Formulation and Characterization of Epoxy Resin Copolymer for Graphite Composites

Maximum char yield was obtained with a copolymer containing 25% mol fraction DGEBE and 75% mol fraction DGEBA (Epon 828). To achieve the high values (above 40%), a large quantity of catalyst (trimethoxyboroxine) was necessary. Although a graphite laminate 1/8" thick was successfully fabricated, the limited life of the catalyzed epoxy copolymer system precludes commercial application. Char yields of 45% can be achieved with phenolic cured epoxy systems as indicated by data generated under NAS2-10207 contract. A graphite laminate using this type of resin system was fabricated for comparison purposes. The resultant laminate was easier to process and because the graphite prepreg is more stable, the fabrication process could readily be adapted to commercial applications.

Keck, F. L.↗

Surface analysis of graphite fiber reinforced polyimide composites

Several techniques have been used to establish the effect of different surface pretreatments on graphite-polyimide composites. Composites were prepared from Celion 6000 graphite fibers and the polyimide LARC-160. Pretreatments included mechanical abrasion, chemical etching and light irradiation. Scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) were used in the analysis. Contact angle of five different liquids of varying surface tensions were measured on the composites. SEM results showed polymer-rich peaks and polymer-poor valleys conforming to the pattern of the release cloth used durng fabrication. Mechanically treated and light irradiated samples showed varying degrees of polymer peak removal, with some degradation down to the graphite fibers. Minimal changes in surface topography were observed on concentrations of surface fluorine even after pretreatment. The light irradiation pretreatment was most effective at reducing surface fluorine concentrations whereas chemical pretreatment was the least effective. Critical surface tensions correlated directly with the surface fluorine to carbon ratios as calculated from XPS.

Messick, D. L.↗

Effect of substrate chemical pretreatment on the tribological properties of graphite films

Rubbed films of natural flake Madagascar graphite were applied to ASTM A-355(D) steel with chemical surface pretreatments of zinc phosphate, gas nitride, salt nitride, sulfo-nitride, and with mechanical pretreatment (sandblasting). SAE 1045 steel pins were slid against these films using a pin-on-disk tribometer. The results indicate that two different lubricating mechanisms can occur. In the chemical surface pretreatment, the graphite can mix together to form a surface layer of the two constituents and this plasticity flowing layer provides the lubrication. The longest endurance lives and the lowest pin wear rates were obtained with this mechanism. In the other, surface topography appeared to control the mechanism. A rough surface was necessary to serve as a reservoir to supply the graphite to the flat metallic plateaus where it was sheared in very thin films between the plateaus and the sliding pin surface. For this mechanism, chemical pretreatment seemed to do little more than serve as a means for roughening the surface. Mean friction was not significantly influenced by chemical pretreatment, but surface roughness effects were observed.

Fusaro, R. L.↗

Dynamics of graphite fiber intercalation: In situ resistivity measurements with a four point probe

The dynamics of ferric chloride intercalation of single graphite fibers were studied, in situ, using a four point dc bridge. Measurements before, during and after the intercalation showed that the intercalation occurred within minutes at 200 C. Changes in fiber resistivity after exposure to air suggested hydration of the graphite intercalation compound. Deintercalation of the ferric chloride was initiated at temperatures in excess of 400 C. cycling the intercalant into and out of the graphite fiber gave no improvements in fiber resistivity. The activation energy of the ferric chloride intercalation reaction was found to be 17 + or - 4 kcal/mol 1 consistent with the concept of a preliminary nucleation step in the intercalation reaction.

Jaworske, D. A.↗

A micrographic and gravimetric study of intercalation and deintercalation of graphite fibers

Intercalation and deintercalation of Union Carbide P-100 graphite fibers with liquid and vaporous bromine was studied gravimetrically and microscopically. The mass of the bromine intercalated fibers was found to be 17 to 20 percent greater than their pristine counterpart. This variation decreased to 17 to 18 percent after heating in air for 3 days at 200 C and to 14.5 to 18 percent after 6 days of 260 C heating. The fiber length did not change throughout the experiment. The fiber diameter increased during intercalation and decreased slightly upon deintercalation but was not affected by heating to 260 C for 3 days in air. Comparing the mass and volume data to those with highly oriented pyrolitic graphite or natural single crystal graphite suggested the possibility that the intercalated P-100 fibers could be mostly stage 4.

Hung, C. C.↗

The effects of space radiation on a chemically modified graphite-epoxy composite material

The effects of the space environment on the engineering properties and chemistry of a chemically modified T300/934 graphite-epoxy composite system are characterized. The material was subjected to 1.0 x 10 to the 10th power rads of 1.0 MeV electron irradiation under vacuum to simulate 30 years in geosynchronous earth orbit. Monotonic tension tests were performed at room temperature (75 F/24 C) and elevated temperature (250 F/121 C) on 4-ply unidirectional laminates. From these tests, inplane engineering and strength properties (E sub 1, E sub 2, Nu sub 12, G sub 12, X sub T, Y sub T) were determined. Cyclic tests were also performed to characterize energy dissipation changes due to irradiation and elevated temperature. Large diameter graphite fibers were tested to determine the effects of radiation on their stiffness and strength. No significant changes were observed. Dynamic-mechanical analysis demonstrated that the glass transition temperature was reduced by 50 F(28 C) after irradiation. Thermomechanical analysis showed the occurrence of volatile products generated upon heating of the irradiated material. The chemical modification of the epoxy did not aid in producing a material which was more radiation resistant than the standard T300/934 graphite-epoxy system. Irradiation was found to cause crosslinking and chain scission in the polymer. The latter produced low molecular weight products which plasticize the material at elevated temperatures and cause apparent material stiffening at low stresses at room temperature.

Reed, S. M.↗

Detection of fiber damage in a graphite epoxy composite using current injection and magnetic field mapping

A novel NDE technique is reported for detecting fiber disruptions in graphite-epoxy composites. The technique involves injecting electric current along the graphite fibers of a composite and measuring the resulting magnetic fields. The disruptions in current paths, which occur in areas of fiber damage, are detectable as perturbations in the magnetic field. The experimental setup, the measurements, and the magnetic images of experimental samples are presented. A resistive model has been developed to be used in the modeling of two-dimensional conductivity patterns in graphite composites. Diagrams of the setup and the circuitry are included.

Blalock, T. N.↗

Effects of milling brominated P-100 graphite fibers

Preliminary procedures have been developed for the ball milling of pristine and brominated P-100 graphite fibers. Because of the lubricative properties of graphite, large ball loads (50 percent by volume) are required. Use of 2-propanol as a milling medium enhances the efficiency of the process. The fibers, when allowed to settle from the milling medium, tend to be preferentially aligned with rather few fibers standing up. Milled, brominated P-100 fibers have resistivities that are indistinguishable from their pristine counterparts, apparently because of loss of bromine. This suggests that bromine would not be the intercalate of choice in applications where milled fibers of this type are required. It was found that brominated graphite fibers are stable in a wide variety of organic solvents.

Gaier, James R.↗

Thermal and flammability characterization of graphite composites

Thermal, mechanical, and flammability properties of graphite composites fabricated with XU71775/H795, a bismaleimide/vinyl-polystyrylpyridine formulation; H795, a bismaleimide; Cycom 6162, a phenolic; and PSP 6022M, a polystyrylpyridine and two types of graphite reinforcement were evaluated and compared with a composite made with an epoxy resin as a matrix. The measured properties included limiting-oxygen index, smoke evolution, thermal degradation products, total-heat release, heat-release rates, mass loss, flame spread, ignition resistance, thermogravimetric analysis, and selected mechanical properties. It was found that the combination of XU71775/H795 with the graphite tape was the optimum design giving the lowest heat release rate.

Kourtides, D. A.↗

Adhesion at the interface in cured graphite fiber epoxy-amine resin composites

The effect of high temperature curing on the interface between unsized or epoxy-sized graphite fiber tow and epoxy-amine resin was examined by scanning electron microscopy of compression and freeze fractured specimens. Little or no adhesion was found between the unsized graphite fiber tows and the epoxy-amine resin on curing at 165 C for 17 hrs. Epoxy-sized graphite fibers showed a similar lack of adhesion between the fiber tows and the epoxy-amine resin at 3 and 17 hr cures, although good penetration of the resin into the sized fiber tows had occurred. Interfacial bond strengths for the composites could not be effectively measured by compression fracture of specimens.

Needles, Howard L.↗

Graphite Fluoride Fiber Composites For Heat Sinking

Graphite fluoride fiber/polymer composite materials consist of graphite fluoride fibers in epoxy, polytetrafluoroethylene, or polyimide resin. Combines high electrical resistivity with high thermal conductivity and solves heat-transfer problems of many electrical systems. Commercially available in powder form, for use as dry lubricant or cathode material in lithium batteries. Produced by direct fluorination of graphite powder at temperature of 400 to 650 degree C. Applications include printed-circuit boards for high-density power electronics, insulators for magnetic-field cores like those found in alternators and transformers, substrates for thin-film resistors, and electrical-protection layers in aircraft de-icers.

Hung, Ching-Cheh↗

Design, fabrication, and performance of brazed, graphite electrode, multistage depressed collectors with 500-W, continuous wave, 4.8- to 9.6-GHz traveling-wave tubes

A small, isotropic graphite electrode, multistage depressed collector (MDC) was designed, fabricated, and evaluated in conjunction with a 500-W, continuous wave (CW), 4.8- to 9.6-GHz traveling-wave tube (TWT). The carbon electrode surfaces were used to improve the TWT overall efficiency by minimizing the secondary electron emission losses in the MDC. The design and fabrication of the brazed graphite MDC assembly are described. The brazing technique, which used copper braze filler metal, is compatible with both vacuum and the more commonly available hydrogen atmosphere brazing furnaces. The TWT and graphite electrode MCC bakeout, processing, and outgassing characteristics were evaluated and found to be comparable to TWT's equipped with copper electrode MDC's. The TWT and MDC performance was optimized for broadband CW operation at saturation. The average radiofrequency (RF), overall, and MDC efficiencies were 14.9, 46.4, and 83.6 percent, respectively, across the octave operating band. A 1500-hr CW test, conducted without the use of an appendage ion pump, showed no gas buildup and excellent stability of the electrode surfaces.

Ramins, Peter↗

Carbon doping in molecular beam epitaxy of GaAs from a heated graphite filament

Carbon doping of GaAs grown by molecular beam epitaxy has been obtained for the first time by use of a heated graphite filament. Controlled carbon acceptor concentrations over the range of 10 to the 17th-10 to the 20th/cu cm were achieved by resistively heating a graphite filament with a direct current power supply. Capacitance-voltage, p/n junction and secondary-ion mass spectrometry measurements indicate that there is negligible diffusion of carbon during growth and with postgrowth rapid thermal annealing. Carbon was used for p-type doping in the base of Npn AlGaAs/GaAs heterojunction bipolar transistors. Current gains greater than 100 and near-ideal emitter heterojunctions were obtained in transistors with a carbon base doping of 1 x 10 to the 19th/cu cm. These preliminary results indicate that carbon doping from a solid graphite source may be an attractive substitute for beryllium, which is known to have a relatively high diffusion coefficient in GaAs.

Malik, R. J.↗

Isotropic graphite multistage depressed collectors - A progress report

A small isotropic-graphite-electrode multistage depressed collector (MDC) was designed, fabricated, and evaluated in conjunction with a 500-W CW 4.8-9.6-GHz TWT. The carbon electrode surfaces were used to improve the TWT overall efficiency by minimizing the secondary-electron emission losses in the MDC. The design and fabrication of the brazed graphite MDC assembly are described. The TWT and graphite-electrode MDC bakeout and processing (outgassing) characteristics were evaluated and found to be comparable to those for TWTs equipped with copper-electrode MDCs. The TWT and MDC performance was optimized for broadband CW operation at saturation. The average RF, overall, and MDC efficiencies were 14.9, 46.4, and 83.6 percent, respectively, across the octave operating band. A 1500-h CW test showed no gas buildup and excellent stability of the electrode surfaces.

Ramins, Peter↗

Density of intercalated graphite fibers

The density of Amoco P-55, P-75, P-100, and P-120 pitch-based graphite fibers and their intercalation compounds with bromine, iodine monochloride, and copper (II) chloride have been measured using a density gradient column. The distribution of densities within a fiber type is found to be a sensitive indicator of the quality of the intercalation reaction. In all cases the density was found to increase, indicating that the mass added to the graphite is dominant over fiber expansion. Density increases are small (less than 10 percent) giving credence to a model of the intercalated graphite fibers which have regions which are intercalated and regions which are not.

Gaier, James R.↗

Damage tolerance of woven graphite-epoxy buffer strip panels

Graphite-epoxy panels with S glass buffer strips were tested in tension and shear to measure their residual strengths with crack-like damage. The buffer strips were regularly spaced narrow strips of continuous S glass. Panels were made with a uniweave graphite cloth where the S glass buffer material was woven directly into the cloth. Panels were made with different width and thickness buffer strips. The panels were loaded to failure while remote strain, strain at the end of the slit, and crack opening displacement were monitoring. The notched region and nearby buffer strips were radiographed periodically to reveal crack growth and damage. Except for panels with short slits, the buffer strips arrested the propagating crack. The strength (or failing strain) of the panels was significantly higher than the strength of all-graphite panels with the same length slit. Panels with wide, thick buffer strips were stronger than panels with thin, narrow buffer strips. A shear-lag model predicted the failing strength of tension panels with wide buffer strips accurately, but over-estimated the strength of the shear panels and the tension panels with narrow buffer strips.

Kennedy, John M.↗

Measurements of print-through in graphite fiber epoxy composites

High-reflectance accurate-contour mirrors are needed for solar dynamic space power systems. Graphite fiber epoxy composites are attractive candidates for such applications owing to their high modulus, near-zero coefficient of thermal expansion, and low mass. However, mirrors prepared from graphite fiber epoxy composite substrates often exhibit print-through, a distortion of the surface, which causes a loss in solar specular reflectance. Efforts to develop mirror substrates without print-through distortion require a means of quantifying print-through. Methods have been developed to quantify the degree of print-through in graphite fiber epoxy composite specimens using surface profilometry.

Jaworske, Donald A.↗

Density of intercalated graphite fibers

The density of Amoco P-55, P-75, P-100, and P-120 pitch-based graphite fibers and their intercalation compounds with bromine, iodine monochloride, and copper (II) chloride have been measured using a density gradient column. The distribution of densities within a fiber type is found to be a sensitive indicator of the quality of the intercalation reaction. In all cases the density was found to increase, indicating that the mass added to the graphite is dominant over fiber expansion. Density increases are small (less than 10 percent) giving credence to a model of the intercalated graphite fibers which have regions which are intercalated and regions which are not.

Gaier, James R.↗