Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human dynamics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

How Well Does the Latest Anthropomorphic Test Device Mimic Human Impact Responses?

One of the goals of the NASA Occupant Protection Group is to understand the human tolerance to dynamic loading. This knowledge has to come through indirect approaches such as existing human response databases, anthropometric test devices (ATD), animal testing, post‐mortem human subjects, and models. This study investigated the biofidelity of the National Highway Traffic Safety Administration's ATD named the THOR (test device for human occupant restraint). If THOR responds comparably to humans, then it could potentially be used as a human surrogate to help validate space vehicle requirements for occupant protection. The THOR responses to frontal and spinal impacts (ranging from 8 to 12 G with rise times of 40, 70, and 100 ms) were measured and compared to human volunteer responses (95 trials in frontal and 58 in spinal) previously collected by the U. S. Air Force on the same horizontal impact accelerator. The impact acceleration profiles tested are within the expected range of multi‐purpose crew vehicle (MPCV) landing dynamics. A correlation score was calculated for each THOR to human comparison using CORA (CORrelation and Analysis) software. A two‐parameter beta distribution model fit was obtained for each dependent variable using maximum likelihood estimation. For frontal impacts, the THOR head x‐acceleration peak response correlated with the human response at 8 and 10‐G 100 ms but not 10‐G 70 ms. The phase lagged the human response. Head z‐acceleration was not correlated. Chest x‐acceleration was in phase, had a higher peak response, and was well correlated with lighter subjects (Cora = 0.8 for 46 kg vs. Cora = 0.4 for 126 kg). Head x‐displacement had a leading phase. Several subjects responded with the same peak displacement but the mean of the group was lower. The shoulder x‐displacement was in phase but had higher peaks than the human response. For spinal impacts, the THOR head x‐acceleration was not well correlated. Head and chest z‐acceleration was in phase but had a higher peak response. Chest z‐acceleration was highly correlated with heavier subjects at lower G pulses (Cora = 0.86 for 125 kg at 8 G). The human response was variable in shoulder z‐displacement but the THOR was in phase and was comparable to the mean peak response. Head xand z‐displacement was in phase but had higher peaks. Seat pan forces were well correlated, were in phase, but had a larger peak response than most subjects. The THOR does not respond to frontal and spinal impacts exactly the same way that a human does. Some responses are well matched and others are not. Understanding the strengths and weaknesses of this ATD is an important first step in determining its usefulness in occupant protection at NASA

Newby, N.↗

How Well Does the Latest Anthropomorphic Test Device Mimic Human Impact Responses?

One of the goals of the NASA Occupant Protection Group is to understand the human tolerance to dynamic loading. This knowledge has to come through indirect approaches such as existing human response databases, anthropometric test devices (ATD), animal testing, post-­‐mortem human subjects, and models. This study investigated the biofidelity of the National Highway Traffic Safety Administration's ATD named the THOR (test device for human occupant restraint). If THOR responds comparably to humans, then it could potentially be used as a human surrogate to help validate space vehicle requirements for occupant protection. The THOR responses to frontal and spinal impacts (ranging from 8 to 12 G with rise times of 40, 70, and 100 ms) were measured and compared to human volunteer responses (95 trials in frontal and 58 in spinal) previously collected by the U. S. Air Force on the same horizontal impact accelerator. The impact acceleration profiles tested are within the expected range of multi-­‐purpose crew vehicle (MPCV) landing dynamics. A correlation score was calculated for each THOR to human comparison using CORA (CORrelation and Analysis) software. A two-­‐parameter beta distribution model fit was obtained for each dependent variable using maximum likelihood estimation. For frontal impacts, the THOR head x-­‐acceleration peak response correlated with the human response at 8 and 10-­‐G 100 ms but not 10-­‐G 70 ms. The phase lagged the human response. Head z-­‐acceleration was not correlated. Chest x-­‐acceleration was in phase, had a higher peak response, and was well correlated with lighter subjects (Cora = 0.8 for 46 kg vs. Cora = 0.4 for 126 kg). Head x-­‐displacement had a leading phase. Several subjects responded with the same peak displacement but the mean of the group was lower. The shoulder x-­‐displacement was in phase but had higher peaks than the human response. For spinal impacts, the THOR head x-­‐acceleration was not well correlated. Head and chest z-­‐acceleration was in phase but had a higher peak response. Chest z-­‐acceleration was highly correlated with heavier subjects at lower G pulses (Cora = 0.86 for 125 kg at 8 G). The human response was variable in shoulder z-­‐displacement but the THOR was in phase and was comparable to the mean peak response. Head x-­‐ and z-­‐displacement was in phase but had higher peaks. Seat pan forces were well correlated, were in phase, but had a larger peak response than most subjects. The THOR does not respond to frontal and spinal impacts exactly the same way that a human does. Some responses are well matched and others are not. Understanding the strengths and weaknesses of this ATD is an important first step in determining its usefulness in occupant protection at NASA

Newby, Nate↗

Acquisition and production of skilled behavior in dynamic decision-making tasks

Ongoing research investigating perceptual and contextual influences on skilled human performance in dynamic decision making environments is discussed. The research is motivated by two general classes of findings in recent decision making research. First, many studies suggest that the concrete context in which a task is presented has strong influences on the psychological processes used to perform the task and on subsequent performance. Second, studies of skilled behavior in a wide variety of task environments typically implicate the perceptual system as an important contributor to decision-making performance, either in its role as a mediator between the current decision context and stored knowledge, or as a mechanism capable of directly initiating activity through the development of a 'trained eye.' Both contextual and perceptual influences place limits on the ability of traditional utility-theoretic accounts of decision-making to guide display design, as variance in behavior due to contextual factors or the development of a perceptual skill is left unexplained. The author outlines a framework in which to view questions of perceptual and contextual influences on behavior and describe an experimental task and analysis technique which will be used to diagnose the possible role of perception in skilled decision making performance.

Kirlik, Alex↗

Increases in intramuscular pressure raise arterial blood pressure during dynamic exercise

This investigation was designed to determine the role of intramuscular pressure-sensitive mechanoreceptors and chemically sensitive metaboreceptors in affecting the blood pressure response to dynamic exercise in humans. Sixteen subjects performed incremental (20 W/min) cycle exercise to fatigue under four conditions: control, exercise with thigh cuff occlusion of 90 Torr (Cuff occlusion), exercise with lower body positive pressure (LBPP) of 45 Torr, and a combination of thigh cuff occlusion and LBPP (combination). Indexes of central command (heart rate, oxygen uptake, ratings of perceived exertion, and electromyographic activity), cardiac output, stroke volume, and total peripheral resistance were not significantly different between the four conditions. Mechanical stimulation during LBPP and combination conditions resulted in significant elevations in intramuscular pressure and mean arterial pressure from control at rest and throughout the incremental exercise protocol (P < 0.05). Conversely, there existed no significant changes in mean arterial pressure when the metaboreflex was stimulated by cuff occlusion. These findings suggest that under normal conditions the mechanoreflex is tonically active and is the primary mediator of exercise pressor reflex-induced alterations in arterial blood pressure during submaximal dynamic exercise in humans.

Non-NASA Center↗

Human-in-the-Loop Evaluation of Dynamic Multi-Flight Common Route Advisories

Flights often experience large delays when they are routed around weather. Multi-flight common route advisories provide delay recovery by suggesting time-saving re-routes for groups of flights whose current weather-avoidance routes have become outdated because the weather has dissipated and/or moved away. A laboratory evaluation of these advisories was conducted by four subject matter experts having extensive experience in traffic flow management operations. These experts provided a total of 120 data points in the airspace of Houston Center. The multi-flight common route tool provides time-saving route change advisories taking into account flight plans, wind fields, and the spatio-temporal evolution of predicted convective weather. It is not designed to account for complex operational factors such as non-standard sector traversal and interactions with local traffic management initiatives; hence a relatively low percentage (37%) of advisories generated by the tool were rated as acceptable. However, a high percentage (81%) of advisories were rated as acceptable after the subject matter experts used the tool's user interface to make route modifications that accounted for relevant operational factors not considered by the tool. The workload associated with using the tool, as measured by the NASA Task Load Index, was quite low (1.1 on a scale of 0 to 10). The results of this evaluation make a good case for human-automation teaming to design operationally valid weather re-routes for delay recovery.

Traffic Flow Management↗

Human-in-the-Loop Evaluation of Dynamic Multi-Flight Common Route Advisories

Flights often experience large delays when they are routed around weather. Multi-flight common route advisories provide delay recovery by suggesting time-saving re-routes for groups of flights whose current weather-avoidance routes have become outdated because the weather has dissipated and/or moved away. A laboratory evaluation of these advisories was conducted by four subject matter experts having extensive experience in traffic flow management operations. These experts provided a total of 120 data points in the airspace of Houston Center. The multi-flight common route tool provides time-saving route change advisories taking into account flight plans, wind fields, and the spatio-temporal evolution of predicted convective weather. It is not designed to account for complex operational factors such as non-standard sector traversal and interactions with local traffic management initiatives; hence a relatively low percentage (37%) of advisories generated by the tool were rated as acceptable. However, a high percentage (81%) of advisories were rated as acceptable after the subject matter experts used the tool's user interface to make route modifications that accounted for relevant operational factors not considered by the tool. The workload associated with using the tool, as measured by the NASA Task Load Index, was quite low (1.1 on a scale of 0 to 10). The results of this evaluation make a good case for human-automation teaming to design operationally valid weather re-routes for delay recovery.

Traffic Flow Management↗

Pilot interaction with automated airborne decision making systems

The use of advanced software engineering methods (e.g., from artificial intelligence) to aid aircraft crews in procedure selection and execution is investigated. Human problem solving in dynamic environments as effected by the human's level of knowledge of system operations is examined. Progress on the development of full scale simulation facilities is also discussed.

Rouse, W. B.↗

Multibody Based Digital Astronaut Dynamics Simulation

BACKGROUND: This study provides the Software, Robotics, & Simulation Division at the NASA Johnson Space Center with a verification tool for multibody dynamics simulation requiring human motion. The motivation stems from current studies of several Vibration Isolation & Stabilization(VIS)system designs that attenuate the moments and forces which would be transmitted to a spacecraft during an exercise. A multibody dynamics model for a proposed VIS was available previously[1], therefore modeling of the VIS was not needed for this work. The interest here is in creating the multibody dynamics model of an astronaut in motion which may be utilized independently or while attached to a mechanism. An existing simulation [2] that utilizes OpenSim [3,4] and an in-house multibody dynamics package (MBDyn) [5] is used in order to verify the astronaut model. The main advantage this model will have over the existing simulation is that everything will be processed in one tool. METHODS AND RESULTS: Creating the simulation required; estimation of Body Segment Inertial Parameters (BSIP),a multibody model of the human-VIS system, joint acceleration profiles, and input files for MBDyn, which is used for this analysis. The scaling factors provided by Dumas et al. [6] are utilized in estimating the BSIP. Anthropometric data are used for estimating these parameters, the Anthropometric Survey of US Army Personnel (ANSUR II) [7] was the source. The astronaut model consists of 15 bodies, 14 joints and 32 degrees of freedom, with the dynamics topology generated using the center of mass locations and anthropometric data. MBDyn has an option for prescribed joint motion (PJM), which requires joint acceleration data as input. The joint angle data is first obtained from a motion capture system and then processed through code that has been created to generate approximate joint acceleration profiles. The topology tree for the astronaut model begins at the right foot up to the pelvis where there is one branch for going down the left leg and another for the torso. The torso branch leads to branches for the arms and a leaf body for the head/neck segment. For attachment to the VIS, the heel of the right foot is connected to the VIS platform through a fixed joint, resembling a foot restraint. The left foot does not attach to the platform in order to prevent a system with a closed loop. Topology and symmetry of the astronaut model were verified through kinematic analysis. Further verification of the forces and moments transmitted to the VIS were verified against the existing simulation. There was a satisfactory level of agreement when testing a simple motion, for example, rocking back and forth. Full exercise motions are to be tested soon. The main outcome has been a novel application of MBDyn for biomechanics modeling that is now available for dynamic simulations involving human motion. The estimation of BSIP was another useful result of this study, requiring only 15 inputs for generating mass properties of a theoretical astronaut model. Expansion on this work is possible by going through an alternative route in obtaining the joint motion data. Instead of high-tech and often expensive motion capture systems, an individual may watch videos with high focus and at a slow motion for each individual segment in order to determine the initial and final time and angle for that specific degree of freedom. Synthetic trajectories may also be created if there is no video reference available.

F N Matari↗

Assessing the Risk of Crew Injury Due to Dynamic Loads During Spaceflight

Spaceflight requires tremendous amounts of energy to achieve Earth orbit and to attain escape velocity for interplanetary missions. Although the majority of the energy is managed in such a way as to limit the accelerations on the crew, several mission phases may result in crew exposure to dynamic loads. In the automotive industry, risk of serious injury can be tolerated because the probability of a crash is remote each time a person enters a vehicle, resulting in a low total risk of injury. For spaceflight, the level of acceptable injury risk must be lower to achieve a low total risk of injury because the dynamic loads are expected on each flight. To mitigate the risk of injury due to dynamic loads, the NASA Human Research Program has developed a research plan to inform the knowledge gaps and develop relevant tools for assessing injury risk. The risk of injury due to dynamic loads can be further subdivided into extrinsic and intrinsic risk factors. Extrinsic risk factors include the vehicle dynamic profile, seat and restraint design, and spacesuit design. Human tolerance to loads varies considerably depending on the direction, amplitude, and rise-time of acceleration therefore the orientation of the body to the dynamic vector is critical to determining crew risk of injury. Although a particular vehicle dynamic profile may be safe for a particular design, the seat, restraint, and suit designs can affect the risk of injury due to localized effects. In addition, characteristics intrinsic to the crewmember may also contribute to the risk of injury, such as crewmember sex, age, anthropometry, and deconditioning due to spaceflight, and each astronaut may have a different risk profile because of these factors. The purpose of the research plan is to address any knowledge gaps in the risk factors to mitigate injury risk. Methods for assessing injury risk have been well documented in other analogous industries and include human volunteer testing, human exposure to dynamic environments, post-mortem human subject (PMHS) testing, animal testing, anthropomorphic test devices (ATD), dynamic models of the human, numerical models of ATDs, and numerical models of the human. Each has inherent strengths and limitations. For example, human volunteer testing is advantageous because a population can be selected that is similar to the astronaut corps; however, because of the inherent ethical limitations, only sub-injurious conditions can be tested. PMHSs can be tested in a variety of conditions including injurious levels, but the responses are not completely analogous to living human subjects. In addition, it is exceedingly difficult to select a PMHS population that is similar to the astronaut corps. ATDs are currently widely used in the automotive industry and military because they are highly repeatable and durable. Unfortunately, because they are mechanical models of the human body, the biofidelity of the responses are limited to dynamic conditions used to validate the ATD. Numerical models of the ATD, in addition to the strengths and limitations for ATDs, are easy to use for a variety of designs before a design is fabricated, but also have additional limitations for ATDs, are easy to use for a variety of designs before a design is fabricated, but also have additional uncertainty. Dynamic models are simple and easy to use, but do not account for localized effects of the seat and suit. Finally, numerical models of the human have the potential to have the most advantages; however, the current models are not validated for the conditions expected during spaceflight. To properly assess spaceflight conditions with numerical human models, human data would be needed to optimize the model responses for those conditions. Using the appropriate assessment method with the knowledge gained for each risk factor, an appropriate approach for mitigating the risk of injury due to dynamic loads can be developed ensuring crew safety in future NASA vehicles.

Somers, J. T.↗

Dynamics of A Vibration Isolation System Including Inertia of the Human Body

Using an exercise device in a spacecraft is liable to transmit an unacceptable amount of vibration to that vehicle. This is commonly mitigated by a Vibration Isolation System (VIS), whose dynamics must be analyzed to confirm that the oscillatory forces on the spacecraft remain within allowed range, both from a structural and microgravity perspective (see, e.g., [1]). When modeling a VIS for countermeasures devices, one common approach is to record forces and moments applied on the floor while exercising, and then drive the VIS simulation by applying these recorded loads to the exercise platform part of the VIS mechanical model. This approach misses the fact that when exercising on a moving platform, the force and moment on it will differ from that on the stationary floor due to inertial effects involving the human body. For example, standing up on a platform as it gives under the subject’s feet reduces the foot force on it, and such inertial effects are especially complex for rotational motion. In principle, one could model both the motion of the human body and dynamics of the VIS mechanism in a single combined simulation, e.g., employing a tool such as the commonly used biomechanical simulation OpenSim. Here, the joints of the human body would be driven kinematically along prescribed exercise trajectories while the dynamics engine computed the response of the VIS degrees of freedom. However, mechanism designers and biomechanics experts have their own established tools, making it very desirable to have a way of decoupling the biomechanics from the VIS modeling, simulation, and analyses. We have derived a set of equations that rigorously accomplishes this goal, and have implemented them as an interface function that provides an alternative driving mechanism for an existing force-based VIS analysis simulation. When enabled, the simulated human/VIS system dynamics is now driven by this function, instead of the recorded force methodology described above. The function is designed to accept input from a data file containing the required time-stamped human motion and inertia terms corresponding to the specific exercise in question. This data file is generated by an OpenSim plugin written for that purpose. The existing VIS analytical simulation is developed using NASA’s Trick Simulation Environment [2], as well as its MBDyn multibody dynamics [3] package. The presentation will provide a detailed overview of the mathematical formulation, assumptions, plugin implementation, software interfaces, and results for a sample set of representative exercises. The results from this work aim to better inform VIS design efforts, as well as countermeasure device/protocol designs with respect to exercise type and frequency effects on vehicle structural and microgravity restrictions.

Countermeasures↗

The dynamic contributions of the otolith organs to human ocular torsion

We measured human ocular torsion (OT) monocularly (using video) and binocularly (using search coils) while sinusoidally accelerating (0.7 g) five human subjects along an earth-horizontal axis at five frequencies (0.35, 0.4, 0.5, 0.75, and 1.0 Hz). The compensatory nature of OT was investigated by changing the relative orientation of the dynamic (linear acceleration) and static (gravitational) cues. Four subject orientations were investigated: (1) Y-upright-acceleration along the interaural (y) axis while upright; (2) Y-supine-acceleration along the y-axis while supine; (3) Z-RED-acceleration along the dorsoventral (z) axis with right ear down; (4) Z-supine-acceleration along the z-axis while supine. Linear acceleration in the Y-upright, Y-supine and Z-RED orientations elicited conjugate OT. The smaller response in the Z-supine orientation appeared disconjugate. The amplitude of the response decreased and the phase lag increased with increasing frequency for each orientation. This frequency dependence does not match the frequency response of the regular or irregular afferent otolith neurons; therefore the response dynamics cannot be explained by simple peripheral mechanisms. The Y-upright responses were larger than the Y-supine responses (P < 0.05). This difference indicates that OT must be more complicated than a simple low-pass filtered response to interaural shear force, since the dynamic shear force along the interaural axis was identical in these two orientations. The Y-supine responses were, in turn, larger than the Z-RED responses (P < 0.01). Interestingly, the vector sum of the Y-supine responses plus Z-RED responses was not significantly different (P = 0.99) from the Y-upright responses. This suggests that, in this frequency range, the conjugate OT response during Y-upright stimulation might be composed of two components: (1) a response to shear force along the y-axis (as in Y-supine stimulation), and (2) a response to roll tilt of gravitoinertial force (as in Z-RED stimulation).

NASA Discipline Neuroscience↗

Wetware, Hardware, or Software Incapacitation: Observational Methods to Determine When Autonomy Should Assume Control

Control-theoretic modeling of human operator's dynamic behavior in manual control tasks has a long, rich history. There has been significant work on techniques used to identify the pilot model of a given structure. This research attempts to go beyond pilot identification based on experimental data to develop a predictor of pilot behavior. Two methods for pre-dicting pilot stick input during changing aircraft dynamics and deducing changes in pilot behavior are presented This approach may also have the capability to detect a change in a subject due to workload, engagement, etc., or the effects of changes in vehicle dynamics on the pilot. With this ability to detect changes in piloting behavior, the possibility now exists to mediate human adverse behaviors, hardware failures, and software anomalies with autono-my that may ameliorate these undesirable effects. However, appropriate timing of when au-tonomy should assume control is dependent on criticality of actions to safety, sensitivity of methods to accurately detect these adverse changes, and effects of changes in levels of auto-mation of the system as a whole.

Trujillo, Anna C.↗

Dynamic Modeling of Process Technologies for Closed-Loop Water Recovery Systems

Detailed chemical process simulations are a useful tool in designing and optimizing complex systems and architectures for human life support. Dynamic and steady-state models of these systems help contrast the interactions of various operating parameters and hardware designs, which become extremely useful in trade-study analyses. NASA s Exploration Life Support technology development project recently made use of such models to compliment a series of tests on different waste water distillation systems. This paper presents dynamic simulations of chemical process for primary processor technologies including: the Cascade Distillation System (CDS), the Vapor Compression Distillation (VCD) system, the Wiped-Film Rotating Disk (WFRD), and post-distillation water polishing processes such as the Volatiles Removal Assembly (VRA) that were developed using the Aspen Custom Modeler and Aspen Plus process simulation tools. The results expand upon previous work for water recovery technology models and emphasize dynamic process modeling and results. The paper discusses system design, modeling details, and model results for each technology and presents some comparisons between the model results and available test data. Following these initial comparisons, some general conclusions and forward work are discussed.

Allada, Rama Kumar↗

Dynamic Modeling of Process Technologies for Closed-Loop Water Recovery Systems

Detailed chemical process simulations are a useful tool in designing and optimizing complex systems and architectures for human life support. Dynamic and steady-state models of these systems help contrast the interactions of various operating parameters and hardware designs, which become extremely useful in trade-study analyses. NASA s Exploration Life Support technology development project recently made use of such models to compliment a series of tests on different waste water distillation systems. This paper presents dynamic simulations of chemical process for primary processor technologies including: the Cascade Distillation System (CDS), the Vapor Compression Distillation (VCD) system, the Wiped-Film Rotating Disk (WFRD), and post-distillation water polishing processes such as the Volatiles Removal Assembly (VRA). These dynamic models were developed using the Aspen Custom Modeler (Registered TradeMark) and Aspen Plus(Registered TradeMark) process simulation tools. The results expand upon previous work for water recovery technology models and emphasize dynamic process modeling and results. The paper discusses system design, modeling details, and model results for each technology and presents some comparisons between the model results and available test data. Following these initial comparisons, some general conclusions and forward work are discussed.

Allada, Rama Kumar↗

The investigation of vertebral injury sustained during aircrew ejection

A series of tests were performed on excised human vertebral segments to determine the static and dynamic response of the thoraco-lumbar spine when loaded in flexion. A total of fifteen tests were performed on eleven specimens. Specimens were obtained from male donors ranging in age from 34 to 60 years. Demographic data pertinent to each specimen and the elapsed time between death of the donor and testing of each corresponding specimen are presented. Only spinal segments comprised of lower thoracic and upper lumbar vertebrae were tested because in aircraft ejection injuries clinical complications in this anatomical region predominate. A complex continuum mathematical model describing the dynamic response of the human spine was formulated, solved, and verified experimentally. Detailed results are presented in figures, tables, and equations.

Benedict, J. V.↗

Adjusting a Full Body Model to Mitigate Inverse Kinematics Artifacts in Opensim

BACKGROUND: In support of Vibration Isolation and Stabilization (VIS) system development for Human Health Countermeasures (HHC) exercise systems in space, such as the European Enhanced Exploration Exercise Device (E4D) [1], dynamic quantities required to model the response of a proposed VIS while considering the effect of VIS motion on the forces between the human and VIS platform were obtained using motion capture data [2]. On occasion, large-amplitude oscillatory spikes were found in the subject’s linear and angular momentum derivatives, affecting analyses that depend on forces and moments derived from motion capture. The purpose of this investigation was to identify causes of these artifacts and techniques for their resolution. METHODS AND RESULTS: To obtain the required human dynamic quantities to drive the VIS simulation, motion capture data was collected containing recorded trajectories of passive retroreflective markers on body landmarks of an exercising subject. Since the full body Rajagopal model [3] was originally used to enhance gait analysis, upper body joints did not require large Ranges of Motion (ROM). We thus modified the Rajagopal model [4, 5] to allow it to be used for upper body intensive exercises like those common to the E4D. OpenSim Inverse Kinematics (IK) [6] was performed using these scaled subject models to generate the joint angles throughout the exercise while minimizing marker error. At times, the arms were observed to ‘snap’ from one configuration to another, causing spike artifacts. Following IK, a custom OpenSim plugin [7] was used to determine the required dynamic quantities including the rates of change of the linear and angular momenta of the human. Since motion capture is recorded at a larger time step than required by the VIS simulation, the human center of mass location was fit with splines and a second derivative taken to obtain the momentum derivative, allowing the VIS simulation to maintain conservation of momentum when appropriate. In a few cases during this stage, artifacts much larger than the expected noise of the second derivatives were introduced. Investigation of cases containing artifacts revealed several modifications that could be made to the OpenSim model to improve IK results. Since OpenSim models use Euler angles and rotation sequences, ‘gimbal lock’ would be encountered in the arms when raised 90 degrees to the side (e.g., T-pose, some hang clean exercise, etc.). This was resolved by reorienting the horizontal axes at the shoulder joint by 45 degrees, placing ‘gimbal lock’ outside common arm ROM, with the arm ROMs adjusted following this change. Elbow and wrist ROMs could also be adjusted to allow realistic motion while at the same time limiting the likelihood of unrealistic orientations. On occasion, the arms flipped backwards when raised above the head. This was prevented by using medial elbow markers in scaling and IK. When medial markers were not available, the acromial joint location in the unscaled model was shifted before model scaling to better align the arm with available markers. Lastly, artifacts which became apparent after taking the second derivatives of spline-fit data were found to occur in cases when the pelvis rotation limit prevented the full range of motion of an exercise. These issues were resolved by unclamping the pelvis rotation limit. Through this investigation, an understanding of conditions leading to IK artifacts was acquired allowing the automation of artifact detection. These artifact detection and mitigation techniques can be applied toward modeling of upper body motions in aerospace and other fields for improved IK results.

C A Bell↗

Nonlinear and Digital Man-machine Control Systems Modeling

An adaptive modeling technique is examined by which controllers can be synthesized to provide corrective dynamics to a human operator's mathematical model in closed loop control systems. The technique utilizes a class of Liapunov functions formulated for this purpose, Liapunov's stability criterion and a model-reference system configuration. The Liapunov function is formulated to posses variable characteristics to take into consideration the identification dynamics. The time derivative of the Liapunov function generate the identification and control laws for the mathematical model system. These laws permit the realization of a controller which updates the human operator's mathematical model parameters so that model and human operator produce the same response when subjected to the same stimulus. A very useful feature is the development of a digital computer program which is easily implemented and modified concurrent with experimentation. The program permits the modeling process to interact with the experimentation process in a mutually beneficial way.

Mekel, R.↗