Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The effects of window shape and reticle presence on performance in a vertical alignment task

This study was conducted to evaluate the effect of selected interior work-station orientational cuing upon the ability to align a target image with local vertical in the frontal plane. Angular error from gravitational vertical in an alignment task was measured for 20 observers viewing through two window shapes (square, round), two initial orientations of a computer-generated space shuttle image, and the presence or absence of a stabilized optical alignment reticle. In terms of overall accuracy, it was found that observer error was significantly smaller for the square window and reticle-present conditions than for the round window and reticle-absent conditions. Response bias data reflected an overall tendency to undershoot and greater variability of response in the round window/no reticle condition. These results suggest that environmental cuing information, such as that provided by square window frames and alignment reticles, may aid in subjective orientation and increase accuracy of response in a Space Station proximity operations alignment task.

Rosenberg, Erika L.↗

Supporting data for "Frozen flume experiments indicate rapid permafrost riverbank erosion depends on bank roughness"

This dataset contains supporting files detailing five frozen flume experiments conducted at the Caltech Earth Surface Dynamics Laboratory to investigate rates of ablation-limited permafrost riverbank erosion under controlled conditions. Water flowed past a bank of saturated, frozen sand and ice and gradually eroded the bank by thawing pore ice and immediately entraining sand and washing it downstream. Experiments were scaled for flow hydraulics and heat transfer allowing comparisons between our results and natural permafrost riverbanks. For each experiment, we measured the initial and final sand bank topography using a Keyence laser scanner, water surface slope at 3-min intervals throughout the experiment using a Massa sonar scanner, bank erosion using 10-sec overhead timelapse imagery taken by an overhead camera, water and bank temperature using thermistors frozen into the sand bank and sampling at 2 Hz, and water discharge using an in-line flow meter. We include calibration data for the carriage (engineered by the Saint Anthony Falls Laboratory) used to make sonar and laser topography measurements. We also include calibration data for temperature sensors, water discharge measurements, and images of a regular grid placed in the flume to align overhead camera images with the carriage datum. Grain size analysis for the channel bed (gravel) was produced using a pebble count and bank sand was measured using a Camsizer X2. In addition to the five frozen experiments, we include sonar scans of water surface slope and Keyence scans of bed and bank topography for calibration experiments ran with an immobile gravel bank and bed.

54 ENVIRONMENTAL SCIENCES↗

Segmented Mirror Image Degradation Due to Surface Dust, Alignment and Figure

In 1996 an algorithm was developed to include the effects of surface roughness in the calculation of the point spread function of a telescope mirror. This algorithm has been extended to include the effects of alignment errors and figure errors for the individual elements, and an overall contamination by surface dust. The final algorithm builds an array for a guard-banded pupil function of a mirror that may or may not have a central hole, a central reflecting segment, or an outer ring of segments. The central hole, central reflecting segment, and outer ring may be circular or polygonal, and the outer segments may have trimmed comers. The modeled point spread functions show that x-tilt and y-tilt, or the corresponding R-tilt and theta-tilt for a segment in an outer ring, is readily apparent for maximum wavefront errors of 0.1 lambda. A similar sized piston error is also apparent, but integral wavelength piston errors are not. Severe piston error introduces a focus error of the opposite sign, so piston could be adjusted to compensate for segments with varying focal lengths. Dust affects the image principally by decreasing the Strehl ratio, or peak intensity of the image. For an eight-meter telescope a 25% coverage by dust produced a scattered light intensity of 10(exp -9) of the peak intensity, a level well below detectability.

Schreur, Julian J.↗

TU-AB-BRA-02: An Efficient Atlas-Based Synthetic CT Generation Method

Purpose: A major obstacle for MR-only radiotherapy is the need to generate an accurate synthetic CT (sCT) from MR image(s) of a patient for the purposes of dose calculation and DRR generation. We propose here an accurate and efficient atlas-based sCT generation method, which has a computation speed largely independent of the number of atlases used. Methods: Atlas-based sCT generation requires a set of atlases with co-registered CT and MR images. Unlike existing methods that align each atlas to the new patient independently, we first create an average atlas and pre-align every atlas to the average atlas space. When a new patient arrives, we compute only one deformable image registration to align the patient MR image to the average atlas, which indirectly aligns the patient to all pre-aligned atlases. A patch-based non-local weighted fusion is performed in the average atlas space to generate the sCT for the patient, which is then warped back to the original patient space. We further adapt a PatchMatch algorithm that can quickly find top matches between patches of the patient image and all atlas images, which makes the patch fusion step also independent of the number of atlases used. Results: Nineteen brain tumour patients with both CT and T1-weighted MR images are used as testing data and a leave-one-out validation is performed. Each sCT generated is compared against the original CT image of the same patient on a voxel-by-voxel basis. The proposed method produces a mean absolute error (MAE) of 98.6±26.9 HU overall. The accuracy is comparable with a conventional implementation scheme, but the computation time is reduced from over an hour to four minutes. Conclusion: An average atlas space patch fusion approach can produce highly accurate sCT estimations very efficiently. Further validation on dose computation accuracy and using a larger patient cohort is warranted. The author is a full time employee of Elekta, Inc.

60 APPLIED LIFE SCIENCES↗

CBCT with specification of imaging dose and CNR by anatomical volume of interest

Purpose: A novel method has been developed for volume of interest (VOI) cone-beam CT (CBCT) imaging using a 2.35 MV/Carbon target linac imaging beam line combined with dynamic multileaf collimator sequences. Methods: The authors demonstrate the concept of acquisition of multiple, separate imaging volumes, where volumes can be either completely separated or nested, and are associated with predetermined imaging dose and contrast-to-noise ratio (CNR) characteristics. Two individual MLC sequences were established in the planning system (Eclipse, Varian Medical) to collimate the beam according to a defined inner VOI (e.g., containing a target volume under image guidance) and an outer VOI (e.g., including surrounding landmarks or organs-at-risk). MLC sequences were interleaved as a function of gantry angle to produce a reconstructed CBCT image with nested VOIs. By controlling the ratio of inner-to-outer ratio of MLC segments (and thus Monitor Units) during acquisition, the relative dose and CNR in the two volumes can be controlled. Inner-to-outer ratios of 2:1 to 6:1 were examined. Results: The concept was explored using an anatomical head phantom to assess image quality. A geometric phantom was used to quantify absolute dose and CNR values for the various sequences. The authors found that the dose in the outer VOI decreased by a functional relationship dependent on the inner-to-outer sequence ratio, while the CNR varied by the square root of dose, as expected. Conclusions: In this study the authors demonstrate flexibility in VOI CBCT by tailoring the imaging dose and CNR distribution in separate volumes within the patient anatomy. This would allow for high quality imaging of a target volume for alignment purposes, with simultaneous low dose imaging of the surrounding anatomy (e.g., for coregistration)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Alignment Test System for AXAF-I's High Resolution Mirror Assembly

The AXAF-1 High Resolution Mirror Assembly (HRMA) consists of four nested mirror pairs of Wolter Type-1 grazing incidence optics. The HRMA assembly and alignment will take place in a vibration-isolated, cleanliness class 100, 18 meter high tower at an Eastman Kodak Company facility in Rochester, NY. Each mirror pair must be aligned such that its image is coma-free, and the four pairs must be aligned such that their images are coincident. In addition, both the HRMA optical axis and focal point must be precisely known with respect to physical references on the HRMA. The alignment of the HRMA mirrors is measured by the HRMA Alignment Test System (HATS), which is an integral part of the tower facility. The HATS is configured as a double-pass, autocollimating Hartmann test where each mirror aperture is scanned to determine the state of alignment. This paper will describe the design and operation of the HATS.

Waldman, Mark↗

Ducted fuel injection system alignment device

An alignment device for a ducted fuel injection system comprising a mounting block removably attachable to a duct of the ducted fuel injection system. The mounting block can include a passageway extending therethrough. The passageway can align with the duct when the mounting block is attached to the duct. The alignment device further comprises an imaging device configured to capture an image viewing through the duct toward an outlet of a fuel injector. A portion of the imaging device can extend in the passageway. The alignment device additionally comprises a centering structure configured to align a portion of the imaging device with a central axis of the duct. The image captured by the imaging device can be configured for use aligning a position of an outlet of a fuel injector with respect to a position of the duct.

Nilsen, Christopher William↗

2.2 micron image of 3C 368 at z = 1.13, a galaxy with aligned radio and stellar axes

A K-band IR image of the z = 1.13 radio galaxy 3C 368, one of the brightest examples of the recently discovered phenomenon of alignment between the optical and radio axes of powerful distant radio galaxies, is presented. The observations show that the IR morphology is also elongated and aligned along the optical and radio axes, but is not coincident with the radio emission. Various mechanisms for producing the IR and optical flux and the resultant constraints on the origin of the alignment effect in high-redshift radio galaxies are discussed. The most likely explanation is that the emission is produced mainly by young stars formed by interaction of the radio source with the ISM. The IR flux is then interpreted as dominated by a population of red supergiants. Independent of the origin of the emission, the observed alignment implies that powerful radio galaxies at high redshifts are distant from giant ellipticals, even in the IR. Hence, attempts to derive a cosmological 'standard candle' using studies which combine these two types of galaxies are likely to be invalid.

Chambers, K. C.↗

Physically motivated global alignment method for electron tomography

Electron tomography is widely used for nanoscale determination of 3-D structures in many areas of science. Determining the 3-D structure of a sample from electron tomography involves three major steps: acquisition of sequence of 2-D projection images of the sample with the electron microscope, alignment of the images to a common coordinate system, and 3-D reconstruction and segmentation of the sample from the aligned image data. The resolution of the 3-D reconstruction is directly influenced by the accuracy of the alignment, and therefore, it is crucial to have a robust and dependable alignment method. In this paper, we develop a new alignment method which avoids the use of markers and instead traces the computed paths of many identifiable ‘local’ center-of-mass points as the sample is rotated. Compared with traditional correlation schemes, the alignment method presented here is resistant to cumulative error observed from correlation techniques, has very rigorous mathematical justification, and is very robust since many points and paths are used, all of which inevitably improves the quality of the reconstruction and confidence in the scientific results.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Collimator with attachment mechanism and system

A self-aligning collimator for a radiation imaging device that is secured and aligned through the use of a plurality of small magnets. The collimator allows for the rapid exchange, removal, or addition of collimators for the radiation imaging device without the need for tools. The accompanying method discloses the use of magnets and accompanying magnetic fields to align and secure collimators in a radiation imaging assembly.

47 OTHER INSTRUMENTATION↗

Making a Back-Illuminated Imager with Back-Side Contact and Alignment Markers

A design modification and a fabrication process that implements the modification have been conceived to solve two problems encountered in the development of back-illuminated, back-sidethinned complementary metal oxide/ semiconductor (CMOS) image-detector integrated circuits. The two problems are (1) how to form metal electrical-contact pads on the back side that are electrically connected through the thickness in proper alignment with electrical contact points on the front side and (2) how to provide alignment keys on the back side to ensure proper registration of backside optical components (e.g., microlenses and/or color filters) with the front-side pixel pattern. The essence of the design modification is to add metal plugs that extend from the desired front-side locations through the thickness and protrude from the back side of the substrate. The plugs afford the required front-to-back electrical conduction, and the protrusions of the plugs serve as both the alignment keys and the bases upon which the back-side electrical-contact pads can be formed.

Pain, Bedabrata↗

Alignment, orientation, and Coulomb explosion of difluoroiodobenzene studied with the pixel imaging mass spectrometry (PImMS) camera

Laser-induced adiabatic alignment and mixed-field orientation of 2,6-difluoroiodobenzene (C 6 H 3 F 2 I) molecules are probed by Coulomb explosion imaging following either near-infrared strong-field ionization or extreme-ultraviolet multi-photon inner-shell ionization using free-electron laser pulses. The resulting photoelectrons and fragment ions are captured by a double-sided velocity map imaging spectrometer and projected onto two position-sensitive detectors. The ion side of the spectrometer is equipped with a pixel imaging mass spectrometry camera, a time-stamping pixelated detector that can record the hit positions and arrival times of up to four ions per pixel per acquisition cycle. Thus, the time-of-flight trace and ion momentum distributions for all fragments can be recorded simultaneously. Finally, we show that we can obtain a high degree of one-and three-dimensional alignment and mixed-field orientation and compare the Coulomb explosion process induced at both wavelengths

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthetic Aperture Radar Image Geolocation Using Fiducial Images

Synthetic Aperture Radar (SAR) creates imagery of the earth’s surface from airborne or spaceborne radar platforms. However, the nature of any radar is to geolocate its echo data, i.e., SAR images, relative to its own measured radar location. Acceptable accuracy and precision of such geolocation can be quite difficult to achieve, and is limited by any number of parameters. However, databases of geolocated earth imagery do exist, often using other imaging modalities, with Google Earth being one such example. These can often be much more accurate than what might be achievable by the radar itself. Consequently, SAR images may be aligned to some higher accuracy database, thereby improving the geolocation of features in the SAR image. Examples offer anecdotal evidence of the viability of such an approach.

47 OTHER INSTRUMENTATION↗

Optical alignment equipment and methods for visible and IR imaging meteorological radiometer

This paper describes the test equipment required for precise IR and visible channel microradian alignments for geosynchronous orbiting meteorological instruments. The test equipment design criteria, design, function and use are explained in detail. Wave front error measurements, vibration isolation, thermal compensation and stress free mounting configurations are described.

Herendeen, R.↗

An edge-on galaxy model for Q 0957 + 561

An edge-on disk galaxy would act as a lens to produce two images which are aligned. Such a model would explain the observed features of Q0957 + 561A, and B. The third image is expected to be very faint and so neat to center of the lensing galaxy as to be unobservable.

Zheng, W.↗

Assessment of contrast enhanced respiration managed cone-beam CT for image guided radiotherapy of intrahepatic tumors

Purpose: Contrast enhancement and respiration management are widely used during image acquisition for radiotherapy treatment planning of liver tumors along with respiration management at the treatment unit. However, neither respiration management nor intravenous contrast is commonly used during cone-beam CT (CBCT) image acquisition for alignment prior to radiotherapy. In this study, the authors investigate the potential gains of injecting an iodinated contrast agent in combination with respiration management during CBCT acquisition for liver tumor radiotherapy. Methods: Five rabbits with implanted liver tumors were subjected to CBCT with and without motion management and contrast injection. The acquired CBCT images were registered to the planning CT to determine alignment accuracy and dosimetric impact. The authors developed a simulation tool for simulating contrast-enhanced CBCT images from dynamic contrast enhanced CT imaging (DCE-CT) to determine optimal contrast injection protocols. The tool was validated against contrast-enhanced CBCT of the rabbit subjects and was used for five human patients diagnosed with hepatocellular carcinoma. Results: In the rabbit experiment, when neither motion management nor contrast was used, tumor centroid misalignment between planning image and CBCT was 9.2 mm. This was reduced to 2.8 mm when both techniques were employed. Tumors were not visualized in clinical CBCT images of human subjects. Simulated contrast-enhanced CBCT was found to improve tumor contrast in all subjects. Different patients were found to require different contrast injections to maximize tumor contrast. Conclusions: Based on the authors’ animal study, respiration managed contrast enhanced CBCT improves IGRT significantly. Contrast enhanced CBCT benefits from patient specific tracer kinetics determined from DCE-CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and alignment of an all-spherical unobscured four-mirror image relay for an ultra-broadband sub-petawatt laser

We describe the design and alignment of an unobscured reflective image relay for use in an ultra-broadband half-petawatt laser system in development at the University of Rochester’s Laboratory for Laser Energetics. The design consists of four spherical mirrors in an unobscured configuration. We show the theoretical basis for such a four-mirror design using first-order optical matrix methods and nodal aberration theory. We also describe the process of aligning this design in a test bed and show the results of this alignment method. We were able to achieve a diffraction-limited nominal design. Furthermore, upon aligning the design in our test bed, we were able to successfully align the design to achieve our target wavefront error of less than 0.3 waves p–v and 0.07 waves rms at the central laser-operating wavelength of 910 nm.

47 OTHER INSTRUMENTATION↗