Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high performance buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Concentrator Development

During the years of technology development by the Parabolic Dish program, the problems peculiar to tracking dishes have been explored in depth with particular emphasis on economics. Starting with the Precursor Concentrator, testing techniques and apparatus such as calorimeters and the flux mapper were developed. At the same time, mirrors were developed to have a long operating life as well as high performance. Commercially available equipment was evaluated as well. Building on all these elements, the Test Bed Concentrators were designed and built. With a peak intensity in the focal plane of over 17,500 suns and an average concentrator ratio over 3000 on an eight inch diameter aperture, they have proven to be the work horses of the technology. With a readily adjustable mirror array, they have proved to be an essential tool in the development of dish components, receivers, heat transport systems, instrumentation, controls, engines, and materials - all necessary to cost effective modules and plants. Utilizing the lessons learned from this technology, most cost effective systems were designed. These included Parabolic Dish Number 1 (PDC-1) and PDC-2 currently in final design by Acurex Corporation. Even more advanced concepts are being worked on, such as the Cassegranian systems by BDM Corporation.

Owen, W. A.↗

Individual differences in airline captains' personalities, communication strategies, and crew performance

Aircrew effectiveness in coping with emergencies has been linked to captain's personality profile. The present study analyzed cockpit communication during simulated flight to examine the relation between captains' discourse strategies, personality profiles, and crew performance. Positive Instrumental/Expressive captains and Instrumental-Negative captains used very similar communication strategies and their crews made few errors. Their talk was distinguished by high levels of planning and strategizing, gathering information, predicting/alerting, and explaining, especially during the emergency flight phase. Negative-Expressive captains talked less overall, and engaged in little problem solving talk, even during emergencies. Their crews made many errors. Findings support the theory that high crew performance results when captains use language to build shared mental models for problem situations.

Orasanu, Judith↗

NEMA wire and cable standards development programs

The National Electrical Manufacturers Association (NEMA) is the nation's largest trade association for manufacturers of electrical equipment. Its member companies produce components, end-use equipment and systems for the generation, transmission, distribution, control and use of electricity. The wire and cable division is presented in 6 sections: building wire and cable, fabricated conductors, flexible cords, high performance wire and cable, magnet wire, and power and control cable. Participating companies are listed.

Baird, Robert W.↗

Precipitation Estimates for Hydroelectricity

Hydroelectric plants require precise and timely estimates of rain, snow and other hydrometeors for operations. However, it is far from being a trivial task to measure and predict precipitation. This paper presents the linkages between precipitation science and hydroelectricity, and in doing so it provides insight into current research directions that are relevant for this renewable energy. Methods described include radars, disdrometers, satellites and numerical models. Two recent advances that have the potential of being highly beneficial for hydropower operations are featured: the Global Precipitation Measuring (GPM) mission, which represents an important leap forward in precipitation observations from space, and high performance computing (HPC) and grid technology, that allows building ensembles of numerical weather and climate models.

Tapiador, Francisco J.↗

High-Throughput, Adaptive FFT Architecture for FPGA-Based Spaceborne Data Processors

Exponential growth in microelectronics technology such as field-programmable gate arrays (FPGAs) has enabled high-performance spaceborne instruments with increasing onboard data processing capabilities. As a commonly used digital signal processing (DSP) building block, fast Fourier transform (FFT) has been of great interest in onboard data processing applications, which needs to strike a reasonable balance between high-performance (throughput, block size, etc.) and low resource usage (power, silicon footprint, etc.). It is also desirable to be designed so that a single design can be reused and adapted into instruments with different requirements. The Multi-Pass Wide Kernel FFT (MPWK-FFT) architecture was developed, in which the high-throughput benefits of the parallel FFT structure and the low resource usage of Singleton s single butterfly method is exploited. The result is a wide-kernel, multipass, adaptive FFT architecture. The 32K-point MPWK-FFT architecture includes 32 radix-2 butterflies, 64 FIFOs to store the real inputs, 64 FIFOs to store the imaginary inputs, complex twiddle factor storage, and FIFO logic to route the outputs to the correct FIFO. The inputs are stored in sequential fashion into the FIFOs, and the outputs of each butterfly are sequentially written first into the even FIFO, then the odd FIFO. Because of the order of the outputs written into the FIFOs, the depth of the even FIFOs, which are 768 each, are 1.5 times larger than the odd FIFOs, which are 512 each. The total memory needed for data storage, assuming that each sample is 36 bits, is 2.95 Mbits. The twiddle factors are stored in internal ROM inside the FPGA for fast access time. The total memory size to store the twiddle factors is 589.9Kbits. This FFT structure combines the benefits of high throughput from the parallel FFT kernels and low resource usage from the multi-pass FFT kernels with desired adaptability. Space instrument missions that need onboard FFT capabilities such as the proposed DESDynl, SWOT (Surface Water Ocean Topography), and Europa sounding radar missions would greatly benefit from this technology with significant reductions in non-recurring cost and risk.

NguyenKobayashi, Kayla↗

Automated Air Sealing Demonstration: Denver Federal Center Building 40

This project aimed to demonstrate building airtightness achieved by automated air sealing in a commercial building setting. The automated air sealing demonstrated in this project uses a modified blower door to pressurize and distribute the sealing aerosol to achieve the required building airtightness. To demonstrate this technology, Building 40 at the Denver Federal Center, a federally owned campus under the jurisdiction, custody and control of the U.S. General Services Administration (GSA), was selected for testing (Figure 2). This building is currently undergoing several retrofit projects, including increasing insulation, installing high-performance windows, and adding advanced equipment, control systems, and automated air sealing. This demonstration project involved installing automated air sealing and measuring the improvements in the building's airtightness. The automated air sealing was installed over two days by AeroBarrier, the vendor. An external blower door test contractor measured the airtightness of the demonstration space before and after air sealing. The new airtightness value and the percentage increase in airtightness were used to evaluate the energy savings potential of automated air sealing. These airtightness values were used to compute the energy savings and CO 2 emissions reduction for different climate zones, building types, and initial airtightness conditions. In addition, the heating, ventilation and air conditioning (HVAC) load reduction attributable to the reduced building air leakage was studied. This study included research to determine the cost and time reduction of automated air sealing. Finally, the automated air sealing performance was evaluated qualitatively using a focus group discussion that included GSA and Bristol, the general contractor. The installation has shown the demonstration site, with a floor size of 4,462 ft 2 , air leakage has reduced by more than 50% in less than 7 hours, including preparation, site sealing, and cleanup. The performance objectives were classified as quantitative or qualitative based on the evaluation metrics used to assess the project’s success. The key performance objectives for this project were the level of airtightness achieved, the time and cost required to perform the sealing, and the HVAC load reduction attributable to air sealing. Table 1 shows the quantitative performance objectives.

42 ENGINEERING↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

Re-Envisioning RCx: Achieving Max Potential HVAC Controls Retrofits through Modernized BAS Hardware and Software

Most existing buildings have sub-optimal heating, ventilation, and air conditioning (HVAC) controls, resulting in wasted energy and occupant discomfort. Retro-commissioning (RCx) addresses many of these issues, but it is a lengthy and highly customized process. Limited capabilities of existing building automation system hardware restricts the scope of most RCx projects. Incentive programs consider building automation system (BAS) hardware retrofits to be high-capital investments and do not allow them in typical RCx programs. This paper describes work that the authors are leading to facilitate technical and market innovation in the BAS industry to unlock large savings in existing commercial buildings through deep retrofits of BAS hardware and software. California and New York research projects are demonstrating BAS retrofits leveraging the American Society of Heating, Refrigeration, and Air Conditioning Engineers’ (ASHRAE) new Guideline 36 high performance sequences of operation to achieve greater than 20 percent whole building energy savings, while saving costs and reducing risk through streamlined processes and standardization across BAS manufacturer product lines and across implementation practices. This paper describes market barriers that impede achieving deep savings from BAS retrofits in custom incentive and traditional RCx programs and presents a new maximum potential BAS retrofit model that addresses these barriers. The new model leverages the authors’ efforts in market enablement through open standards, BAS industry partnerships, and tools for cost-effective scaling that includes tools for project screening, savings calculations, and measurement and verification (M&V). This approach is widely applicable and will be ready for at-scale implementation within two years.

Paliaga, Gwelen↗

A Three-in-One Hybrid Strategy for High-Performance Semiconducting Polymers Processed from Anisole

The development of semiconducting polymers with good processability in green solvents and competitive electrical performance is essential for realizing sustainable large-scale manufacturing and commercialization of organic electronics. A major obstacle is the processability-performance dichotomy that is dictated by the lack of ideal building blocks with balanced polarity, solubility, electronic structures, and molecular conformation. Herein, through the integration of donor, quinoid and acceptor units, an unprecedented building block, namely TQBT, is introduced for constructing a serial of conjugated polymers. The TQBT, distinct in non-symmetric structure and high dipole moment, imparts enhanced solubility in anisole—a green solvent—to the polymer TQBT-T. Furthermore, PTQBT-T possess a highly rigid and planar backbone owing to the nearly coplanar geometry and quinoidal nature of TQBT, resulting in strong aggregation in solution and localized aggregates in film. Remarkably, PTQBT-T films spuncast from anisole exhibit a hole mobility of 2.30 cm 2 V -1 s -1 , which is record high for green solvent-processable semiconducting polymers via spin-coating, together with commendable operational and storage stability. The hybrid building block emerges as a pioneering electroactive unit, shedding light on future design strategies in high-performance semiconducting polymers compatible with green processing and marking a significant stride towards ecofriendly organic electronics.

36 MATERIALS SCIENCE↗

High-performance n-Type Polymers Based on Multiple Electron-withdrawing Groups Decorated ( E )-1,2-Di(thiophen-2-yl)ethene Building Blocks

The performance of n-type conjugated polymers lags far behind that of p-type polymers, which significantly restricts the development of organic electronics. The (E)-1,2-di(thiophen-2-yl)ethene (TVT) unit, owing to its unique advantages, has been widely applied in the design of p-type polymer semiconductors. Previous studies have demonstrated that introducing electron-withdrawing groups can lower the frontier orbital energy levels of polymers and enhance electron injection/transporting capabilities. Based on this, we proposed incorporating multiple electronwithdrawing groups, such as amide groups, fluorine atoms, and cyano groups, into the polymer backbones of TVT-based polymer to facilitate the electron transport. Here, we successfully designed and synthesized the polymers TVTDA-4FTVT and TVTDA-2F2CNTVT. Both polymers exhibited low frontier orbital energy levels. Due to its significantly higher crystallization tendency and favorable intermolecular packing structure, the organic field-effect transistor (OFET) device based on TVTDA-4FTVT demonstrated an electron mobility one order of magnitude higher than that of TVTDA-2F2CNTVT. TVTDA-4FTVT showed the highest electron mobility of 0.87 cm 2 ·V −1 ·s −1 , while TVTDA-2F2CNTVT exhibited the highest electron mobility of 0.049 cm 2 ·V −1 ·s −1 . Owing to its deeper lowest unoccupied molecular orbital (LUMO) level, the OFET devices based on TVTDA-2F2CNTVT showed good air stability after being placed in a natural environment for 15 d.

36 MATERIALS SCIENCE↗

Modular Power Electronics Approach for High Power Dynamic Wireless Charging System

Dynamic wireless power transfer (DWPT) can provide energy to EVs in motion and extend the drive range. Upscaling the charging power to 200 kW (High Power DWPT) reduces the percentage of electrified roadway required, and the solution becomes cost-effective. To smooth the power at the battery and grid, a secondary regulation stage must be added. The DWPT system therefore relies on power electronics to interface with the coils and regulate the power flow. Designing this high power system using wide bandgap devices makes ensuring high efficiency, small size, and reliable operation very challenging, and significant engineering effort is required to build such complicated systems for large-scale installation and deployment. Here, this paper describes a modular design approach for the power electronics to achieve the 200 kW wireless power transfer. As described, the SiC power electronics building block is designed, simulated, and characterized. The approach is validated in the DWPT system to build the inverter, the rectifier, and the DC/DC converter, which demonstrated high performance and reliable operation with 188 kW power.

42 ENGINEERING↗

Control And Optimization Modular Modeling Application For Nuclear Deployment

The purpose of the COMMAND code is to provide a flexible, scalable tool for use in developing, integrating, and testing the technologies necessary for achieving autonomous operations of advanced nuclear reactors. The code enables users to efficiently implement custom simulations and experiments by combining key methods from different software modules. These modules are focused on: modeling and simulation tools, such as nuclear simulation tools used for high-fidelity modeling (e.g., Reactor Excursion and Leak Analysis Program [RELAP5-3D] and Monte Carlo N-Particle [MCNP]); machine learning and optimization tools (e.g., anomaly detection and data-driven modeling techniques); advanced control in its digital, high-performance, and supervisory control forms (e.g., proportional integral derivative (PID) control and model predictive control (MPC); and integration with hardware through industrial communication protocols. To ensure flexibility and scalability, COMMAND was designed to be both modular—the software “pieces” all inherit from generic building blocks and can be combined and connected to create complicated simulations—and high performing—designed for parallel processing, enabling simulations and experiments to take advantage of multi-core computers, servers, and nodes. The code is written in the Python programming language due to the language's popularity, active community, and open-source and cross-platform nature. Maintaining consistency with other simulation tools used within the nuclear energy community, users implement simulations and experiments through text input files, which define components, parameters, connections, etc., through lines of text. Given that COMMAND is written in Python, these input files are native Python scripts, and so use the standard Python structure and formatting. This also enables users to take advantage of Python's extensive package library to develop custom capabilities for their specific use cases.

Faber, Jacob [Idaho National Laboratory (INL), Ida↗

Coupling multi-fidelity xRAGE with machine learning for graded inner shell design optimization in double shell capsules

Bayesian optimization has shown promise for the design optimization of inertial confinement fusion targets. Specifically, in Vazirani et al. [Phys. Plasmas 28 , 122709 (2021)], optimal designs for double shell capsules with graded inner shells were identified using one-dimensional xRAGE simulation yield calculations. While the machine learning models were able to accurately learn and predict one-dimensional simulation target performance, using simulations with higher fidelity would improve design optimization and better match with the expected experimental performance. However, higher fidelity physics modeling, i.e., two-dimensional xRAGE simulations, requires significantly larger computational time/cost, usually at least an order of magnitude, in comparison with one-dimensional simulations. This study presents a multi-fidelity Bayesian optimization, in which the machine learning model leverages low-fidelity (one-dimensional xRAGE) and high-fidelity (two-dimensional xRAGE) simulations to more accurately predict “pre-shot” target performance with respect to the expected experimental performance. By building a multi-fidelity Bayesian optimization framework coupled with xRAGE, the low-fidelity and high-fidelity simulations are able to inform one another, such that we have: (1) improved physics modeling in comparison with using low-fidelity simulations alone, (2) reduced computational time/cost in comparison with using high-fidelity simulations alone, and (3) more confidence in the expected performance of optimized targets during real-world experiments. In the future, we plan to use this robust multi-fidelity Bayesian optimization methodology to expedite the design of graded inner shells further and eventually full capsules as a part of the current double shell campaign at the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulating energy performance of buildings: a study using eQUEST and Energy Star ® portfolio manager

Commercial buildings consume significant energy in the United States and exhibit high potential for energy use reduction through retrofits. Benchmarking and energy simulation are well established tools in the industry to identify potential improvements and measure performance. Analysis to identify most sensitive retrofit parameters to energy performance can optimize investment and available energy savings. Presented study demonstrates methodology using a static model to determine sensitivity of building design and retrofit parameters with respect to energy performance. Calibrated simulation energy models (eQUEST) of two distribution centers (A, B) are presented. A fractional factorial analysis is conducted on retrofit parameters of efficiency measures targeting the highest energy consumers, and the results are benchmarked using Energy Star® Portfolio Manager. A custom Microsoft Excel® based simulation model is created to simulate occupancy levels, lighting, plug loads, and other equipment used in various spaces throughout the day. For Building A, efficient lighting was the most influential parameter for energy savings, carbon savings and benchmarking score; whereas, for Building B, HVAC efficiency was most influential for energy and demand controlled ventilation and economizers was most influential for benchmarking score. While retrofit projects can save energy and carbon emissions, variation in source-site ratios and state grid emissions, benchmarking scores may not always reflect equivalent improvement. State grid emissions factors, natural gas composition are difficult to model and hence not considered in this study. In conclusion, the synergistic analysis presented, emphasizes the importance of benchmarking and efficiency retrofits in promoting sustainable building practices to reduce energy consumption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced Building Construction Collaborative (Final Technical Report)

This report summarizes the outcomes of RMI’s five-year U.S. Department of Energy–funded Advanced Building Construction Collaborative (ABC-C), which accelerated adoption of high-performance construction through industry collaboration, market research, technology commercialization, and demand aggregation. It highlights the Collaborative’s achievements—including engagement of more than 130 organizations, support for over $637 million in funding for ABC companies, and recommendations to scale advanced building construction through coordinated market, policy, and investment strategies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Scalable training of graph convolutional neural networks for fast and accurate predictions of HOMO-LUMO gap in molecules

Abstract Graph Convolutional Neural Network (GCNN) is a popular class of deep learning (DL) models in material science to predict material properties from the graph representation of molecular structures. Training an accurate and comprehensive GCNN surrogate for molecular design requires large-scale graph datasets and is usually a time-consuming process. Recent advances in GPUs and distributed computing open a path to reduce the computational cost for GCNN training effectively. However, efficient utilization of high performance computing (HPC) resources for training requires simultaneously optimizing large-scale data management and scalable stochastic batched optimization techniques. In this work, we focus on building GCNN models on HPC systems to predict material properties of millions of molecules. We use HydraGNN, our in-house library for large-scale GCNN training, leveraging distributed data parallelism in PyTorch. We use ADIOS, a high-performance data management framework for efficient storage and reading of large molecular graph data. We perform parallel training on two open-source large-scale graph datasets to build a GCNN predictor for an important quantum property known as the HOMO-LUMO gap. We measure the scalability, accuracy, and convergence of our approach on two DOE supercomputers: the Summit supercomputer at the Oak Ridge Leadership Computing Facility (OLCF) and the Perlmutter system at the National Energy Research Scientific Computing Center (NERSC). We present our experimental results with HydraGNN showing (i) reduction of data loading time up to 4.2 times compared with a conventional method and (ii) linear scaling performance for training up to 1024 GPUs on both Summit and Perlmutter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

How will United States commercial building energy use be impacted by IPCC climate scenarios?

Climate change and anthropogenically-forced shift of weather in the future will impact energy use and resilience of both the built environment and the electric grid. The aim of this analysis is to understand how future climate scenarios will impact electricity and natural gas use of commercial buildings in the United States. Here, this study analyzes this impact for 2030, 2045, and 2100 using Representative Concentration Pathways (RCP) scenarios defined in Intergovernmental Panel on Climate Change (IPCC) Assessment Report 5. The large, gridded simulation of meteorological variables for RCPs 2.6, 4.5, 6.0, and 8.5 are selected and downscaled to make available hourly Future Meteorological Year (FMY) weather files for use and improvement in subsequent studies. High performance computing resources use these FMYs to simulate commercial prototype buildings in every American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) climate zone of the United States (US), and results are scaled to nation-wide energy use using conditioned floor area multipliers. The analysis is conducted without speculating the physical and performance traits of future buildings or the grid characteristics. This analysis quantifies the impact of climate change on source electrical and natural gas usage for commercial buildings in the United States over the next 80 years. If US commercial floorspace remained constant, total energy use by 2100 is predicted between an 1.75% decrease under the greatest emission scenario (8.5) and a 1.76% increase under the lowest emission scenario (2.6). When adjusted for anticipated urban growth by 2100, the predicted range is 65% increase (8.5) and 71% increase (2.6). Under a global temperature rise climate scenario, the warmest US climate zones will see a large increases in electricity use derived from space cooling while the coldest US climate zones will see significant decreases in natural gas use caused by the decrease in heating necessary. While climate change may ultimately require adaptations of the built environment to withstand its effects and because the United States is a country that requires more heating than cooling, from a building energy perspective, climate change (average temperature rise) is a net energy saver for the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robotically Assembled Aerospace Structures: Digital Material Assembly using a Gantry-Type Assembler

This paper evaluates the development of automated assembly techniques for discrete lattice structures using a multi-axis gantry type CNC machine. These lattices are made of discrete components called digital materials. We present the development of a specialized end effector that works in conjunction with the CNC machine to assemble these lattices. With this configuration we are able to place voxels at a rate of 1.5 per minute. The scalability of digital material structures due to the incremental modular assembly is one of its key traits and an important metric of interest. We investigate the build times of a 5x5 beam structure on the scale of 1 meter (325 parts), 10 meters (3,250 parts), and 30 meters (9,750 parts). Utilizing the current configuration with a single end effector, performing serial assembly with a globally fixed feed station at the edge of the build volume, the build time increases according to a scaling law of n4, where n is the build scale. Build times can be reduced significantly by integrating feed systems into the gantry itself, resulting in a scaling law of n3. A completely serial assembly process will encounter time limitations as build scale increases. Automated assembly for digital materials can assemble high performance structures from discrete parts, and techniques such as built in feed systems, parallelization, and optimization of the fastening process will yield much higher throughput.

Mechanical Structure↗