Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Predictive Proxies of Present and Future Lightning in a Superparameterized Model

Abstract A superparameterized climate model is used to assess the global performance of several previously proposed proxies for lightning. In particular, predictors incorporating hydrometeor (ice, graupel) profiles and convective vertical velocities are compared to observations, then used to estimate changes in flash rates with global warming. The choice of microphysics parameterization is also investigated, with all predictors showing higher correlations with Lightning Imaging Sensor/Optical Transient Detector observations when using a 2‐moment scheme compared to a 1‐moment representation. All proxies generally agree in their response to warming over tropical land, with notable decreases in Africa, the Middle East, and northern South America, but disagree over oceans and the midlatitudes. The product of convective available potential energy and precipitation predicts increases over these latter areas, as do the 2‐moment ice‐based proxies, while those of the 1‐moment model tend to show decreases, highlighting the importance of cloud microphysics when using climate models to simulate lightning.

54 ENVIRONMENTAL SCIENCES↗

Quasi‐2D Perovskite Crystalline Layers for Printable Direct Conversion X‐Ray Imaging

Abstract Polycrystalline perovskite film‐based X‐ray detector is an appealing technology for assembling large scale imager by printing methods. However, thick crystalline layer without trap and solvent residual is challenging to fabricate. Here, the authors report a solution method to produce high quality quasi‐2D perovskite crystalline layers and detectors that are suitable for X‐ray imaging. By introducing n ‐butylamine iodide into methylammonium lead iodide precursor and coating at elevated temperatures, compact and crystalline layers with exceptional uniformity are obtained on both rigid and flexible substrates. Photodiodes built with the quasi‐2D layers exhibit a low dark current and stable operation under constant electrical field over 96 h in dark, and over 15 h under X‐ray irradiation. The detector responds sensitively under X‐ray, delivering a high sensitivity of 1214 µC Gy air −1 cm −2 and a sensitivity gain is observed when operated under higher fields. Finally, high resolution images are demonstrated using a single pixel device that can resolve 80–200 µm features. This work paves the path for printable direct conversion X‐ray imager development.

36 MATERIALS SCIENCE↗

1D to 2D Transition in Tellurium Observed by 4D Electron Microscopy

A new microwave-enhanced synthesis method for the production of tellurium nanostructures is reported here—with control over products from the 1D regime (sub-5 nm diameter nanowires), to nanoribbons, to the 2D tellurene regime—along with a new methodology for local statistical quantification of the crystallographic parameters of these materials at the nanometer scale. Using a direct electron detector and image-corrected microscope, large and robust 4D scanning transmission electron microscopy datasets for accurate structural analysis are obtained. These datasets allow the adaptation of quantitative techniques originally developed for X-ray diffraction (XRD) refinement analyses to transmission electron microscopy, enabling the first demonstration of sub-picometer accuracy lattice parameter extraction while also obtaining both the size of the coherent crystallite domains and the nanostrain, which is observed to decrease as nanowires transition to tellurene. This new local analysis is commensurate with global powder XRD results, indicating the robustness of both the new synthesis approach and new structural analysis methodology for future scalable production of 2D tellurene and characterization of nanomaterials.

2D materials↗

A SiPM-based optical readout system for the EIC dual-radiator RICH

Silicon photomultipliers (SiPM) are candidates selected as the potential photodetector technology for the dual-radiator Ring-Imaging Cherenkov (dRICH) detector at the future Electron-Ion Collider (EIC). SiPM are cheap devices, highly efficient and insensitive to the high magnetic field at the expected location of the sensors in the experiment. Here, on the other hand, SiPM are not radiation tolerant. Despite the integrated radiation level is expected to be moderate it should be tested whether single photon-counting capabilities and the increase in dark count rate can be kept under control to maintain the optimal dRICH detector performance across the years. The current status of the research for the EIC dRICH application and the first results on studies performed on a sample of commercial and prototype SiPM sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Ultrafast Scintillators with Core Valence Luminescence: Cs 2 MgCl 4 and Cs 3 MgCl 5

Future experiments in high energy physics and medical imaging require radiation detectors having properties which are not presently available. The main limitations arise from lack of suitable scintillation crystals. This dilemma prompts the need for research leading to the discovery of new fast and bright scintillator materials that combine unique properties to fulfil modern experiment requirements without compromises. In this work, single crystals of Cs 2 MgCl 4 and Cs 3 MgCl 5 up to 12 mm in diameter are grown via the vertical Bridgman method. Scintillation properties are reported for the first time, and core valence luminescence is observed for both compounds. X-ray excited radioluminescence emission of Cs 2 MgCl 4 is centered at 295 nm, with a scintillation decay time of 2.25 ± 0.05 ns and relatively high core-valence light yield of 2,200 ± 110 ph/MeV. Cs 3 MgCl 5 has two main emission peaks centered at 242 nm and 302 nm, decay time of 1.46 ± 0.05 ns, and light yield of 1,340 ± 70 ph/MeV. The better coincidence time resolution (CTR) is obtained with Cs 2 MgCl 4 , which is measured to be 129 ± 4 ps FWHM. Density functional theory (DFT) calculations are also performed and provide supporting evidence that the observed scintillation originates from core valence luminescence. Furthermore, the combination of speed and brightness of these new scintillators could be useful for fast timing applications in which moderately dense materials are required.

36 MATERIALS SCIENCE↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Small animal PET: a review of what we have done and where we are going

Abstract Small animal research is an essential tool in studying both pharmaceutical biodistribution and disease progression over time. Furthermore, through the rapid development of in vivo imaging technology over the last few decades, small animal imaging (also referred to as preclinical imaging) has become a mainstay for all fields of biologic research and a center point for most preclinical cancer research. Preclinical imaging modalities include optical, MRI and MRS, microCT, small animal PET, ultrasound, and photoacoustic, each with their individual strengths. The strong points of small animal PET are its translatability to the clinic; its quantitative imaging capabilities; its whole-body imaging ability to dynamically trace functional/biochemical processes; its ability to provide useful images with only nano- to pico- molar concentrations of administered compounds; and its ability to study animals serially over time. This review paper gives an overview of the development and evolution of small animal PET imaging. It provides an overview of detector designs; system configurations; multimodality PET imaging systems; image reconstruction and analysis tools; and an overview of research and commercially available small animal PET systems. It concludes with a look toward developing technologies/methodologies that will further enhance the impact of small animal PET imaging on medical research in the future.

Engineering↗

pyAXEAP1-GUI package

SF-25-076 pyAXEAP1-GUI package is an X-ray emission spectroscopy (XES) data analysis package in the Python language. It can transfer the collected images from a 2D detector into spectra and display XES and RXES data as 3Dimages, 2D images and 1D profiles.

Berno, Alexander↗

Exploring the Great Pyramid

For centuries, the pyramids at Giza have been the object of frequent speculation and study. L. Alvarez et al. in 1970 and the ScanPyramids collaboration in 2017 have very successfully implemented HEP detector technology to image the pyramid of Khafre and the Great Pyramid of Khufu, respectively. Numerous questions about Khufu’s structure remain, however. The EGP project aims to undertake a new study of this enigmatic monument’s interior by applying high-resolution tomographic imaging and reconstruction, which will permit a detailed understanding of internal variations in density and may offer insight regarding exactly how Egypt’s largest pyramid was built.

43 PARTICLE ACCELERATORS↗

Evaluation of Getters for Helium Purification

• Helium-3 is a vital commodity in both medical and defense applications • Ultra-low cryogenic coolant (MRI imaging, etc.) • Neutron detectors • Being investigated as possible fusion fuel • Managed and distributed by DOE-OS • New PDRD project exploring helium isotope separation • Limited supply • Only available from tritium decay • Prohibitively difficult to separate from helium-4 • SRS Tritium Facility provides a steady source

Angelette, Lucas M.↗

High-Multiplicity Muon Airshower Analysis at NOvA Far Detector

We process and analyze muon airshower data from the NOvA far detector using various image processing algorithms, such as Fast Fourier Transformation, and Hough line transformation. From the processed event images, we calculate multiple parameters for our study. We are looking for physics features, including East-West Asymmetry, anisotropies in right ascension, and seasonal variation. Additionally, we have developed an algorithm to count the multiplicity of muons in the airshower events using the single muon data.

Lima, Aklima Khanam [Syracuse U.]↗

Capacitively Coupled LAPPDs with 2D Pixelated Readout Planes for Time of Flight and Ring Imaging Cherenkov Applications

Large Area Picosecond Photon Detectors (LAPPDs) are micro-channel plate based photosensors featuring hundreds of square centimeters of sensitive area in a single package and capable of providing timing resolution on the order of 50 ps for single photon detection. However, LAPPDs currently do not exist in finely pixelated 2D readout configurations which, in addition to ighresolution timing, would also provide high spatial resolution required for Ring Imaging CHerenkov (RICH) detectors. One of the recent LAPPD models (Gen II) provides the opportunity to overcome the lack of pixellation by coupling an external readout to the sealed detector itself. The readout plane in this case is a simple printed circuit board (PCB) that can be laid out in a custom application-specific way for 1D or 2D sensitive area pixellation. This allows for a much shorter readout-plane prototyping cycle and provides unprecedented flexibility in choosing an appropriate segmentation that can be optimized for any particular detector need in terms of pad size, orientation, and shape.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beam­line 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

36 MATERIALS SCIENCE↗

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.

ENERGY STORAGE,HYDROGEN↗

Machine learning pipeline for denoising low signal-to-noise ratio and out-of-distribution transmission electron microscopy datasets

High-resolution transmission electron microscopy (HRTEM) is crucial for observing material’s structural and morphological evolution at Angstrom scales, but the electron beam can alter these processes. Devices such as CMOS-based direct-electron detectors operating in electron-counting mode can be utilized to substantially reduce the electron dosage. However, the resulting images often lead to a low signal-to-noise ratio, which requires frame integration that sacrifices temporal resolution. Several machine learning (ML) models have been recently developed to successfully denoise HRTEM images. Yet, these models are often computationally expensive, and their inference speeds on GPUs are outpaced by the imaging speed of advanced detectors, precluding in situ analysis. Furthermore, the performance of these denoising models on datasets with imaging conditions that deviate from the training datasets has not been evaluated. To mitigate these gaps, we propose a new self-supervised ML denoising pipeline specifically designed for time-series HRTEM images. This pipeline integrates a blind-spot convolution neural network with pre-processing and post-processing steps, including drift correction and low-pass filtering. Results demonstrate that our model outperforms various other ML and non-ML denoising methods in noise reduction and contrast enhancement, leading to improved visual clarity of atomic features. Additionally, the model is drastically faster than U-Net-based ML models and demonstrates excellent out-of-distribution generalization. The model’s computational inference speed is in the order of milliseconds per image, rendering it suitable for application in in-situ HRTEM experiments.

36 MATERIALS SCIENCE↗

Characterizing electron-collecting CdTe for use in a 77 ns burst-rate imager

The Keck-PAD (pixel array detector) was developed at Cornell as a burst-rate imager capable of recording images from successive electron bunches (153 ns period) from the Advanced Photon Source (APS). Both Si and hole-collecting Schottky CdTe have been successfully bonded to this ASIC (application-specific integrated circuit) and used with this frame rate. The facility upgrades at the APS will lower the bunch period to 77 ns, which will require modifications to the Keck-PAD electronics to image properly at this reduced period. In addition, operation at high X-ray energies will require a different sensor material having a shorter charge collection time. For the target energy of 40 keV for this project, simulations have shown that electron-collecting CdTe should allow >90% charge collection within 35 ns. This collection time will be sufficient to sample the signal from one frame and prepare for the next. 750 µm-thick electron-collecting Schottky CdTe has been obtained from Acrorad and bonded to two different charge-integrating ASICs developed at Cornell, the Keck-PAD and the CU-APS-PAD. Carrier mobility has been investigated using the detector response to single X-ray bunches at the Cornell High Energy Synchrotron Source and to a pulsed optical laser. The tests indicate that the collection time will meet the requirements for 77 ns imaging.

36 MATERIALS SCIENCE↗

Scalable and accurate multi-GPU-based image reconstruction of large-scale ptychography data

Abstract While the advances in synchrotron light sources, together with the development of focusing optics and detectors, allow nanoscale ptychographic imaging of materials and biological specimens, the corresponding experiments can yield terabyte-scale volumes of data that can impose a heavy burden on the computing platform. Although graphics processing units (GPUs) provide high performance for such large-scale ptychography datasets, a single GPU is typically insufficient for analysis and reconstruction. Several works have considered leveraging multiple GPUs to accelerate the ptychographic reconstruction. However, most of these works utilize only the Message Passing Interface to handle the communications between GPUs. This approach poses inefficiency for a hardware configuration that has multiple GPUs in a single node, especially while reconstructing a single large projection, since it provides no optimizations to handle the heterogeneous GPU interconnections containing both low-speed (e.g., PCIe) and high-speed links (e.g., NVLink). In this paper, we provide an optimized intranode multi-GPU implementation that can efficiently solve large-scale ptychographic reconstruction problems. We focus on the maximum likelihood reconstruction problem using a conjugate gradient (CG) method for the solution and propose a novel hybrid parallelization model to address the performance bottlenecks in the CG solver. Accordingly, we have developed a tool, called PtyGer ( Pty chographic G PU(multipl e )-based r econstruction), implementing our hybrid parallelization model design. A comprehensive evaluation verifies that PtyGer can fully preserve the original algorithm’s accuracy while achieving outstanding intranode GPU scalability.

97 MATHEMATICS AND COMPUTING↗