At least 181 records · Page 10

Laser Drilling Development Trial Final Report CRADA No. TSB-1538-98

This project performed various laser drilling tests to demonstrate femtosecond laser drilling of fuel injector nozzles with minimal recast, minimal heat affected zone and no collateral damage. LLNL had extensive experience in ultra short-pulse laser systems and developed specialized hardware for these applications.

36 MATERIALS SCIENCE↗

AlGaAs heterojunction lasers

The characterization of 8300 A lasers was broadened, especially in the area of beam quality. Modulation rates up to 2 Gbit/sec at output powers of 20 mW were observed, waveform fidelity was fully adequate for low BER data transmission, and wavefront measurements showed that phase aberrations were less than lamda/50. Also, individually addressable arrays of up to ten contiguous diode lasers were fabricated and tested. Each laser operates at powers up to 30 mW CW in single spatial mode. Shifting the operating wavelength of the basic CSP laser from 8300 A to 8650 A was accomplished by the addition of Si to the active region. Output power has reached 100 mW single mode, with excellent far field wave front properties. Operating life is currently approx. 1000 hrs at 35 mW CW. In addition, laser reliability, for operation at both 8300 A and 8650 A, has profited significantly from several developments in the processing procedures.

Goldstein, B.↗

Optical scanning system for laser velocimeter

Tests, using towed models of large aircraft with small trailing models through still-air test zone, have been designed to analyze wake vortex phenomena. Analyzing velocity profiles as function of time, information is developed on generation and decay of wake vortex. System is improvement over laser velocimeter (LV) products and is anticipated to have many applications in research and commercial products.

Rhodes, D. B.↗

Support of Adhesion Mechanisms in Al 2 O 3 Aerosol Deposition Through Laser-Induced Particle Impact Testing

Aerosol deposition (AD) is a kinetic spray process capable of depositing ceramic coatings at room temperature, but AD process development is generally a laborious exploration of a large process parameter space. Here, this paper presents a case study investigating whether laser-induced particle impact testing (LIPIT) could be applied to expedite development of an alumina (Al 2 O 3 ) coating on nickel (Ni): Specifically, whether LIPIT measurements could predict critical velocities of adhesion on Ni and Al 2 O 3 , and the effect of ball milling the Al 2 O 3 powder. Because LIPIT has a diffraction-limited lower bound on imageable particle size, the usefulness of Al 2 O 3 powder agglomerates as a proxy for single particles was additionally studied. Overall, LIPIT measurements and AD sprays agreed that ball milling dramatically improves adhesion. Additionally, LIPIT measurements of critical velocity of adhesion of Al 2 O 3 powder agglomerates on Ni and Al 2 O 3 substrates (150 meters per second [m/s] and 250 m/s, respectively) quantitatively agreed with predictions from a previously published model based on picoindentation and molecular dynamics simulations. Together, these findings support the established hypothesis that Al 2 O 3 adheres via a dislocation-mediated mechanism in AD, that Al 2 O 3 powder agglomerates adhere as individual constituent particles rather than collectively, and that, for this case study, LIPIT measurements were predictive of AD process parameters.

Al2O3↗

Integrated Laser Characterization, Data Acquisition, and Command and Control Test System

Satellite-based laser technology has been developed for topographical measurements of the Earth and of other planets. Lasers for such missions must be highly efficient and stable over long periods in the temperature variations of orbit. In this innovation, LabVIEW is used on an Apple Macintosh to acquire and analyze images of the laser beam as it exits the laser cavity to evaluate the laser s performance over time, and to monitor and control the environmental conditions under which the laser is tested. One computer attached to multiple cameras and instruments running LabVIEW-based software replaces a conglomeration of computers and software packages, saving hours in maintenance and data analysis, and making very longterm tests possible. This all-in-one system was written primarily using LabVIEW for Mac OS X, which allows the combining of data from multiple RS-232, USB, and Ethernet instruments for comprehensive laser analysis and control. The system acquires data from CCDs (charge coupled devices), power meters, thermistors, and oscilloscopes over a controllable period of time. This data is saved to an html file that can be accessed later from a variety of data analysis programs. Also, through the LabVIEW interface, engineers can easily control laser input parameters such as current, pulse width, chiller temperature, and repetition rates. All of these parameters can be adapted and cycled over a period of time.

Stysley, Paul↗

Construction and testing of a Scanning Laser Radar (SLR), phase 2

The scanning laser radar overall system is described. Block diagrams and photographs of the hardware are included with the system description. Detailed descriptions of all the subsystems that make up the scanning laser radar system are included. Block diagrams, photographs, and detailed optical and electronic schematics are used to help describe such subsystem hardware as the laser, beam steerer, receiver optics and detector, control and processing electronics, visual data displays, and the equipment used on the target. Tests were performed on the scanning laser radar to determine its acquisition and tracking performance and to determine its range and angle accuracies while tracking a moving target. The tests and test results are described.

Flom, T.↗

Geoscience Laser Altimetry System (GLAS) Loop Heat Pipe Anomaly and On Orbit Testing

The Geoscience Laser Altimetry System (GLAS) is the sole instrument on the ICESat Satellite. On day 230 of 2003, the GLAS Component Loop Heat Pipe (CLHP) entered a slow circulation mode that resulted in the main electronics box reaching its hot safing temperature, after which the entire instrument was turned off. The CLHP had a propylene working fluid and was actively temperature controlled via a heater on the compensation chamber. The slow circulation mode happened right after a planned propulsive yaw maneuver with the spacecraft. It took several days to recover the CLHP and ensure that it was still operational. The recovery occurred after the entire instrument was cooled to survival temperatures and the CLHP compensation chamber cycled on a survival heater. There are several theories as to why this slow circulation mode exhibited itself, including: accumulation of Non-Condensible Gas (NCG), the secondary wick being under designed or improperly implemented, or an expanded (post-launch) leak across the primary wick. Each of these is discussed in turn, and the secondary wick performance is identified as the most likely source of the anomalous behavior. After the anomaly, the CLHP was controlled to colder temperatures to improve its performance (as the surface tension increases with lower temperature, as does the volume of liquid in the compensation chamber) and only precursor pulses occurred later in the mission. After GLAS s last laser failed, in late 2009, a decision was made to conduct engineering tests of both LHPs to try and duplicate this flight anomaly. The engineering tests consisted of control setpoint changes, sink changes, and one similar propulsive Yaw maneuver. The only test that showed any similar anomaly precursors on the CLHP was the propulsive maneuver followed by a setpoint increase. The ICESat Satellite was placed in a decaying orbit and ended its mission on August 30, 2010 in Barents Sea.

Baker, Charles↗

Testing with the Laser-Enhanced Arc Jet Facility (LEAF) at NASA Ames Research Center

NASA's new Laser-Enhanced Arcjet Facility (LEAF) employs 200 kilowatts of continuous-wave fiber lasers, combined with a 60-megawatt arc plasma jet, to simulate the combined radiative and convective heating is now operational and Orion heat-shield material is undergoing testing. This upgrade to the existing Interaction Heating Facility (IHF) involves the addition of high-power fiber lasers that project 1070nm radiative energy into the existing vacuum chamber. The optically expanded laser beam enters a side window of the test chamber to form either a uniform 150 x 150 mm or a 425 x 425 mm square spot on a wedge-shaped model holder. Combined heating levels of up to 180 W/cm2 convective with either 300 W/cm2 or 100 W/cm2 are achievable. This allows the arc jet and lasers to simulate dynamic entry-heating profiles encountered during entry by the Orion crew capsule for the lunar return conditions. New computational investigations are underway to explore testing with the objective of defining ablative material failure limit. Typical arc-jet testing is performed with test article that are stagnation or wedge geometries. The existing convective heating test facility combined with test article design limits how high a combined shear, heat-flux and pressure conditions can be achieved. With the addition of laser power of 200 kW, much higher combined conditions of high heat-flux, pressure and shear is achievable on a wedge or a swept-cylinder article. Such testing possibilities will allow us to progressively increase the combined conditions and explore when an ablative TPS material may fail. The presentation provides an overview of the LEAF and present results from the on-going Orion Testing.

Venkatapathy, Ethiraj↗

Higher certainty of the laser-induced damage threshold test with a redistributing data treatment

As a consequence of its statistical nature, the measurement of the laser-induced damage threshold holds always risks to over- or underestimate the real threshold value. As one of the established measurement procedures, the results of S-on-1 (and 1-on-1) tests outlined in the corresponding ISO standard 21 254 depend on the amount of data points and their distribution over the fluence scale. With the limited space on a test sample as well as the requirements on test site separation and beam sizes, the amount of data from one test is restricted. This paper reports on a way to treat damage test data in order to reduce the statistical error and therefore measurement uncertainty. Three simple assumptions allow for the assignment of one data point to multiple data bins and therefore virtually increase the available data base.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser anemometer optimization

The design, construction, and testing of laser anemometer configurations for hot section velocity measurements is discussed. The optimization of the laser anemometer systems include the data processing algorithms used. Some relevant hot section properties considered are high temperature with a large background radiation, difficulty of optical access, large flow velocity variations, the presence of solid surfaces that generate reflections and low seed particle density.

Edwards, R. V.↗

Using NASA's Molecular Adsorber Coating Technology During Thermal Vacuum Testing to Protect Critical Laser Flight Optics on the ATLAS Instrument

The Molecular Adsorber Coating (MAC) is a sprayable coatings technology that was developed at NASA Goddard Space Flight Center (GSFC). The coating was designed to address molecular contamination concerns on or near sensitive surfaces and instruments within the spacecraft for flight or ground-based applications in vacuum conditions. This paper will discuss the use of NASA's MAC technology to isolate and protect the critical laser flight optics of the Advanced Topographic Laser Altimeter System (ATLAS) instrument on the Ice, Cloud, and land Elevation Satellite-2 (ICESat-2). MAC was strategically used during thermal vacuum (TVAC) testing efforts to reduce the risk of contaminating the laser optical components from non-baked items and other unknown outgassing sources from the chamber environment. This paper summarizes the design and implementation efforts, and the chemical analysis of the MAC samples that were used during two recent TVAC tests for the ICESat-2/ATLAS mission.

thermal vacuum↗

Using NASA's Molecular Adsorber Coating Technology During Thermal Vacuum Testing to Protect Critical Laser Flight Optics on the ATLAS Instrument

The Molecular Adsorber Coating (MAC) is a sprayable coatings technology that was developed at NASA Goddard Space Flight Center (GSFC). The coating was designed to address molecular contamination concerns on or near sensitive surfaces and instruments within the spacecraft for flight or ground-based applications in vacuum conditions. This paper will discuss the use of NASA's MAC technology to isolate and protect the critical laser flight optics of the Advanced Topographic Laser Altimeter System (ATLAS) instrument on the Ice, Cloud, and land Elevation Satellite-2 (ICESat-2). MAC was strategically used during thermal vacuum (TVAC) testing efforts to reduce the risk of contaminating the laser optical components from non-baked items and other unknown outgassing sources from the chamber environment. This paper summarizes the design and implementation efforts, and the chemical analysis of the MAC samples that were used during two recent TVAC tests for the ICESat-2/ATLAS mission.

molecular adsorber coating↗

Near-ultraviolet absorption annealing in hafnium oxide thin films subjected to continuous-wave laser radiation

Hafnium oxide (HfO 2 ) is the most frequently used high-index material in multilayer thin-film coatings for high-power laser applications ranging from near-infrared to near-ultraviolet (UV). Absorption in this high-index material is also known to be responsible for nanosecond-pulse laser-damage initiation in multilayers. In this work, modification of the near-UV absorption of HfO 2 monolayer films subjected to irradiation by continuouswave (cw), 355-nm or 351-nm laser light focused to produce power densities of the order of ~100 kW/cm 2 is studied. Up to a 70% reduction in absorption is found in the areas subjected to irradiation. Temporal behavior of absorption is characterized by a rapid initial drop on the few-tens-of-seconds time scale, followed by a longerterm decline to a steady-state level. Absorption maps generated by photothermal heterodyne imaging confirm the permanent character of the observed effect. Nanosecond-pulse, 351-nm and 600-fs, 1053-nm laser-damage tests performed on these cw laser–irradiated areas confirm a reduction of absorption by measuring up to 25% higher damage thresholds. We discuss possible mechanisms responsible for near-UV absorption annealing and damage-threshold improvement resulting from irradiation by near-UV cw laser light.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal Vacuum Test of GLAS Propylene Loop Heat Pipe Development Model

This paper presents viewgraphs on Thermal Vacuum Tests of the GLAS (Geoscience Laser Altimeter System) Propylene Loop Heat Pipe Development Model. The topics include: 1) Flight LHP System (Laser); 2) Test Design and Objectives; 3) DM (Development Model) LHP (Loop Heat Pipe) Test Design; 4) Starter Heater and Coupling Blocks; 5) CC Control Heaters and PRT; 6) Heater Plates (Shown in Reflux Mode); 7) Startup Tests; 8) CC Control Heater Power Tests for CC Temperature Control; and 9) Control Temperature Stability.

Baker, Charles↗

Development and qualification testing of a laser-ignited, all-secondary (DDT) detonator

The Indian Head Division, Naval Surface Warfare Center (IHDIV, NSWC) is conducting a qualification program for a laser-ignited, all-secondary (DDT) explosive detonator. This detonator was developed jointly by IHDIV, NSWC and the Department of Energy's EG&G Mound Applied Technologies facility in Miamisburg, Ohio to accept a laser initiation signal and produce a fully developed shock wave output. The detonator performance requirements were established by the on-going IHDIV, NSWC Laser Initiated Transfer Energy Subsystem (LITES) advanced development program. Qualification of the detonator as a component utilizing existing military specifications is the selected approach for this program. The detonator is a deflagration-to-detonator transfer (DDT) device using a secondary explosive, HMX, to generate the required shock wave output. The prototype development and initial system integration tests for the LITES and for the detonator were reported at the 1992 International Pyrotechnics Society Symposium and at the 1992 Survival and Flight Equipment National Symposium. Recent results are presented for the all-fire sensitivity and qualification tests conducted at two different laser initiation pulses.

Blachowski, Thomas J.↗

Optical test unit design for the direct detection laser tranceiver program

The Optical Test Unit (OTU) for the NASA Direct Detection Laser Tranceiver (DDLT) Experiment was designed to perform a wide variety of electrical and optical tests with minimum cost and risk. Choosing instruments that could do their own processing and carefully examining each step of the integration and test sequence helped reduce the cost and complexity of the system, allowing us to meet a very ambitious schedule. For some tests, less elegant schemes can be used than the traditional system test methods, while still maintaining the integrity of the test system. This paper explores the problems encountered and options that were available in designing the system test equipment for this optical communication system.

Reed, Patricia A.↗