At least 181 records · Page 10

Frequency response of the vestibulo-ocular reflex /VOR/ in the monkey

The frequency response of the vestibulo-ocular reflex has been investigated in the alert monkey during sinusoidal rotation about a vertical axis in a frequency range of 0.001-0.5 Hz. Phase and gain of nystagmus slow phase velocity was determined. In the frequency range above 0.1 Hz, nystagmus slow phase velocity was in phase with (compensated for) head velocity. At lower frequencies, an increasing phase lead was present which could reach more than 90 deg. Gain fell off correspondingly at low frequencies. Calculated time constants were 10-40 s in different monkeys. Animals which had been exposed to numerous previous rotary stimuli in the laboratory showed much shorter time constants than did 'native' monkeys.

Buettner, U. W.↗

Pitfalls and guidelines for the numerical evaluation of moderate-order system frequency response

The design and evaluation of a feedback control system via frequency response methods relies heavily upon numerical methods. In application, one can usually develop low order simulation models which for the most part are devoid of numerical problems. However, when complex feedback interactions, for example, between instrument control systems and their flexible mounting structure, must be evaluated, simulation models become moderate to large order and numerical problems become common. A large body of relevant numerical error analysis literature is summarized in a large language understandable to nonspecialists. The intent is to provide engineers using simulation models with an engineering feel for potential numerical problems without getting intertwined in the complexities of the associated mathematical theory. Guidelines are also provided by suggesting alternate state of the art methods which have good numerical evaluation characteristics.

Frisch, H. P.↗

Frequency response of a jet engine test facility air supply system

The frequency response of a laboratory scale model of a portion of the air supply system of an engine test facility is obtained both experimentally and using one-dimensional, small-signal, distributed parameter theory. The effects of line terminations and mean flow are considered. Good agreement between experiment and theory is obtained. Predictions are extended to a full scale test facility air supply system operating under several possible test conditions.

Franke, M. E.↗

Distribution Feeder-Scale Fast Frequency Response via Optimal Coordination of Net-load Resources Part II: Large-Scale Demonstration

This work is the second of a two-part series in which we develop and experimentally demonstrate a hierarchical control solution for optimally coordinating thousands of deferrable loads and distributed energy resources (DERs) to provide fast frequency response (FFR) from an entire distribution feeder. In Part I, we developed and proved practical algorithms for fast, cost-based optimal dispatch and for determining the optimal amount of headroom to operate solar inverters with to support FFR dispatch while minimizing opportunity cost. Simulation results in Part I demonstrated the advantages of the hierarchical dispatch approach in being able to maintain fast solution times needed for FFR even when the problem size increases. In Part II, we implement the algorithms developed in Part I in a novel, large-scale power hardware-in-the-loop experiment including embedded controllers and more than 100 powered appliance loads and DER connected to a simulated real-world distribution system with more than 10,000 controlled devices. Experimental results from multiple scenarios confirm that the optimal FFR dispatch approach scales well and can optimally coordinate more than 10,000 net-load resources across a distribution network while achieving hardware response times within 500 ms, which is not possible using state-of-the-art optimal coordination approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency response fo multiple-sampling rate systems

Analytical procedure simplifies prediction of frequency response of multirate digital control systems. Although developed for Space Shuttle flightcontrol system, procedure is applicable to any multirate system describable by linear, constant-coefficient differential equations of difference equations.

Scharmack, D. K.↗

Extracting maximal frequency response potential in controllable loads

Methods and apparatus are disclosed for extracting maximal frequency response potential in controllable loads. In one example, a method includes assigning a fitness metric to at least one electrical device coupled to a power grid, assigning a frequency threshold based on the fitness metric, and transmitting the assigned frequency threshold to the at least one electrical device. The fitness metric can be based at least in part on an availability component and a quality component associated with the at least one device and the frequency threshold can cause the at least one electrical device to activate autonomously based on a frequency of the power grid.

Lian, Jianming↗

Enhanced Inertial Support: Modeling Fast Frequency Response Controls for Energy Storage System Inverters

Reduction of power system inertia is a growing concern for grid operators given the transition under way from conventional fossil generators to inverter-based resources. One key concern is the rapid and severe dip in power system frequency following a large disturbance which could trigger remedial actions including operation of under frequency load shedding (UFLS) relays. A potential solution is to utilize battery energy storage systems (BESS) to provide fast frequency response(FFR) to mitigate the system frequency impact of low system inertia. In this work, we investigate different control parameters to achieve modeled FFR response from BESS in the simulated US Western Interconnection. First, a very low inertia model is developed from an existing positive sequence model of the Western Interconnection. Afterwards, we tune the BESS dynamic response parameters to eliminate any risks of reaching UFLS relay thresholds following the loss of large generators. Finally, we investigate the relative impact of having large BESS units in comparison of multiple smaller units in the same area. The results of the analyses indicate that 1 GW of transmission-connected BESS can help mitigate the frequency drop caused by large generators outages in the Western Interconnection, and significantly reduce the risk of under frequency load shedding.

power system dynamic performance, Low Inertia, Fas↗

Review and status of tool tip frequency response function prediction using receptance coupling

This paper provides a chronological review of publications that implement and advance the receptance coupling substructure analysis (RCSA) approach first applied to tool tip receptance (or frequency response function) prediction for milling applications in 2000. The review topics mimic the RCSA approach, where the tool, holder, and spindle-machine receptances are coupled analytically, and include: tool-holder receptance modeling; connection modeling; spindle-machine receptances; and applications. The review paper summarizes contributions from multiple, international authors (198 papers) to these topics. Additionally, it provides a comprehensive resource for those beginning an investigation into RCSA.

42 ENGINEERING↗

Extending the operating temperature, wavelength and frequency response of HgCdTe heterodyne detectors

Near ideal optical heterodyne performance was obtained at GHz IF frequencies in the 10 micrometer wavelength region with liquid nitrogen cooled HgCdTe photodiodes. Heterodyne NEP's as low as 2.7 x 10 to the minus 20th power W/Hz at 100MHz, 5.4 x 10 to the minus 20th power W/Hz at 1.5 GHz, and 9.4 x 19 to the minus 20th power W/Hz at 3 GHz were achieved. Various physical phenomena which occur within a photodiode and affect heterodyne operation were examined in order to assess the feasibility of extending the operating temperature, wavelength, and frequency response of these HgCdTe photomixers.

Spears, D. L.↗

OC6 phase I: Improvements to the OpenFAST predictions of nonlinear, low-frequency responses of a floating offshore wind turbine platform

We report in the OC5 and OC6 projects, the authors observed a persistent underprediction of the nonlinear, low-frequency responses of an offshore wind semisubmersible with many mid-fidelity engineering models, including the OpenFAST tool developed by the National Renewable Energy Laboratory. Both the low-frequency wave excitation in surge and pitch and the resulting resonance motions were severely underpredicted. In response, we developed several modifications to the OpenFAST model from the OC5/6 projects to improve the predictions of the low-frequency wave loads and responses. All modifications are in the modeling of the viscous drag forces. Efforts were made to provide physical justifications to the changes and to limit the number of additional parameters requiring tuning, so that the modified model can be applied to other floating wind systems. With the proposed modifications, the predictions of the low-frequency surge and pitch wave loads on a fixed floater and the resonance responses of a floating structure are both significantly improved with a single set of model coefficients, which leads to good agreement with the measurements from the OC6 wave-basin experimental campaign.

17 WIND ENERGY↗