Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “isotope separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Chemical separation of 146 Sm for half-life determination

Here, although methods for the chemical separation of samarium from a rock matrix are well established, chemical separation of samarium from non-natural isotopic impurities for the purpose of 146 Sm half-life measurement requires modifications to these procedures, as well as additional checks for effective separation. This work describes the chemical purification procedures associated with the 146 Sm source and the results from gamma spectroscopy. The purification procedure allowed for the quantitative determination of the number of 146Sm atoms using a modified isotope dilution technique. Alpha-decay counting of the sample will be applied in the future to determine the half-life of 146 Sm.

146Sm↗

Mass measurements of neutron-rich nuclei near $N = 70$

The astrophysical origin for the chemical elements between the first and second r-process peaks is a matter of intense debate, with a number of nucleosynthesis processes at explosive stellar environments possibly contributing to their production. Reliable data on the trends of neutron separation energies of neutron-rich isotopes are required to model neutron-capture processes that would produce these elements. Masses of 104 Y, 106 Zr, 112 Mo, and 115 Tc have been measured with the time-of-flight-magnetic-rigidity (ToF–Bρ) technique at the National Superconducting Cyclotron Laboratory at Michigan State University. The experiment is the first application of the ToF–Bρ technique at the S800 spectrograph that reached the mass region relevant to heavy-element nucleosynthesis. Finally, the two-neutron separation energy deduced from the measured masses exhibits a smooth trend consistent with the theoretical predictions within the range of experimental uncertainty, indicating that there is no sudden shape transition in these isotopes as hinted at by previous data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Separation of radium and actinium using zirconia

Herein, zirconia was investigated as a radiation-resistant support for radium and actinium aqueous ion separations. Acetate and total metal ion concentrations were experimentally evaluated as factors that could affect retention using La and Ba surrogates. Pseudo-second order rate constants were derived and the uptake of La was determined to be endothermic. Elution profiles containing Ba, La, 228 Ra, 228 Ac, and 212 Pb are presented and discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Harvesting 88 Zr from heavy-ion beam irradiated tungsten at the National Superconducting Cyclotron Laboratory

Tungsten is a commonly used material at many heavy-ion beam facilities, and it often becomes activated due to interactions with a beam. Many of the activation products are useful in basic and applied sciences if they can be recovered efficiently. In order to develop the radiochemistry for harvesting group (IV) elements from irradiated tungsten, a heavy-ion beam containing 88 Zr was embedded into a stack of tungsten foils at the National Superconducting Cyclotron Laboratory and a separation methodology was devised to recover the 88 Zr. The foils were dissolved in 30% hydrogen peroxide, and the 88 Zr was chemically purified from the tungsten matrix and from other co-implanted radionuclides (such as 85 Sr and 88 Y) using strong cation-exchange (AG MP-50) chromatographic resin in sulfuric acid media. The procedure provided 88 Zr in approximately 60 mL 0.5 M sulfuric acid with no detectable radio-impurities. The overall recovery yield for 88 Zr was (92.3 ± 1.2)%. In conclusion, this proof-of-concept experiment has facilitated the development of methodologies to harvest from tungsten and tungsten-alloy parts that are regularly irradiated at heavy-ion beam facilities.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement and Theory of Gas-Phase Ion Mobility Shifts Resulting from Isotopomer Mass Distribution Changes

The unanticipated discovery of recent ultra-high-resolution ion mobility spectrometry (IMS) measurements revealing that isotopomers-compounds that differ only in the isotopic substitution sites-can be separated has raised questions as to the physical basis for their separation. A study comparing IMS separations for two isotopomer sets in conjunction with theory and simulations accounting for ion rotational effects provides the first-ever prediction of rotation-mediated shifts. The simulations produce observable mobility shifts due to differences in gas–ion collision frequency and translational-to-rotational energy transfer. These differences can be attributed to distinct changes in the moment of inertia and center of mass between isotopomers. The simulations are in broad agreement with the observed experiments and consistent with relative mobility differences between isotopomers. These results provide a basis for refining IMS theory and a new foundation to obtain additional structural insights through IMS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The new Device for Indirect Capture Experiments on Radionuclides at LANSCE: Efforts on measuring the resonance(s) responsible for the extremely large 88 Zr (n,γ) cross section

The thermal neutron capture cross section of 88 Zr was recently reported to be the second largest in nature with the largest resonance integral measured. Presumably, these very large values are caused by a resonance or resonances very near thermal energy. Determining their energies and widths, and hence the shape of the cross section away from thermal energies,is useful for applications. The short half-life (83.4 days) and associated large background, renders direct measurements of the neutron capture cross section impossible using current techniques. However, it is possible to measure the total neutron cross section, and hence the resonance properties, using the newly commissioned Device for Indirect Capture Experiments on Radionuclides (DICER) at the Los Alamos Neutron Science Center (LANSCE). Transmission measurements are utilized as a surrogate method to perform capture measurements. The 88 Zr needed for a DICER measurement was produced at the Isotope Production Facility (IPF) and cleanly separated from the production target material. A description of the new instrument, efforts and preliminary results on 88 Zr will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Decay of a microsecond seniority 3 isomeric state in Hf 155

Excited states in the neutron-deficient nuclide Hf 155 have been investigated in experiments performed at the Accelerator Laboratory of the University of Jyväskylä. The Hf 155 nuclei were produced in fusion-evaporation reactions induced by beams of 295 and 315 MeV Ni 58 ions bombarding an isotopically enriched Pd 102 target and separated using the recoil mass separator MARA. An isomeric state having a half-life of 510(30) ns was discovered and is interpreted as a seniority υ = 3 , ( π h 11 / 2 2 ⊗ ν f 7 / 2 ) 27 / 2 − configuration. The γ -ray transitions emitted in the deexcitation of the isomeric state to the ground state were identified and a level scheme was constructed, from which the excitation energy of the isomer was determined to be 2581.5(10) keV. A B ( E 2 ) value of 0.45(3) W.u. was deduced for the 105.4 keV transition depopulating the isomeric state. The deduced level scheme and B ( E 2 ) value are compared with systematics and shell-model calculations. Published by the American Physical Society 2024

Physics↗

Proof-of-concept studies of novel protocols for producing highly pure 48 V from a 48 Cr/ 48 V generator

Here, the quest to improve the quality of nuclear data, such as half-lives, transition yields, and reaction cross-sections, is a shared endeavor among various areas of nuclear science. 48 V is a vanadium isotope for which experimental data on neutron reaction cross-sections is needed. However, traditional isotope production techniques cannot produce 48 V with high enough isotopic purity for some of these measurements. “Isotope harvesting” at the Facility for Rare Isotope Beams (FRIB) is a new isotope production technique that could potentially yield 48 V with the necessary purity for such studies. In this case, 48Cr would be collected and allowed to generate 48 V that can be separated from undecayed 48 Cr to yield highly pure 48 V. Thus, any protocol for producing pure 48 V via isotope harvesting would involve utilizing a separation technique that can effectively separate 48 Cr and 48 V. In this study, the radiotracers 51 Cr and 48 V were used to develop possible radiochemical separation methodologies, which can be translated to obtain high purity 48 V via this novel isotope production method. The developed protocols utilize either ion exchange or extraction chromatographic resins. Separations of 51 Cr and 48 V with AG 1-X8 anion exchange resin respectively resulted in recoveries of 95.6(26)% and 96.2(12)% with radionuclidic purities of 92(2)% and 99(1)%. An even more effective Cr and V separation was obtained with an extraction chromatographic resin (TRU resin) and 10 M HNO 3 loading solution. Here, 51 Cr and 48 V respectively had recoveries of 94.1(28)% and 96.2(13)% with high radionuclidic purities (100(2)% and 100(1)%) in small volumes (8.81(8) mL and 5.39(16) mL). This study suggests that, to maximize the yield and isotopic purity of 48 V, the best production protocol would involve utilizing two separations with TRU resin and 10 M HNO 3 to isolate 48 Cr and purify the generated 48 V.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

An Evaluation of Actinide Reactivity with CO 2 , O 2 , and O 2 /He Gases using Inductively Coupled Plasma Tandem Mass Spectrometry: Application to Simultaneous Measurement of 241 Am/ 241 Pu Ratios in Unseparated Complex Matrices

Accurate actinide measurements are critical within the field of nuclear science. Traditional methods for actinide quantification require time-consuming sample processing prior to analysis. There is a need for rapid analytical techniques that still maintain a high degree of accuracy. In this work, actinide reactivity was assessed for multiple oxygen-containing reaction gases using quadrupole inductively coupled plasma tandem mass spectrometry (Q-ICP-MS/MS) to evaluate actinide analysis in complex sample matrices without analyte-matrix separation. A novel method was developed to measure 241 Am/ 241 Pu in complex sample matrices using O 2 /He reaction gas with no matrix removal or analyte pre-concentration. This inline method reduces matrix-derived polyatomic interferences that complicate traditional ICP-MS analyses by mass-shifting to 241 Am 16 O + and 241 Pu 16 O 2 + , allowing Am and Pu to be mass separated for simultaneous analysis. While mass shifting is efficient, a small portion of Am + (<1.3%) and Pu + (<1.4%) react to from AmO 2 + and PuO + , respectively. Therefore, a mass balance approach was used, in combination with reactivity determined from 242 Pu and 243 Am standard solutions, to correct for residual 241 PuO + and 241 AmO 2 + . The method was validated by measuring 241 Am/ 241 Pu in Pu isotope standards CRM-136 and CRM-137 (separated in March/April 1970 and February 2022, respectively) in both neat solutions and complex matrices containing diluted soil (NIST SRM 2711a, >1000 µg·g -1 ). Method detection limits of 15.9 and 9.6 fg·g -1 were determined for 241 Am and 241 Pu, respectively, and 241 Am/ 241 Pu ratios were measured with accuracies within <3.5%. In conclusion, this work presents the first direct analysis of 241 Am/ 241 Pu in unseparated complex matrices, advancing capabilities for rapid actinide measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New isotope 286 Mc produced in the 243 Am + 48 Ca reaction

In this paper, we present results of the second experiment on the synthesis of Mc isotopes in the 243 Am + 48 Ca reaction performed at the gas-filled separator DGFRS-2 of the SHE Factory at JINR. Here, the new isotope 286 Mc was synthesized, and its half-life of $20^{+98}_{–9}$ ms and α-particle energy of 10.71 ± 0.02 MeV were determined. A 286 Mc α–decay chain was recorded down to the spontaneous fission of 266 Db. The spontaneous fission of 279 Rg was observed for the first time in one of four new decay chains of 287 Mc. The excitation function of the reaction was measured at three 48 Ca energies of 242, 250, and 259 MeV; the latter resulted in the first observation of the 5$\textit{n}$–evaporation channel with a cross section of $0.5^{+1.3}_{–0.4}$ pb. The decay properties of 21 previously known odd–$\textit{Z}$ isotopes were improved. The potential for an electron-capture decay mode is discussed for 288 Mc and 284 Nh isotopes. The half-lives of spontaneously fissioning nuclei produced in the 48 Ca–induced reactions with actinide targets are compared with several theoretical predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electrophoretic device and method to separate and detect analyte ions

This invention is directed to an inexpensive, miniaturized, portable, low-power device and method for electrophoretic separation and electrochemical detection of an analyte, including different isotopes of the same element. The invention replaces a conventional or microfabricated capillary electrophoresis tube with a microchip comprising an array of parallel electrophoretic separation nanotubes or aligned hollow channels fabricated in a porous substrate.

Klavetter, Kyle C.↗

Metal Organic Frameworks for Noble Gas Isotope Harvesting at FRIB (Final Technical Report)

This project was a collaborative effort between Lawrence Livermore National Laboratory (LLNL) and Michigan State University (MSU) to investigate the use of promising metal organic frameworks (MOFs) for radioactive noble gas capture, with a focus on harvesting exotic radiokryptons from FRIB. After screening several candidate materials, two MOFs were selected for testing: SIFSIX-3Cu and SBMOF-1. Further evaluation showed that although SIFSIX-3Cu has a high selectivity for Kr, SBMOF-1 is less sensitive to the humidity that is present in the FRIB harvesting system and is more readily integrated into the harvesting infrastructure. SBMOF-1 was then evaluated for temperature-dependent Kr and Xe uptake in order to determine the sorption enthalpy. The SBMOF-1 data led to the design of a noble gas capture system that will be fabricated and put into service for isotope harvesting at FRIB as part of a separate project.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RF deflecting cavity for fast radioactive ion beams

Abstract The Facility for Rare Isotope Beams (FRIB) will be a new scientific user facility that produces rare-isotope beams for experiments from the fragmentation of heavy ions at energies of 100–200 MeV/u. During the projectile fragmentation, the rare isotope of interest is produced along with many contaminants that need to be removed before the beam reaches detectors. At FRIB, this is accomplished with a magnetic projectile fragment separator. However, to achieve higher beam purity, in particular for proton-rich rare isotopes, additional purification is necessary. RadiaBeam in collaboration with Michigan State University (MSU) has designed a 20.125 MHz radiofrequency (RF) fragment separator capable of producing a 4 MV kick with 18 cm aperture in order to remove contaminant isotopes based on their time of flight. In this paper, we will discuss the RF and engineering design considerations of this separator cavity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Innovative high-temperature ammonium bifluoride fusion and rapid analysis of elements with nuclear forensic value

High-temperature ammonium bifluoride (ABF) fusions were evaluated for potential use in rapid dissolution of post-detonation nuclear debris. The ABF fusion was carried out in a Pt crucible which allowed evaluation of higher fusion and evaporation temperatures. The high-temperature ABF fusion dissolution method was evaluated using geological reference materials: USGS QLO-1a Quartz Latite, USGS SDC-1 Mica Schist, and NIST 278 Obsidian Rock. The optimized dissolution method involved a 10 min fusion at 540 °C, a 5 min reflux in 8 M HNO 3 , an evaporation at 300 °C and final dilution into 45 mL of 2% (v/v) HNO3. The final solution was filtered after heating at 105 °C using a hotblock. This dissolution method was simple, requiring only a hotplate or hotblock, filtered samples were available for ICP-MS analysis or radiochemical separation within 150 min, and was found to have high (>90%) recovery for many isotopes of interest in nuclear forensics applications. U and Pu in the dissolved material was separated using TEVA and UTEVA extraction chromatography columns, a process which resulted in >90% recovery. An irradiated U tracer was spiked into the material prior to dissolution and analyzed for recovery of major fission products and 239Np. The monitored radionuclides had recoveries of greater than 90%, except for the volatile radioiodine isotopes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New approach to precisely measure γ-ray intensities for long-lived fission products, with results for the decay of 95 Zr

For many fission products, the rays emitted following decay provide an easily-detectable signature that can be used to identify their quantities and distributions in a sample. As a result, γ-ray spectroscopy is often exploited to study fission-product yields, provided sufficiently accurate information on the γ-ray intensity is available. However, in many cases, the uncertainties in the existing nuclear data are large enough that they compromise the precision achievable for modern experiments and applications. To address this need, we have developed a new experimental method that is well suited to precisely measure absolute γ-ray intensities in the β decay of long-lived fission products. The approach involves the production of a radiopure sample by implantation of a mass-separated ion beam from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) facility on a thin carbon foil. The emitted β-decay radiation is detected with a 4π gas proportional counter and a meticulously efficiency-calibrated high-purity germanium (HPGe) detector. As a first measurement to demonstrate the approach, we studied the absolute γ-ray intensities of the strongest transitions following the β decay of 95 Zr and its decay-daughter 95 Nb, and determined them to fractional precisions of better than 1–2%. In addition, with a larger sample of activity produced through neutron irradiation of an isotopically-enriched Zr foil, we performed a high-precision measurement of the relative γ-ray intensities following the decay of 95 Zr with just the HPGe detector. Here, the sample-production method at CARIBU and the coincidence detection approach demonstrated here can be applied to study fission products with half-lives longer than a day, which includes isotopes important not only for nuclear-energy and national-security applications, but also for medical-isotope research and environmental monitoring.

4π↗

Progress towards the FRIB-EDM 3 -Frontend: A tool to provide radioactive molecules from isotope harvesting for fundamental symmetry studies

The under-construction FRIB-EDM 3 -instrument was designed to study polar radioactive molecules (such as RaF) in transparent cryogenic solids by laser spectroscopy. The instrument is divided into a frontend- and a backend section. The frontend accepts an aqueous sample from isotope harvesting and provides a mass-separated molecular ion beam in an ultra-high vacuum environment. In the backend, the ions are guided into alkali-metal vapor and the resulting neutrals are co-deposited in a solid argon matrix to perform laser spectroscopy. Here, this work addresses the frontend of the instrument. The efficient ionization of harvested radioisotopes from aqueous samples is achieved with a spray-ionization method. Subsequently, the molecular ion beam is analyzed by mass-to-charge ratio by a quadrupole mass filter. To verify the feasibility of the approach, numerical simulations with the COMSOL and SIMION packages have been conducted. While the former was applied to study transport in ion funnels, the latter was used to investigate ion beam transmission through the lower pressure sections. Following promising simulation results, a first experimental setup is under construction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Actinide in Air (Rn-Progeny Rejected) Alpha Spectroscopy With Tensioned Metastable Fluid Detectors

Here, this article discusses outcome of research for deriving a methodology and apparatus for ascertaining for the presence of ultratrace-level actinides in air from their alpha emission signatures, while remaining blind to the relatively large (1000× higher activity) alpha emissions from Rn-progeny. Apparatus and techniques were developed to collect and characterize alpha-emitting nuclides of Rn-progeny and actinides in air on a polycarbonate 3 μm pore size continuous air monitor (CAM) filter. A wet-chemistry approach was developed and validated for successfully separating the Rn-progeny alpha emitting isotopes of Po-214 and Po-218, while extracting the actinides (U, Pu, Am) in a fluid mixture that is suitable for conduct of alpha spectroscopy with a centrifugally tensioned metastable fluid detector (CTMFD). The resulting α-TMFD technology was compared against the state-of-art “Alpha-Sentry™” Continuous Air Monitor (CAM) system commonly utilized world-wide. Results indicate that the α-TMFD technology can potentially offer complementary and superior performance in multiple performance categories, and ∼18× improvement in the time to detect (e.g., at 0.02 derived air concentration (DAC) within ∼3 h, versus ∼70 h for Alpha-Sentry) for actinides of interest while also remaining ∼100% blind to ∼10 3 × higher Rn-progeny background—with the added potential for offering few keV scale energy resolution without resorting to peak shape fitting, versus ∼300–400 keV for existing CAM systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗