Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guidance document”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SNS Resonance Control Cooling Systems and Quadrupole Magnet Cooling Systems DIW Chemistry

This report focuses on control of the water chemistry for the Spallation Neutron Source (SNS) Resonance Control Cooling System (RCCS)/Quadrupole Magnet Cooling System (QMCS) deionized water (DIW) cooling loops. Proper cooling-water chemistry is essential to preserving the DTL and CCL structures during their design lifetime. Appropriate water chemistry will protect cooling-water passages and brazed joints of the structure from erosion, corrosion, and fouling. The RCCS/QMCS DIW chemistry is managed by sidestreams built into the cooling loops; chemicals are not used. Data collected from spring 2013 through spring 2016 are discussed, and an operations regime is recommended. During the evaluation period, the pH, dissolved oxygen, and water resistivity of the cooling water were observed. The data were collected by instruments mounted on mobile chemistry carts, which were moved from one RCCS/QMCS DIW skid to another. During data reading, operational corrections were done on the polishing loops to improve the water chemistry regime. Therefore some trends changed over time. It was found that the RCCS operates with an average pH of 7.24 for all lines (from 7.0 to 7.5, slightly alkaline), the average low dissolved oxygen is in the area of < 36 ppb, and the main loop average resistivity of is > 14 MΩ-cm. The QMCS was found to be operating in a similar regime, with a pH of about 7.5 (slightly alkaline), low dissolved oxygen in the area of < 45 ppb, and main loop resistivity of 10 to 15 MΩ-cm. It is recommended that the cooling loops operate in a regime in which the water has a resistivity that is as high as achievable, a dissolved oxygen concentration that is as low as achievable, and a neutral or slightly alkaline pH. An RCCS/QMCS chemistry guidance document published in May 2017 describes and standardizes the methods and practices for water chemical treatment for the SNS RCCS and QMCS. It is very difficult to accurately measure the pH, dissolved oxygen, and water resistivity in highly pure water. Therefore, a regularly scheduled calibration program will be established for the instruments. Recommendations are given at the end of the report on how to run the RCCS/QMCS cooling water chemistry. Chemical analysis of the material trapped by the polishing loop prefilters is conducted twice a year. The analysis and its benefits are described in Chapter 9.

42 ENGINEERING↗

Coiled Tube Gas Heaters For Nuclear Gas-Brayton Power Conversion

This project developed an alternative design for heat exchangers for application to heating supercritical carbon dioxide (S-CO 2 ) or air for power conversion. We have identified an annular coiled tube bundle configuration–where hot sodium enters tubes from multiple vertical inlet manifold pipes, flows in a spiral pattern radially inward and downward, and then exits into an equal number of vertical outlet manifold pipes–as a potentially attractive option. The S-CO 2 gas or air flows radially outward through the tube bundle. Coiled tube gas heaters (CTGHs) are expected to have excellent thermal shock, long-term thermal creep, in-service inspection, and reparability characteristics, compared to alternative options. CTGHs have significant commonality with modern nuclear steam generators. Extensive experience exists with the design, manufacture, operation, in-service inspection and maintenance of nuclear steam generators. The U.S. Nuclear Regulatory Commission also has extensive experience with regulatory guidance documented in NUREG 0800. CTGHs leverage this experience and manufacturing capability. The most important difference between steam generators and gas-Brayton cycles such as the S-CO 2 cycle is that the heat exchangers must operate with counter flow with high effectiveness to minimize the pinch-point temperature difference between the hot liquid coolant and the heated gas. S-CO 2 -cycle gas heaters also operate at sufficiently elevated temperatures that time dependent creep is important and allowable stresses are relatively low. Designing heat exchangers to operate in this regime requires configurations that minimize stresses and stress concentrations. The cylindrical tubes and cylindrical manifold pipes used in CTGHs are particularly effective geometries. The first major goal of this research project was to develop and experimentally validate a detailed, 3-D multi-phase (gas-solid-liquid) heat transport model for CTGHs, using methods similar to earlier UCB multi-scale models for PCHEs, which will enable optimization of CTGH designs with respect to the number of manifold pipes, S-CO 2 and sodium circulating power, and other design parameters. CTGHs are relatively novel because the tubes loaded in compression as well as the manifold pipes which form the tube sheets. The second major goal of the experimental and modeling effort was to optimize the assembly and heat treatment of the tube-to-tubesheet joints, using a novel tapered joint configuration, and to develop diffusion-bonded joints with high shear strength and creep resistance, as has been done in other applications for tapered plugs. The project would also conduct creep testing of these tubesheet joints in pressurized furnaces under prototypical conditions of stress and temperature, however this was not feasible due to numerous hinderances. Detailed microstructural investigations was conducted on the diffusion bond interface, while the bond strength was evaluated by tensile testing. The mechanical testing quantified the overall strength of the bond and measured the pull out force as well as long term behavior, which complemented the microstructural analysis and gave a complete understanding of the diffusion bond.

30 DIRECT ENERGY CONVERSION↗

PRA technology and regulatory perspectives P-111

The course is divided into two parts. The first part of the course presents basic PRA concepts and terminology in a lecture format supplemented with student exercises, some exercises using actual plant PRAs, and required reading of agency PRA policy and guidance documents. This portion of the course includes a closed-book exam at the beginning of the second week. The second part of the course is a series of integrated workshops that build upon the material presented in the first part of the course. The second part culminates with an open-book exam at the end of the second week.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Contaminant Attenuation and Transport Characterization of 200-DV-1 Operable Unit Sediment Samples from Boreholes C9497, C9498, C9603, C9488, and C9513

Contaminants disposed of at the land surface must migrate through the vadose zone before entering groundwater. Processes that occur in the vadose zone can attenuate contaminant concentrations during transport through the vadose zone. Thus, quantifying contaminant attenuation and contaminant transport processes in the vadose zone, in support of the conceptual site model (CSM) and fate and transport assessments, is important for assessing the need for, and type of, remediation in the vadose zone and groundwater. The framework to characterize attenuation and transport processes provided in U.S. Environmental Protection Agency (EPA) guidance documents was used to guide the laboratory effort reported herein.

54 ENVIRONMENTAL SCIENCES↗

Risk Evaluation for the Diesel Fuel Leak Near Generator Building TRA-674 at the Advanced Test Reactor Complex

This report describes the risk-based evaluation conducted for the underground diesel fuel leak near Generator Building TRA-674 at the Advanced Test Reactor Complex, located at the Idaho National Laboratory. The risk evaluation process followed the Idaho Risk Evaluation Manual for Petroleum Releases (August 2012) guidance document and used the Idaho Risk Evaluation Computational Software (August 2015) to estimate the human health risks posed by residual contamination. Site-specific data were collected to estimate the representative concentrations of the soil for estimating the cumulative risk. Based on historical and current data, the site does not exceed unacceptable risk to human health receptors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Geochemical, Microbial, and Physical Characterization of 200-DV-1 Operable Unit B-Complex Cores from Boreholes C9552, C9487, and C9488 on the Hanford Site Central Plateau

The 200-DV-1 Operable Unit (OU) is in the process of characterizing the vadose zone to support a remedial investigation and feasibility study. Contaminants disposed of at the land surface must migrate through the vadose zone before entering groundwater. Quantifying contaminant attenuation and contaminant transport processes in the vadose zone, in support of the conceptual site model (CSM) and fate and transport modeling, are important for assessing the needs for, and types of, remediation in the vadose zone and groundwater. The framework to characterize attenuation and transport processes provided in U.S. Environmental Protection Agency (EPA) guidance documents was used to guide the laboratory effort with the following objectives:

54 ENVIRONMENTAL SCIENCES↗

Risk-Informed Performance-Based Technology. Inclusive Guidance for Advanced Reactor Licensing Basis Development (NEI 18-04)

This guideline presents a modern, technology-inclusive, risk-informed, and performance-based (TI-RIPB) process for selection of Licensing Basis Events (LBEs); safety classification of structures, systems, and components (SSCs) and associated risk-informed special treatments; and determination of defense-in-depth (DID) adequacy for non-LWRs. This guidance document provides one acceptable means for addressing the aforementioned topics as part of demonstrating a specific design provides reasonable assurance of adequate radiological protection.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving the Nuclear Data on Fission Product Decays at CARIBU: LL18-FissProdCARIBU-PD3Jb TRA 2018

The scope of the project is to improve the fundamental nuclear data of fission products relevant to applications. Per the TRA guidance document “We will improve the precision of the absolute g-ray branching ratios for longlived fission products by nearly an order of magnitude to 1-2% precision” describes the goal of the project. This goal is unlikely to change during the course of the project.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

1st MPEX Users Research Forum (MURF) summary report: specifications for the Surface Analysis Station (SAS)

The Material Plasma Exposure eXperiment (MPEX) Team has reached out to the community of potential users of the MPEX facility to assess the high-priority capabilities which should be considered for inclusion in the design of the MPEX Surface Analysis Station (SAS). This activity is being carried out during the “advanced conceptual design” period of MPEX, i.e. post Conceptual Design Review (CDR) but prior to Preliminary Design (PD), to respond to a recommendation by the U.S. D.O.E. following the CDR. The MPEX Team will summarize the community recommendations into a guidance document (i.e. this report), which will influence the Surface Analysis Station during the Preliminary Design phase of the project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy Intensity Baselining and Tracking Guidance

Each company joining the U.S. Department of Energy’s (DOE’s) Better Buildings, Better Plants Program (Better Plants) commits to establishing an energy consumption and energy intensity (EI) baseline and to tracking its energy performance over a 10-year period against that baseline. The baseline must reflect a company’s energy consumption over a 12-month period, covering all its U.S.-based operations. Energy consumption is calculated by fuel type in terms of primary energy (also known as source energy). EI is broadly defined as the amount of energy consumed per unit of output produced. For this guidance document and for the program, the term energy performance represents an evaluation of a facility’s capacity to use energy efficiently. Metrics used to assess a facility’s energy performance can include EI, energy consumption, improvements in EI, etc. Establishing an energy baseline and tracking system is a critical first step in effectively managing energy use. Developing a baseline can help a company understand energy use within the corporation and give it a point of comparison to evaluate future efforts to improve energy performance. It can also support efforts to validate a company’s energy management activities, improve comparative analyses when using benchmarks, and help in predicting future energy needs. In addition, a company that normalizes its performance data can determine highly defensible measures of energy savings generated through implemented energy efficiency projects. Establishing a baseline and tracking energy performance is also a requirement for ISO 50001 certification. Although basic energy data can be collected through utility bills, most manufacturers will have to perform additional analyses to develop accurate and robust energy baselines and tracking systems. Energy is consumed in many ways within the manufacturing sector and can come from multiple sources. Energy is sometimes generated and sold to other parties or captured and reused on-site. External events can exert a significant impact on a facility or company’s energy use independent of any purposeful efforts to improve energy efficiency. Operational changes, such as production shifts—which may be inevitable for some companies over the 10-year period covered by the program—can also make a big difference in energy use. Since Better Plants asks companies to account for all their U.S.-based operations, mergers, acquisitions, and divestitures can also have significant implications for a company’s energy metrics. This document aims to demystify the sometimes complex baselining process. It devotes special attention to the task of normalizing and adjusting energy consumption to account for external factors, such as weather and production changes. A key recommendation is that companies use regression analysis to normalize their energy consumption data whenever possible. Regression analysis is a statistical technique that estimates the dependence of a variable (i.e., energy use in the context of Better Plants) on one or more independent variables such as ambient temperature, while controlling for the influence of other variables at the same time. A properly developed regression analysis can provide a reliable estimate of energy savings resulting from energy improvement strategies and projects by accounting for the effects of variables such as annual production levels and weather. DOE has developed a companion Energy Performance Indicator software tool (EnPI) to simplify the baselining process. This tool can run regression models, calculate changes in EI at the facility level, and automatically compile facility-level data into a corporate-wide metric. Note that although the relevant equations used to calculate EI are provided in this document, the EnPI tool will automatically perform most calculations for the user. Additionally, Better Plants Partners (Partners) can call on their Technical Account Manager (TAM) to help them establish a baseline and assist with the necessary calculations to track progress.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Facility Cybersecurity Framework Best Practices

Federal facilities are increasingly adopting automation and connecting to the Internet creating an energy-internet-of-things environment that converges operational technology (OT) and information technology (IT). Today's buildings increasingly weave together networked sensors and cyber and physical systems that enable data to be collected, aggregated, exchanged, stored and monetized in new ways. Building technological advances have created new energy technology, services, markets and value creation opportunities (e.g. transactive energy, two-way grid communications, machine learning, and increased use of renewable and distributed energy resources). But as larger data sets are being exchanged at faster speeds between an increasing number of OT systems, it becomes more difficult to protect the security of the data lifecycle and the physical equipment it interacts with. These challenges are especially difficult to overcome because the economic and environmental gain (interoperability, big data, social networks and ubiquitous information sharing) are driving these prominent trends in the digital age. Often cybersecurity is an afterthought. The U.S. Department of Energy’s (DOE) Federal Energy Management Program (FEMP) funded the Pacific Northwest National Laboratory (PNNL) to develop various cybersecurity tools, trainings, and reports to aid federal facility managers – and other building owners and operators – in better applying frameworks and lessons learned from the National Institute of Standards and Technology (NIST) Cybersecurity Framework (CSF), risk management framework (RMF), DOE’s cybersecurity capability maturity model (C2M2), and a wide variety of industry best practices and guidance documents (i.e., NIST 800 series, Department of Defense United Facilities Criteria). This set of tools, collectively known as the FEMP Facility-Related Control System Cyber Toolkit (FRCS Cyber Toolkit)2, is focused on cybersecurity concerns from facility-related control systems and other operational technology (OT), such as industrial control systems (ICS). The FRCS Cyber Toolkit can be applied across six of the sixteen critical infrastructure sectors designated by the Department of Homeland Security, including government facilities, healthcare and public health, commercial facilities (e.g., public assembly, offices, lodging), financial services (e.g., banking and insurance), emergency services (e.g., fire and police stations), and information technology. With increasingly converged IT and OT systems, it is crucial to address OT cybersecurity considerations and assess how the seam of these two systems could impact the overall cybersecurity posture of a facility. The objective of this report is to provide an overview of the best possible method to use FRCS Cyber Toolkit (section 2.0) and distilled cybersecurity best practices for the federal facilities to address growing non-linear cyber threats (section 3.0). Recommendations in this document are aggregated from several NIST and other documents (see Appendix A for additional details).

97 MATHEMATICS AND COMPUTING↗

Post-Fire Safe Shutdown Capability. An Inspector's Handbook. Draft Report

The Nuclear Regulatory Commission's (NRC) current fire protection regulatory framework was initiated in response to a cable fire that occurred at the Browns Ferry Nuclear Power Station in 1975. Following the issuance of several guidance documents, in 1981 the Commission codified deterministic requirements to provide reasonable assurance that fire would not jeopardize reactor safety (10 CFR 50.48 "Fire Protection" and Appendix R to 10 CFR 50). Since then, the results of plant operating experience, NRC inspection activities and cable fire testing programs have served to clarify the application of these requirements. In 2004, the NRC amended 10 CFR Part 50.48 to add a new subsection, 10 CFR 50.48(c), that endorses, with exceptions, the National Fire Protection Association's 805, "Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants — 2001 Edition," as a voluntary alternative for demonstrating compliance with Appendix R. To date, approximately half of all operating plants have transitioned to a risk-informed approach under 10 CFR 50.48(c). Regardless of the selected approach, each operating nuclear power plant should establish a comprehensive fire protection program that includes features needed to minimize the likelihood and consequence of firesl. To achieve this objective, fire protection programs integrate the NRC's long-held safety concept of defense-in-depth (DID) by providing multiple barriers against potentially unacceptable consequences of fire. To minimize the frequency and size of fires, the first lines of defense include controls for fire prevention, such as controlling combustibles and ignition sources and fire mitigation features, such as fire detection and suppression systems. In the unlikely event that a fire should start and continue to grow in spite of these features, appropriate fire protection features, such as fire-rated barriers are provided as necessary to ensure the accomplishment of essential shutdown functions. This handbook was specifically developed for NRC inspectors that may be assigned to perform elements of Inspection Procedure (IP) 71111.05T, "Fire Protection (Triennial)," including, (a) "Protection of Safe Shutdown Capabilities," (e) "Alternative Shutdown Capability," and (f) "Circuit Analyses." Thus, the document concentrates solely on the final element of defense-in-depth— ensuring reactor safety will not be compromised in the event of a serious fire. In addition to describing how the NRC's regulatory framework has evolved since the Browns Ferry Fire, the handbook illustrates the content and scope of various analyses typically referenced in a plant's fire protection licensing basis and includes techniques and insights for assessing the plant's conformance to those criteria.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NETL CO2U openLCA LCI Database Version 2.1

The NETL CO2U openLCA LCI Database Version 2 is part of the NETL CO2U LCA Guidance Toolkit for Carbon Utilization funding recipients to meet their LCA requirements. The toolkit includes the following files: NETL CO2U LCA Guidance Document, NETL CO2U openLCA LCI Database, NETL CO2U openLCA Results Contribution Tool, NETL CO2U LCA Documentation Spreadsheet, and NETL CO2U LCA Report Template. The NETL CO2U openLCA LCI Database is an openLCA software files that contains data and an example system for funding recipients using openLCA to complete their LCA requirements.

54 ENVIRONMENTAL SCIENCES↗

NETL CO2U LCA Guidance Toolkit - Version 2.1

The NETL CO2U LCA Guidance Toolkit is part of the NETL CO2U LCA Guidance Toolkit for Carbon Utilization funding recipients to meet their LCA requirements. The toolkit includes the following files: NETL CO2U LCA Guidance Document, NETL CO2U openLCA LCI Database, NETL CO2U openLCA Results Contribution Tool, NETL CO2U LCA Documentation Spreadsheet, and NETL CO2U LCA Report Template. Note: This zip file may take a few minutes to download.

54 ENVIRONMENTAL SCIENCES↗

Ageing Management for Extended Long-Term Dry Storage of Spent Nuclear Fuel and Transportation

The principal objectives of the Coordinated Research Project (CRP) and CRADA were to (1) investigate how ageing effects leading to degradation of materials used in the spent fuel dry storage systems could be managed by ageing management programs (AMPs) and (2) using existing AMPs as a basis, establish guidance on how to develop, generate, and maintain AMPs for dry storage systems of spent nuclear fuel (SNF) that can be accomplished in various ways. The PI (Dr. Liu) is an internationally recognized expert on ageing management for license renewal of nuclear power plants and independent spent fuel dry storage installations. Dr. Liu was invited by IAEA to participate in this CRP and served as Chair of the Working Group, supporting the IAEA CRP Lead, with other members from Argentina, the Czech Republic, France, Germany, Hungary, Japan, Pakistan, Spain, Switzerland, United Kingdom, and the United States of America. Argonne’s scope of work in the CRADA for the CRP included (1) ageing management guidance documents developed by Argonne for DOE and used by the Nuclear Regulatory Commission (NRC) and industry and (2) research leveraged from the DOE Office of Nuclear Energy on the mechanical properties of high-burnup fuel cladding and the ARG-US remote monitoring systems technology developed for the DOE Packaging Certification Program, Office of Packaging and Transportation, Office of Environmental Management.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Managing changes in peak demand from building and transportation electrification with energy efficiency [Slides]

The Department of Energy funded Berkeley Lab to provide technical assistance to two municipal utilities on how energy efficiency and demand flexibility can mitigate the peak demand impacts of building and transportation electrification. Berkeley Lab worked with these utilities, Sacramento Municipal Utility District (SMUD) and Fort Collins Utilities, to identify research questions that supported their planning needs. For both utilities, Berkeley Lab developed scenario-based load forecasts that considered baseline and high-efficiency building electrification. For SMUD, the forecast also explored the sensitivity of peak demand to extreme weather (a winter cold snap) at the system-level. For Fort Collins Utilities, the forecast addressed the impacts of low, medium, and high levels of building and transportation technology adoption on select distribution feeders. Berkeley Lab is also developing a guidance document for utilities that will draw on lessons learned from the technical assistance and provide a framework for conducting similar analyses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing Consensus Recommendations to Address Challenges with Solar and Solar-Plus-Storage Code Enforcement and Permitting Approvals

The Sustainable Energy Action Committee (SEAC) provides a national platform for collaboration between key stakeholders in code enforcement and permitting for solar and solar-plus-storage projects. The outcomes from SEAC include code and standard proposals, guidance documents, information bulletins and stakeholder education. With this work, permitting and inspection of solar and solar+storage systems uses best practices, enhances safety, and becomes more efficient reducing costs for both jurisdictions and installers.

14 SOLAR ENERGY↗

29 th International Training Course on the Physical Protection of Nuclear Materials and Nuclear Facilities (Project Summary)

Sandia National Laboratories (Sandia) has hosted the International Training Course on the Physical Protection of Nuclear Materials and Nuclear Facilities since 1978. This course is the flagship training course of the International Atomic Energy Agency (IAEA). On behalf of the National Nuclear Security Administration (NNSA), Sandia manages, develops, and coordinates all course materials, and works closely with the IAEA to arrange all logistical details for the course ITC-29 incorporated some updates to the facility models, based on feedback received in ITC-28 and the ITC-29 dry run. In addition, all the graphics were refreshed after ITC-28 and implemented in the posters, data handbooks, etc. As in ITC-28, the ITC-29 staff worked closely with the IAEA on course materials, including a peer review process to ensure all course materials were aligned with Nuclear Security Series No. 13 and other relevant international guidance documentation from the IAEA. Due to the COVID-19 pandemic, ITC-29 was postponed twice and eventually took place in the late summer/early fall of 2022. Due to ongoing COVID-19 restrictions and safety requirements, the number of participants was reduced by about 31 percent from 59 participants in ITC-28 to 41 in ITC-29. As a result, the number of subgroups also decreased from eight in ITC-28 to six for ITC-29. This enabled the Sandia team to implement more opportunities for social distancing, particularly in the large classrooms. Despite the challenges, ITC-29 still passed a significant milestone, with the one-thousandth participant of the international training course attending during this event. Finally, the ITC staff continued the use of its improved method of evaluation to capture participants’ satisfaction with the updated course and to gather feedback concerning future improvements. This document provides a brief description of ITC-29, including a summary of lessons learned and key recommendations for future development efforts.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗