Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas detector electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Using cyclotron radiation emission for ultra-high resolution x-ray spectroscopy

Abstract Cyclotron radiation emission spectroscopy (CRES) is an approach to measuring the energy of an electron trapped in an externally applied magnetic field. The bare electron can come from different interactions, including photoelectric absorption, Compton scatters, beta decay, and pair production. CRES relies on measuring the frequency of the electron’s cyclotron motion, and because the measurement times extend over 10 6 –10 7 cycles, the energy resolution is on the order of a single electronvolt. To date, CRES has only been performed on internal beta-emitting radioisotopes, but the technology can be applied to x-ray spectrometery through appropriate selection of a target gas and sufficient intensity of the distinct x-ray source. The applications of this technology range from high-precision measurements of atomic energy levels to calibrations of basic science experiments, to trace element identification. In this work we explore the use of CRES for x-ray spectroscopy within the rubric of measuring the energy levels of argon. Though the energy levels of argon are well established, we adopt this motivation as an example question around which a detector may be designed. The issues we explore include target material, density, electron trapping depth, noise levels, and overall efficiency. We also discuss spectral deconvolution and how the multiple peaks obtained from a single target/source pair can be used to enhance the robustness of the measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Performance of photosensors in a high-rate environment for gas Cherenkov detectors

We report the solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to the high luminosity, the single-photon background rate in this counter can exceed 160 kHz/cm 2 at the photosensors. Therefore, it is essential to validate the high-rate limits of the planned photosensors and readout electronics in order to mitigate the risk of failure. We report on the design and an early set of studies carried out using a small Cherenkov counter in a high-rate environment up to 60 kHz/cm 2 , in Hall C at Jefferson Lab. Commercially available multi-anode photomultipliers (MaPMT) and low-cost large-area picosecond photodetectors (LAPPD) were tested using the JLab FADC250 modules for readout. The test beam results show that the MaPMT array and the internal stripline LAPPD can detect and identify single-electron and pair-production events in high-rate environments. Due to its higher quantum efficiency, the MaPMT array provided a better separation between the single-electron and the pair-production events compared to the internal stripline LAPPD. A GEANT4 simulation confirms the beam test performance of our counter device.

47 OTHER INSTRUMENTATION↗

Review of the High Performance Antiproton Trap (HiPAT) Experiment at the Marshall Space Flight Center

The significant energy density of matter-antimatter annihilation is attractive to the designers of future space propulsion systems, with the potential to offer a highly compact source of power. Many propulsion concepts exist that could take advantage of matter-antimatter reactions, and current antiproton production rates are sufficient to support basic proof-of-principle evaluation of technology associated with antimatter- derived propulsion. One enabling technology for such experiments is portable storage of low energy antiprotons, allowing antiprotons to be trapped, stored, and transported for use at an experimental facility. To address this need, the Marshall Space Flight Center's Propulsion Research Center is developing a storage system referred to as the High Performance Antiproton Trap (HiPAT) with a design goal of containing 10(exp 12) particles for up to 18 days. The HiPAT makes use of an electromagnetic system (Penning- Malmberg design) consisting of a 4 Telsa superconductor, high voltage electrode structure, radio frequency (RF) network, and ultra high vacuum system. To evaluate the system normal matter sources (both electron guns and ion sources) are used to generate charged particles. The electron beams ionize gas within the trapping region producing ions in situ, whereas the ion sources produce the particles external to the trapping region and required dynamic capture. A wide range of experiments has been performed examining factors such as ion storage lifetimes, effect of RF energy on storage lifetime, and ability to routinely perform dynamic ion capture. Current efforts have been focused on improving the FW rotating wall system to permit longer storage times and non-destructive diagnostics of stored ions. Typical particle detection is performed by extracting trapped ions from HiPAT and destructively colliding them with a micro-channel plate detector (providing number and energy information). This improved RF system has been used to detect various plasma modes for both electron and ion plasmas in the two traps at MSFC, including axial, cyclotron, and diocotron modes. New diagnostics are also being added to HiPAT to measure the axial density distribution of the trapped cloud to match measured RF plasma modes to plasma conditions.

Pearson, J. B.↗

Laboratory studies of sticking coefficients and heterogeneous reactions important in the Antarctic stratosphere

Laboratory studies of sticking coefficients of H2O, HCl, Cl2, and HNO3 on ice and heterogeneous reactions of ClONO2 with ice or HCl/ice have been performed in a fast flow reactor. A quadrupole mass spectrometer with electron impact ionization was used as a detector. Measured sticking coefficients are: 0.3 (+0.7, -0.1) for H2O, 0.4 (+0.6, -0.2) for HCL, less than 0.0001 for Cl2, and 0.3 (+0.7, -0.1) for HNO3 at 200 K. The reaction probability of ClONO2 on ice was found to be 0.06 (+ or - 0.03) while HOCl was observed as a sole product in the gas phase. With HCl present in ice, the reaction probability of ClONO2 is greatly enhanced, approaching 0.27 (+0.73, -0.13) while molecular chlorine was found to be the major product in the gas phase. Another reaction product was nitric acid which remained in the solid phase. Since the polar stratospheric clouds contain ice particles or possibly HCl/ice particles on the surface, the present results should be a major factor in producing the observed springtime ozone depletion in the Antarctic stratosphere.

Leu, Ming-Taun↗

Zinc Alloys for the Fabrication of Semiconductor Devices

ZnBeO and ZnCdSeO alloys have been disclosed as materials for the improvement in performance, function, and capability of semiconductor devices. The alloys can be used alone or in combination to form active photonic layers that can emit over a range of wavelength values. Materials with both larger and smaller band gaps would allow for the fabrication of semiconductor heterostructures that have increased function in the ultraviolet (UV) region of the spectrum. ZnO is a wide band-gap material possessing good radiation-resistance properties. It is desirable to modify the energy band gap of ZnO to smaller values than that for ZnO and to larger values than that for ZnO for use in semiconductor devices. A material with band gap energy larger than that of ZnO would allow for the emission at shorter wavelengths for LED (light emitting diode) and LD (laser diode) devices, while a material with band gap energy smaller than that of ZnO would allow for emission at longer wavelengths for LED and LD devices. The amount of Be in the ZnBeO alloy system can be varied to increase the energy bandgap of ZnO to values larger than that of ZnO. The amount of Cd and Se in the ZnCdSeO alloy system can be varied to decrease the energy band gap of ZnO to values smaller than that of ZnO. Each alloy formed can be undoped or can be p-type doped using selected dopant elements, or can be n-type doped using selected dopant elements. The layers and structures formed with both the ZnBeO and ZnCdSeO semiconductor alloys - including undoped, p-type-doped, and n-type-doped types - can be used for fabricating photonic and electronic semiconductor devices for use in photonic and electronic applications. These devices can be used in LEDs, LDs, FETs (field effect transistors), PN junctions, PIN junctions, Schottky barrier diodes, UV detectors and transmitters, and transistors and transparent transistors. They also can be used in applications for lightemitting display, backlighting for displays, UV and visible transmitters and detectors, high-frequency radar, biomedical imaging, chemical compound identification, molecular identification and structure, gas sensors, imaging systems, and for the fundamental studies of atoms, molecules, gases, vapors, and solids.

Ryu, Yungryel↗

Design Improvements and X-Ray Performance of a Time Projection Chamber Polarimeter for Persistent Astronomical Sources

The design of the Time-Projection Chamber (TPC) Polarimeter for the Gravity and Extreme Magnetism Small Explorer (GEMS) was demonstrated to Technology Readiness Level 6 (TRL-6)3 and the flight detectors fabricated, assembled and performance tested. A single flight detector was characterized at the Brookhaven National Laboratory Synchrotron Light Source with polarized X-rays at 10 energies from 2.3-8.0 keV at five detector positions. The detector met all of the GEMS performance requirements. Lifetime measurements have shown that the existing flight design has 23 years of lifetime4, opening up the possibility of relaxing material requirements, in particular the consideration of the use of epoxy, to reduce risk elsewhere. We report on design improvements to the GEMS detector to enable a narrower transfer gap that, when operated with a lower transfer field, reduces asymmetries in the detector response. In addition, the new design reduces cost and risk by simplifying the assembly and reducing production time. Finally, we report on the performance of the narrow-gap detector in response to polarized and unpolarized X-rays.

GEMS↗

Ion Storage with the High Performance Antiproton Trap (HiPAT)

The matter antimatter reaction represents the densest form of energy storage/release known to modern physics: as such it offers one of the most compact sources of power for future deep space exploration. To take the first steps along this path, NASA-Marshall Space Flight Center is developing a storage system referred to as the High Performance Antiproton Trap (HiPAT) with a goal of maintaining 10(exp 12) particles for up to 18 days. Experiments have been performed with this hardware using normal matter (positive hydrogen ions) to assess the device's ability to hold charged particles. These ions are currently created using an electron gun method to ionize background gas; however, this technique is limited by the quantity that can be captured. To circumvent this issue, an ion source is currently being commissioned which will greatly increase the number of ions captured and more closely simulate actual operations expected at an antiproton production facility. Ions have been produced, stored for various time intervals, and then extracted against detectors to measure species, quantity and energy. Radio frequency stabilization has been tested as a method to prolong ion lifetime: results show an increase in the baseline 1/e lifetime of trapped particles from hours to days. Impurities in the residual background gas (typically carbon-containing species CH4, CO, CO2, etc.) present a continuing problem by reducing the trapped hydrogen population through the mechanism of ion charge exchange.

Martin, James↗

Detector Assembly and the Ultralow-Temperature Refrigerator for XRS

The X-ray spectrometer (XRS) on the Japanese Astro-E Spacecraft is the first ultra low temperature space borne instrument. The system utilizes a 900g Ferric Ammonium Alum (FAA) Adiabatic Demagnetization Refrigerator (ADR) with a helium-3 gas gap heat switch to cool the detector assembly to 0.060K. The system operates in a "single shot" configuration allowing the system to remain at its operating temperature for about 40 hours in the lab. The on-orbit performance is expected to be about 35 hours with a 97% duty cycle. The detector assembly for XRS consists of a 32 channel microcalorimeter array bias electronics, thermometry, and an anti-coincidence detector that are attached to the cold stage of the ADR. To thermally Isolate the detector system from the superfluid helium reservoir, the detector system is suspended by Kevlar cords and electrical connection in made by L30, 17-micron diameter, tensioned NbTi leads. The detectors are read out in a source-follower arrangement using FET amplifiers operating at 130K mounted in multiply-thermally-isolated assemblies that also use Kevlar and stainless steel wiring. The design and thermal performance of this system will be discussed and compared to the theoretical limits.

Porter, F. S.↗

A rare gas optics-free absolute photon flux and energy analyzer to provide absolute photoionization rates of inflowing interstellar neutrals

A prototype spectrometer has been developed for space applications requiring long term absolute EUV photon flux measurements. The energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer, followed by an electron multiplier detector, pulses due to individual electrons are counted. The overall efficiency of this process can be made essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided. A very important feature of this approach is its freedom from the problem of overlapping spectral orders that plagues grating EUV spectrometers. An instrument with these features has not been flown before, but is essential to further advances in our understanding of solar EUV flux dynamics, and the coupled dynamics of terrestrial and planetary atmospheres. The detailed characteristics of this optics-free spectrometer are presented in the publications section.

Judge, Darrell L.↗

A rare gas optics-free absolute photon flux and energy analyzer for solar and planetary observations

We have developed a prototype spectrometer for space applications requiring long term absolute EUV photon flux measurements. In this recently developed spectrometer, the energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer, followed by an electron multiplier detector, pulses due to individual electrons are counted. The overall efficiency of this process can be made essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided. A very important feature of this approach is its freedom from the problem of overlapping spectral orders that plagues grating EUV spectrometers. An instrument with these features has not been flown before, but is essential to further advances in our understanding of solar EUV flux dynamics, and the coupled dynamics of terrestrial and planetary atmospheres. The detailed characteristics of this optics-free spectrometer are presented in the publications section.

Judge, Darrell L.↗

Injection, confinement, and diagnosis of electrons and positrons in a permanent magnet dipole trap

Abstract Prerequisites for the goal of studying long-lived, magnetically confined, electron–positron pair plasmas in the laboratory include the injection of both species into the trap, long trapping times, and suitable diagnostic methods. Here we report recent progress on these tasks achieved in a simple dipole trap based on a supported permanent magnet. For the injection of electrons, both an $$\textbf{E}\times B$$ E × B drift technique (of a $$\sim $$ ∼ 2– $$\upmu $$ μ A, 6-eV beam) and “edge injection” (from a filament emitting a few mA and biased to some tens of volts) have been demonstrated; the former is suitable for low-density beams with smaller spatial and velocity spreads, while the latter employs fluctuations arising from collective behavior. To diagnose the edge-injected electrons, image potentials and currents induced on a wall probe, the magnet case, and wall electrodes were measured. Confinement of drift-injected positrons, measured experimentally, exhibited at least two well-separated timescales. Simulations reproduced this qualitatively, using a simple model of elastic collisions with residual background gas, and point to small adjustments for increasing trapping times. In a major upgrade to diagnostic capabilities, 25 bismuth germanate detectors, placed in three reentrant ports, are able to localize annihilation gammas, which will be used in future experiments to distinguish between different loss channels. Graphical abstract

von der Linden, J. (ORCID:0000000327477813)↗

A rare gas optics-free absolute EUV photon spectrometer for solar system studies

We have developed a prototype spectrometer for space applications which require long term absolute EUV photon flux measurements. In this recently developed spectrometer, the energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer operating at a few eV, and followed by an electron multiplying detector, pulses due to individual electrons are counted. The overall efficiency of this process is essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided.

Daybell, M. D.↗

NDX: Neutron Dose Rate Meters with Extended Capabilities

Particle accelerators, irradiation facilities, and nuclear power plants would benefit from using neutron dose rate meters featuring improved energy response covering full range of expected neutron energies, improved dynamic range of measured dose rates while providing the real-time data, and improved ability to operate in harsh radiation environments including heavy photon backgrounds and pulsed beams. The novel design of the neutron moderator for the NDX dose rate meter implements a layer of a Beryllium-loaded medium Z material which, similar to the earlier known WENDI detectors, allows the device to detect higher energy neutron flux and convert it to dose. Using Beryllium helps to fill the known dip in the response functions around 5-50 MeV. Optimized design parameter set, obtained using FLUKA Monte Carlo simulations, features the NDX moderator made of polyethylene embedding a layer of BeCu alloy inside, with the dose rate response constant within ±10% in the neutron energy range from about 100 keV to 500 MeV, and ±25% essentially in the full energy range above thermal. A new sensor technique implemented in the NDX is based on using the Ionization Chamber (IC) filled with 3He gas to capture the moderated neutron fluence, and includes a symmetric IC filled with regular 4He to evaluate the contributions due to the non-neutron ionizing radiation. Advantages of the method include large accessible dynamic range, relative insensitivity of the IC probes to photon radiation fields, and the ability to subtract their contribution. Two prototype NDX detectors were built, calibrated, and operated in various conditions at the CEBAF 12 GeV electron accelerator at JLab. The first results showed reliable neutron dose rate measurements in the presence of overwhelming photon radiation fields, and at practical high dose rate levels of up to approximately 10 Sv/h. Detector design, operation, first results, and further development plans are presented.

Degtiarenko, Pavel V.↗

Moisture content and gas sampling device

An apparatus is described for measuring minute quantities of moisture and other contaminants within sealed enclosures such as electronic assemblies which may be subject to large external atmospheric pressure variations. An array of vacuum quality valves is arranged to permit cleansing of the test apparatus of residual atmospheric components from a vacuum source. This purging operation evacuates a gas sample bottle, which is then connected by valve settings to provide the drive for withdrawing a gas sample from the sealed enclosure under test into the sample bottle through a colometric detector tube (Drager tube) which indicates moisture content. The sample bottle may be disconnected and its contents (drawn from the test enclosure) separately subjected to mass spectrograph analysis.

Krieg, H. C., Jr.↗

Energy resolution and gain measurements in Argon-based gas mixtures: Exploring Ar:CF 4 for low energy measurements with TPCs

Time Projection Chambers (TPCs) are among the most advanced charged-particle detectors. Gas-filled TPCs have tracking capabilities that provide 3D-imaging of charged particles with a good energy resolution for spectroscopy. Different gas mixtures have different properties that determine the energy resolution as well as the spatial resolution. Therefore, optimization of operating conditions is required to simultaneously obtain adequate gain, energy resolution, spatial/track resolution, as well as higher drift velocities for high counting rates applications. Ar:CF 4 gas mixture has higher electron drift velocities and lower electron diffusion, which makes it an attractive candidate for TPC filling gas for low energy nuclear physics applications as compared to commonly used Ar:CH 4 and Ar:CO 2 gas mixtures, namely when tracking information is needed. However, other properties, including energy resolution and gain, remain largely unexplored in Ar:CF 4 especially at pressures and other operating conditions relevant for low-energy nuclear physics applications. Here, in this paper we report on gain and energy resolution measurements, using Gas Electron Multipliers (GEMs), in the less explored Ar:CF 4 mixture (Alfonsi et al., 2006), as well as in the more commonly used gas mixtures Ar:CH 4 and Ar:CO 2 . In addition to obtaining energy resolution and gain, we provide results from Garfield++ simulations for gain fluctuations, and their impact on energy resolution is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Verification of the Gravity and Extreme Magnetism Small Explorer GEMS X-Ray Polarimeter

olarimetry is a powerful tool for astrophysical observations that has yet to be exploited in the X-ray band. For satellite-borne and sounding rocket experiments, we have developed a photoelectric gas polarimeter to measure X-ray polarization in the 2-10 keV range utilizing a time projection chamber (TPC) and advanced micro-pattern gas electron multiplier (GEM) techniques. We carried out performance verification of a flight equivalent unit (1/4 model) which was planned to be launched on the NASA Gravity and Extreme Magnetism Small Explorer (GEMS) satellite. The test was performed at Brookhaven National Laboratory, National Synchrotron Light Source (NSLS) facility in April 2013. The polarimeter was irradiated with linearly-polarized monochromatic X-rays between 2.3 and 10.0 keV and scanned with a collimated beam at 5 different detector positions. After a systematic investigation of the detector response, a modulation factor greater than or equal to 35% above 4 keV was obtained with the expected polarization angle. At energies below 4 keV where the photoelectron track becomes short, diffusion in the region between the GEM and readout strips leaves an asymmetric photoelectron image. A correction method retrieves an expected modulation angle, and the expected modulation factor, approximately 20% at 2.7 keV. Folding the measured values of modulation through an instrument model gives sensitivity, parameterized by minimum detectable polarization (MDP), nearly identical to that assumed at the preliminary design review (PDR).

Time Projection↗

Arcus: The X-Ray Grating Spectrometer Explorer

Arcus will be proposed to the NASA Explorer program as a free-flying satellite mission that will enable high-resolution soft X-ray spectroscopy (8-50 Angstroms) with unprecedented sensitivity-effective areas of greater than 500 sq cm and spectral resolution greater than 2500. The Arcus key science goals are (1) to determine how baryons cycle in and out of galaxies by measuring the effects of structure formation imprinted upon the hot gas that is predicted to lie in extended halos around galaxies, groups, and clusters, (2) to determine how black holes influence their surroundings by tracing the propagation of out-flowing mass, energy and momentum from the vicinity of the black hole out to large scales and (3) to understand how accretion forms and evolves stars and circumstellar disks by observing hot infalling and outflowing gas in these systems. Arcus relies upon grazing incidence silicon pore X-ray optics with the same 12m focal length (achieved using an extendable optical bench) that will be used for the ESA Athena mission. The focused X-rays from these optics will then be diffracted by high-efficiency off-plane reflection gratings that have already been demonstrated on sub-orbital rocked flights, imaging the results with flight-proven CCD detectors and electronics. The power and telemetry requirements on the spacecraft are modest. The majority of mission operations will not be complex, as most observations will be long (~100 ksec), uninterrupted, and pre-planned, although there will be limited capabilities to observe targets of opportunity, such as tidal disruption events or supernovae with a 3-5 day turnaround. After the end of prime science, we plan to allow guest observations to maximize the science return of Arcus to the community.

Instrumentation↗

Complete positive ion, electron, and ram negative ion measurements near Comet Halley (COPERNIC) plasma experiment for the European Giotto Mission

Participation of U.S. scientists on the COPERNIC (COmplete Positive ions, Electrons and Ram Negative Ion measurements near Comet Halley) plasma experiment on the Giotto mission is described. The experiment consisted of two detectors: the EESA (electron electrostatic analyzer) which provided three-dimensional measurements of the distribution of electrons from 10 eV to 30 keV, and the PICCA (positive ion cluster composition analyzer) which provided mass analysis of positively charged cold cometary ions from mass 10 to 210 amu. In addition, a small 3 deg wide sector of the EESA looking in the ram direction was devoted to the detection of negatively charged cold cometary ions. Both detectors operated perfectly up to near closest approach (approx. 600 km) to Halley, but impacts of dust particles and neutral gas on the spacecraft contaminated parts of the data during the last few minutes. Although no flight hardware was fabricated in the U.S., The U.S. made very significant contributions to the hardware design, ground support equipment (GSE) design and fabrication, and flight and data reduction software required for the experiment, and also participated fully in the data reduction and analysis, and theoretical modeling and interpretation. Cometary data analysis is presented.

Lin, Robert P.↗