Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installed capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Compensation for Long-Duration Energy Storage

Rapidly changing power system conditions, driven by decarbonization goals, are leading to significant growth in renewable energy sources, which can be both variable and uncertain. This has been accompanied with increased reliance on and rapid growth in deployment of energy storage technologies. Currently, approximately 90% of installed, utility-scale energy storage capacity in the United States comes from pumped storage hydropower (PSH). However, development of new PSH has been limited and all recent growth in energy storage has come from batteries, , especially as technology costs have decreased over the years. Most of the current deployment still remains in the form of short-duration (<6 hours) energy storage technologies; the average duration of new storage was 3.7 hours for projects deployed in the first half of 2021 (Wood Mackenzie and Energy Storage Association 2021).

25 ENERGY STORAGE↗

Enabling Floating Solar Photovoltaic (FPV) Deployment: FPV Technical Potential Assessment for Southeast Asia

Southeast Asia (SE Asia) is a region with growing energy demand and increasing development of floating solar photovoltaic (FPV) systems, which can help meet countries' renewable energy and energy security goals. This study uses a high-level geospatial assessment methodology to estimate the technical potential for monofacial and bifacial FPV on reservoirs and natural waterbodies in the ten countries within the Association of Southeast Asian Nations (ASEAN). Technical potential consists of the suitable waterbody area for FPV development (km 2 ), the capacity of FPV that could be installed on this suitable area (MW), and the annual energy that could be generated from these installations (GWh/year). This first-of-its-kind FPV technical potential assessment for SE Asia can help policymakers and planners better understand the role that FPV could play in meeting regional energy demand and can ultimately guide investment decisions. Although this work focuses on SE Asia, the methodology may also be applicable for countries in other regions, with adaptations.

14 SOLAR ENERGY↗

Description of data base management systems activities

One of the major responsibilities of the JPL Computing and Information Services Office is to develop and maintain a JPL plan for providing computing services to the JPL management and administrative community that will lead to improved productivity. The CISO plan to accomplish this objective has been titled 'Management and Administrative Support Systems' (MASS). The MASS plan is based on the continued use of JPL's IBM 3032 Computer system for administrative computing and for the MASS functions. The current candidate administrative Data Base Management Systems required to support the MASS include ADABASE, Cullinane IDMS and TOTAL. Previous uses of administrative Data Base Systems have been applied to specific local functions rather than in a centralized manner with elements common to the many user groups. Limited capacity data base systems have been installed in microprocessor based office automation systems in a few Project and Management Offices using Ashton-Tate dBASE II. These experiences plus some other localized in house DBMS uses have provided an excellent background for developing user and system requirements for a single DBMS to support the MASS program.

Source record↗

Achieving American Leadership in the Wind Supply Chain Factsheet

Land-based and offshore wind are expected to be a cornerstone for achieving U.S. clean electricity generation objectives, including 100% clean electricity by 2035 and an 30 gigawatts (GW) of offshore wind by 2030. Meeting these goals will require significant expansion of domestic supply chains and installation of unprecedented amounts of wind capacity.

Source record↗

Enabling Floating Solar Photovoltaic (FPV) Deployment: FPV Technical Potential Assessment for Southeast Asia

Southeast Asia (SE Asia) is a region with growing energy demand and increasing development of floating solar photovoltaic (FPV) systems, which can help meet countries' renewable energy and energy security goals. This study uses a high-level geospatial assessment methodology to estimate the technical potential for monofacial and bifacial FPV on reservoirs and natural waterbodies in the ten countries within the Association of Southeast Asian Nations (ASEAN). Technical potential consists of the suitable waterbody area for FPV development (km2), the capacity of FPV that could be installed on this suitable area (MW), and the annual energy that could be generated from these installations (GWh/year). This first-of-its-kind FPV technical potential assessment for SE Asia can help policymakers and planners better understand the role that FPV could play in meeting regional energy demand and can ultimately guide investment decisions. Although this work focuses on SE Asia, the methodology may also be applicable for countries in other regions, with adaptations. The FPV technical potential results are also integrated into the Renewable Energy (RE) Data Explorer online tool (https://www.re-explorer.org/).

bifacial↗

Graph-based Simulation Framework for Power Resilience Estimation and Enhancement

The increasing frequency of extreme weather events poses significant risks to power distribution systems, leading to widespread outages and severe economic and social consequences. This paper presents a novel simulation framework for assessing and enhancing the resilience of power distribution networks under such conditions. Resilience is estimated through Monte Carlo simulations, which simulate extreme weather scenarios and evaluate the impact on infrastructure fragility. Due to the proprietary nature of power network topology, a distribution network is synthesized using publicly available data. To generate the weather scenarios, an extreme weather generation method is developed. To enhance resilience, renewable resources such as solar panels and energy storage systems (batteries in this study) are incorporated. A customized Genetic Algorithm is proposed to determine the optimal locations and capacities for solar panels and battery installations, maximizing resilience while balancing cost constraints. Experiment results demonstrate that on a large-scale synthetic distribution network with more than 300,000 nodes and 300,000 edges, the proposed framework can efficiently evaluate the resilience, and enhance the resilience through the installations of distributed energy resources (DERs), providing utilities with valuable insights for community-level power system resilience estimation and enhancement.

Wang, Xuesong [Wayne State Univ., Detroit, MI (Uni↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System (Rev.1)

The Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions LLC (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), was selected as the ion exchange media at TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, exchange kinetics of Cs onto CST is slow, resulting in low utilization of the CST Cs load capacity before unacceptable Cs breakthrough. Two process flow designs have been tested, as follows. 1. Lead-lag column processing: The lead column was removed after the lag column effluent reached the waste acceptance criteria (WAC) limit, the lag column was moved into the lead position, and a new lag column was installed. This format used ~52% Cs load capacity on the lead column. 2. Lead-lag-polish column processing: The processing was stopped when the polish column effluent reached the WAC limit. This format resulted in 81% Cs load capacity on the lead column. Testing with diluted feed from Hanford tank AP-105 (AP-105DF) incorporated a nuanced change to the lead-lag-polish column system where the polish column was inserted when the lag column effluent reached WAC limit. A 10.9-L volume of AP-105DF (diluted to 5.6 M Na) was processed through the Direct Feed Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 10-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.83 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The <30-mesh CST sieve cut was expected to provide appropriate performance scaling to a full-height column. The installation of the polish column later in processing (after processing 523 BVs) did not appear to fundamentally change the utilization of the lead column for Cs exchange nor did it extend the total feed processing volume when compared to the previous test with AP-107 feed. Table ES.1 and Figure ES.1 summarize the measured AP-105DF Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lunar power system summary of studies for the lunar enterprise task force NASA-office of exploration

The capacity of global power systems must be increased by a factor of ten to provide the predicted power needs of electric power by the year 2050. The Lunar Power System (LPS) would collect solar energy at power bases located on opposing limbs of the moon as seen from Earth. LPS can provide dependable, economic, renewable, and environmentally benign solar energy to Earth. A preliminary engineering and cash flow model of the LPS was developed. Results are shown for a system scaled to a peak capacity of 355 GWe on Earth and to provide 13,600 GWe-Yrs of energy over a 70 year life cycle of construction and full operation. The growth in capacity of the reference system from start of installation on the moon in 2005 to completion of its nominal life cycle in the year 2070 is shown. World needs for power could be accommodated by expansion in capacity of the reference LPS beyond 344 GWe. This would be done by steadily incorporating newer technology during full operation and by establishing additional bases. The results presented encourage consideration of a faster paced program than is assumed herein.

Criswell, David R.↗

The Need for Vendor Source Code at NAS

The Numerical Aerodynamic Simulation (NAS) Facility has a long standing practice of maintaining buildable source code for installed hardware. There are two reasons for this: NAS's designated pathfinding role, and the need to maintain a smoothly running operational capacity given the widely diversified nature of the vendor installations. NAS has a need to maintain support capabilities when vendors are not able; diagnose and remedy hardware or software problems where applicable; and to support ongoing system software development activities whether or not the relevant vendors feel support is justified. This note provides an informal history of these activities at NAS, and brings together the general principles that drive the requirement that systems integrated into the NAS environment run binaries built from source code, onsite.

Carter, Russell↗

The geographies, typologies, and trends of community-based organizations for solar energy in the United States

Community-based organizations (CBOs)1 play an important role in developing solar energy in low- and moderate-income (LMI) communities. This article shares the perspectives of CBO leaders in LMI communities, identifies and addresses solar information gaps, and provides recommendations State Energy Agencies and other government leaders can use to better involve CBOs in solar program initiatives. Using semi-structured interviews and focus groups with CBOs from across the United States (US) we develop typologies of CBO structure and function, and determine the primary motivations, challenges, opportunities, and communication barriers CBOs face. We explore the correlation between key typologies such as tenure, staff capacity, population served, organizational structure, and region with the organizational activities performed by solar-related CBOs. CBOs operate in disparate regional political and economic ecologies. Our findings suggest strategies for states to support their engagement in solar-related endeavors, particularly with respect to the dissemination of the Bipartisan Infrastructure Law, Inflation Reduction Act, and the EPA Greenhouse Gas Reduction Fund: Solar for All. Developing policies that encourage CBOs to enter the solar training and installation domains, alongside targeted grants and capacity-building initiatives can help maximize community benefits. Furthermore, states can additionally contribute to the positive trajectory and collaboration between state agencies and CBOs in advancing solar energy adoption by fostering a supportive environment.

14 SOLAR ENERGY↗

Impact of installation faults in air conditioners and heat pumps in single-family homes on U.S. energy usage

To ensure that new residential air conditioners and heat pumps operate optimally, care must be taken during the initial system design and installation to avoid missteps that immediately degrade a system’s performance. Laboratory and simulation studies have quantified the impact that faults can have on capacity and efficiency. Field studies have demonstrated that installation-related faults are commonplace. However, the national impact of installation-related faults cannot be accurately estimated by only simulating a limited number of homes at several fault levels because of the variety of home characteristics and climates involved. In our analysis, we use an improved residential building stock simulation tool to predict the annual energy increase and additional utility costs resulting from two common installation faults: indoor airflow rate and refrigerant charge level. Our method considers the wide range of building characteristics and climate zones of the U.S. housing stock. We use existing field data to develop fault intensity probability distributions to inform our analysis. The study shows that these two faults result in approximately 20.7 TWh/y of additional energy use for central air conditioners and air-source heat pumps in U.S. single-family detached homes, which is a 9% increase over baseline (no-fault) usage, costing homeowners approximately $2.5 billion annually on utility bills. Air-source heat pumps are responsible for a disproportionate fraction of this energy use increase because of the larger number of operating hours compared to central air conditioners and the sensitivity of heating mode performance to the faults analyzed compared to cooling mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatially-Explicit Prediction of Capacity Density Advances Geographic Characterization of Wind Power Technical Potential

Mounting interest in ambitious clean energy goals is exposing critical gaps in our understanding of onshore wind power potential. Conventional approaches to evaluating wind power technical potential at the national scale rely on coarse geographic representations of land area requirements for wind power. These methods overlook sizable spatial variation in real-world capacity densities (i.e., nameplate power capacity per unit area) and assume that potential installation densities are uniform across space. Here, we propose a data-driven approach to overcome persistent challenges in characterizing localized deployment potentials over broad extents. We use machine learning to develop predictive relationships between observed capacity densities and geospatial variables. The model is validated against a comprehensive data set of United States (U.S.) wind facilities and subjected to interrogation techniques to reveal that key explanatory features behind geographic variation of capacity density are related to wind resource as well as urban accessibility and forest cover. We demonstrate application of the model by producing a high-resolution (2 km × 2 km) national map of capacity density for use in technical potential assessments for the United States. Our findings illustrate that this methodology offers meaningful improvements in the characterization of spatial aspects of technical potential, which are increasingly critical to draw reliable and actionable planning and research insights from renewable energy scenarios.

17 WIND ENERGY↗

Least-cost targets and avoided fossil fuel capacity in India’s pursuit of renewable energy

India has set aggressive targets to install more than 400 GW of wind and solar electricity generation by 2030, with more than two-thirds of that capacity coming from solar. This paper examines the electricity and carbon mitigation costs to reliably operate India’s grid in 2030 for a variety of wind and solar targets (200 GW to 600 GW) and the most promising options for reducing these costs. We find that systems where solar photovoltaic comprises only 25 to 50% of the total renewable target have the lowest carbon mitigation costs in most scenarios. This result invites a reexamination of India’s proposed solar-majority targets. We also find that, compared to other regions and contrary to prevailing assumptions, meeting high renewable targets will avoid building very few new fossil fuel (coal and natural gas) power plants because of India’s specific weather patterns and need to meet peak electricity demand. However, building 600 GW of renewable capacity, with the majority being wind plants, reduces how often fossil fuel power plants run, and this amount of capacity can hold India’s 2030 emissions below 2018 levels for less than the social cost of carbon. With likely wind and solar cost declines and increases in coal energy costs, balanced or wind-majority high renewable energy systems (600 GW or ≈ 45% share by energy) could result in electricity costs similar to a fossil fuel-dominated system. As an alternative strategy for meeting peak electricity demand, battery storage can avert the need for new fossil fuel capacity but is cost effective only at low capital costs (≈ USD 150 per kWh).

14 SOLAR ENERGY↗

Exploring the Impact of Near-Term Innovations on the Technical Potential of Land-Based Wind Energy

Land based wind may play a critical role in reaching emissions reductions goals and high renewable contribution scenarios with capacity expansion modeling results estimating over 1 terawatt of land-based wind by 2035 to reach 100% clean electricity. Deployment of land-based wind at this magnitude may require significant investments in transmission infrastructure and will require significant land area for new wind and transmission. Cost reductions via technological advancements in wind turbine design, construction, and maintenance will have a major role in enabling the scale of deployment required. Since 1998, the levelized cost of wind energy has fallen by over 60% due to improvements in capacity factors, advancements in turbine controls, and cost reductions in installation, operation, and maintenance. These cost reduction pathways, generally referred to as wind technology "innovations", have enabled significant increases in the capacity and electric generation share of wind power in the United States. Nevertheless, achievements of past wind innovations have not led to widespread wind deployment outside of high wind speed geographies. This study evaluates the potential of near-term innovations to expand the geographic range of economically viable land-based wind power production in the United States. Many challenges to future deployment of wind power can be associated with increasing concentration in high-wind areas. As more wind power is deployed in these same areas, it is likely that residential and regulatory resistance to further deployment will increase, access to transmission will diminish, and options for distant companies and governments with renewable energy goals will remain limited. Therefore, this analysis aims to emphasize the potential for innovations to enable land-based wind in regions with limited wind deployment and with lower wind resource and better access to transmission.

17 WIND ENERGY↗

Insights from FEED studies for retrofitting existing fossil power plants with carbon capture technology

Recent United States Department of Energy (DOE) sponsored front-end engineering design (FEED) studies for retrofitting existing fossil-fueled power plants with state-of-the-art carbon capture technology contain previously overlooked real-world design considerations for near-term deployment of carbon capture. Insights from examining seven recently published FEED study reports are summarized in this paper. This includes a discussion of the design, performance, and cost implications associated with (1) location-specific considerations such as water availability, land availability, and accessibility; (2) host-plant-specific factors such as flue gas specifications, allowable degree of integration between the capture system and host plant, and operational mode; and (3) miscellaneous factors such as market conditions, permitting requirements, and business case incentives. In conclusion, this manuscript highlights (1) water availability as a key design and cost driver, with host plant steam extraction increasing capture system cooling water availability, (2) modularization and constructability impacts on the number of capture trains, (3) the impacts of host plant operational mode and capacity factor on the business case for installing capture, and (4) the merit of continued research, development, and demonstration efforts addressing steam extraction, host plant tie-in at the stack, solvent reclamation and air emissions control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cesium Removal Performance Comparisons of Crystalline Silicotitanate Media Batches with Savannah River Site Waste Simulant

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with Crystalline Silicotitanate (CST) media to process radioactive waste solutions for the removal of Cs137. TCCR currently focuses on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium salt cake solids) within the tank followed by at-tank ion exchange column treatment. Plans are underway to prepare and install a second TCCR unit at SRS. Capacity and particle size differences exist between archived (IE-911) and more recently-prepared CST media batches (9120- B and 9140-B). Side-by-side comparison testing was performed to evaluate the cesium removal performance of each batch to aid in selecting the preferred CST batch and media characteristics to load into the second TCCR unit. Batch contact equilibrium and flow-through column tests have been conducted with three CST batches using an SRS Average Simulant. Simulant batch contact equilibrium cesium loading results for the three CST batches (including two lots of one batch) are provided in Table ES-1. The 35 °C data indicates that the archived IE-911 batch has a higher cesium capacity than recently-prepared CST media and that the minor TCCR CST 9120-B media lot (2099000035) has similar cesium removal performance to the major TCCR lot (2099000034). Tests conducted at 25 ºC for the archived IE-911 CST batch indicated lower cesium removal performance with this simulant batch than was observed recently with a different SRS Average Simulant batch. A dilution factor (DF) is typically utilized when modeling engineered CST media cesium loading performance to account for mass contributions from the binder material. In cases where CST performance is lower than expected, this factor includes corrections for the binder and for low performance. The ZAM (Zheng, Anthony, and Miller) Isotherm Model DF values are provided in Table ES-1 for each simulant batch contact result. DF values near 0.5 were determined for the 9120-B and 9140-B CST batch contact tests while DF values near 0.6 (20% higher) were determined for the tests with IE-911. These dilution factors are lower than recently observed with a different SRS Average Simulant batch (9140-B DF = 0.68; IE-911 DF = 1.0). Based on these results, it appears that some component in the simulant solution used for equilibrium testing may have resulted in reduced cesium loading on the CST media.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal Performance Comparisons of Crystalline Silicotitanate Media Batches with Savannah River Site Waste Simulant

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with Crystalline Silicotitanate (CST) media to process radioactive waste solutions for the removal of Cs- 137. The TCCR project is currently focused on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium salt cake solids) within the tank followed by at-tank ion exchange column treatment. Plans are underway to prepare and install a second TCCR unit at SRS. Capacity and particle size differences exist between archived (IE-911) and more recently prepared CST media batches (9120-B and 9140-B). Side-by-side comparison testing was performed to evaluate the cesium removal performance of each batch to aid in selecting the preferred CST batch and media characteristics to load into the second TCCR unit. Batch contact equilibrium and flow-through column tests have been conducted with three CST batches using an SRS Average Simulant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technology Evaluation of the Yotta SolarLEAF: A Panel-Based Thermally Managed Battery Module

In 2019, the United States installed 13.3 gigawatts of solar energy production capacity. This demand for solar will continually increase as the phasing out of fossil fuels continue. As the demand for solar energy grows, so does the demand to store this generated energy. It is projected that by 2035 the global demand for stationary energy storage will reach the terawatt scale. So, scalable solutions with suitable thermal management systems are required to meet future demand. Yotta Solar has developed an ESS system, the Yotta LEAF, that provides solar energy storage without increasing the footprint of solar arrays. This is particularly useful in applications with limited space (e.g., building roof) and where large scale batteries require strong requirements for fire suppression systems. As part of the Wells Fargo Innovation Incubator (IN2), the National Renewable Energy Laboratory (NREL) has conducted a third-party technology validation of Yotta's alpha prototype. The report includes the objectives, technology description, methodology, and results from experiments conducted at the Thermal Transfer Facility (TTF) at NREL.

14 SOLAR ENERGY↗