Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SPC-71145 Rev 0 MARVEL Process Heat Extraction System Conceptual Design

The Microreactor Applications Research Validation and Evaluation (MARVEL) reactor will offer experimental capabilities that are not currently available at DOE’s national laboratories. The MARVEL reactor is a microreactor which uses eutectic sodium-potassium alloy (NaK) as a primary coolant. The primary coolant is circulated through four primary loops by natural convection of the coolant. In each loop is a closed well which will accommodate an intermediate heat exchanger (IHX) for extracting heat from the loop. These wells will be referred to in this specification as the “IHX wells”. It is intended for the IHX containment to also be filled with NaK. The MARVEL design team is currently looking for alternative means of extracting heat from these wells to be utilized in downstream applications. This Heat Utilization System (HUS) will enable MARVEL operations including the ability to test, demonstrate, and address issues related to installation, startup, and operations. In addition, it will allow down-stream utilization of process heat for various uses. Depending on the methodology used, the interface between the secondary coolant and the HUS is the Process Heat Extraction System (PHES) and is the subject of this specification.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Determination of a version of a unit for synchronous cleaning and utilization of gas exhausts from heat generators

Versions for performing synchronous cleaning and utilization of flue gases, calculation schemes and basic equations for defining them, engineering schemes with an indication of the main equipment for these versions, are considered. The possibility is demonstrated of improving the ecological safety of a boiler unit simultaneously with a reduction in discharge of heat into the environment.

01 COAL, LIGNITE, AND PEAT↗

An advanced membrane-based HMX model and its application in utilizing sensible and latent heat removed in space cooling

This paper presents a comprehensive simulation model for advanced membrane-based heat and mass exchanger (HMX) components which account for three separate fluid streams with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl and ionic liquid (IL)). Preliminary model validation is presented using data from a laboratory prototype absorber. The paper also presents implementation of the model into a sorption system modeling platform and analyzes potential benefit analysis of the HMX component in utilizing the sensible and latent heat removed in space cooling to heat water. The developed model and codes are expected to enable detailed optimization studies and identify novel configurations for the three-fluid HMX maximum performance and cost effectiveness.

Gao, Zhiming↗

Water treatment capacity of forward osmosis systems utilizing power plant waste heat

Forward osmosis (FO) has the potential to improve the energy efficiency of membrane-based water treatment by leveraging waste heat from steam electric power generation as the primary driving force for separation. In this study, we develop a comprehensive FO process model, consisting of membrane separation, heat recovery, and draw solute regeneration (DSR) models. We quantitatively characterize three alternative processes for DSR: distillation, steam stripping, and air stripping. We then construct a mathematical model of the distillation process for DSR that incorporates hydrodynamics, mass and heat transport resistances, and reaction kinetics, and we integrate this into a model for the full FO process. Finally, we utilize this FO process model to derive a first-order approximation of the water production capacity given the rejected heat quantity and quality available at U.S. electric power facilities. We find that the upper bound of FO water treatment capacity using low-grade heat sources at electric power facilities exceeds process water treatment demand for boiler water make-up and flue gas desulfurization wastewater systems.

20 FOSSIL-FUELED POWER PLANTS↗

Heat Transfer, Refrigeration and Heat Pumps

The Special Issue entitled “Heat Transfer, Refrigeration and heat Pumps” accepted papers covering a wide range of topics related to heat pumps, thermal energy storage, and low-Global Warming Potential (GWP) alternative refrigerants. Heat pumps play a vital role in providing space conditioning and water heating while utilizing the energy of the environment. Since heat pumps use renewable thermal energy from the environs to provide the desired utility, they contribute to the portfolio of technologies that mitigate carbon footprint. The heat pump may be considered a truly renewable technology if the electricity it uses comes entirely from a renewable source. More accurately, a heat pump is a “low carbon technology”. These perspectives make heat pumps an indispensable option for the future in order to reduce the nocuous human impact on the environment. More efficient heat pumping technologies are being developed for the residential, commercial, and industrial sectors of the economy. Another R&D thrust is heat pumps for cold climates. Hardware components, use of low-GWP refrigerants, and identification of systemic inefficiencies are active research areas. This article is a synopsis of the papers submitted to the Special Issue.

42 ENGINEERING↗

Apparatus for improving the fuel efficiency of a gas turbine engine

An energy recovery system is provided for an aircraft gas turbine engine of the type in which some of the pneumatic energy developed by the engine is made available to support systems such as an environmental control system. In one such energy recovery system, some of the pneumatic energy made available to but not utilized by the support system is utilized to heat the engine fuel immediately prior to the consumption of the fuel by the engine. Some of the recovered energy may also be utilized to heat the fuel in the fuel tanks. Provision is made for multiengine applications wherein energy recovered from one engine may be utilized by another one of the engines or systems associated therewith.

Coffinberry, G. A.↗

Method for improving the fuel efficiency of a gas turbine engine

An energy recovery system is provided for an aircraft gas turbine engine of the type in which some of the pneumatic energy developed by the engine is made available to support systems such as an environmental control system. In one such energy recovery system, some of the pneumatic energy made available to but not utilized by the support system is utilized to heat the engine fuel immediately prior to the consumption of the fuel by the engine. Some of the recovered energy may also be utilized to heat the fuel in the fuel tanks. Provision is made for multiengine applications wherein energy recovered from one engine may be utilized by another one of the engines or systems associated therewith.

Coffinberry, G. A.↗

Utilization of Micro Tube Heat Exchanger for Next Generation Phase Change Material Heat Exchanger Development

Abstract and not the Final document is attached. Low Lunar orbit presents a unique thermal environment with high planetary and high solar IR requirements. Orion requires a phase change material heat exchanger (PCM HX) to act as a supplemental heat rejection device (SHReD) during this orbit. As a result, Orion currently uses a PCMHX to meet heat rejection demands in low lunar orbit. This PCM HX weighs 145 lbs, a significant amount of weight on the Crew Module Adaptor. To reduce this weight, a new PCM HX and phase change material is being proposed. This new PCM HX, constructed by Mezzo technologies, was originally designed as a water based PCM HX but is now be repurposed for phase change materials with transition temperatures in Orion's set points and different freeze front propagations. Mezzo's PCM HX utilizes micro tubes which greatly increase the overall heat transfer efficiency allowing for a compact design and significant weight savings. A new phase change material is also being proposed which has a higher latent heat of fusion as well as a higher density. This paper investigates the design, testing, and analysis done on the new Mezzo PCM HX as well as the corresponding phase change material.

Foley, Lauren A.↗

Assessment of solar-assisted gas-fired heat pump systems

As a possible application for the Goldstone Energy Project, the performance of a 10 ton heat pump unit using a hybrid solar gas energy source was evaluated in an effort to optimize the solar collector size. The heat pump system is designed to provide all the cooling and/or heating requirements of a selected office building. The system performance is to be augmented in the heating mode by utilizing the waste heat from the power cycle. A simplified system analysis is described to assess and compute interrrelationships of the engine, heat pump, and solar and building performance parameters, and to optimize the solar concentrator/building area ratio for a minimum total system cost. In addition, four alternative heating cooling systems, commonly used for building comfort, are described; their costs are compared, and are found to be less competitive with the gas solar heat pump system at the projected solar equipment costs.

Lansing, F. L.↗

A prototype photovoltaic/thermal system integrated with transpired collector

Building-integrated photovoltaic/thermal (BIPV/T) systems may be utilized to produce useful heat while simultaneously generating electricity from the same building envelope surface. A well known highly efficient collector is the open-loop unglazed transpired collector (UTC) which consists of dark porous cladding through which outdoor air is drawn and heated by absorbed solar radiation. Commercially available photovoltaic systems typically produce electricity with efficiencies up to about 18%. Thus, it is beneficial to obtain much of the normally wasted heat from the systems, possibly by combining UTC with photovoltaics. Combination of BIPV/T and UTC systems for building facades is considered in this paper - specifically, the design of a prototype facade-integrated photovoltaic/thermal system with transpired collector (BIPV/T). A full scale prototype is constructed with 70% of UTC area covered with PV modules specially designed to enhance heat recovery and compared to a UTC of the same area under outdoor sunny conditions with low wind. The orientation of the corrugations in the UTC is horizontal and the black-framed modules are attached so as to facilitate flow into the UTC plenum. While the overall combined thermal efficiency of the UTC is higher than that of the BIPV/T system, the value of the generated energy - assuming that electricity is at least four times more valuable than heat - is between 7% and 17% higher. Also, the electricity is always useful while the heat is usually utilized only in the heating season. The BIPV/T concept is applied to a full scale office building demonstration project in Montreal, Canada. The ratio of photovoltaic area coverage of the UTC may be selected based on the fresh air heating needs of the building, the value of the electricity generated and the available building surfaces. (author)

14 SOLAR ENERGY↗

Appalachian Basin Play Fairway Analysis Analyses and Results

*This submission updates a 2015 submission for the utilization analysis (https://gdr.openei.org/submissions/623)* The files document the analysis of utilization potential in support of Phase 1 Low Temperature Geothermal Play Fairway Analysis for the Appalachian Basin. This 2016 submission includes data pertinent to the methods and results of an analysis of the Surface Levelized Cost of Heat (SLCOH) for US Census Bureau 'Places' within the study area. The SLCOHis was calculated using a modification of a program called GEOPHIRES, available at http://koenraadbeckers.net/geophires/index.php. In addition to calculating SLCOH, this task also identified many industrial sites that may be prospects for use of a geothermal district heating system, based on their size and industry, rather than on the SLCOH. An industry sorted listing and maps of the sites have been plotted as a layer onto different iterations of maps combining the three geologic risk factors (Thermal Quality, Natural Reservoir Quality, and Risk of Seismicity). In addition, a shapefile of the industrial sites is also included with 7 associated files. Supporting files are also supplied.

15 GEOTHERMAL ENERGY↗

Particulate matter emissions from combustion of wood in district heating applications

The utilization of wood biomass to generate district heat and power in communities that have access to this energy source is increasing. In this paper the effect of wood fuel properties, combustion condition, and flue gas cleaning system on variation in the amount and formation of particles in the flue gas of typical district heating wood boilers are discussed based on the literature survey. Direct measurements of particulate matter (PM) emissions from wood boilers with district heating applications are reviewed and presented. Finally, recommendations are given regarding the selection of wood fuel, combustion system condition, and flue gas cleaning system in district heating systems in order to meet stringent air quality standards. It is concluded that utilization of high quality wood fuel, such as wood pellets produced from natural, uncontaminated stem wood, would generate the least PM emissions compared to other wood fuel types. Particulate matter emissions from grate burners equipped with electrostatic precipitators when using wood pellets can be well below stringent regulatory emission limit such as particulate emission limit of Metro Vancouver, Canada.

09 BIOMASS FUELS↗

Techno-economic analysis of high-efficiency natural-gas generators for residential combined heat and power

Residential combined heat and power (CHP) systems produce electricity onsite while utilizing waste heat to supplement home heating requirements, which can lead to significant reductions in CO 2 emissions and primary energy consumption. However, the current deployment of such CHP systems in the U.S. residential sector is extremely low primarily due to their high cost, short system life, and low system efficiency. Based on an analysis of average energy consumption of representative single-family homes in 10 U.S. cities across 7 different climate zones, it is concluded that there is no one-size-fits-all residential CHP system, but that a range of products are more likely to reflect consumer preferences. It is further identified via a systematic techno-economic analysis (TEA) that high-efficiency (e.g., 30% - 40% fuel to electricity), long-life (e.g., 15 years), low-cost (preferably less than U.S. $2,500 installed price), and low emissions are key requirements to enable widespread deployment of CHP systems in the U.S. residential sector. This article analyzes how the payback period would change for each city by varying nearly a dozen parameters and concludes with an evaluation on maximum market penetration based on a given set of parameters, and the resulting energy and emissions savings that can be practically achieved in some scenarios.

03 NATURAL GAS↗

Carbothermic Reduction Kinetics of Phosphorous Vaporization from Tri-calcium Phosphate (TCP) Under Microwave Rapid Heating With/Without the Presence of Fe{sub 3}O{sub 4}

The kinetics of vapor phase dephosphorization from tri-calcium phosphate (TCP) by carbothermic reduction was studied with and without the presence of Fe{sub 3}O{sub 4}. Microwave heating was utilized to obtain large variations in the heating rate (HR). In the reduction of TCP alone, the phosphorous removal fraction (RF; equal to ∆P{sub 2}O{sub 5}/P{sub 2}O{sub 5}{sup 0}, where ∆P{sub 2}O{sub 5} is the weight change and P{sub 2}O{sub 5}{sup 0} is the P{sub 2}O{sub 5} weight before heating) decreased as the HR increased. In other words, a shorter residence time at a high temperature resulted in a smaller reduction fraction of TCP. An apparently third-order reaction was postulated to account for the kinetics using a fitting simulation based on the additive law of the reaction progress. On the other hand, the phosphorous removal (dephosphorization) rate (RR; equal to ∆P{sub 2}O{sub 3}/t{sub MW}, where t{sub MW} is the microwave heating time period) increased as the HR increased above 1200 °C. The reduction ratio of Fe{sub 3}O{sub 4} above 1100 °C is higher than 97 pct regardless of the heating rate. The reduction of TCP in the presence of Fe{sub 3}O{sub 4} showed that RF increased slightly with increasing HR despite a shorter residence time at a high temperature. The RR also increased with the HR even though RF decreased to half of the values observed in the cases without Fe{sub 3}O{sub 4} for temperatures above 1200 °C. The practicality and optimal operation conditions of phosphorus vapor removal were discussed.

36 MATERIALS SCIENCE↗

Localness of energy cascade in hydrodynamic turbulence, II. Sharp spectral filter

We investigate the scale-locality of subgrid-scale (SGS) energy flux and interband energy transfers defined by the sharp spectral filter. We show by rigorous bounds, physical arguments, and numerical simulations that the spectral SGS flux is dominated by local triadic interactions in an extended turbulent inertial range. Interband energy transfers are also shown to be dominated by local triads if the spectral bands have constant width on a logarithmic scale. We disprove in particular an alternative picture of 'local transfer by nonlocal triads,' with the advecting wavenumber mode at the energy peak. Although such triads have the largest transfer rates of all individual wavenumber triads, we show rigorously that, due to their restricted number, they make an asymptotically negligible contribution to energy flux and log-banded energy transfers at high wavenumbers in the inertial range. We show that it is only the aggregate effect of a geometrically increasing number of local wavenumber triads which can sustain an energy cascade to small scales. Furthermore, nonlocal triads are argued to contribute even less to the space-average energy flux than is implied by our rigorous bounds, because of additional cancellations from scale-decorrelation effects. We can thus recover the -4/3 scaling of nonlocal contributions to spectral energy flux predicted by Kraichnan's abridged Lagrangian-history direct-interaction approximation and test-field model closures. We support our results with numerical data from a 512{sup 3} pseudospectral simulation of isotropic turbulence with phase-shift dealiasing. We also discuss a rigorous counterexample of Eyink [Physica D 78, 222 (1994)], which showed that nonlocal wavenumber triads may dominate in the sharp spectral flux (but not in the SGS energy flux for graded filters). We show that this mathematical counter example fails to satisfy reasonable physical requirements for a turbulent velocity field, which are employed in our proof of scale locality. We conclude that the sharp spectral filter has a firm theoretical basis for use in large-eddy simulation modeling of turbulent flows.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SPC-71260 Rev 0 MARVEL Heat Extraction Subsystem Secondary Coolant Equipment (SCE) Design/Build

A. The Microreactor Applications Research Validation and Evaluation (MARVEL) reactor will offer experimental capabilities that are not currently available at DOE’s national laboratories. Idaho National Laboratory (INL), operated for the U.S. Department of Energy (DOE) by Battelle Energy Alliance, LLC (BEA) (Contractor hereafter) is procuring services for the design, analysis, fabrication, testing and delivery of a Secondary Coolant Equipment system (SCE). This specification contains the requirements for design, analysis, fabrication, testing and delivery of the SCE as described herein. The MARVEL reactor is a microreactor which uses eutectic sodium-potassium alloy (NaK) as a primary coolant. The primary coolant is circulated through four primary loops by natural convection of the coolant. In each loop is a closed well which will accommodate an intermediate heat exchanger (IHX) for extracting heat from the loop. These wells will be referred to in this specification as the “IHX wells.” It is intended for the IHX containment to also be filled with NaK. The MARVEL design team has determined that a Heat Extraction System (HES) using pumped NaK will be used to extract heat from the IHXs and deliver it to a downstream system for power generation or alternate process heat users. This Heat Extraction System will enable MARVEL operations including the ability to test, demonstrate, and address issues related to installation, startup, and operations. In addition, it will allow down-stream utilization of process heat for various uses. The objective of this specification is to develop the final design for the HES Secondary Coolant Equipment system (SCE) that will be used as the core of the HES. This system provides control of the NaK circulation between the MARVEL reactor and the subsequent process heat utilization systems. It does not include design of the Intermediate Heat Exchangers and piping inside the T-REXc pit in which the reactor is located. B. The MARVEL microreactor will be installed in the Transient Reactor Test Facility (TREAT) building in the Transient Reactor Test (TREAT) Micro-Reactor Experiment Cell (T-REXc) C. An INL Subcontractor has developed a conceptual design for this system per SPC-71145, referred to in that specification as the Process Heat Extraction System. SPC-71260 is based on the pumped NaK loop concept developed under SPC-71145. D. The SCE system design and (as option scope) fabrication shall be provided by the awardee of the subcontract (Subcontractor hereafter) pertaining to this Specification. Prior to shipment, the SCE will be fabricated, assembled, and tested at the Subcontractor’s facility. After successful completion of acceptance testing, the SCE and associated equipment will be shipped to the Materials and Fuels Complex (MFC) at the INL (Contractor’s Facility hereafter) to be installed by others in TREAT/T-REXc.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Review and Modeling of Integrated Energy Systems with Nuclear Reactor Coupled Desalination and District Heating

Detailed reviews of a past advanced nuclear reactor based integrated energy system, as well as other nuclear reactor and fossil fuel based integrated energy systems have been performed for this work. Review of the utilization of heat from nuclear reactors for various applications and cogeneration has been done. The heat can be utilized by extraction of the steam from the turbine while the steam is still at a desired temperature. While use of nuclear process heat for district heating in countries like Finland, France, China, Poland, and elsewhere is discussed, more focus of the review has been given on nuclear desalination processes. Integrated energy systems (IES) where distinct types of reactors like PWR, BWR, sodium cooled fast reactor, heavy water reactor and other advanced reactors are coupled with various nuclear desalination processes like multi-effect distillation (MED), multi-stage flashing (MSF) and reverse osmosis (RO) methods have been discussed. The nuclear desalination plant at Aktau has been discussed in more detail due to its decades of successful operation. The IES of the Aktau plant coupled with 5-effect MED desalination plant has been taken as a reference for modeling the Open Modelica (OM) based IES of this work. Here, the OM IES model shows good agreement with the MED plant output of Aktau and can be extended for future applications of IES.

42 ENGINEERING↗

Design, modeling and simulation of nuclear-powered integrated energy systems with cascaded heating applications

Nuclear-renewable integrated energy systems (IES) consist of a variety of energy generation and conversion technologies and can be used to meet heterogeneous end uses (e.g., electricity, heat, and cooling demands). In addition to supply-demand balance, end-use heat demands usually require heat supply of certain temperature ranges. The effective and efficient utilization of heat produced within an IES is, therefore, a critical challenge. Here, this paper examines design options of an IES that includes heating processes of multiple temperature grades. We investigate a cascaded design configuration, where the remaining residual heat after high-grade heating processes [e.g., hydrogen production through high-temperature steam electrolysis (HTSE)] is recovered to meet the low-grade heating needs [e.g., district heating (DH)]. Additionally, a thermal energy storage system is integrated into the DH system to address the imbalance between heat supply and demand. This paper primarily focuses on the design and modeling of the proposed system and evaluates its operation with a 24-h transient process simulation using a DH demand profile with hourly resolution. The results indicate that the residual heat from the HTSE exhaust is insufficient for the DH demand, and additional topping heat directly from the reactor process steam is needed. Furthermore, the inclusion of thermal energy storage within the DH system provides the necessary balance between thermal generation and demand, thereby ensuring a consistent rated temperature of the DH supply water. This approach helps minimize the control actions needed on the reactor side.

08 HYDROGEN↗