Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “impedance estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Isothermal Microcalorimetric Analysis of Li/CF x Battery Discharge

Lithium/carbon monofluoride (Li/CF x ) batteries generate substantial amounts of heat during discharge in part due to the large deviation of the loaded voltage from the measured and thermodynamically predicted open circuit voltage. Here, in this study, we further analyze this system by estimating the equilibrium voltage (V eq ) and its temperature dependence (dV eq /dT) over the entire discharge range. Based on these results, the ohmic and entropic heat contributions to the overall heat flow are calculated from experimental data. The ohmic heat flow is consistent with an electrochemical impedance spectroscopy model and electrode density measurements, indicating decreasing porosity of the electrode during discharge. Entropic heating increases during discharge as the cell reaction becomes increasingly entropically unfavorable. The total energy dissipated by the cell (electrical and thermal) remains similar over the entire discharge, evidence for a two-phase reaction with a constant, and rate-independent, ΔG rxn of about -465 kJ mol -1 . However, near the end of discharge (>90% DOD), ΔG rxn changes significantly indicating possible secondary reactions.

25 ENERGY STORAGE↗

Dielectric screening in perovskite photovoltaics

Abstract The performance of perovskite photovoltaics is fundamentally impeded by the presence of undesirable defects that contribute to non-radiative losses within the devices. Although mitigating these losses has been extensively reported by numerous passivation strategies, a detailed understanding of loss origins within the devices remains elusive. Here, we demonstrate that the defect capturing probability estimated by the capture cross-section is decreased by varying the dielectric response, producing the dielectric screening effect in the perovskite. The resulting perovskites also show reduced surface recombination and a weaker electron-phonon coupling. All of these boost the power conversion efficiency to 22.3% for an inverted perovskite photovoltaic device with a high open-circuit voltage of 1.25 V and a low voltage deficit of 0.37 V (a bandgap ~1.62 eV). Our results provide not only an in-depth understanding of the carrier capture processes in perovskites, but also a promising pathway for realizing highly efficient devices via dielectric regulation.

14 SOLAR ENERGY↗

Oxygen vacancy migration and impact on high voltage DC polarization in 0.8BaTiO 3 –0.2BiZn 0.5 Ti 0.5 O 3

Electrical polarization and defect transport are examined in 0.8BaTiO 3 –0.2BiZn 0.5 Ti 0.5 O 3 , an attractive capacitor material for high power electronics. Oxygen vacancies are suggested to be the majority charge carrier at or below 250°C with a grain conduction hopping activation energy of 0.97 eV and 0.92 eV for thermally stimulated depolarization current (TSDC) and impedance spectroscopy measurements, respectively. At higher temperature, thermally generated electronic conduction with an activation energy of 1.6 eV is dominant. Significant oxygen vacancy concentration is indicated (up to ~1%) due to cation vacancy formation (i.e., acceptor defects) from observed Bi (and likely Zn) volatility. Oxygen vacancy diffusivity is estimated to be 10 -12.8 cm 2 /s at 250°C. Low diffusivity and high activation energies are indicative of significant defect interactions. Dipolar oxygen vacancy defects are also indicated, with an activation energy of 0.59 eV from TSDC measurements. In conclusion, the large oxygen vacancy content leads to a short lifetime during high voltage (30 kV/cm), high temperature (250°C) direct current (DC) electrical measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simplified calculation of the area specific impedance for solid-state battery design

Simplified algebraic area specific impedance (ASI) correlations have been developed for solid-state composite battery electrodes made of a single ion conducting electrolyte, conductive additive, and intercalation active material. Two ASI expressions were developed, one for short times ( i.e. , pulsed power operation) and another for the pseudo steady state operation (i.e., sustained discharge for energy estimation). A full electrochemical model based on porous electrode theory was developed to examine the accuracy of the simplified ASI expressions. The simplified expressions agree favorably with full model results over a wide range of parameters (i.e. , electrode thicknesses, electrolyte conductivities, solid-state diffusion coefficients, specific surface areas, etc.) and conditions (i.e. , C-rates, states of charge, and pulse times). Under most conditions, the error between the full model and the correlations is well below 7 %. Higher errors were observed for the pseudo steady state expression at high/ low states of charge where the assumption of uniform reaction distributions loses validity. Here, the short time ASI has higher error at low states of charge due to the nonlinearity of the open circuit voltage equation, which is assumed linear in the formulation of the simplified algebraic expression.

25 ENERGY STORAGE↗

Development of modified vibration test criteria for qualifying space vehicle components

Simplified methods are described to estimate the test criteria of primary structures at component attachment points subjected to broadband random acoustic excitations. The current method utilizes a constant smeared component mass attenuation factor across the frequency range of interest. The developed method indicates that the attenuation factor is based on a frequency dependent ratio of the mechanical impedances of both the component and primary structures. The procedures used to predict the structural responses are considered as the present state-of-the-art and provide satisfactory prediction results. Example problems are used to illustrate the application procedures of the two methods and to compare the significant difference. It was found that the lower test criteria obtained by the impedance ratio method is due to the results of considering the effects of component/primary structure interaction.

Chang, K. Y.↗

Electrochemical Corrosion of SIMFUEL: Effects of dissolved H2 and noble metal particles

This report describes the results from electrochemical corrosion tests that were conducted using simulated spent fuel (SIMFUEL) materials comprised of UO2 and surrogate fission products. Two SIMFUEL compositions were tested to quantify the effect of noble metal inclusions and dissolved H2 on the UO2 dissolution rate. One material consisted of UO2 with added lanthanide oxides (UO2 N) and the other consisted of UO2 with added lanthanide oxides and noble metals (UO2-H) at concentrations to simulate high burnup fuel. The electrochemical corrosion tests on the SIMFUEL materials were conducted in aqueous electrolyte solutions (pH 10) that were either saturated with air or purged with a H2/Ar gas mixture to maintain a constant dissolved H2 concentration. The results from electrochemical corrosion tests on SIMFUEL can be applied to qualitatively understand and also quantify the separate effects of water chemistry and fuel composition on the degradation behavior of the UO2 matrix. Open circuit potential (OCP) measurements on a SIMFUEL material of known composition (i.e., known fraction of NMPs at the fuel surface) immersed in a known solution chemistry (i.e., pH, Eh, [O2], [H2]) at known temperature provide qualitative insight into the degradation behavior of the UO2 matrix. If the OCP is above the threshold potential at which the oxidative dissolution of U(IV) to U(VI) occurs, the SNF is expected to degrade by oxidative processes under the experimental conditions. The net currents that are measured during potentiostatic tests, during which the surface potential of the SIMFUEL material is fixed by a potentiostat, can be used to quantify the UO2 degradation rate and optimize the rate constant values used in the Fuel Matrix Degradation Model (FMDM) for half reactions that occur on the SNF surface. Specifically, electrochemical measurements enable the estimation of the total anodic current at ECORR–which is the surface potential at which the total anodic and total cathodic currents are equal–so that the rate constant values for key reactions can be calculated. The open circuit potential measurements, potentiostatic tests, surface property measurements (scanning electron microscopy images and electrochemical impedence spectroscopy plots), and solution elemental composition analyses are being performed to update and optimize the FMDM. A case study is presented herein to show how electrochemical corrosion test results and accompanying characterization results for the UO2 N material in air-saturated solution can be used to validate the SNF surface reaction module of the FMDM. Future electrochemical tests will be conducted to provide quantitative information on the effects of NM content (burnup), H2 concentration, water chemistry, temperature, and galvanic couples with cladding and EBS alloys on UO2 degradation that can be used to improve the accuracy and functionality of the FMDM.

Thomas, Sara↗

Electrically Small Microstrip Quarter-Wave Monopole Antennas

Microstrip-patch-style antennas that generate monopole radiation patterns similar to those of quarter-wave whip antennas can be designed to have dimensions smaller than those needed heretofore for this purpose, by taking advantage of a feed configuration different from the conventional one. The large sizes necessitated by the conventional feed configuration have, until now, made such antennas impractical for frequencies below about 800 MHz: for example, at 200 MHz, the conventional feed configuration necessitates a patch diameter of about 8 ft (.2.4 m) . too large, for example, for mounting on the roof of an automobile or on a small or medium-size aircraft. By making it possible to reduce diameters to between a tenth and a third of that necessitated by the conventional feed configuration, the modified configuration makes it possible to install such antennas in places where they could not previously be installed and thereby helps to realize the potential advantages (concealment and/or reduction of aerodynamic drag) of microstrip versus whip antennas. In both the conventional approach and the innovative approach, a microstrip-patch (or microstrip-patch-style) antenna for generating a monopole radiation pattern includes an electrically conductive patch or plate separated from an electrically conductive ground plane by a layer of electrically insulating material. In the conventional approach, the electrically insulating layer is typically a printed-circuit board about 1/16 in. (.1.6 mm) thick. Ordinarily, a coaxial cable from a transmitter, receiver, or transceiver is attached at the center on the ground-plane side, the shield of the cable being electrically connected to the ground plane. In the conventional approach, the coaxial cable is mated with a connector mounted on the ground plane. The center pin of this connector connects to the center of the coaxial cable and passes through a hole in the ground plane and a small hole in the insulating layer and then connects with the patch above one-third of the radial distance from the center. The modified feed configuration of the innovative approach is an inductive-short-circuit configuration that provides impedance matching and that has been used for many years on other antennas but not on microstrip-style monopole antennas. In this configuration, the pin is connected to both the conductive patch and the ground plane. As before, the shield of the coaxial cable is connected to the ground plane, but now the central conductor is connected to a point on the pin between the ground plane and the conductive plate (see figure). The location of the connection point on the pin is chosen so that together, the inductive short circuit and the conductive plate or patch act as components of a lumped-element resonant circuit that radiates efficiently at the resonance frequency and, at the resonance frequency, has an impedance that matches that of the coaxial cable. It should be noted that the innovative design entails two significant disadvantages. One disadvantage is that the frequency bandwidth for efficient operation is only about 1/20 to 1/15 that of a whip antenna designed for the same nominal frequency. The other disadvantage is that the estimated gain is between 3-1/2 and 4-1/2 dB below that of the whip antenna. However, if an affected radio-communication system used only a few adjacent frequency channels and the design of the components of the system other than the antenna provided adequate power or gain margin, then these disadvantages could be overcome.

Young, W. Robert↗

Voltage Stability Constrained Moving Target Defense Against Net Load Redistribution Attacks

Moving target defense (MTD) using distributed flexible AC transmission system (D-FACTS) devices is a promising defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation. However, all existing studies myopically perturb the reactance of D-FACTS lines without considering the system voltage stability. In this paper, we first illustrate voltage instability induced by MTDs in a three-bus system. To address this issue, we further propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow and voltage stability indices. We mathematically derive the sensitivity matrix of voltage stability index to line impedance, on which an optimization problem for maximizing voltage stability index is formulated. This framework is tested on the IEEE 14-bus and the IEEE 118-bus transmission systems, in which net load redistribution attacks are launched by sophisticated attackers. Here, the simulation results show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. We conduct case studies with and without the proposed framework under different MTD planning and operational methods. The impacts of the proposed two methods on attack detection effectiveness and system economic metrics are also revealed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying the Relationship Between Microstructure and Performance in Gadolinium-Doped Ceria Infiltrated Ni/YSZ Symmetric Cells

Infiltration of mixed ionic/electronic conducting (MIEC) nanocatalysts into the anodes of solid oxide fuel cells (SOFCs) allow the hydrogen oxidation reaction (HOR) to occur at double-phase boundaries (DPBs), rather than being confined only to the triple phase boundaries (TPBs). In this research, we use a combination of cross-sectional scanning electron microscopy (SEM), three-dimensional (3-D) reconstruction, and electrochemical methods to characterize both baseline and gadolinium-doped ceria (GDC)-infiltrated symmetric cells, with the goal of establishing a comparison between the density of electrochemically active sites in uninfiltrated and GDC-infiltrated cells. Here, electrochemical impedance spectroscopy (EIS) and distribution of relaxation times (DRT) analysis showed GDC infiltration decreased the overall polarization of the anode by a factor of 8.78 X, and decreased the resistance associated with the reactions at the TPBs/DPBs by a factor of over 21 X. By quantifying expected GDC deposition morphology in the Ni/YSZ anode it is estimated that reactions occur in the baseline cell up to 84 nm from the active TPB lines.

36 MATERIALS SCIENCE↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Power Electronics Based Self-Monitoring and Diagnosing for Photovoltaic Systems

Faults in photovoltaic (PV) systems can seriously affect the efficiency, energy yield, cost, safety, and reliability of PV plants. Condition monitoring of PV plants is, therefore, a very important approach to estimating the health condition of PV modules and power electronics in the system. However, additional hardware for PV system monitoring adds cost to the system's operation; delayed maintenance service also causes additional energy production loss. The Center for Power Electronics Systems (CPES) at the Virginia Polytechnic Institute and State University and Siemens Cooperate Research developed the online impedance measurement for a PV panel self-monitoring and diagnosing technology using the DC-DC converter connected to the panel. Small-signal impedances of a monocrystalline silicon PV panel were modeled and simulated to reflect fault conditions such as the short-circuit, hot-spot, and junction box faults. Modeling and simulation results were validated firstly using a test setup consisting of a solar simulator, a network analyzer, small-signal injectors, and a monocrystalline PV panel rated at 300 W.

14 SOLAR ENERGY↗

Frequency response of electrochemical cells

The main objective was to examine the feasibility of using frequency response techniques (1) as a tool in destructive physical analysis of batteries, particularly for estimating electrode structural parameters such as specific area, porosity, and tortuosity and (2) as a non-destructive testing technique for obtaining information such as state of charge and acceptability for space flight. The phenomena that contribute to the frequency response of an electrode include: (1) double layer capacitance; (2) Faradaic reaction resistance; (3) mass transfer of Warburg impedance; and (4) ohmic solution resistance. Nickel cadmium cells were investigated in solutions of KOH. A significant amount of data was acquired. Quantitative data analysis, using the developed software, is planned for the future.

Thomas, Daniel L.↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Computer method for design of acoustic liners for turbofan engines

A design package is presented for the specification of acoustic liners for turbofans. An estimate of the noise generation was made based on modifications of existing noise correlations, for which the inputs are basic fan aerodynamic design variables. The method does not predict multiple pure tones. A target attenuation spectrum was calculated which was the difference between the estimated generation spectrum and a flat annoyance-weighted goal attenuated spectrum. The target spectrum was combined with a knowledge of acoustic liner performance as a function of the liner design variables to specify the acoustic design. The liner design method at present is limited to annular duct configurations. The detailed structure of the liner was specified by combining the required impedance (which is a result of the previous step) with a mathematical model relating impedance to the detailed structure. The design procedure was developed for a liner constructed of perforated sheet placed over honeycomb backing cavities. A sample calculation was carried through in order to demonstrate the design procedure, and experimental results presented show good agreement with the calculated results of the method.

Minner, G. L.↗

Expert and operator perspectives on barriers to energy efficiency in data centers

Abstract It was last estimated in 2016 that data centers (DCs) comprise approximately 2% of total US electricity consumption. However, this estimate is currently being updated to account for the massive increase in computing needs due to streaming, cryptocurrency, and artificial intelligence (AI). To prevent energy consumption that tracks with increasing computing needs, it is imperative we identify energy efficiency strategies and investments beyond the low-hanging fruit solutions. In a two-phased research approach, we ask: What non-technical barriers still impede energy efficiency (EE) practices and investments in the data center sector, and what can be done to overcome these barriers? In particular, we are focused on social and organizational barriers to EE. In Phase I, we performed a literature review and found that technical solutions are abundant in the literature, but fail to address the top-down cultural shifts that need to take place in order to adapt new energy efficiency strategies. In Phase II, reported here, we interviewed 16 data center operators/experts to ground-truth our literature findings. Our interview protocols focus on three aspects of DC decision-making: procurement practices, metrics and monitoring, and perceived barriers to energy efficiency. We find that vendors are the key drivers of procurement decisions, advanced efficiency metrics are facility-specific, and there is convergence in the design of advanced facilities due to the heat density of parallelized infrastructure. Our ultimate goals for our research are to design DC decarbonization policies that target organizational structure, empower individual staff, and foster a supportive external market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detection of Chemical Precursors of Explosives

Certain selected chemicals associated with terrorist activities are too unstable to be prepared in final form. These chemicals are often prepared as precursor components, to be combined at a time immediately preceding the detonation. One example is a liquid explosive, which usually requires an oxidizer, an energy source, and a chemical or physical mechanism to combine the other components. Detection of the oxidizer (e.g. H2O2) or the energy source (e.g., nitromethane) is often possible, but must be performed in a short time interval (e.g., 5 15 seconds) and in an environment with a very small concentration (e.g.,1 100 ppm), because the target chemical(s) is carried in a sealed container. These needs are met by this invention, which provides a system and associated method for detecting one or more chemical precursors (components) of a multi-component explosive compound. Different carbon nanotubes (CNTs) are loaded (by doping, impregnation, coating, or other functionalization process) for detecting of different chemical substances that are the chemical precursors, respectively, if these precursors are present in a gas to which the CNTs are exposed. After exposure to the gas, a measured electrical parameter (e.g. voltage or current that correlate to impedance, conductivity, capacitance, inductance, etc.) changes with time and concentration in a predictable manner if a selected chemical precursor is present, and will approach an asymptotic value promptly after exposure to the precursor. The measured voltage or current are compared with one or more sequences of their reference values for one or more known target precursor molecules, and a most probable concentration value is estimated for each one, two, or more target molecules. An error value is computed, based on differences of voltage or current for the measured and reference values, using the most probable concentration values. Where the error value is less than a threshold, the system concludes that the target molecule is likely. Presence of one, two, or more target molecules in the gas can be sensed from a single set of measurements.

Li, Jing↗

Towards robust autonomous impedance spectroscopy analysis: A calibrated hierarchical Bayesian approach for electrochemical impedance spectroscopy (EIS) inversion

Distribution-based analyses, such as the distribution of relaxation times (DRT) and the distribution of diffusion times (DDT), present model-free alternatives to equivalent circuit modeling for analysis of electrochemical impedance spectroscopy (EIS) data. However, reconstructing such distributions from noisy impedance data is an ill-posed problem that must be solved with specialized inversion algorithms, requiring careful control and tuning. Furthermore, most inversion algorithms developed to date can only solve problems of limited complexity. Herein, we present a new hierarchical Bayesian method for EIS inversion, leveraging efficient algorithms for optimization and Hamiltonian Monte Carlo (HMC) sampling to solve models of arbitrary complexity. We overcome the challenge of ad-hoc parameter tuning by encoding intrinsic characteristics of the DRT and DDT into flexible prior distributions and “pre-calibrating” the model to simulated data. This approach is versatile, highly robust to noise, and provides quantitative estimates of both the error structure of the data and the uncertainty in the recovered distributions. The model is validated with simulated data to demonstrate accurate recovery of the DRT and the DDT. The method also shows promise for simultaneous recovery of multiple distributions, raising the intriguing possibility of semi-autonomous EIS analysis and ad-hoc model construction. Finally, the practical utility of the method is illustrated with experimental data. Throughout, we draw comparisons to several recently published EIS inversion methodologies.

36 MATERIALS SCIENCE↗

Leveraging the Power of SAR Observations for Forest Monitoring Systems

Earth observations from Synthetic Aperture Radar (SAR) can provide unique information related to forest structure and condition. Despite the many advantages of SAR, particularly where clouds impede optical observations, a knowledge gap has prevented the applied remote sensing community from harnessing its full potential. Here, we discuss the results of a collaboration between SERVIR, a joint program between NASA and the U.S. Agency for International Development (USAID), and SilvaCarbon, the United States’ contribution to the Global Forest Observation Initiative, to build global capacity in using SAR for forest monitoring and biomass estimation. This includes primarily the creation of 1) The SAR Handbook: Comprehensive Methodologies for Forest Monitoring and Biomass Estimation, 2) a series of international hands-on trainings and training materials, 3) quick-reference guides illustrating SAR concepts, and 4) animated videos explaining how SAR works. The SERVIR-Global community joined efforts to develop a hands-on guide to support decision-makers in the forestry community to leverage the power of SAR technology to better protect and manage forest resources. We worked with world-renowned SAR experts to provide targeted trainings and develop the SAR Handbook. This handbook consists of approachable theoretical background and applied content that contributes to filling the knowledge gap in the applied use of SAR technology for forestry applications. We hope that forest managers and remote sensing specialists will use these materials to benefit from currently available SAR datasets, as well as prepare for future SAR missions, such as NISAR and BIOMASS. Since its release on April 11, 2019, the SAR Handbook has been accessed more than 100,000 times in less than a month, demonstrating the remote sensing community’s urgent need and interest to learn and use SAR.

Herndon, Kelsey E.↗