Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Gas Pressure Gauge Based on Alpha-Particle Induced Ion Currents

The use of ionization currents for measuring pressure was first demonstrated in the late 1940's. The early gauges operated at high voltages and used rather large ion sources. The ionization gauge is actually a densitometer that is sensitive to the temperature and pressure of the gas in the chamber. This report describes the use of low voltages and small ion sources in the development of a prototype.

transducers gas pressure gauge alpha particles ion↗

The Origin of the Near-Earth Plasma Population During a Substorm on November 24, 1996

We investigate the origins and the transport of ions observed in the near-Earth plasma sheet during the growth and expansion phases of a magnetospheric substorm that occurred on November 24, 1996. Ions observed at Geotail were traced backward in time in time-dependent magnetic and electric fields to determine their origins and the acceleration mechanisms responsible for their energization. Results from this investigation indicate that, during the growth phase of the substorm, most of the ions reaching Geotail had origins in the low latitude boundary layer (LLBL) and had already entered the magnetosphere when the growth phase began. Late in the growth phase and in the expansion phase a higher proportion of the ions reaching Geotail had their origin in the plasma mantle. Indeed, during the expansion phase more than 90% of the ions seen by Geotail were from the mantle. The ions were accelerated enroute to the spacecraft; however, most of the ions' energy gain was achieved by non-adiabatic acceleration while crossing the equatorial current sheet just prior to their detection by Geotail. In general, the plasma mantle from both southern and northern hemispheres supplied non-adiabatic ions to Geotail, whereas the LLBL supplied mostly adiabatic ions to the distributions measured by the spacecraft. Distribution functions computed at the ion sources indicate that ionospheric ions reaching Geotail during the expansion phase were significantly heated. Plasma mantle source distributions indicated the presence of a high-latitude reconnection region that allowed ion entry into the magnetosphere when the IMF was northward. These ions reached Geotail during the expansion phase. Ions from the traditional plasma mantle had access to the spacecraft throughout the substorm.

Ashour-Abdalla, M.↗

Mass spectrometric determination of the composition of the Venus clouds

The design of a mass spectrometer, based on the results of the Venera and Mariner probes, with sensitivity high enough to detect the HCl in the Venus atmosphere is discussed. One way to analyze the clouds is by the introduction of the atmosphere with cloud particles through a molecular leak into the mass spectrometer. The analysis can be performed in regular Nier-type ion sources with the electrodes of materials which are completely free of Cl and F. The problem of preventing the blockage of the capillaries to the Nier type ion source is also considered.

Source record↗

A new mass spectrometer system for investigating laser-induced vaporization phenomena

A laser has been combined with a mass spectrometer in a new configuration developed for studies of high-temperature materials. A vacuum-lock, solid-sample inlet is mounted at one end of a cylindrical, high-vacuum chamber one meter in length with a nude ion-source, time-of-flight mass spectrometer at the opposite end. The samples are positioned along the axis of the chamber at distances up to one meter from the ion source, and their surfaces are vaporized by a pulsed laser beam entering via windows on one side of the chamber. The instrumentation along with its capabilities is described, and results from laser-induced vaporization of several graphites are presented.

Lincoln, K. A.↗

Operating Characteristics of a 15-cm dia. Ion Engine for Small Planetary Spacecraft

A 15-cm diameter, scaled-down version of the NASA light-weight 30-cm ion engine has been developed for potential application to very small planetary spacecraft. Integration of the 15-cm ion source into 4x15-cm segmented engine configuration results in a 30-cm equivalent engine which can be throttled over a 7-to-1 input power variation with a constant beam current in each of the four segments. Throttling the segmented engine by turning off individual segments can result in a significant decrease in the required service life (and qualification requirements) of the ion source components.

grids segmented ion engine↗

Atomic and molecular oxygen densities in the lower thermosphere

The Atmospheric Explorer-C satellite used a neutral mass spectrometer containing a quasi-open ion source operating either in normal mode or in one that utilizes the satellite velocity to distinguish between incoming ambient particles and ambient particles which have struck instrument surfaces and become accommodated. An analysis was made of data from the mass spectrometer for those orbits when the open ion source operated either partially or entirely in the fly-through mode. A comparison of N2 density, total O density and O2/N2 density values at 200 km was made. The average N2 and O2 density values agree well with previous rocket soundings and other studies. It is believed that the individual absolute number densities obtained in the normal mode of operation are accurate to within 20% while those deduced from fly-through data may be accurate to only 30%.

Nier, A. O.↗

MAVEN Observation of an Obliquely Propagating Low-Frequency Wave Upstream of Mars

We report Mars Atmosphere and Volatile EvolutioN (MAVEN) mission observations of a large amplitude low-frequency plasma wave that propagated oblique to the ambient magnetic field upstream of Mars along with a non-solar-wind plasma component that had a flow velocity perpendicular to the magnetic field. We consider nine possibilities for this wave that include various combinations of its propagation direction, polarization in the solar wind frame, and ion source responsible for its generation. Using the observed wave parameters and the measured plasma parameters as constraints, we uniquely identify the wave by systematically discarding these possibilities. We determine that the wave is a right-hand polarized wave that propagated upstream in the solar wind frame. We find two possibilities for the ion source that can be responsible for this wave generation. They are either newly born pickup protons or reflected solar wind protons from the bow shock.We determine that the observed non-solar-wind component is not responsible for the wave generation, and it is likely that the non-solar-wind component was merely perturbed by the passage of the wave.

low frequency wave↗

Isotope-ratio-monitoring gas chromatography-mass spectrometry: methods for isotopic calibration

In trial analyses of a series of n-alkanes, precise determinations of 13C contents were based on isotopic standards introduced by five different techniques and results were compared. Specifically, organic-compound standards were coinjected with the analytes and carried through chromatography and combustion with them; or CO2 was supplied from a conventional inlet and mixed with the analyte in the ion source, or CO2 was supplied from an auxiliary mixing volume and transmitted to the source without interruption of the analyte stream. Additionally, two techniques were investigated in which the analyte stream was diverted and CO2 standards were placed on a near-zero background. All methods provided accurate results. Where applicable, methods not involving interruption of the analyte stream provided the highest performance (sigma = 0.00006 at.% 13C or 0.06% for 250 pmol C as CO2 reaching the ion source), but great care was required. Techniques involving diversion of the analyte stream were immune to interference from coeluting sample components and still provided high precision (0.0001 < or = sigma < or = 0.0002 at.% or 0.1 < or = sigma < or = 0.2%).

NASA Discipline Exobiology↗

Data acquisition techniques for exploiting the uniqueness of the time-of-flight mass spectrometer: Application to sampling pulsed gas systems

Mass spectra are produced in most mass spectrometers by sweeping some parameter within the instrument as the sampled gases flow into the ion source. It is evident that any fluctuation in the gas during the sweep (mass scan) of the instrument causes the output spectrum to be skewed in its mass peak intensities. The time of flight mass spectrometer (TOFMS) with its fast, repetitive mode of operation produces spectra without skewing or varying instrument parameters and because all ion species are ejected from the ion source simultaneously, the spectra are inherently not skewed despite rapidly changing gas pressure or composition in the source. Methods of exploiting this feature by utilizing fast digital data acquisition systems, such as transient recorders and signal averagers which are commercially available are described. Applications of this technique are presented including TOFMS sampling of vapors produced by both pulsed and continuous laser heating of materials.

Lincoln, K. A.↗

Mass spectrometer beam system for applications in the stratosphere

A special gas inlet system is required for reduction of high ambient pressures to ion source operating pressures for mass spectrometer investigations in the stratosphere for the determination of the abundance of minor constituents. A system has been designed which combines a mass spectrometer and a gas inlet system reducing pressure by differential pumping using high-speed liquid helium pumps and small orifices. The gas particles are formed into a neutral beam with a flag mechanism proceeding into the mass spectrometer ion source where they are ionized for subsequent mass separation. A laboratory model has been tested under conditions simulating stratospheric pressures. It was shown that the process is able to identify gases with abundances below 10 to the -8th. Some of the problems associated with gas analysis of trace constituents have been alleviated, and other applications of the system have been identified, such as pollution control and medicine.

Mauersberger, K.↗

Silicon Emitter Needle and Array Design for Indium Electrospray Arrays for Spacecraft Propulsion

A design for silicon microfabricated emitter arrays was developed for electrospray thrusters for indium propellant in compact architectures with scalable thrust, low mass and volume, high specific impulse and high efficiency operation. The design elements include tip height, height uniformity across the array, tip radii, axial groove depth, tip angle, emitter shank sidewall angle and number of emitters. They were derived from commercial liquid metal ion source designs and modeling, fabrication and test results. The most critical results of the emitter array design analysis suggest that microfabricated silicon emitter array emitters should have a height greater than 280 microns with a height uniformity of +/-10 microns, a tip half angle of 49° for uniform turn-on voltages and current across the array, low beam divergence and high mass utilization efficiency. Elements of the design were fabricated and demonstrated in single emitter and in 400 element emitter arrays to validate the design, fabrication and performance capability. The design height and uniformity of arrays was demonstrated for 85% of the emitters in a prototype array. Required tip and sidewall angles and groove depths have been microfabricated. Single microfabricated silicon emitters demonstrated better performance in current and voltage characteristics than commercially available liquid metal ion sources. Microfabricated emitters and arrays demonstrated the required current and stability performance to enable the MEP thruster development for indium propellant.

Marrese-Reading, Colleen M.↗

Determination of ammonia in ethylene using ion mobility spectrometry

A simple procedure to analyze ammonia in ethylene by ion mobility spectrometry is described. The spectrometer is operated with a silane polymer membrane., 63Ni ion source, H+ (H2O)n reactant ion, and nitrogen drift and source gas. Ethylene containing parts per billion (ppb) (v/v) concentrations of ammonia is pulled across the membrane and diffuses into the spectrometer. Preconcentration or preseparation is unnecessary, because the ethylene in the spectrometer has no noticeable effect on the analytical results. Ethylene does not polymerize in the radioactive source. Ethylene's flammability is negated by the nitrogen inside the spectrometer. Response to ammonia concentrations between 200 ppb and 1.5 ppm is near linear, and a detection limit of 25 ppb is calculated.

NASA Discipline Environmental Health↗

New apparatus increases ion beam power density

To increase ion engine or rocket power, an ion source and emitter, an ion beam focusing electrode, and an ion accelerator are incorporated into the system. In operation the space charge surrounding the ion emitter decreases, the ion beam density accelerates, and engine power increases.

Baldwin, L. V.↗

Electrostatic, short-wavelength, turbulence as the source of ion heating in the solar wind

A mechanism is proposed for the nonthermal ion heating observed in the solar wind at 1 A.U. based on an electrostatic, short wavelength, instability between the ions in the observed colliding plasma streams. The modes lying on a plane perpendicular to the magnetic field thermalize most of the differential energy. The model suggests local electrostatic turbulence, that alpha-particles are heated more than protons, a maximum proton temperature T sub P 1 million k, and for the bulk speed U possibly a sq root of T sub P = aU + b relationship. These predictions are consistent with observations.

Papadoupoulis, K.↗

Optical and electrical properties of ion beam textured Kapton and Teflon

An electron bombardment argon ion source was used to ion etch polyimide (Kapton) and fluorinated ethylene, FEP (Teflon). Samples of polyimide and FEP were exposed to (0.5-1.0) keV Ar ions at ion current densities of (1.0-1/8) mA/sq cm for various exposure times. Changes in the optical and electrical properties of the samples were used to characterize the exposure. Spectral reflectance and transmittance measurements were made between 0.33 and 2.16 micron m using an integrating sphere after each exposure. From these measurements, values of solar absorptance were obtained. Total emittance measurements were also recorded for some samples. Surface resistivity was used to determine changes in the electrical conductivity of the etched samples. A scanning electron microscope recorded surface structure after exposure. Spectral optical data, resistivity measurements, calculated absorptance and emittance measurements are presented along with photomicrographs of the surface structure for the various exposures to Ar ions.

Mirtich, M. J.↗

Adhesive bonding of ion beam textured metals and fluoropolymers

An electron bombardment argon ion source was used to ion etch various metals and fluoropolymers. The metal and fluoropolymers were exposed to (0.5 to 1.0) keV Ar ions at ion current densities of (0.2 to 1.5) mA/sq cm for various exposure times. The resulting surface texture is in the form of needles or spires whose vertical dimensions may range from tenths to hundreds of micrometers, depending on the selection of beam energy, ion current density, and etch time. The bonding of textured surfaces is accomplished by ion beam texturing mating pieces of either metals or fluoropolymers and applying a bonding agent which wets in and around the microscopic cone-like structures. After bonding, both tensile and shear strength measurements were made on the samples. Also tested, for comparison's sake, were untextured and chemically etched fluoropolymers. The results of these measurements are presented.

Mirtich, M. J.↗