Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “integer optimal control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

168 records · Page 10

Stochastic scheduling of generating units with weekly energy storage: A hybrid decomposition approach

We propose a solution method for the large-scale stochastic unit commitment (SUC) problem with weekly-dispatched energy storage and significant weather-dependent stochastic generating capacity. Weekly storage facilities that mostly charge during weekends and discharge during weekdays require a weekly scheduling of generating units, which result in a large-scale optimization problem. This SUC problem is formulated as a two-stage stochastic model and we use the conditional value-at-risk as a risk measure. Using a Benders framework, the proposed solution method decomposes the problem into a mixed-integer linear master problem and linear and continuous subproblems. The master problem corresponds to the first-stage decisions throughout the week and includes all the commitment (binary) variables and their corresponding constraints. The subproblems correspond to the actual dispatch of the generating units on a weekly basis. Based on the success of column-and-constraint generation algorithms to solve robust optimization problems, we improve the low communication between the master problem and the subproblems in the standard Benders decomposition by adding primal variables and constraints from the subproblems to the master problem, which provides a better approximation of the recourse function. Furthermore, our computational experiments demonstrate the effectiveness of the proposed decomposition method using an instance of the South Carolina synthetic system with 90 generating units under 40 scenarios.

25 ENERGY STORAGE↗

Analysis and prediction of reaction kinetics using the degree of rate control

“Degree of rate control” (DRC) analysis provides a quantitative approach for analysing the kinetics of multi-step reaction mechanisms that has been widely applied to both heterogeneous and homogeneous catalysis research, as well as electrocatalysis. The DRC of any given transition state or intermediate is defined as a partial derivative such that it approximately equals the fractional increase in net rate to the product of interest per differential decrease in its standard-state free energy for that species (÷RT), holding constant the standard-state free energies of all other transition states and intermediates. Even very complex mechanisms usually have only a few species with non-zero DRCs and are thus the species whose interactions with the catalyst most strongly affect the net rate. These key DRC values thus offer a simple and intuitive route to optimize catalyst materials, especially with the assistance of computational methods like density functional theory (DFT). These high-DRC species are also the species whose energetics must be most accurately measured or calculated to achieve an accurate kinetic model for any reaction mechanism. In simple cases with a single “rate-determining step”, the DRC for its transition state (TS) is + 1. Catalyst-bound intermediates, on the other hand, often have negative DRCs equal to a small integer times their fractional occupancy of catalyst sites. The apparent activation energy equals a weighted average of the standard-state enthalpies (relative to reactants) of all the species (intermediates, transition states and products) in the reaction mechanism, each weighted by its DRC (+RT). It has been shown that the apparent transfer coefficient in electrocatalysis, an inverted form of the Tafel slope, is a weighted average of the number of electrons transferred to generate each intermediate or product species in the mechanism, weighted again by the DRC. Quantitative analysis of kinetic isotope effects (KIEs, or the ratio of net rates for different reactant isotopes) in complex mechanisms has shown that the logarithm of the KIE equals the weighted average over all species in the mechanism of the difference between the two isotopes in their standard-state free energies (÷RT), again weighted by the DRC. The reaction orders with respect to fluid-phase concentrations of reactants, products and intermediates have also been proven to be directly related to DRCs. Thus, there are numerous experimental observables which equate to short linear combinations of DRCs, so that combinations of experimental measurements might provide access to DRC values. Since its invention for transition states in 1994 and its generalization to include intermediates in 2009, the DRC has thus far mainly been calculated for microkinetic models based either entirely on DFT or on DFT with the key energies (i.e., those for high-DRC species) being fine-tuned to match experiments. The relationships summarized in this work provide new opportunities for using experiments earlier in the development and optimization of microkinetic models that require input from computational catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Control-Oriented Modeling of Lithium-Ion Batteries

Battery management systems (BMSs), which monitor and optimize performance while ensuring safety, require control-oriented models, i.e., models tailored to the design and implementation of estimation and control algorithms. Physics-based electrochemical models describe detailed battery phenomena, but are too computationally intensive for use in estimation and control applications. Single particle models (SPMs), which retain some of the physics of electrochemical models, are often used for control-oriented battery modeling since they are computationally efficient; however, they are only valid over very low frequency ranges and C-rates. Empirical equivalent circuit models (ECMs) are also used for control-oriented battery modeling since they are computationally efficient and can describe battery behavior over wide frequency ranges; however, they provide no physical understanding of the battery and, therefore, have limited applicability. Further, fractional order terms (e.g., Warburg impedances) are often employed, making the models unwieldy for use in the time domain. This work provides a control-oriented battery model that combines the benefits of SPM and ECM models, while overcoming their limitations. The proposed model incorporates some of the battery physics found in electrochemical models, can easily be used in both the time and frequency domains, and describes battery behavior over its entire frequency range. A linearized single particle model, which incorporates key electrochemical parameters, is used for modeling battery physics at very low frequencies. For low frequencies, integer-order linear systems are used to approximate diffusion physics described by Warburg impedances, and high frequency behavior is modeled by the double layer capacitance effect. The proposed battery model is more computationally efficient than full electrochemical models since it does not require the solution of PDEs, is accurate for a wider frequency range than the SPM considered in this paper, and does not suffer from the unwieldiness and limited applicability of empirical ECMs. Finally, the model is validated in the time and frequency domains via a comparison to pseudo-two-dimensional (P2D) model simulations and experimental data.

25 ENERGY STORAGE↗

An MILP-Based Distributed Energy Management for Coordination of Networked Microgrids

An MILP-based distributed energy management for the coordination of networked microgrids is proposed in this paper. Multiple microgrids and the utility grid are coordinated through iteratively adjusted price signals. Based on the price signals received, the microgrid controllers (MCs) and distribution management system (DMS) update their schedules separately. Then, the price signals are updated according to the generation–load mismatch and distributed to MCs and DMS for the next iteration. The iteration continues until the generation–load mismatch is small enough, i.e., the generation and load are balanced under agreed price signals. Through the proposed distributed energy management, various microgrids and the utility grid with different economic, resilient, emission and socio-economic objectives are coordinated with generation–load balance guaranteed and the microgrid customers’ privacy preserved. In particular, a piecewise linearization technique is employed to approximate the augmented Lagrange term in the alternating direction method of multipliers (ADMM) algorithm. Thus, the subproblems are transformed into mixed integer linear programming (MILP) problems and efficiently solved by open-source MILP solvers, which would accelerate the adoption and deployment of microgrids and promote clean energy. The proposed MILP-based distributed energy management is demonstrated through various case studies on a networked microgrids test system with three microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rapid Crossing of a Resonance During Tune Modulation by Synchrotron Oscillations

It had become a standard practice to constrain the particle’s tune footprint while designing the ring lattice so that the particle tunes fit between harmful resonances that limit ring dynamic aperture (DA). This approach, known as “tune confinement”, puts tight limits on the magnitude of the tune shifts with amplitude and with momentum. The latter requires labor-intensive optimization of the off-energy dynamic aperture and control over the corresponding tune footprint for the large energy deviations and is a prerequisite to achieving reasonable lifetime if it is dominated by the Touschek scattering. As nonlinearities of the modern ring lattices are much enhanced as compared with the previous generation of synchrotron light sources, it is becoming more and more difficult to keep the off-momentum tune footprint confined. While one could reach reasonable on-energy DA suitable for injection into the machine, the off-energy DA optimization is much more complex and needs to satisfy more constraints so to reach large energy acceptance and secure decent lifetime at the high ring current. In certain cases when the lattice solution with the confined off-energy tune footprint cannot be found, one may ask whether crossing of a resonance stopband from off-momentum particle will lead to loss of this particle. Intuitively, if the particle crosses the stopband quickly, one may expect that the betatron oscillation amplitude will not increase substantially thereby keeping the particle within the machine acceptance. At the same time the tight tolerances of the modern lattice elements as designed and produced afford much narrower resonance stopbands being compared with the machines built decades ago. Under these circumstances the question above may be asked as what are the conditions for operating a ring with a large chromatic tune footprint, which crosses resonances, while not observing particle losses. In this paper we try to answer the questions above by studying the model of a particle with large initial momentum deviation (as, for example, driven by the Touschek scattering event), which crosses stopband of a half-integer resonance while executing synchrotron oscillations in the highly chromatic ring lattice.

36 MATERIALS SCIENCE↗

Building Load Control Using Distributionally Robust Chance-Constrained Programs with Right-Hand Side Uncertainty and the Risk-Adjustable Variants

Aggregation of heating, ventilation, and air conditioning (HVAC) loads can provide reserves to absorb volatile renewable energy, especially solar photo-voltaic (PV) generation. In this paper, we decide HVAC control schedules under uncertain PV generation, using a distributionally robust chance-constrained (DRCC) building load control model under two typical ambiguity sets: the moment-based and Wasserstein ambiguity sets. We derive mixed integer linear programming (MILP) reformulations for DRCC problems under both sets. Especially, for the Wasserstein ambiguity set, we use the right-hand side (RHS) uncertainty to derive a more compact MILP reformulation than the commonly known MILP reformulations with big-M constants. All the results also apply to general individual chance constraints with RHS uncertainty. Furthermore, we propose an adjustable chance-constrained variant to achieve tradeoff between the operational risk and costs. We derive MILP reformulations under the Wasserstein ambiguity set and second-order conic programming (SOCP) reformulations under the moment-based set. Using real-world data, we conduct computational studies to demonstrate the efficiency of the solution approaches and the effectiveness of the solutions. Summary of Contribution: The problem studied in this paper is motivated by a building load control problem that uses the aggregation of heating, ventilation, and air conditioning (HVAC) loads as flexible reserves to absorb uncertain solar photovoltaic (PV) generation. The problem is formulated as distributionally robust chance-constrained (DRCC) programs with right-hand side (RHS) uncertainty. In addition, we propose a risk-adjustable variant of the DRCC programs, where the risk level, instead of being predetermined, is treated as a decision variable. The paper aims to provide tractable reformulations and solution algorithms for both the (general) DRCC and the (general) adjustable DRCC models with RHS uncertainty.

97 MATHEMATICS AND COMPUTING↗