Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “highly insulating windows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

176 records · Page 10

Building America Case Study: Impact of Slab-Foundation Heat Transfer on Space-Conditioning Energy Use in Florida, Cocoa, Florida

Heat transfer to slab foundations has remained an area of building science with poor understanding over the last three decades of energy efficiency research. This is somewhat surprising since the area of floors in single family homes is generally equal to wall, or windows or attics which have been extensively evaluated. Research that has been done has focused in the impact of slab on grade foundations and insulation schemes on heat losses associated with heating in predominantly heating dominated climates. Slab on grade construction is very popular in cooling-dominated southern states where it accounts for 77 percent of new home floors according to U.S. Census data in 2014. There is a widespread conception that tile flooring, as opposed to carpet, makes for a cooler home interior in warm climates. Empirical research is needed as building energy simulations such as DOE-2 and EnergyPlus rely on simplified models to evaluate these influences. BA-PIRC performed experiments over an entire year from 2014-2015 in FSEC's Flexible Residential Test Facilities (FRTF) intended to assess for the first time 1) slab on grade influence in a cooling dominated climate, and 2) how the difference in a carpeted vs. uncarpeted building might influence heating and cooling. Two identical side by side residential buildings were evaluated, the East with pad and carpet and the west with a bare slab floor. A highly detailed grid of temperature measurements were taken on the slab surface at various locations as well as at depths of 1, 2.5, 5, 10 and 20 feet.

BAPIRC↗

A Compact and High Performance Muon Capture Channel for Muon Accelerators

It is widely believed that a neutrino factory would deliver unparallel performance in studying neutrino mixing and would provide tremendous sensitivity to new physics in the neutrino sector. Here we will describe and simulate the front-end of the neutrino factory system, which plays critical role in determining the number of muons that can be accepted by the downstream accelerators. In this system, a proton bunch on a target creates secondaries that drift into a capture transport channel. A sequence of rf cavities forms the resulting muon beams into strings of bunches of differing energies, aligns the bunches to nearly equal central energies, and initiates ionization cooling. For this, the muon beams are transported through sections containing high-gradient cavities and strong focusing solenoids. In this paper we present results of optimization and variation studies toward obtaining the maximum number of muons for a neutrino factory by using a compact transport channel. It has been suggested computationally and experimentally that the maximum achievable gradient is enhanced by introducing an external magnetic field at right angles to the rf electric field since it suppresses field-emission processes. Here, we have discussed a possible scheme for extending the concept of magnetic insulation to capture, transport, and cool muons in a neutrino factory. We incorporated this idea into a new lattice design where the rf cavities are shaped so that their walls were tangential to the magnetic-field lines. We showed that, with magnetic insulation, the field-emitted electrons impact the cavity surface with energies four orders-of-magnitude less than in conventional pillbox cavities; consequently, damage from field-emission is suppressed significantly. While demanding in terms of power requirements, this neutrino factory lattice showed satisfactory performance in both cooling and collecting the accepted muons within the requirements for the IDSNF. Optimizations were also made to reduce heating on the absorber windows minimizing losses in the accepted muon fluxes. The next step for verifying these ideas should be an experimental demonstration of a single muon accelerator magnetically-insulated rf cavity. A successful demonstration will provide us with a new versatile tool for a future muon accelerator.

43 PARTICLE ACCELERATORS↗

Three-Stage InP Submillimeter-Wave MMIC Amplifier

A submillimeter-wave monolithic integrated- circuit (S-MMIC) amplifier has been designed and fabricated using an indium phosphide (InP) 35-nm gate-length high electron mobility transistor (HEMT) device, developed at Northrop Grumman Corporation. The HEMT device employs two fingers each 15 micrometers wide. The HEMT wafers are grown by molecular beam epitaxy (MBE) and make use of a pseudomorphic In0.75Ga0.25As channel, a silicon delta-doping layer as the electron supply, an In0.52Al0.48As buffer layer, and an InP substrate. The three-stage design uses coplanar waveguide topology with a very narrow ground-to-ground spacing of 14 micrometers. Quarter-wave matching transmission lines, on-chip metal-insulator-metal shunt capacitors, series thin-film resistors, and matching stubs were used in the design. Series resistors in the shunt branch arm provide the basic circuit stabilization. The S-MMIC amplifier was measured for S-parameters and found to be centered at 320 GHz with 13-15-dB gain from 300-345 GHz. This chip was developed as part of the DARPA Submillimeter Wave Imaging Focal Plane Technology (SWIFT) program (see figure). Submillimeter-wave amplifiers could enable more sensitive receivers for earth science, planetary remote sensing, and astrophysics telescopes, particularly in radio astronomy, both from the ground and in space. A small atmospheric window at 340 GHz exists and could enable ground-based observations. However, the submillimeter-wave regime (above 300 GHz) is best used for space telescopes as Earth s atmosphere attenuates most of the signal through water and oxygen absorption. Future radio telescopes could make use of S-MMIC amplifiers for wideband, low noise, instantaneous frequency coverage, particularly in the case of heterodyne array receivers.

Pukala, David↗

Do Flashing and Sealant Materials Need to be Exposed to Extreme Cycling?

In the U.S., over 50% of homes were built before 1980, when minimal building codes existed. The aging of building envelopes can significantly contribute to the air leakage, moisture intrusion, and durability of buildings leading to higher energy demands. Although the durability of building materials and envelope systems has been studied extensively, the durability of specific components like window-wall flashing and sealants remains underexplored. Current standards such as ASTM, NIST, and AAMA primarily focus on durability testing considering the high temperatures only and require sealant testing on anodized aluminum panels, leaving questions about performance in cold or fluctuating temperatures unanswered. Current ASTM and AAMA standards provide guidelines for durability testing but predominantly focus on exposure to higher temperature conditions. It remains unclear how exposure to cold temperatures, or cycles of both hot and cold conditions, affect the durability of these materials. Furthermore, AAMA standards mandate that flashing materials be tested on anodized aluminum panels, which may not reflect real-world applications. Therefore, this initial study aims to explore this concern through testing by constructing two window-wall interface prototypes and applying five different flashing and sealant materials to their joints. These samples were subjected to extreme temperatures, ranging from −34 ℃ (−30 °F) to 50 ℃ (122 °F), over a 28-day period (fourteen cycles of 24 hours), with daily visual inspections to document any signs of deterioration such as wrinkling, distortion, or warping. The study has two main objectives: (1) to determine whether flashing and sealant materials lose their durability and strength when exposed to varying climate conditions, specifically cold climates, and (2) to assess whether the interaction of these materials with different substrates (e.g., lumber, PVC, insulation) affects their durability and strength under varying climate conditions. The findings demonstrate how aging impacts the durability of window-wall systems interfaces, justifying future research that potentially could lead to the development of new testing protocols if significant defects are identified.

Palani, Hevar [ORNL] (ORCID:0000000220211994)↗

Computational Discovery of Ultralow Thermal Conductivity in the Energy-Degenerate Polymorphic Crystal Family A 2 M 2 M’Q 4

Crystalline materials, characterized by their well-defined lattices, typically exhibit a unique global thermodynamic minimum for a specific composition. However, in this study, we discover a quaternary chalcogenide family, A 2 M 2 M’Q 4 (A: alkali metals; M: coinage metal; M’: transition or group-IVA metals; Q: chalcogens), that exhibits pervasive energy (near-)degeneracy. For a given composition, multiple structurally distinct polymorphs exist within a formation enthalpy window of only a few milli-electron volts per atom. We quantify this inherent structural flexibility using a dedicated descriptor, σ f : the standard deviation of formation enthalpies among degenerate (meta)stable polymorphs. The consistently low σf observed across the A 2 M 2 M’Q 4 family signifies a characteristically shallow and frustrated potential energy landscape, which drives pronounced lattice anharmonicity, marking these materials as prime candidates for ultralow lattice thermal conductivity (κ L ). Employing an advanced high-throughput computational framework that integrates thermodynamics, lattice dynamics, and thermal conductivity calculations, we screen 1215 A 2 M 2 M’Q 4 compounds, identifying 30 stable candidates with κ L < 0.5 W m –1 K –1 at 300 K. Among them, Rb 2 Ag 2 SnTe 4 and Rb 2 Au 2 HfTe 4 , two representatives from the IVA and TM subgroups, are predicted to show ultralow room-temperature κ L of 0.174 W m –1 K –1 and 0.295 W m –1 K –1 , respectively. A systematic analysis suggests that the nonbonding and antibonding states induced by “dual rattlers” are the origin of low thermal conductivity in these compounds. Our results position the A 2 M 2 M’Q 4 family as a rich source of intrinsic thermal insulators and suggest that polymorphic energy degeneracy may serve as a valuable signpost for identifying crystalline families with potential anharmonicity.

cations↗

Low-E Storm Windows Gain Acceptance as a Home Weatherization Measure

This article for Home Energy Magazine describes work by the U.S. Department of Energy to develop low-emissivity storm windows as an energy efficiency-retrofit option for existing homes. The article describes the low-emissivity invisible silver metal coatings on the glass, which reflect heat back into the home in winter or back outside in summer and the benefits of low-e storm windows including insulation, air sealing, noise blocking, protection of antique windows, etc. The article also describes Pacific Northwest National Laboratory's efforts on behalf of DOE to overcome market barriers to adoption of the technology, including performance validation studies in the PNNL Lab Homes, cost effectiveness analysis, production of reports, brochures, how-to guides on low-e storm window installation for the Building America Solution Center, and a video posted on YouTube. PNNL's efforts were reviewed by the Pacific Northwest Regional Technical Forum (RTF), which serves as the advisory board to the Pacific Northwest Electric Power Planning Council and Bonneville Power Administration. In late July 2015, the RTF approved the low-e storm window measure’s savings and specifications, a critical step in integrating low-e storm windows into energy-efficiency planning and utility weatherization and incentive programs. PNNL estimates that more than 90 million homes in the United States with single-pane or low-performing double-pane windows would benefit from the technology. Low-e storm windows are suitable not only for private residences but also for small commercial buildings, historic properties, and facilities that house residents, such as nursing homes, dormitories, and in-patient facilities. To further assist in the market transformation of low-e storm windows and other high-efficiency window attachments, DOE helped found the window Attachment Energy Rating Council (AERC) in 2015. AERC is an independent, public interest, non-profit organization whose mission is to rate, label, and certify the performance of window attachments.

Building Technologies Office↗

Interaction between Heat Pump Water Heaters or Other Internal Point Source Loads and a Central Heating System

Water heating represents approximately 18% of residential energy consumption, or 4.6 quadrillion Btus of source energy use annually (EIA 2009). Heat pump water heaters (HPWHs) offer an efficient option for residential water heating, with the ability to reduce water heating energy consumption by up to 63%. Previous research has demonstrated the laboratory performance of HPWHs and has shown savings of 43 to 62% on water heating energy consumption are possible, based on field tests (Ecotope 2015). In order to achieve such high efficiencies, HPWHs employ a refrigeration cycle to move heat from the ambient air into the water. Therefore, when HPWHs are installed in conditioned space, they will remove heat from that space which can help the HVAC system in the cooling season and require additional energy from the HVAC system in the heating season. This project provides an unbiased evaluation of the space conditioning interactions between a HPWH and the heating system in several locations throughout the home to further our understanding of the impact that HPWHs have on space conditioning loads. This report explores the HPWH interaction factor from several perspectives: (1) a theoretical analysis, (2) a review of previous literature, and (2) an experimental assessment. The experiments were conducted in PNNL’s side-by-side Lab Homes, which provide a platform for evaluating energy-saving and grid-responsive technologies in a controlled environment. The PNNL Lab Homes are two factory-built homes installed on PNNL’s campus in Richland, Washington. The homes represent existing homes, which account for approximately 99% of occupied homes in the U.S. These 1500 ft2 homes have three bedrooms, two bathrooms, and are equipped with 7.7 HSPF heat pump and an electric forced air furnace. Both homes have R-22 floors, R-11 walls and R-22 ceiling insulation levels, with double-pane clear glass windows. The results of this experiment verified that the energy use of the HVAC system increases as a point source cooling load, like a HPWH, is moved closer to the thermostat. The opposite is also true, as a point source heating load is moved closer to the thermostat, the heating load decreases. The results show between 30-40% difference between the interaction that this type of load has when it is placed in the master bathroom compared to the living room for the PNNL Lab Homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transparent silica aerogel slabs synthesized from nanoparticle colloidal suspensions at near ambient conditions on omniphobic liquid substrates

This paper presents a novel sol-gel method to synthesize large and thick silica aerogel monoliths at near ambient conditions using a commercial aqueous solution of colloidal silica nanoparticles as building blocks. To achieve slabs with high visible transmittance and low thermal conductivity, the method combines the strategies of (i) synthesizing gels on an omniphobic perfluorocarbon liquid substrate, (ii) aging at temperatures above room temperature, and (iii) performing solvent exchange with a low-surface-tension organic solvent prior to ambient drying. The omniphobic liquid substrates were used to prevent cracking and ensure an optically-smooth surface, while nanoparticle building blocks were small (<10 nm) to limit volumetric light scattering. Gels were aged at temperatures between 25 and 80 °C for up to 21 days to make them stronger and stiffer and to reduce shrinkage and cracking during ambient drying. Ambient drying was achieved by first exchanging water in the gel pores for octane, followed by drying in an octane-rich atmosphere to decrease capillary forces. The synthesized nanoparticle-based silica aerogel monoliths had thicknesses up to 5 mm, diameters up to 10 cm, porosities exceeding 80%, and thermal conductivities as low as 0.08 W m –1 K –1 . Notably, the slabs featured visible transmittance exceeding 75% even for slabs as thick as 5 mm. The as-synthesized aerogel monoliths were exposed to TMCS vapor to induce hydrophobic properties resulting in a water contact angle of 140° that prevented water infiltration into the pores and protected the aerogels from water damage. This simple synthesis route conducted at near ambient conditions produces hydrophobic aerogel monoliths with promising optically transparent and thermally insulating properties that can be adhered to glass panes for window insulation and solar-thermal energy conversion applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-R Walls for New Construction Structural Performance: Integrated Rim Header Testing

The Building America Program takes two prominent approaches to construct higher R-value walls: larger dimension framing and exterior rigid foam insulation. These have had some success; however, for many production builders the cost of changing framing systems is high, so the changes have been slowly realized. Also, recent building code changes have raised some performance issues for exterior sheathing and raised heel trusses, for example, that indicates a need for continued performance testing of wall systems. Furthermore, some material use survey data have shown that often when builders are switching to 2 × 6 framing members, they commonly use of 16-in. o.c. spacing. The opportunity to (1) encourage the use of thicker framing systems for much higher R-value walls; (2) construct wall systems that optimize the framing use to reduce thermal breaks; and (3) extract opportunities to reduce costs, all remain high priorities for the Building America program, the NAHB Research Center Industry Partnership, and builders. Similarly for the use of exterior rigid sheathing, builders and researchers have investigated alternative bracing techniques to eliminate the use of wood structural sheathing in lieu of foam board sheathing. Structural characteristics, especially in the direction perpendicular to the sheathing, have been reevaluated for the building codes. These include pressure equalization issues across multiple layers of the wall system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Public Housing: A Tailored Approach to Energy Retrofits - Raleigh

More than 1 million U.S. Department of Housing and Urban Development-supported public housing units provide rental housing for eligible low-income families across the country. These units range from scattered single-family houses to high-rise apartments. In this project, the Advanced Residential Integrated Energy Solutions Collaborative (ARIES) worked with two public housing authorities (PHAs) to develop packages of energy efficiency retrofit measures the PHAs can cost-effectively implement with their own staffs in the normal course of housing operations at the time when units are refurbished between occupancies. ARIES conducted a survey of PHAs to assess their receptiveness to this concept and the applicability of the concept to PHA units. The results of the survey, to which more than 100 PHAs responded, support the proposed approach. The project consisted of a field evaluation in which energy audits were performed on a sample of PHA units at two housing authorities. Energy efficiency turnover protocols were developed for typical units, the protocol was implemented by PHA staff, and the effectiveness of the protocol was quantified through field testing and modeling. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing, and measures that improve equipment efficiency. In the 10 housing units in which ARIES documented implementation, reductions in average air leakage of 16%-20% and duct leakage of 38% were obtained. Total source energy consumption savings was estimated at 6%-10% based on Building Energy Optimization modeling with a simple payback of 1.7-2.2 years. Implementation challenges were encountered, mainly related to required operational changes and budgetary constraints. Lack of complete training and inadequate quality control can prevent PHAs from effectively retrofitting units to their full potential. Nevertheless, despite these hurdles, simple improvements, such as caulking and sealing penetrations, windows, and doors; sealing duct boots; and adding pipe insulation into a standardized turnover protocol can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally. Islip Housing Authority - Single Story Typical home - Raleigh, NC Raleigh Housing Authority - 2 story typical home in Raleigh housing authority - Terrace Park

air filtration↗

Achieving Very High Efficiency and Net Zero Energy in an Existing Home in a Hot-Humid Climate: Long-Term Utility and Monitoring Data

This study summarizes the first six months of detailed data collected on a single family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data on how envelope modifications and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Originally published in February 2012, this revised version of the report contains further research conducted on the Parker residence. Key updates include one full year of additional data, an analysis of cooling performance of the mini-split heat pump, an evaluation of room-to-room temperature distribution, and an evaluation of plug-in automobile charging performance, electricity consumption, and load shape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving Very High Efficiency and Net Zero Energy in an Existing Home in a Hot-Humid Climate: Long-Term Utility and Monitoring Data (Revised)

This study summarizes the first six months of detailed data collected on a single family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data on how envelope modifications and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Originally published in February2012, this revised version of the report contains further research conducted on the Parker residence. Key updates include one full year of additional data, an analysis of cooling performance of the mini-split heat pump, an evaluation of room-to-room temperature distribution, and an evaluation of plug-in automobile charging performance, electricity consumption, and load shape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts (Fact Sheet)

The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent). The original ventilation design for the project was provided by a local engineer and consisted of a single large heat recovery ventilator (HRV) located in a mechanical room in the basement with a centralized duct system providing supply air to the main living space and exhausting stale air from the single bathroom in each apartment. This design was deemed to be far too costly to install and operate for several reasons: the large central HRV was oversized and the specified flows to each apartment were much higher than the ASHRAE 62.2 rate; an extensive system of ductwork, smoke and fire dampers, and duct chases were specified; ductwork required a significant area of dropped ceilings; and the system lacked individual ventilation control in the apartments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗