Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fast frequency response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Robust Output Feedback Control Design for Inertia Emulation by Wind Turbine Generators

Wind generation has gained widespread use as a renewable energy source. Most wind turbines and other renewables connected to the grid through converters result in a reduction in the natural inertial response to grid frequency changes. The doubly-fed induction generator (DFIG) can be controlled to compensate for this reduction and, in fact, provide faster response than traditional synchronous machines. This paper proposes to design observer based output feedback linear quadratic regulator (LQR) and H control laws to realize the inertia emulation function and deliver fast frequency support. Furthermore, the aim is to track the reference speed by a diesel synchronous generator (DSG) in order to reach the desired inertia. The control signal is computed based on a reduced order model using the balanced truncation technique. A comparison with selective modal analysis (SMA) and balanced truncation model reduction techniques is presented. Comprehensive results show the effective emulation of synthetic inertia by implementing the control laws on a nonlinear three- phase diesel-wind system. The proposed technique is analyzed for different short circuit ratio (SCR) scenarios.

17 WIND ENERGY↗

State-Space Realization of the Wave-Radiation Force within FAST: Preprint

Several methods have been proposed in the literature to find a state-space model for the wave-radiation forces. In this paper, four methods were compared, two in the frequency domain and two in the time domain. The frequency-response function and the impulse response of the resulting state-space models were compared against the ones derived by the numerical code WAMIT. The implementation of the state-space module within the FAST offshore wind turbine computer-aided engineering (CAE) tool was verified, comparing the results against the previously implemented numerical convolution method. The results agreed between the two methods, with a significant reduction in required computational time when using the state-space module.

17 WIND ENERGY↗

Modeling and a correlation algorithm for spaceborne SAR signals

A mathematical model of a spaceborne synthetic aperture radar (SAR) response is presented. Thhe associated SAR system performance, in terms of the resolution capability, is also discussed. The analysis of spaceborne SAR target response indicates that the SAR correlation problem is a two-dimensional one with a linear shift-variant response function. A new digital processing algorithm is proposed here in order to realize an economical digital SAR correlation system. The proposed algorithm treats the two-dimensional correlation by a combination of frequency domain fast correlation in the azimuth dimension and a time-domain convolver type of operation in the range dimension. Finally, digitally correlated SEASAT satellite SAR imagery is used in an exemplary sense to validate the SAR response model and the new digital processing technique developed.

Wu, C.↗

A Discrete-Time Average Model Based Predictive Control for Quasi-Z-Source Inverter

A discrete-time average model-based predictive control (DTA-MPC) is proposed for a quasi-Z-source inverter (qZSI). As a single-stage inverter topology, the qZSI regulates the dc-link voltage and the ac output voltage through the shoot-through (ST) duty cycle and the modulation index. Several feedback strategies have been dedicated to produce these two control variables, among which the most popular are the proportional–integral (PI)-based control and the conventional model-predictive control (MPC). However, in the former, there are tradeoffs between fast response and stability; the latter is robust, but at the cost of high calculation burden and variable switching frequency. Moreover, they require an elaborated design or fine tuning of controller parameters. The proposed DTA-MPC predicts future behaviors of the ST duty cycle and modulation signals, based on the established discrete-time average model of the quasi-Z-source (qZS) inductor current, the qZS capacitor voltage, and load currents. The prediction actions are applied to the qZSI modulator in the next sampling instant, without the need of other controller parameters’ design. A constant switching frequency and significantly reduced computations are achieved with high performance. Transient responses and steady-state accuracy of the qZSI system under the proposed DTA-MPC are investigated and compared with the PI-based control and the conventional MPC. Simulation and experimental results verify the effectiveness of the proposed approach for the qZSI.

42 ENGINEERING↗

A Real-Time Microwave Camera at K-Band (24 GHz)

Nondestructive testing (NDT) community has been moving towards effective and robust inspection systems that can provide real-time information about materials, geometrical, structural and mechanical characteristics of composite materials/structures. Moreover, in many applications it is desired to have an image of the structure, after which the information contained in the image is correlated to the above characteristics. Microwave signals penetrate inside of dielectric composite structures and their interaction with the interior of the structure renders critical information for NDT purposes. Subsequently, this information (i.e., magnitude and phase or reflected signal) may be used to produce an image of the interior of the structure revealing potential flaws or anomalies. Image processing and reconstruction techniques may also be incorporated to produce high-resolution images (i.e., synthetic-aperture, back-propagation, etc.). There are several different approaches for designing areal-time microwave camera system. One approach is based on modulated scatterer technique (MST), which is used to tag scattered electric field in a discrete two-dimensional (2D) spatial domain (e.g. a retina) resulting in the 2D magnitude and phase distribution of the scattered electric field which is required for producing an image of a material or structure under inspection. The ability to rapidly modulate resonant slot antennas in such a retina along with using receivers with fast responses provide for real-time image production capability. Design issue and criteria become more challenging at higher frequencies and for a relatively large retina size. This paper presents the basic design and challenges for a microwave camera with a retina size of 6" by 6" operating at a frequency of 24 GHz.

Ghasr, M. T.↗

Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET

State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Examining the Feasibility of Modeling the Inner Current Loop of a Grid-Following Inverter in the Phasor-Based Solver

Historically, when modeling a grid-following (GFL) inverter in the phasor domain, the fast inner current loop is typically ignored. To achieve a more accurate modeling, the authors have attempted to model the inner current loop in the phasor domain, but experienced significant numerical stability issues. This paper conducts a detailed analysis and provides insight into the feasibility of modeling the inner current loop of a GFL inverter in the phasor domain. It points out that: a) because of the neglection of the inverter filter dynamic, the bandwidth of the inner current loop becomes infinite with typical parameters in the phasor domain, resulting in an inaccurate representation of the actual inner current loop, whose bandwidth is typically between 600 Hz to 2 kHz, and b) the relatively large simulation time step in the phasor simulation causes numerical stability issues when simulating such an inner current loop with an infinite bandwidth. Detailed electromagnetic (EMT) and phasor modeling, and frequency response analysis are performed to explain this phenomenon. The findings of this paper explain why it is inappropriate to model the fast current loop of a GFL inverter in the phasor domain.

Mohiuddin, Sheik Mohammad↗

Spinning Reserve From Hotel Load Response: Initial Progress

This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby and Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Data-Driven Based HVdc Ancillary Control for Multiple Frequency Data Attacks

The high voltage direct current (HVdc) intertie has been applied to provide ancillary-services for ac grids, utilizing the real-time feedback from phasor measurement units (PMUs). However, PMU data communication is vulnerable to false data injection attacks (FDIA) due to protocol defects, thus the HVdc ancillary control and system stability will be threatened. To address this issue, this article proposes a novel HVdc control strategy based on a hybrid data-driven (HDD) methodology. In this work, the HDD methodology is first proposed to detect the types and duration time of multiple frequency attacks. Specifically, the Hilbert Huang transform (HHT) is used to decompose the frequency data, using variational mode decomposition instead of the traditional empirical mode decomposition, to extract data features. Second, a multikernel support vector machine is proposed to classify the attacked data based on the designed distinctive features from HHT. Meanwhile, the attacking duration time is decided using an unsupervised technique. Third, an HDD-based HVdc ancillary control strategy is established to eliminate the effect of FDIAs on the HVdc frequency response. Comprehensive experiments of HDD-based HVdc ancillary controls under different FDIAs suggest that the proposed HDD could fast and accurately classify the FDIAs, and the HDD-based HVdc ancillary control strategy could significantly suppress the impact of the FDIAs.

97 MATHEMATICS AND COMPUTING↗

Nonlinear dynamics of multiple Alfvén modes driven by trapped energetic ions in tokamaks: A triplet paradigm

Non-linear dynamics of multiple infernal Alfvén eigenmodes—a subset of global Alfvén eigenmodes in tokamak plasmas with extended low-shear central core [Marchenko et al., Phys. Plasmas 16, 092502 (2009)]—is studied. The analysis is carried out for a mode triplet with toroidal mode-numbers n=1, 2, 3. It was assumed that the n = 1 mode was linearly unstable due to precession resonance with trapped fast ions, whereas the other modes were linearly damped. The modes were coupled due to a non-linearity in a bounce-averaged drift kinetic equation for the distribution function of fast ions. Nonlinear equations for the mode amplitudes and phases are derived and solved numerically. It is found that the temporal evolution of the amplitudes and the phase (responsible for the frequency chirping) of the modes exhibit Hopf bifurcations to stable limit cycles. This can explain a synchronous cyclic destabilization of multiple modes in Alfvén avalanches (sudden growth of amplitudes of the mode cluster with different n and approximately equal frequency spacing) in NSTX and bursting modes in MAST—events, which resulted in enhanced loss of fast ions.

Marchenko, V. S. (ORCID:0000000261480533)↗

The effect of simulator dynamics on pilot response

The effects of visual display dynamics on the altitude tracking performance of a subject in a fixed base flight simulator are considered. The subject, flying the linearized longitudinal equations of motion, attempts to maintain the same altitude as two airplanes positioned three hundred feet ahead, as in level formation flying. The horizon together with the two leading aircraft are represented symbolically on a CRT display. The subject's aircraft is disturbed by atmospheric turbulence. The data indicate a relationship between the bandwidth of the display dynamics and the short period characteristics of the simulated airplane. For an airplane with a relatively fast pitch response the presence of altitude display dynamics, with a bandwidth as high as five times the short period natural frequency, causes significant degradation of altitude tracking performance.

Weener, E. F.↗

Profile modification to minimize spur gear dynamic loading

An analytical computer simulation program for dynamic modeling of low-contact-ratio spur gear systems is presented. The procedure computes the static transmission error of the gears operating under load and uses a fast Fourier transform to generate the frequency spectrum of the static transmission error at various tooth profile modifications. The dynamic loading response of an unmodified (perfect involute) gear pair was compared with that of gears with various profile modifications. Correlations were found between various profile modifications and the resulting dynamic loads. An effective error, obtained from frequency domain analysis of the static transmission error of the gears, gave a very good indication of the optimum profile modification to reduce gear dynamic loading. Design curves generated by dynamic simulation at various profile modifications are given for gear systems operated at various loads. Optimum profile modifications can be determined from these design curves for improved gear design.

Lin, Hsiang Hsi↗

Profile modification to minimize spur gear dynamic loading

An analytical computer simulation program for dynamic modeling of low-contact-ratio spur gear systems is presented. The procedure computes the static transmission error of the gears operating under load and uses a fast Fourier transform to generate the frequency spectrum of the static transmission error at various tooth profile modifications. The dynamic loading response of an unmodified (perfect involute) gear pair was compared with that of gears with various profile modifications. Correlations were found between various profile modifications and the resulting dynamic loads. An effective error, obtained from frequency domain analysis of the static transmission error of the gears, gave a very good indication of the optimum profile modification to reduce gear dynamic loading. Design curves generated by dynamic simulation at various profile modifications are given for gear systems operated at various loads. Optimum profile modifications can be determined from these design curves for improved gear design.

Lin, H. H.↗

Field Micrometeorological Measurements, Process-Level Studies and Modeling of Methane and Carbon Dioxide Fluxes in a Boreal Wetland Ecosystem

The main instrumentation platform consisted of eddy correlation sensors mounted on a scaffold tower at a height of 4.2 m above the peat surface. The sensors were attached to a boom assembly which could be rotated into the prevailing winds. The boom assembly was mounted on a movable sled which, when extended, allowed sensors to be up to 2 m away from the scaffolding structure to minimize flow distortion. When retracted, the sensors could easily be installed, serviced or rotated. An electronic level with linear actuators allowed the sensors to be remotely levelled once the sled was extended. Two instrument arrays were installed. A primary (fast-response) array consisted of a three-dimensional sonic anemometer, a methane sensor (tunable diode laser spectrometer), a carbon dioxide/water vapor sensor, a fine wire thermocouple and a backup one-dimensional sonic anemometer. The secondary array consisted of a one-dimensional sonic anemometer, a fine wire thermocouple and a Krypton hygrometer. Descriptions of these sensors may be found in other reports (e.g., Verma; Suyker and Verma). Slow-response sensors provided supporting measurements including mean air temperature and humidity, mean horizontal windspeed and direction, incoming and reflected solar radiation, net radiation, incoming and reflected photosynthetically active radiation (PAR), soil heat flux, peat temperature, water-table elevation and precipitation. A data acquisition system (consisting of an IBM compatible microcomputer, amplifiers and a 16 bit analog-to-digital converter), housed in a small trailer, was used to record the fast response signals. These signals were low-pass filtered (using 8-pole Butterworth active filters with a 12.5 Hz cutoff frequency) and sampled at 25 Hz. Slow-response signals were sampled every 5 s using a network of CR21X (Campbell Scientific, Inc., Logan Utah) data loggers installed in the fen. All signals were averaged over 30-minute periods (runs).

Verma, S. B.↗

Polarimetry-Interferometry Diagnostic for Magnetic Field and Magnetic Fluctuation Measurements in High-Performance and Long-Pulse Tokamaks (Final Report)

In this grant, we executed a multi-year plan to develop an advanced Faraday-effect polarimeter-interferometer system to address both fluctuation and equilibrium diagnostic needs by providing a measurement of the plasma internal magnetic field fluctuations (including non-axisymmetric 3-D perturbations) and plasma vertical position. This diagnostic included both fast time response and low phase noise so that both the temporal dynamics of equilibrium quantities as well as high-frequency electromagnetic fluctuations could be measured simultaneously, adding new and unique measurement capabilities for the core of high-temperature plasmas. The combined polarimeter-interferometer diagnostic development was applied primarily to the tokamak magnetic configuration, focusing on high-performance regimes including H-mode, reversed shear advanced tokamak scenarios, and non-inductive current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of Second-Order Hydrodynamics on a Semisubmersible Floating Offshore Wind Turbine: Preprint

The objective of this paper is to assess the second-order hydrodynamic effects on a semisubmersible floating offshore wind turbine. Second-order hydrodynamics induce loads and motions at the sum- and difference-frequencies of the incident waves. These effects have often been ignored in offshore wind analysis, under the assumption that they are significantly smaller than first-order effects. The sum- and difference-frequency loads can, however, excite eigenfrequencies of the system, leading to large oscillations that strain the mooring system or vibrations that cause fatigue damage to the structure. Observations of supposed second-order responses in wave-tank tests performed by the DeepCwind consortium at the MARIN offshore basin suggest that these effects might be more important than originally expected. These observations inspired interest in investigating how second-order excitation affects floating offshore wind turbines and whether second-order hydrodynamics should be included in offshore wind simulation tools like FAST in the future. In this work, the effects of second-order hydrodynamics on a floating semisubmersible offshore wind turbine are investigated. Because FAST is currently unable to account for second-order effects, a method to assess these effects was applied in which linearized properties of the floating wind system derived from FAST (including the 6x6 mass and stiffness matrices) are used by WAMIT to solve the first- and second-order hydrodynamics problems in the frequency domain. The method has been applied to the OC4-DeepCwind semisubmersible platform, supporting the NREL 5-MW baseline wind turbine. The loads and response of the system due to the second-order hydrodynamics are analysed and compared to first-order hydrodynamic loads and induced motions in the frequency domain. Further, the second-order loads and induced response data are compared to the loads and motions induced by aerodynamic loading as solved by FAST.

17 WIND ENERGY↗

Evaluation of the first version of the new RFPI system dedicated to PIP-II project accelerator

The Low-Level Radio Frequency (LLRF) control system is one of the most critical superconducting linac infrastructures responsible for the parameters of the beam acceleration. The LLRF system mainly focuses on the electromagnetic field parameters inside the cavity. While it incorporates fast feedback algorithms to optimize energy transfer to the passing particle beam it does not follow other cryomodule or cavity parameter changes. The Radio Frequency Protection Interlock (RFPI) system closely monitors various factors (like cryomodule vacuum, beamline vacuum, field emission probe current level, temperature, RF signal leakage, etc). Its simple but reliable logic has to provide an instant decision about the LLRF system or high-power amplifier output signal blocking in case of safety region excitation. This contribution presents a new version of the RFPI system which logic is implemented in the FPGA chip. The initial work on the prototype of the new system design resulted in the PoC (Proof of Concept) device. The PoC offers the possibility of various protection logic configurations, input signals parameters evaluation, and modularity aspects verification. The structure and test results from the device evaluation are summarized and discussed in this contribution.

43 PARTICLE ACCELERATORS↗

Expanded Accident Scenarios and Frequency Characteristics for a Fast Spectrum Molten Salt Reactor in an Integrated Energy System

Integration of advanced nuclear reactors to industrial processes in an integrated energy system (IES) has many potential advantages. The coupling of nuclear power to varied industrial processes introduces additional accident scenarios unique to the specific systems included in the IES. Similarly, noise in one system of the IES could potentially create negative effects in the other systems. Because of the limited amount of comparable nuclear IES operating experience, there is added value in scoping the inherent behavior of these systems in response to these transients. Here, this paper investigates the safety-related behavior of an open-source IES dynamic model of a fast spectrum molten salt reactor (MSR) powering a regenerative Rankine cycle for electricity production and a hybrid sulfur (HyS) cycle for hydrogen production. The simulations include a loss of cooling water to the Rankine cycle, a loss of sulfur in the HyS cycle, and the frequency characteristics of the entire IES across six orders of magnitude of frequency. The results show safe behavior in response to the two accident scenarios, wherein a disruption in heat transfer leads to increased salt temperatures and a decrease in reactor power. The frequency analysis shows that at higher frequencies, temperature changes propagating through an IES are increasingly damped to the point of negligibility.

Dunkle, Nicholas [Univ. of Tennessee, Knoxville, T↗