Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image system design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

MO-FG-209-02: Development of a Virtual Breast Phantom From a Multi-Modality Perspective

This symposium will review recent advances in the simulation methods for evaluation of novel breast imaging systems – the subject of AAPM Task Group TG234. Our focus will be on the various approaches to development and validation of software anthropomorphic phantoms and their use in the statistical assessment of novel imaging systems using such phantoms along with computational models for the x-ray image formation process. Due to the dynamic development and complex design of modern medical imaging systems, the simulation of anatomical structures, image acquisition modalities, and the image perception and analysis offers substantial benefits of reduced cost, duration, and radiation exposure, as well as the known ground-truth and wide variability in simulated anatomies. For these reasons, Virtual Clinical Trials (VCTs) have been increasingly accepted as a viable tool for preclinical assessment of x-ray and other breast imaging methods. Activities of TG234 have encompassed the optimization of protocols for simulation studies, including phantom specifications, the simulated data representation, models of the imaging process, and statistical assessment of simulated images. The symposium will discuss the state-of-the-science of VCTs for novel breast imaging systems, emphasizing recent developments and future directions. Presentations will discuss virtual phantoms for intermodality breast imaging performance comparisons, extension of the breast anatomy simulation to the cellular level, optimized integration of the simulated imaging chain, and the novel directions in the observer models design. Learning Objectives: Review novel results in developing and applying virtual phantoms for inter-modality breast imaging performance comparisons; Discuss the efforts to extend the computer simulation of breast anatomy and pathology to the cellular level; Summarize the state of the science in optimized integration of modules in the simulated imaging chain; Compare novel directions in the design of observer models for task based validation of imaging systems. PB: Research funding support from the NIH, NSF, and Komen for the Cure; NIH funded collaboration with Barco, Inc. and Hologic, Inc.; Consultant to Delaware State Univ. and NCCPM, UK. AA: Employed at Barco Healthcare.; P. Bakic, NIH: (NIGMS P20 #GM103446, NCI R01 #CA154444); M. Das, NIH Research grants.

60 APPLIED LIFE SCIENCES↗

MO-FG-209-05: Towards a Feature-Based Anthropomorphic Model Observer

This symposium will review recent advances in the simulation methods for evaluation of novel breast imaging systems – the subject of AAPM Task Group TG234. Our focus will be on the various approaches to development and validation of software anthropomorphic phantoms and their use in the statistical assessment of novel imaging systems using such phantoms along with computational models for the x-ray image formation process. Due to the dynamic development and complex design of modern medical imaging systems, the simulation of anatomical structures, image acquisition modalities, and the image perception and analysis offers substantial benefits of reduced cost, duration, and radiation exposure, as well as the known ground-truth and wide variability in simulated anatomies. For these reasons, Virtual Clinical Trials (VCTs) have been increasingly accepted as a viable tool for preclinical assessment of x-ray and other breast imaging methods. Activities of TG234 have encompassed the optimization of protocols for simulation studies, including phantom specifications, the simulated data representation, models of the imaging process, and statistical assessment of simulated images. The symposium will discuss the state-of-the-science of VCTs for novel breast imaging systems, emphasizing recent developments and future directions. Presentations will discuss virtual phantoms for intermodality breast imaging performance comparisons, extension of the breast anatomy simulation to the cellular level, optimized integration of the simulated imaging chain, and the novel directions in the observer models design. Learning Objectives: Review novel results in developing and applying virtual phantoms for inter-modality breast imaging performance comparisons; Discuss the efforts to extend the computer simulation of breast anatomy and pathology to the cellular level; Summarize the state of the science in optimized integration of modules in the simulated imaging chain; Compare novel directions in the design of observer models for task based validation of imaging systems. PB: Research funding support from the NIH, NSF, and Komen for the Cure; NIH funded collaboration with Barco, Inc. and Hologic, Inc.; Consultant to Delaware State Univ. and NCCPM, UK. AA: Employed at Barco Healthcare.; P. Bakic, NIH: (NIGMS P20 #GM103446, NCI R01 #CA154444); M. Das, NIH Research grants.

60 APPLIED LIFE SCIENCES↗

UT-NE Radiation Instrumentation Research Group Meeting: An Update on Progress

The purpose of this project is to design a system to image large and/or thick objects with high dynamic ranges using an intensified, charge coupled device (CCD) camera and a fast-pulsed, high energy neutron source; Improve image resolution by reducing scatter; and Design ultra-fast scintillator using nanotechnology to allow for better timing (and thus better scatter rejection).

07 ISOTOPE AND RADIATION SOURCES↗

MO-FG-303-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Automating LINAC QA: Design and Testing of An Image Acquisition and Processing System Utilizing a Combination of Radioluminescent Phosphors, Embedded X-Ray Markers and Optical Measurements

Purpose: The recent development of phosphors to visualize radiation beams from linear accelerators (LINAC) offers a unique opportunity for evaluating radiation fields within the context of the treatment space. The purpose of this study was to establish an automated, self-calibrating prototype system for performing quality assurance (QA) measurements. Methods: A thin layer of Gd{sub 2}O{sub 2}S:Tb phosphor and fiducial markers were embedded on several planar faces of a custom-designed phantom. The phantom was arbitrarily placed near iso-center on the couch of a LINAC equipped with on-board megavoltage (MV) and kilovoltage (kV) imagers. A plan consisting of several beams and integrated image acquisitions was delivered. Images of the phantom were collected throughout the delivery. Salient features, such as fiducials, crosshairs and beam edges were then extracted from these images used to calibrate the system, adjust for variations in phantom placement, and perform measurements. Beam edges were visualized by imaging the light generated by the phosphor on the phantom enabling direct comparison with the light field and laser locations. Registration of MV, kV and optical image data was performed using the embedded fiducial markers, enabling comparison of imaging center locations. Measurements specified by TG-142 were calculated and compared with those obtained from a commercially available QA system. Results: The system was able to automatically extract the location of the fiducials, lasers, light field and radiation field from the acquired images regardless of phantom positioning. It was also able to automatically identify the locations of fiducial markers on kV and MV images. All collected measurements were within TG-142 guidelines. The difference between the prototype and commercially available system were less than 0.2 mm. Conclusion: The prototype system demonstrated the capability of accurately and autonomously evaluating various TG-142 parameters independent of operator input and phantom setup.

60 APPLIED LIFE SCIENCES↗

Soft X-Ray Imaging Design and Analysis Methods on DIII-D

A new tangential 2D Soft X-Ray Imaging System (SXRIS) is being designed to examine the edge magnetic island structure in the lower X-point region of DIII-D. A synthetic diagnostic calculation coupled to 3D emissivity estimates is used to generate phantom images. Phillips-Tikhonov regularization is used to invert the phantom images for comparison to the original emissivity model. Noise level, island size, and equilibrium accuracy are scanned to assess the feasibility of detecting edge island structures. Models of typical DIII-D discharges indicate integration times > 1 ms with accurate equilibrium reconstruction are needed for small island (< 3 cm) detection.

Shafer, Morgan W↗

X Ray, Far, and Extreme Ultraviolet Coatings for Space Applications

The idea of utilizing imaging mirrors as narrow band filters constitutes the basis of the design of extreme ultraviolet imagers operating at 58.4 nm and 83.4 nm. The net throughput of both imaging-filtering systems is better than 20 percent. The superiority of the EUV self-filtering camera/telescope becomes apparent when compared to previously theoretically designed 83.4-nm filtering-imaging systems, which yielded transmissions of less than a few percent and therefore less than 0.1 percent throughput when combined with at least two imaging mirrors. Utilizing the self-filtering approach, instruments with similar performances are possible for imaging at other EUV wavelengths, such as 30.4 nm. The self-filtering concept is extended to the X-ray region where its application can result in the new generation of X-ray telescopes, which could replace current designs based on large and heavy collimators.

Zukic, M.↗

Performance modeling & simulation of complex systems (A systems engineering design & analysis approach)

Modeling of the Multi-mission Image Processing System (MIPS) will be described as an example of the use of a modeling tool to design a distributed system that supports multiple application scenarios. This paper examines: (a) modeling tool selection, capabilities, and operation (namely NETWORK 2.5 by CACl), (b) pointers for building or constructing a model and how the MIPS model was developed, (c) the importance of benchmarking or testing the performance of equipment/subsystems being considered for incorporation the design/architecture, (d) the essential step of model validation and/or calibration using the benchmark results, (e) sample simulation results from the MIPS model, and (f) how modeling and simulation analysis affected the MIPS design process by having a supportive and informative impact.

Hall, Laverne↗

Image gathering and digital restoration for fidelity and visual quality

The fidelity and resolution of the traditional Wiener restorations given in the prevalent digital processing literature can be significantly improved when the transformations between the continuous and discrete representations in image gathering and display are accounted for. However, the visual quality of these improved restorations also is more sensitive to the defects caused by aliasing artifacts, colored noise, and ringing near sharp edges. In this paper, these visual defects are characterized, and methods for suppressing them are presented. It is demonstrated how the visual quality of fidelity-maximized images can be improved when (1) the image-gathering system is specifically designed to enhance the performance of the image-restoration algorithm, and (2) the Wiener filter is combined with interactive Gaussian smoothing, synthetic high edge enhancement, and nonlinear tone-scale transformation. The nonlinear transformation is used primarily to enhance the spatial details that are often obscurred when the normally wide dynamic range of natural radiance fields is compressed into the relatively narrow dynamic range of film and other displays.

Huck, Friedrich O.↗

Onboard processing for future space-borne imaging systems

There is a strong rationale for increasing the rate of information return from imaging class experiments aboard both terrestrial and planetary spacecraft. Future imaging systems will be designed with increased spatial resolution, broader spectral range and more spectral channels (or higher spectral resolution). The data rate implied by these improved performance characteristics can be expected to grow more rapidly than the projected telecommunications capability. One solution to this dilemma is the use of improved onboard data processing. The use of onboard classification processing in a multispectral imager can result in orders of magnitude increase in information transfer for very specific types of imaging tasks. Several of these processing functions are included in the conceptual design of an Infrared Multispectral Imager which would map the spatial distribution of characteristic geologic features associated with deposits of economic minerals.

Wellman, J. B.↗

A VLSI Processor Design of Real-Time Data Compression for High-Resolution Imaging Radar

For the high-resolution imaging radar systems, real-time data compression of raw imaging data is required to accomplish the science requirements and satisfy the given communication and storage constraints. The Block Adaptive Quantizer (BAQ) algorithm and its associated VLSI processor design have been developed to provide a real-time data compressor for high-resolution imaging radar systems.

data compression VLSI processor design imaging rad↗

Electronically Steered Thinned Array Radiometer (ESTAR) system design, calibration, and sensitivity

The ESTAR system, an imaging L-band radiometer designed to provide measurements of soil moisture from space, is described. The large aperture size dictated by the resolution requirement (10 km or less) suggests the use of aperture synthesis, and plans to have ESTAR operate in low earth orbit require that the synthesis be performed in the short data acquisition time permitted by satellite motion. Two forms of ESTAR are described. ESTAR-0 is to be an airborne prototype designed for proof of concept; it will image a line of eight adjacent pixels with 8 degree spatial resolution of 0.1 degree Kelvin temperature resolution, given 1 sec integration time. ESTAR-1 is the satellite version to operate from space. A tentative sensor design will image a line of 128 0.5 degree pixels with 2.0 degree K resolution assuming 0.7 sec integration at 700 km altitude.

Ruf, C.↗

The high resolution imaging spectrometer (HIRIS) for EOS

The high resolution imaging spectrometer (HIRIS) designed for the Earth Observing System (EOS) is designed to acquire images in 192 spectral bands simultaneously in the 0.4-2.5-micron wavelength region. HIRIS is a targeting rather than a continuous acquisition instrument and obtains high-spatial- and spectral-resolution images in a 30-km swath with a 30-m ground instantaneous field of view (GIFOV) in vertical viewing. Pointing will allow image acquisition at -30 to +60 deg along-track and +/-24 deg cross-track. The raw data rate of the instrument is 512 Mbs. The high spectral resolution will make it possible to identify many surficial materials such as rocks, soils, and suspended matter in water directly. HIRIS also offers the possibility of studying biochemical process in vegetation canopies.

Goetz, Alexander F. H.↗

Analyzer-based phase-contrast imaging system using a micro focus x-ray source

Here we describe a new in-laboratory analyzer based phase contrast-imaging (ABI) instrument using a conventional X-ray tube source (CXS) aimed at bio-medical imaging applications. Phase contrast-imaging allows visualization of soft tissue details usually obscured in conventional X-ray imaging. The ABI system design and major features are described in detail. The key advantage of the presented system, over the few existing CXS ABI systems, is that it does not require high precision components, i.e., CXS, X-ray detector, and electro-mechanical components. To overcome a main problem introduced by these components, identified as temperature stability, the system components are kept at a constant temperature inside of three enclosures, thus minimizing the electrical and mechanical thermal drifts. This is achieved by using thermoelectric (Peltier) cooling/heating modules that are easy to control precisely. For CXS we utilized a microfocus X-ray source with tungsten (W) anode material. In addition the proposed system eliminates tungsten's multiple spectral lines by selecting monochromator crystal size appropriately therefore eliminating need for the costly mismatched, two-crystal monochromator. The system imaging was fine-tuned for tungsten Kα{sub 1} line with the energy of 59.3 keV since it has been shown to be of great clinical significance by a number of researchers at synchrotron facilities. In this way a laboratory system that can be used for evaluating and quantifying tissue properties, initially explored at synchrotron facilities, would be of great interest to a larger research community. To demonstrate the imaging capability of our instrument we use a chicken thigh tissue sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗