Techno-economic and thermodynamic analysis of pre-cooling systems at gaseous hydrogen refueling stations

In this study, we conducted a techno-economic and thermodynamic analysis of precooling units (PCUs) at hydrogen refueling stations and developed a cost-minimizing design algorithm for the PCU observing the SAE J2601 refueling protocol for T40 stations. In so doing, we identified major factors that affect PCU cost and energy use. The hydrogen precooling energy intensity depends strongly on the station utilization rate, but approaches 0.3 kWh e /kg-H 2 at full utilization. In early fuel cell electric vehicle markets where utilization of the refueling capacity is low, the overhead cooling load (to keep the heat exchanger cold at -40°C) results in significantly high PCU energy intensity because only a small amount of hydrogen is being dispensed. We developed a parameterized precooling energy intensity prediction formula as a function of the ambient temperature and station utilization rate. We also found that the Joule-Thomson effect of the flow control device introduces a significant increase in temperature upstream of the PCU’s heat exchanger (HX), which impacts the PCU design capacity. An optimal PCU (per dispenser, at 35°C HX inlet temperature) consists of a 13-kW refrigerator and a HX with 1400 kg of thermal mass (aluminum), which currently costs $70,000 (uninstalled). Finally, the total (installed) capital and operation cost of PCU at a fully utilized hydrogen refueling station adds $0.50/kg-H 2 .

08 HYDROGEN↗

Ultra-high efficiency hydrogen production using a large-scale solid oxide electrolysis cell system

Efficient and cost-effective production of clean hydrogen is key to decarbonizing the production of hard-to-abate industries, such as chemicals, fuels, steel, cement and many other commodities that form the basis of modern societies. High-temperature steam electrolysis (HTSE) has recently become commercially available and offers opportunities for producing hydrogen at higher efficiency and lower cost than competing low temperature technologies. In this work, we report world record setting hydrogen production efficiency from large-scale prototype HTSE systems based on solid oxide electrolysis cell (SOEC) technology. Independent tests performed at Idaho National Laboratory (INL) employed a Bloom Energy 100 kW SOEC system to achieve a hydrogen production direct current specific electric energy consumption as low as 36.7 kWh per kilogram of hydrogen. Remarkably, similar high efficiencies in the range of 36–39 kW/kg-H2 were obtained over a wide range of hydrogen production rates and even during dynamic ramping as the hydrogen production and electric power consumption of the system were varied between 20 % and 100 % of nominal conditions. Furthermore, these test results validate previous projections that commercial SOEC systems can produce clean hydrogen at efficiencies approaching 100 % for less than 2 U S. dollars per kilogram when located near sources of inexpensive, low-grade heat and clean electricity.

08 HYDROGEN↗

Exergy analysis and operational efficiency of a horizontal ground-source heat pump system operated in a low-energy test house simulated occupancy conditions

This paper presents detailed analysis of a water to water ground source heat pump (WW-GSHP) to provide all the hot water needs in a 345 m 2 house located in DOE climate zone 4 (mixed-humid). The protocol for hot water use is based on the Building America Research Benchmark Definition (Hendron 2008; Hendron and Engebrecht 2010) which aims to capture the living habits of the average American household and its impact on energy consumption. The entire house was operated under simulated occupancy conditions. Detailed energy and exergy analysis provides a complete set of information on system efficiency and sources of irreversibility, the main cause of wasted energy. The WW-GSHP was sized at 5.275 kW (1.5-ton) for this house and supplied hot water to a 303 L (80 gal) water storage tank. The WW-GSHP shared the same ground loop with a 7.56 kW (2.1-ton) water to air ground source heat pump (WA-GSHP) which provided space conditioning needs to the entire house. Data, analyses, and measures of performance for the WW-GSHP in this paper complements the results of the WA-GSHP published in this journal (Ally, Munk et al. 2012). Understanding the performance of GSHPs is vital if the ground is to be used as a viable renewable energy resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential energy savings benefits and limitations of radiative cooling coatings for U.S. residential buildings

We report radiative coatings are a promising strategy to implement passive cooling that provides an eco-friendly pathway to achieve energy efficiency in buildings. This study investigates the benefits and limitations of implementing radiative coatings on the building envelope, particularly the roof, of residential buildings in the United States. The analysis compares the performance of an ideal radiative coating with broadband surface properties to a realistic radiative coating with diffuse and semitransparent properties. To enhance the net energy efficiency of buildings, we carried out a comprehensive parametric analysis comprising key radiation surface properties to maximize cooling energy savings while minimizing heating energy penalties. A countrywide assessment for 68 locations across the United States showed that net energy savings are a strong function of the climatic and atmospheric conditions. Broadly, southern locations showed high overall energy savings whereas northern locations exhibited high overall energy penalties. Locations in International Energy Conservation Code (IECC) climate zones 1A, 2A, and 2B showed a net annual energy savings above 5%, whereas locations in IECC climate zones 5B, 6B, and 7 showed a net annual energy penalty greater than 3%. The hot and dry climate of Phoenix, Arizona, showed the highest overall energy savings of 426 kWh (6.2%). Additionally, the mathematical correlation reveals that the net energy savings of a location is positive only when its average cooling degree days is greater than 5.5 or its average heating degree days is less than 10.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rechargeability and economic aspects of alkaline zinc-manganese dioxide cells for electrical storage and load leveling

Batteries based on manganese dioxide (MnO2) cathodes are good candidates for grid-scale electrical energy storage, as MnO2 is low-cost, relatively energy dense, safe, water-compatible, and non-toxic. Alkaline Zn-MnO2 cells, if cycled at reduced depth of discharge (DOD), have been found to achieve substantial cycle life with battery costs projected to be in the range of $100 to 150 per kWh (delivered). Commercialization of rechargeable Zn-MnO2 batteries has in the past been hampered due to poor cycle life. In view of this, the work reported here focuses on the long-term rechargeability of prismatic MnO2 cathodes at reduced DOD when exposed to the effects of Zn anodes and with no additives or specialty materials. Over 3000 cycles is shown to be obtainable at 10% DOD with energy efficiency >80%. The causes of capacity fade during long-term cycling are also investigated and appear to be mainly due to the formation of irreversible manganese oxides in the cathode. Analysis of the data indicates that capacity loss is rapid in the first 250 cycles, followed by a regime of stability that can last for thousands of cycles. A model has been developed that captures the behavior of the cells investigated using measured state of charge (SOC) data as input. An approximate economic analysis is also presented to evaluate the economic viability of Zn-MnO2 batteries based on the experiments reported here. (C) 2014 Elsevier B.V. All rights reserved.

Ingale, ND↗

Cost and energy demand of producing nickel manganese cobalt cathode material for lithium ion batteries

The price of the cathode active materials in lithium ion batteries is a key cost driver and thus significantly impacts consumer adoption of devices that utilize large energy storage contents (e.g. electric vehicles). A process model has been developed and used to study the production process of a common lithium-ion cathode material, lithiated nickel manganese cobalt oxide, using the co-precipitation method. The process was simulated for a plant producing 6500 kg day –1 . The results indicate that the process will consume approximately 4 kWh kg NMC –1 of energy, 15 L kg NMC –1 of process water, and cost $23 to produce a kg of Li-NMC333. The calculations were extended to compare the production cost using two co-precipitation reactions (with Na 2 CO 3 and NaOH), and similar cathode active materials such as lithium manganese oxide and lithium nickel cobalt aluminum oxide. Finally, a combination of cost saving opportunities show the possibility to reduce the cost of the cathode material by 19%.

25 ENERGY STORAGE↗

Cost of automotive lithium-ion batteries operating at high upper cutoff voltages

Here, the potential for operating automotive battery packs at high upper cutoff voltages (UCV) has been explored using preliminary data on eight cathode materials. The pack level energy density, specific energy, and battery cost are calculated using the spreadsheet tool BatPaC. The tool used experimental data for some cathode materials such as the lithiated oxides of nickel manganese cobalt (NMC), nickel cobalt aluminum (NCA), layered lithium- and manganese-rich nickel manganese cobalt (LMRNMC). The half-cell data were obtained at UCVs between 4.2 and 4.7 V vs. Li/Li + . The experimental data showed LMRNMC with the highest lithiation capacity gain, increasing from 176 mAh·g –1 at 4.2 V to 260 mAh·g –1 at 4.7 V; this advantage is partly offset by its lower average voltage. Assuming optimized cell materials/design and an area-specific impedance of 12 Ω•cm 2 for all the materials, the BatPaC results indicate that the specific energies or energy densities of the battery electric vehicle (BEV) and plug-in hybrid electric vehicle (PHEV) battery packs with the LMRNMC and NMC cathodes can exceed 180 (BEV) and 160 (PHEV) Wh·kg –1 at UCV>4.6 V vs. Li/Li + . The costs of these battery packs are lowest at UCV = 4.7 V (vs. Li/Li + ); estimated at 135–145 and 210–220 $·kWh –1 for BEV and PHEV packs, respectively.

25 ENERGY STORAGE↗

A low-cost sulfate-based all iron redox flow battery

Redox flow batteries (RFBs) are promising choices for stationary electric energy storage. Nevertheless, commercialization is impeded by high-cost electrolyte and membrane materials. Here, we report a low-cost all-iron RFB that features inexpensive FeSO 4 electrolytes, microporous membrane along with a glass fiber separator. The addition of 0.1 м 1-ethyl-3-methylimidazolium chloride (EMIC) overcomes the low solubility of FeSO 4 in water which is raised to 2.2 м. DFT calculations demonstrate that EMI + can strengthen the interaction between sulfate anions and water molecules. This electrolyte composition also allows both anode and cathode reactions to operate without actively maintaining a pH gradient between them, thus eliminating the need for expensive ion exchange membranes. The all-iron RFB demonstrates stable operation at a current density of 20 mA cm –2 for more than 800 cycles via a simple, periodic regeneration process. Furthermore, the system cost of FeSO 4 /EMIC RFBs is projected to be $ 50 per kWh due to its low-cost active materials and the inexpensive microporous membrane. Finally, this low-cost, high-concentration all-iron RFB is a promising stationary energy–storage system for storing renewable energy.

25 ENERGY STORAGE↗

Bipolar plate flow channel designs for vanadium redox flow battery: a review

Vanadium redox flow battery is one of the preferred systems for grid scale energy storage due to long service life (>20000 cycles), higher efficiency (>85 %), deep discharge capability (>95 % DoD), and inherent scalability and safety. Among system components, flow field is most critical as it governs electrolyte distribution, mass transport and hydraulic performance. Here, this review examines emerging flow channel geometries, highlighting the impact of channel width (0.66 to 1.5 mm), depth (1 to 1.5 mm) and land width (0.5 to 1.5 mm) can reduce pressure drop to <10 kPa while enabling power densities above 600 mW.cm -2 . A key finding is that low channel width to depth ratio (<1) enhances voltage and energy efficiencies by improving under rib convection. The review also provides an overview of progress and perspective in bipolar plate materials, manufacturability, and shunt current mitigation strategies for stack scaling up. Cost analysis emphasizes the influence of flow field designs on the levelized cost of storage and pathways towards the US DOE's $\$$0.05 per kWh energy generation cost target. In addition, opportunities for AI/ML/DT tools assisted design and data driven optimization strategies are also outlined to accelerate next generation flow field development.

Efficiency optimization↗

Molten Lithium-Brass/Zinc Chloride System as High-Performance and Low-Cost Battery

Batteries with high safety, low cost, and reasonable energy density are essential for grid-scale energy storage and still remain elusive. In this paper, we report a solid electrolyte-based liquid lithium-brass/zinc chloride (SELL-brass/ZnCl 2 ) battery using garnet-type lithium-ion solid electrolyte, lithium anode, and brass/ZnCl 2 cathode. The chemistry of the cell reaction and the ability of being assembled in discharged state ensures a high safety. The use of low-cost ZnCl 2 cathode can realize a low cell material cost of $16 kWh –1 . The adoption of lithium anode guarantees a high theoretical energy density of 750 Wh kg –1 and 2,250 Wh L –1 . Moreover, by using brass powder as a Zn source in the cathode, the Zn particle growth issue is successfully solved, and a good cycling stability of the battery can be obtained. As full cell performance and scalability are also verified, our SELL-brass/ZnCl 2 battery shows a high potential for practical use in grid energy storage.

25 ENERGY STORAGE↗

Energy storage based on SrCO 3 and Sorbents—A probabilistic analysis towards realizing solar thermochemical power plants

As greenhouse gases threaten our environment, it has become increasingly necessary to replace consumption of fossil fuels with renewable energy. Without energy storage, solar cannot provide power at night during times of peak demand, resulting in a gap between supply capabilities and demand. Solar thermochemical energy storage (TCES) has potential to resolve this critical temporal issue. An 800MWh th TCES subsystem has been designed to cost-effectively convert solar energy to electricity. An evaluation of each required component is provided, including the reactor chemistry. Strontium carbonate decomposition is used to densely store high temperature thermal energy via chemical reaction, while two different CO 2 storage methods are considered. To determine the practical feasibility of these schemes, a probabilistic analysis has been performed to explore exergy and energy efficiency, and cost. It has been found that a scheme storing CO 2 via sorbents is capable of ~71% energy and ~87% exergy efficiency, and an installed cost of ~48 USD kWh th -1 .

25 ENERGY STORAGE↗

Environmental and economic optima of solar home systems design: A combined LCA and LCC approach

Here, we compare the economic and environmental optimal design of Solar Home Systems (SHSs) and explore the role of economic incentives (such as tariffs and technology costs) in approximating the two optima. To achieve that, we present a methodology for the environmental and economic evaluation of grid-connected SHSs: user-scale electric systems involving a photovoltaic (PV) power system and a battery energy storage system. The proposed methodology is based on a mixed integer linear programming (MILP) optimization, life cycle assessment and life cycle costing. This methodological framework is applied to a case study involving a typical SHS installation in Italy. The results of the environmental optimal design brought to the evaluation of a 3.25 kW PV assisted by 8.66 kWh of nickel cobalt manganese batteries, whereas the costs of the SHS are minimized by a small PV system (less than 1 kW). Results underline that the environmental optimal configurations rely on battery technologies, which entails a significant cost compared to the grid connection. In contrast, the economic optimal design solutions is less impactful than the grid mix both from an environmental and economic points of view. Thanks to a reduction of batteries and PV costs, the environmental impact of the economic optimal design is expected to decrease in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy and cost analysis of a solar-hydrogen combined heat and power system for remote power supply using a computer simulation

A simulation program, based on Visual Pascal, for sizing and techno-economic analysis of the performance of solar-hydrogen combined heat and power systems for remote applications is described. The accuracy of the submodels is checked by comparing the real performances of the system's components obtained from experimental measurements with model outputs. The use of the heat generated by the PEM fuel cell, and any unused excess hydrogen, is investigated for hot water production or space heating while the solar-hydrogen system is supplying electricity. A 5 kWh daily demand profile and the solar radiation profile of Melbourne have been used in a case study to investigate the typical techno-economic characteristics of the system to supply a remote household. The simulation shows that by harnessing both thermal load and excess hydrogen it is possible to increase the average yearly energy efficiency of the fuel cell in the solar-hydrogen system from just below 40% up to about 80% in both heat and power generation (based on the high heating value of hydrogen). The fuel cell in the system is conventionally sized to meet the peak of the demand profile. However, an economic optimisation analysis illustrates that installing a larger fuel cell could lead to up to a 15% reduction in the unit cost of the electricity to an average of just below 90 c/kWh over the assessment period of 30 years. Further, for an economically optimal size of the fuel cell, nearly a half the yearly energy demand for hot water of the remote household could be supplied by heat recovery from the fuel cell and utilising unused hydrogen in the exit stream. Such a system could then complement a conventional solar water heating system by providing the boosting energy (usually in the order of 40% of the total) normally obtained from gas or electricity. (author)

14 SOLAR ENERGY↗

Modeling, design and thermal performance of a BIPV/T system thermally coupled with a ventilated concrete slab in a low energy solar house: Part 2, ventilated concrete slab

This paper is the second of two papers that describe the modeling and design of a building-integrated photovoltaic-thermal (BIPV/T) system thermally coupled with a ventilated concrete slab (VCS) adopted in a prefabricated, two-storey detached, low energy solar house and their performance assessment based on monitored data. The VCS concept is based on an integrated thermal-structural design with active storage of solar thermal energy while serving as a structural component - the basement floor slab ({proportional_to}33 m{sup 2}). This paper describes the numerical modeling, design, and thermal performance assessment of the VCS. The thermal performance of the VCS during the commissioning of the unoccupied house is presented. Analysis of the monitored data shows that the VCS can store 9-12 kWh of heat from the total thermal energy collected by the BIPV/T system, on a typical clear sunny day with an outdoor temperature of about 0 C. It can also accumulate thermal energy during a series of clear sunny days without overheating the slab surface or the living space. This research shows that coupling the VCS with the BIPV/T system is a viable method to enhance the utilization of collected solar thermal energy. A method is presented for creating a simplified three-dimensional, control volume finite difference, explicit thermal model of the VCS. The model is created and validated using monitored data. The modeling method is suitable for detailed parametric study of the thermal behavior of the VCS without excessive computational effort. (author)

14 SOLAR ENERGY↗

Energy and economic performance analysis of an open cycle solar desiccant dehumidification air-conditioning system for application in Hong Kong

In this article, a transient simulation model and the EnergyPlus were used to study the energy performance and economical feasibility for integrating a solar liquid desiccant dehumidification system with a conventional vapor compression air-conditioning system for the weather condition of Hong Kong. The vapor compression system capacity in the solar assisted air-conditioning system can be reduced to 19 kW from original 28 kW of a conventional air-conditioning system as a case study due to the solar desiccant cooling. The economical performance of the solar desiccant dehumidification system is compared with that of the conventional air-conditioning system. The results show that the energy saving potentials due to incorporation of the solar desiccant dehumidification system in a traditional air-conditioning system is significant for the hot wet weather in Hong Kong due to higher COP resulted from higher supply chilled water temperature from chiller plants. The annual operation energy savings for the hybrid system is 6760 kWh and the payback period of the hybrid system is around 7 years. The study shows that the solar assisted air-conditioning is a viable technology for utilizations in subtropical areas. (author)

14 SOLAR ENERGY↗