave energy converters, initiated by the International Energy Agency Technology Collaboration Program for Ocean Energy Systems. Initial results for point absorbers were presented in previous work, and here we present results for a breakwater-mounted Oscillating Water Column (OWC) device. The experimental model is at scale 1:4 relative to a full-scale installation in a water depth of 12.8 m. The power-extracting air turbine is modeled by an orifice plate of 1–2% of the internal chamber surface area. Measurements of chamber surface elevation, air flow through the orifice, and pressure difference across the orifice are compared with numerical calculations using both weakly-nonlinear potential flow theory and computational fluid dynamics. Both compressible- and incompressible-flow models are considered, and the effects of air compressibility are found to have a significant influence on the motion of the internal chamber surface. Recommendations are made for reducing uncertainties in future experimental campaigns, which are critical to enable firm conclusions to be drawn about the relative accuracy of the numerical models. It is well-known that boundary element method solutions of the linear potential flow problem (e.g., WAMIT) are singular at infinite frequency when panels are placed directly on the free surface. This is problematic for time-domain solutions where the value of the added mass matrix at infinite frequency is critical, especially for OWC chambers, which are modeled by zero-mass elements on the free surface. A straightforward rational procedure is described to replace ad-hoc solutions to this problem that have been proposed in the literature.

16 TIDAL AND WAVE POWER↗

ExaWind: Predictive Wind Energy Simulations

This presentation describes the ExaWind project and the team's progress in creating a suite of performance-portable codes designed for predictive simulations of wind farms on next-generation exascale-class supercomputers. Such simulations will require the resolution of scales spanning many orders of magnitude, from blade boundary layers to wind farm flow structures. In the U.S., the first exascale systems will be GPU accelerated, and different GPU manufacturers have been chosen for the different systems. At the heart of the ExaWind software is a hybrid-solver approach based on the codes Nalu-Wind and AMR-Wind, which are computational fluid dynamics solvers for the incompressible Navier-Stokes equations. Nalu-Wind is an unstructured-grid code used to resolve wind turbine geometry and blade boundary layers, whereas AMR-Wind is a structured-grid background solver for atmospheric turbulent flow and turbine wake propagation. The models are coupled with overset meshes and global linear systems are approximated through a loose-coupling algorithm. Results will include validation-quality high-fidelity simulations and strong/weak scaling results from the Summit supercomputer.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Performance evaluation of a Terry GS-2 steam impulse turbine with air-water mixtures

Terry steam turbines are widely used in various industries because of their robust design. Within the nuclear power generation industry, they are used in the Reactor Core Isolation Cooling System to remove decay heat during reactor isolation events. During the Fukushima Daiichi nuclear power station disaster in Japan in 2011, the Reactor Core Isolation Cooling System and associated Terry turbine operated for over 70 hours in Unit 2; this runtime is well beyond the expected operating duration. Theories suggest the turbine was subjected to a two-phase inlet flow, which could degrade the turbine performance. In this work, an experimental test rig was constructed to test a full-scale Terry model GS-2 steam turbine under two-phase air/water flows. Steady-state efficiency and torque performance maps of the turbine were developed over a range of turbine inlet pressures (1.38–4.83 bar or 20–70 psia), air mass fractions (0.05–1.0) and rotational speeds up to 4000 RPM. Furthermore, turbine performance followed expected trends with torque varying linearly and efficiency varying quadratically with rotational speed. In addition, high-speed images of the two-phase flow entering the turbine were also analyzed to understand how changes in inlet pressure and air mass fraction affect the flow regime and homogenization. The present tests with air–water two-phase mixtures are an important step towards providing an understanding of the full-scale Terry turbine’s behavior and performance curves under two-phase conditions. The results of this work will be combined with air/water and steam/water data gathered using a small-scale Terry ZS-1 steam turbine in order to understand the scaling relationship between large and small size Terry turbines and fluid pairs. The combined data set will enable further development of analytical models over a wide range of conditions and may be used to provide technical justification for expanded use of the Terry turbines in nuclear power plant safety systems and other systems.

42 ENGINEERING↗

Self‐Propelling Macroscale Sheets Powered by Enzyme Pumps

Nanoscale enzymes anchored to surfaces act as chemical pumps by converting chemical energy released from enzymatic reactions into spontaneous fluid flow that propels entrained nano‐ and microparticles. Enzymatic pumps are biocompatible, highly selective, and display unique substrate specificity. Utilizing these pumps to trigger self‐propelled motion on the macroscale has, however, constituted a significant challenge and thus prevented their adaptation in macroscopic fluidic devices and soft robotics. Using experiments and simulations, we herein show that enzymatic pumps can drive centimeter‐scale polymer sheets along directed linear paths and rotational trajectories. In these studies, the sheets are confined to the air/water interface. With the addition of appropriate substrate, the asymmetric enzymatic coating on the sheets induces chemically driven, buoyancy flows that controllably propel the sheet's motion on the air/water interface. The directionality and speed of the motion can be tailored by changing the pattern of the enzymatic coating, type of enzyme, and nature and concentration of the substrate. This work highlights the utility of biocompatible enzymes for generating motion in macroscale fluidic devices and robotics and indicates their potential utility for in vivo applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying CTFE content in FK-800 using ATR-FTIR and time to peak crystallization

The chlorotrifluoroethylene (CTFE) content in vinylidene fluoride (VDF)-CTFE copolymers greatly influences the chemical and physical properties and ultimately determines the application. The copolymer known as FK-800 has a VDF:CTFE ratio of ~1:3 and is used almost exclusively as the binder in the insensitive high explosive (HE) formulation PBX 9502. Due to the dangerous nature of HE work and the effect CTFE content variations have, the ability to quickly and easily quantify CTFE content is of interest. Two techniques, attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) and time to peak crystallization measured by heat flow calorimetry, were evaluated here as potential means for quantifying CTFE content. Based on the certificate of analyses (COAs), FK-800 lots with varied CTFE content encompassing the range historically used in HE applications were used as standards for both methodologies. For FTIR, a linear regression was performed on the peak area of the C-Cl IR stretch and the CTFE content; the methodology was then demonstrated on four samples, two lots of unadulterated material and material recovered from two HE samples. The calculated CTFE content and COAs were in good agreement for all four samples. Heat flow calorimetry revealed the relationship between time to peak crystallization and CTFE content was best fit by a power regression; the methodology was then tested on two different FK-800 lots. Only one sample showed good agreement between the calculated CTFE content and the COA. This discrepancy indicates the method developed is not suitable for quantifying CTFE, but provides valuable insight regarding the crystallization behavior of VDF-CTFE copolymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self‐Propelling Macroscale Sheets Powered by Enzyme Pumps

Abstract Nanoscale enzymes anchored to surfaces act as chemical pumps by converting chemical energy released from enzymatic reactions into spontaneous fluid flow that propels entrained nano‐ and microparticles. Enzymatic pumps are biocompatible, highly selective, and display unique substrate specificity. Utilizing these pumps to trigger self‐propelled motion on the macroscale has, however, constituted a significant challenge and thus prevented their adaptation in macroscopic fluidic devices and soft robotics. Using experiments and simulations, we herein show that enzymatic pumps can drive centimeter‐scale polymer sheets along directed linear paths and rotational trajectories. In these studies, the sheets are confined to the air/water interface. With the addition of appropriate substrate, the asymmetric enzymatic coating on the sheets induces chemically driven, buoyancy flows that controllably propel the sheet's motion on the air/water interface. The directionality and speed of the motion can be tailored by changing the pattern of the enzymatic coating, type of enzyme, and nature and concentration of the substrate. This work highlights the utility of biocompatible enzymes for generating motion in macroscale fluidic devices and robotics and indicates their potential utility for in vivo applications.

Song, Jiaqi↗

Fast Modular Reactor Nuclear Design Parameters of Fuel Cycle and Power Distributions

This paper describes conceptual design of a 112 MW thermal (50 MW electric) Fast Modular Reactor (FMR) system operating at 7 MPa with inlet/outlet temperatures of 509/800 ºC. The reactor system includes the reactor core, fuel assemblies, fuel rods, reactor internals, reflector, neutron control system, flow control, and structural components. The nuclear design and analysis were conducted to search for a baseline core with a cycle length greater than 8-year and the power peaking factor less than 1.5 by adjusting the fuel assembly, reactor core, and reflector configurations. The neutronics calculations of the baseline core showed that a refueling interval of 9-year is achieved with a total peaking factor of 1.47 and a fuel rod average linear power of 3.6 kW/m.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cooperative Transmission Expansion Planning Experiment Data and Results

GO WEST is an open-source power grid modeling framework for U.S. Western Interconnection, which allows users to tailor the model depending on their research study and science questions. It covers 28 balancing authorities (BA) and 12 states in U.S. Western Interconnection. GO WEST allows users to select different number of nodes and come up with a simplified network by utilizing 10,000 nodal topology of U.S. Western Interconnection created by Texas A&M University. Users can try and select different number of nodes, mathematical formulations (linear programming vs. mixed-integer linear programming), transmission line limit scaling factors, and hurdle rate scaling factors. GO WEST offers a unit commitment and economic dispatch (UC/ED) module to simulate grid operations on an hourly scale. In this sense, users can calibrate and validate their model versions by comparing model outputs to historical datasets. TEP is an open-source transmission capacity expansion model, built on GO WEST framework. It utilizes linear programming to optimize transmission capacity addition investment on existing lines within GO WEST framework. In this sense, TEP model only increases the thermal capacity of existing transmission lines and does not add new lines to the system, which leaves the topology preserved. TEP minimizes the total cost of the system which comprises the operational cost of satisfying electricity demand (i.e., generation cost), cost of loss of load (i.e., unserved energy), cost of power flow, and cost of new transmission capacity additions (i.e., investment cost). In order to use TEP model, users need to create scenarios with GO WEST framework. In this analysis, outputs from several models are used to create future inputs to GO WEST and TEP models, including GCAM-USA, TELL, CERF and reV. This dataset includes experiment inputs and outputs from three different transmission expansion scenarios (cooperative, intermediate, and individual) for 2019 and 2059. For 2019, a base scenario to illustrate the default (i.e., historical) power grid operations is also included. This study utilizes rcp45hotter_ssp3 scenario from a previous version of GCAM-USA simulations. Sources of the shapefiles in supplementary data are HIFLD Open and U.S. Energy Atlas. Please see the README file for a detailed description of the main and supplementary data.

Capacity Expansion Model↗

Fast modular reactor nuclear design parameters of fuel cycle and power distributions

This paper describes conceptual design of a 112 MW thermal (50 MW electric) Fast Modular Reactor (FMR) system operating at 7 MPa with inlet/outlet temperatures of 509/800 Celsius degrees. The reactor system includes the reactor core, fuel assemblies, fuel rods, reactor internals, reflector, neutron control system, flow control, and structural components. The nuclear design and analysis were conducted to search for a baseline core with a cycle length greater than 8-year and the power peaking factor less than 1.5 by adjusting the fuel assembly, reactor core, and reflector configurations. The neutron transport calculations of the baseline core showed that a refueling interval of 9-year is achieved with a total peaking factor of 1.47 and a fuel rod average linear power of 3.6 kW/m. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗