Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “infrastructure optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A novel large-scale EV charging scheduling algorithm considering V2G and reactive power management based on ADMM

Electric vehicle aggregators (EVAs) that utilize vehicle-to-grid (V2G) technologies can function as both controllable loads and virtual power plants, providing key energy management services to the distribution system operator (DSO). EVAs can also balance the grid’s reactive power as a virtual static VAR compensator (SVC) and provide voltage stability by utilizing advanced electric vehicle (EV) chargers that are capable of four-quadrant operations to provide reactive power management. Finally, managed charging can benefit EVAs themselves by minimizing power factor penalties in their electricity bills. In this paper, we propose a novel EV charging scheduling algorithm based on a hierarchical distributed optimization framework that minimizes peak load and provides reactive power compensation for the DSO by collaboration with EVAs that manage both the active and the reactive charging and discharging power of participating EVs. Utilizing the alternative direction method of multipliers (ADMM), the proposed distributed optimization approach scales well with increased EV charging infrastructure by balancing active and reactive power while decreasing computational burden. In our proposed hierarchical approach, each EVA schedules the active and reactive EV charging and discharging power for 1) reactive power compensation in order to minimize power factor penalty and electricity cost accrued by the EVA, 2) satisfaction of each EV’s energy demand at minimal charging cost, and 3) peak shaving and load management for the DSO. When compared with an uncoordinated charging model, the efficacy of this proposed model is successfully demonstrated through a 300% decreased peak EV load for the DSO, 28% lower electricity costs for EV users, and 98.55% smaller power factor penalty, along with 17.58% lower overall electricity costs, for EVAs. The performance of our approach is validated in a case study with 50 EVs at multiple EVAs in an IEEE 13-bus test case and compared the results with uncoordinated EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Selling Demand Response Using Options

Wholesale electricity markets in many jurisdictions use a two-settlement structure: a day-ahead market for bulk power transactions and a real-time market for fine-grain supply-demand balancing. This paper explores trading demand response assets within this two-settlement market structure. Here, we consider two approaches for trading demand response assets: (a) an intermediate spot market with contingent pricing, and (b) an over-the-counter options contract. In the first case, we characterize the competitive equilibrium of the spot market, and show that it is socially optimal. Economic orthodoxy advocates spot markets, but these require expensive infrastructure and regulatory blessing. In the second case, we characterize competitive equilibria and compare its efficiency with the idealized spot market. Options contract are private bilateral over-the-counter transactions and do not require regulatory approval. We show that the optimal social welfare is, in general, not supported. We then design optimal option prices that minimize the social welfare gap. This optimal design serves to approximate the ideal spot market for demand response using options with modest loss of efficiency. Our results are validated through numerical simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Audi e-tron Green Light Optimized Speed Advisory On-Road Data

To aid researchers in studying the capabilities and benefits of vehicle-to-infrastructure communication, Argonne National Laboratory collected a robust set of on-road driving data of the Audi Green Light Optimized Speed Advisory (GLOSA) system implemented in the e-tron battery electric vehicle. This dataset includes 33 tests, each roughly 27 miles in length and roughly 45 to 75 minutes in duration. The team selected Kane County Highway Route 34 from Main Street in Batavia, Illinois to Middlecreek Lane in St. Charles, Illinois as the route do to its high density of GLOSA-active lights and the most opportunities to observe the system per hour of test time. The data include parameters from the following sources: GLOSA system driving the dash indicators, multiple powertrain parameters including real-time battery power/energy consumption, GPS, front radar gap, and rear radar gap. ![audio-e-tron image](audi-e-tron.jpg)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantitative approaches for including equity in risk and resilience infrastructure planning analyses

Risk and resilience assessments for critical infrastructure focus on myriad objectives, from natural hazard evaluations to optimizing investments. Although research has started to characterize externalities associated with current or possible future states, incorporation of equity priorities at project inception is increasingly being recognized as critical for planning related activities. However, there is no standard methodology that guides development of equity-informed quantitative approaches for infrastructure planning activities. Here, to address this gap, we introduce a logic model that can be tailored to capture nuances about specific geographies and community priorities, effectively incorporating them into different mathematical approaches for quantitative risk assessments. Specifically, the logic model uses a graded, iterative approach to clarify specific equity objectives as well as inform the development of equations being used to support analysis. We demonstrate the utility of this framework using case studies spanning aviation fuel, produced water, and microgrid electricity infrastructures. For each case study, the use of the logic model helps clarify the ways that local priorities and infrastructure needs are used to drive the types of data and quantitative methodologies used in the respective analyses. The explicit consideration of methodological limitations (e.g., data mismatches) and stakeholder engagements serves to increase the transparency of the associated findings as well as effectively integrate community nuances (e.g., ownership of assets) into infrastructure assessments. Such integration will become increasingly important to ensure that planning activities (which occur throughout the lifecycle of the infrastructure projects) lead to long-lasting solutions to meet both energy and sustainable development goals for communities.

community-based↗

Optimal Siting of EV Fleet Charging Station Considering EV Mobility and Microgrid Formation for Enhanced Grid Resilience

Coordinating infrastructure planning for transportation and the power grid is essential for enhanced reliability and resilience during operation and disaster management. This paper presents a two-stage stochastic model to optimize the location of electric vehicle fleet charging stations (FEVCSs) to enhance the resilience of a distribution network. The first stage of this model deals with the decision to place an FEVCS at the most favorable and optimized location, whereas the second stage aims to minimize the weighted sum of the value of lost load in multiple potential scenarios with different faults. Indeed, the second stage is a joint grid restoration scheme with network reconfiguration and microgrid formation using available distributed generators and fleet electric vehicles. The proposed model is tested on a modified IEEE-33 node distribution network and a four-node transportation network. Case studies demonstrate the effectiveness of the proposed model.

25 ENERGY STORAGE↗

Energy Optimization of Light and Heavy-Duty Vehicle Cohorts of Mixed Connectivity, Automation and Propulsion System Capabilities via Meshed V2V-V2I and Expanded Data Sharing (Final Scientific and Technical Report)

Vehicle connectivity and automated driving technologies individually have the potential to decrease energy consumption and/or increase safety on light, medium or heavy duty vehicles to varying degrees depending on the traffic infrastructure and specific driving scenarios. Due to advances in sensing, perception and computing power, research and development emphasis in the mobility sector has shifted away from connectivity. Prior research has shown that driving automation with the absence of connectivity can in certain circumstances increase energy consumption. The effectiveness of synergizing connectivity and driving automation technologies is the focus of this work, specifically applied to vehicle cohorts of mixed composition, light and heavy duty, and powertrains ranging from all electric to conventional internal combustion engine. The project team is led by Michigan Technological University (MTU) and partnered with AVL Mobility Technologies Inc. (AVL), Borg Warner (BW), Traffic Technology Services (TTS), American Center for Mobility (ACM) and Navistar (NAV). The main thrusts for the team are to develop a micro-traffic simulation environment with specific VD&PT system attributes and CAV capabilities, 2) field a vehicle test fleet of mixed classification, propulsion and CAV capacity, 3) develop artificial intelligence (AI) and machine learning (ML) based multi-agent optimization methods for various traffic infrastructures, 4) integrate the virtual environment and the optimization methods then deploy the system as a CAV hardware in the loop (HiL) for the vehicle test fleet and 5) conduct closed track and public road testing to validate simulation and demonstrated energy and mobility improvements at multiple scales. For a cohort of mixed vehicles, the team will demonstrate a reduction of energy consumption of 10-50% at intersection, arterial roadway and limited access highway scenarios through connectivity and automation in simulation and at a closed test track. The energy reduction objectives of the project are summarized in Table 1, indicating the infrastructure and over what distances are relevant considered. Single scenario energy reductions are not relevant and thus, the research team took the approach to vary parameters associated with the infrastructure, vehicle cohort composition and dynamic behavior to generate energy consumption distributions for both unconnected and connected scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

To Derive or Not to Derive: I/O Libraries Take Charge of Derived Quantities Computation

The ever-increasing volume of data produced by HPC simulations necessitates scalable methods for data exploration and knowledge extraction. Scientific data analysis often involves complex queries across distributed datasets, requiring manipulation of multiple primary variables and generating derived data that needs to be handled efficiently, creating challenges for applications that need to parse many large datasets. Relying on individual applications to handle all intermediate data generally leads to redundant computations across studies and unnecessary data transfers. In this paper, we investigate the performance of different approaches where applications define derived variables as quantities of interest (QoIs) and offload the computation and transfer of these QoIs to the I/O library. This significantly reduces redundancy and optimizes data movement across the distributed storage and processing infrastructure by allowing control over when and where derived variables are computed. We present a detailed analysis of the performance-storage trade-offs associated with different solutions and showcase results for our study on two large-scale datasets created from climate and combustion simulations.

Gainaru, Ana↗

Joint Planning of Electricity Transmission and Hydrogen Transportation Networks

The abundance and uneven distribution of renewable energy might cause congestion and curtailment in electric power systems. Transmission expansions can potentially alleviate transmission congestion and reduce renewable energy curtailment. On the other hand, with the substantial cost reduction of electrolyzer technology and the continuing rise of hydrogen demand, converting surplus renewable energy to hydrogen provides synergistic benefits to power and hydrogen systems, but consequently requires joint planning of the two systems. To this end, we propose a joint planning approach for power transmission and hydrogen transportation networks to coordinately optimize the investment and operation of power and hydrogen infrastructure. In our proposed model, detailed truck routing, pipeline, and hydrogen storage are formulated to quantify the flexibility of hydrogen transportation system. A robust joint planning approach is also proposed to address various uncertainties from renewable energy, electric load, and hydrogen demand. Furthermore, our numerical simulations show that the proposed joint planning model can save the total system cost, reduce renewable energy curtailment, and increase the utilization level of transmission lines.

08 HYDROGEN↗

Mastering HPC Runtime Prediction: From Observing Patterns to a Methodological Approach

The continual expansion of high-performance computing (HPC) brings with it an increasing need for efficiency. Heavy investment in energy, hardware, and software infrastructure to support peta- and exascale computing requires the optimization of existing systems and, wherever possible, the discernment and adoption of best-practices towards these goals. Such is the case for runtime prediction. When a job is submitted to an HPC system, an estimate of its runtime is provided by the user in the form of "requested wallclock". Error in this user-provided estimate can lead to jobs being prematurely killed by the scheduler, increased wait time on the queue, and decreased system utilization. More than fifteen years of research has been directed at mitigating these effects by using data-driven runtime predictions. Codified here is a set of commonalities and insights emerging from this body of work, which we present as recommendations and best practices. These practices are combined into a methodological approach described and evaluated on an 11-million-job dataset from the National Renewable Energy Laboratory's petascale HPC system, Eagle. This dataset and the accompanying codebase have been released to the public domain for the benefit of the wider HPC research community.

high performance computing↗

Experimental Study of TCP Throughput Profiles and Dynamics Over Dedicated Connections

A throughput profile expressed as a function of the round-trip times of a data transport infrastructure is a critical indicator of its level of optimization, particularly, over dedicated connections. We study the throughput profiles of eleven TCP versions using measurements collected over dedicated hardware-emulated connections with distances spanning round the earth. Among them, BBR has overall higher temporal variations and lower throughput profiles compared to five loss-based TCP versions, and the comparison with other TCP versions is mixed. Using the Poincare map regions of throughput time traces, we show that the richer dynamics of BBR are correlated with its lower throughput profiles. We present basic analytical results that indicate that higher temporal variations of TCP methods lead to lower throughput profiles, thereby establishing the underlying causality. Under external losses, BBR achieves sustained high throughput compared to others as the loss rate is increased. Overall, our results provide insights into the relationship between time dynamics and throughput profiles of TCP versions, in particular, show that limited time traces can be indicative of global properties of throughput profiles.

Rao, Nageswara↗

Mastering HPC Runtime Prediction: From Observing Patterns to a Methodological Approach: Preprint

The continual expansion of high-performance computing (HPC) brings with it an increasing need for efficiency. Heavy investment in energy, hardware, and software infrastructure to support peta- and exascale computing requires the optimization of existing systems and, wherever possible, the discernment and adoption of best-practices towards these goals. Such is the case for runtime prediction. When a job is submitted to an HPC system, an estimate of its runtime is provided by the user in the form of "requested wallclock''. Error in this user-provided estimate can lead to jobs being prematurely killed by the scheduler, increased wait time on the queue, and decreased system utilization. More than fifteen years of research has been directed at mitigating these effects by using data-driven runtime predictions. Codified here is a set of commonalities and insights emerging from this body of work, which we present as recommendations and best practices. These practices are combined into a methodological approach described and evaluated on an 11-million-job dataset from the National Renewable Energy Laboratory's petascale HPC system, Eagle. This dataset and the accompanying codebase have been released to the public domain for the benefit of the wider HPC research community.

high performance computing↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on Banshee Distribution Network

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on the Banshee Distribution Network: Preprint

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Minimum GHG emissions and energy consumption of U.S. PET and polyolefin packaging supply chains in a circular economy

There is a wide agreement on the urgency of transforming linear management of plastics towards a circular economy model. However, no clear pathways exist as to required recycling technologies involved and system-wide environmental impacts. This study explores such pathways in the U.S. for the most commonly used packaging plastics through a combination of mechanical and emerging advanced recycling technologies. A system optimization model aimed at minimizing environmental impacts was developed to determine optimal end-of-life (EOL) management and locations of existing and emerging U.S. recycling infrastructures. Our study includes material flows from virgin resin production through semi-manufacturing processes to existing EOL disposal and recycling processes. An optimized circular plastics packaging system achieved greenhouse gas (GHG) emission savings of up to 28% and cumulative energy demand (CED) savings of up to 46%, compared to the linear economy. Moreover, these savings of GHG emissions and CED impacts represent a reduction of 0.16% and 0.49% compared to annual U.S. GHG emissions and energy consumption in 2022, respectively. The optimal recycling rates and systems-level circularity ranged from 78–99% and 57–75%, respectively. Increased energy savings led to increased GHG emissions showing a potential trade-off between GHG emissions and energy. Analysis of 40 scenarios showed the importance of material collection distances, blend limit of mechanically recycled resins, process yields, and mandated recycling rates for achieving a sustainable circular economy of plastics.

09 - BIOMASS FUELS↗

Analytical Modeling of Planetary Excavation for in Situ Resource Utilization

The space-faring capabilities of humans are dependent on the ability to interact with plan-etary surfaces safely and efficiently and utilize local re-sources. Since planetary regolith will be the primary feedstock for in situ resource utilization (ISRU) and infrastructure development activities [1,2], the site-specific geomechanical properties must be understood to optimize excavation operations [3]. Excavating planetary regolith is challenging due to its unique geomechanical properties, 1/6th G reduced gravity extreme conditions, and limited energy resources. Therefore, it is critical to develop technologies that reduce excavation force requirements and minimize tool path inefficiencies to save time and energy during planetary re-source acquisition and infrastructure development [3]. There have been several experimental investigations of methods to optimize planetary excavations [4,5], but none developed predictive capabilities. This abstract presents a simple analytical method that will be used to model laboratory and mission excavation data. Future work will build on the simple analytical method here to include high-fidelity numerical simulations of planetary excavation mechanics.

Regolith↗

The Value of Increased HVDC Capacity Between Eastern and Western U.S. Grids: The Interconnections Seam Study

The Interconnections Seam Study examines the potential economic value of increasing electricity transfer between the Eastern and Western Interconnections using high-voltage direct-current (HVDC) transmission and cost-optimizing both generation and transmission resources across the United States, proposing, assessing, justifying, and illustrating a major infrastructure change involving two of the worlds largest power grids. The study conducted a multi-model analysis that used co-optimized generation and transmission expansion planning and production cost modeling. Four transmission designs under eight scenarios were developed and studied to estimate costs and potential benefits. The results show benefit-to-cost ratios that reach as high as 2.5, indicating significant value to increasing the transmission capacity between the interconnections under the cases considered, realized through sharing generation resources and flexibility across regions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Gas-Electric Energy System Decarbonization Planning

As energy utilities implement climate change mitigation policies, system planners require strategies for achieving affordable emissions reductions. Coordinated planning of electric power and natural gas systems will allow synergistic investments to address cross-sector operational constraints, competing uses for net-zero emissions fuels, and shifts in energy demands across energy carriers. In this study, we develop a novel optimization program that finds the cost-minimizing mix of infrastructure expansion or reduction across gas and electric systems to satisfy sector-specific emissions constraints. Alongside energy supply resources, our framework allows for central-planning of end-use equipment stocks to allow switching between gas and electric appliances upon failure or premature replacement. The proposed model is used to simulate case study scenarios for a benchmark 24-pipe gas network coupled to a 24-node power system test network. We find that electrification of greater than 80% of core gas demands is a component of the least-cost solution for modeled energy systems. Despite this substitution, the gas system is maintained to service difficult-to-electrify customers and to deliver net-zero emissions gas to electricity generators in times of peak electricity demand. Restricting electrification of gas appliances increases reliance on power- to-gas technologies and increases annual costs by 15% in 2040. Neglecting constraints on pipeline blending of hydrogen can produce a misleading result that relies on hydrogen blend fractions of greater than 50%. In all cases, we find the average costs of delivered gas increase nearly 5-fold across the decarbonization transition, highlighting the importance of future work investigating cost-allocation strategies for ensuring an equitable energy transition.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Is a Generator the Only Solution When the Grid Fails? Optimizing Systems for Resiliency and Carbon Reduction: Preprint

Traditionally, buildings are dependent on utility infrastructure, and when a grid failure happens, end users rely on the closest source of energy storage to sustain operation until power is restored. For buildings, that typically means using an electric generator. This electric generator either uses on-site energy storage such as fossil fuels in a tank or a gas connection which is, in turn, tied to gas wells—also a form of energy storage. Generators are popular for their ease of implementation and low capital costs; however, they have limited value outside of disruptions, and they are a source of scope 1 emissions, or direct greenhouse gas emissions from sources controlled by the building owner. In contrast, some power generation and storage systems, such as photovoltaic (PV) panels and battery energy storage systems (BESS), can serve the same purpose during grid disruptions while presenting advantages outside of power failure. This paper explores methods for storing and converting energy on-site to increase building resiliency, focusing on solutions that minimize scope 1 emissions. We analyze the cost and carbon impacts of energy efficiency measures, PV arrays, and BESS, with and without generators, in a simulation test case. We find significant benefits can be achieved both during and outside of power failure events when designing systems that integrate the on-demand capability of generators, the low carbon energy supplied by PV, and the storage capabilities of BESS. Specifically, adding even minimal BESS and PV can result in downsizing the generator, increasing generator efficiency and requiring less fuel.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗