Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “equipment selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Spacelab simulation using a Lear Jet aircraft: Mission no. 4 (ASSESS program)

The fourth ASSESS Spacelab simulation mission utilizing a Lear Jet aircraft featured trained experiment operators (EOs) in place of the participating scientists, to simulate the role and functions of payload specialists in Spacelab who may conduct experiments developed by other scientists. The experiment was a broadband infrared photometer coupled to a 30-cm, open port, IR telescope. No compromises in equipment design or target selection were made to simplify operator tasks; the science goals of the mission were selected to advance the mainline research program of the principle investigator (PI). Training of the EOs was the responsibility of the PI team and consisted of laboratory sessions, on-site training during experiment integration, and integrated mission training using the aircraft as a high-fidelity simulator. The EO permission experience in these several disciplines proved adequate for normal experiment operations, but marginal for the identification and remedy of equipment malfunctions. During the mission, the PI utilized a TV communication system to assist the EOs to overcome equipment difficulties; both science and operations were successfully implemented.

Reller, J. O., Jr.↗

Space station common module network topology and hardware development

Conceptual space station common module power management and distribution (SSM/PMAD) network layouts and detailed network evaluations were developed. Individual pieces of hardware to be developed for the SSM/PMAD test bed were identified. A technology assessment was developed to identify pieces of equipment requiring development effort. Equipment lists were developed from the previously selected network schematics. Additionally, functional requirements for the network equipment as well as other requirements which affected the suitability of specific items for use on the Space Station Program were identified. Assembly requirements were derived based on the SSM/PMAD developed requirements and on the selected SSM/PMAD network concepts. Basic requirements and simplified design block diagrams are included. DC remote power controllers were successfully integrated into the DC Marshall Space Flight Center breadboard. Two DC remote power controller (RPC) boards experienced mechanical failure of UES 706 stud-mounted diodes during mechanical installation of the boards into the system. These broken diodes caused input to output shorting of the RPC's. The UES 706 diodes were replaced on these RPC's which eliminated the problem. The DC RPC's as existing in the present breadboard configuration do not provide ground fault protection because the RPC was designed to only switch the hot side current. If ground fault protection were to be implemented, it would be necessary to design the system so the RPC switched both the hot and the return sides of power.

Anderson, P.↗

Greenidge multi-pollutant project achieves emissions reduction goals

Performance testing at the Greenridge Multi-Pollutant Project has met or exceeded project goals, indicating that deep emission reduciton sin small, difficult-to-retrofit power plants can be achieved. The technology fitted at the 107 MWe AES Greenridge Unit 4 includes a hybrid selective non-catalytic reduction/selective catalytic reduction system for NOx control (NOxOUT CASCADE) and a Turbosorp circulating fluidized bed dry scrubber system for SO{sub 2}, mercury, SO{sub 3} HC and Hf control. 2 figs.

01 COAL, LIGNITE, AND PEAT↗

Study directed at development of an implantable biotelemetry ion detector

A literature search was conducted to currently update known information in the field of ion-selective electrodes. The review attempts to identify present trends in cation and anions selective electrodes pertinent to the area of bioimplantable units. An electronic circuit was designed to provide the high impedance interface between the ion-selective sensors and signal-processing equipment. The resulting design emphasized the need for low power and miniaturization. Many of the circuits were constructed and used to evaluate the ion-selective electrodes. A cuvette capable of holding the ion-selective and the reference electrodes was designed and constructed. This equipment was used to evaluate commercially available ion-selective electrodes and the electrodes designed and constructed in the study. The results of the electrode tests are included.

Hanley, L. D.↗

Fast BPM data distribution for global orbit feedback using commercial gigabit ethernet technology

In order to correct beam perturbations in RHIC around 10Hz, a new fast data distribution network was required to deliver BPM position data at rates several orders of magnitude above the capability of the existing system. The urgency of the project limited the amount of custom hardware that could be developed, which dictated the use of as much commercially available equipment as possible. The selected architecture uses a custom hardware interface to the existing RHIC BPM electronics together with commercially available Gigabit Ethernet switches to distribute position data to devices located around the collider ring. Using the minimum Ethernet packet size and a field programmable gate array (FPGA) based state machine logic instead of a software based driver, real-time and deterministic data delivery is possible using Ethernet. The method of adapting this protocol for low latency data delivery, bench testing of Ethernet hardware, and the logic to construct Ethernet packets using FPGA hardware will be discussed. A robust communications system using almost all commercial off-the-shelf equipment was developed in under a year which enabled retrofitting of the existing RHIC BPM system to provide 10 KHz data delivery for a global orbit feedback scheme using 72 BPMs. Total latencies from data acquisition at the BPMs to delivery at the controller modules, including very long transmission distances, were kept under 100 {micro}s, which provide very little phase error in correcting the 10 Hz oscillations. Leveraging off of the speed of Gigabit Ethernet and wide availability of Ethernet products enabled this solution to be fully implemented in a much shorter time and at lower cost than if a similar network was developed using a proprietary method.

43 PARTICLE ACCELERATORS↗

Multi-Phased, Post-Accident Support of the Fukushima Dai-Ichi Nuclear Power Plant - 12246

In the wake of the March 11 earthquake and tsunami and the subsequent flooding of several of the Fukushima Dai-Ichi reactors, Japan and the Japanese utility TEPCO faced a crisis situation with incredible challenges: substantial amounts of radioactive mixed seawater and freshwater accumulated in the basements of four reactor and other buildings on the site. This water held varying levels of contamination due to the fact that it had been in contact with damaged fuel elements in the cores and with other contaminated components. The overall water inventory was estimated at around 110,000 tons of water with contamination levels up to the order of 1 Ci/l. Time was of the essence to avoid overflow of this accumulated water into the ocean. AREVA proposed, designed and implemented a water treatment solution using a proven chemical coprecipitation process with ppFeNi reagent, which is currently in use for effluent treatment on several nuclear sites including AREVA sites. In addition to the extremely short schedule the other challenge was to adapt the chemical treatment process to the expected composition of the Fukushima water and, in particular, to evaluate the impact of salinity on process performance. It was also necessary to define operating conditions for the VEOLIA equipment that had been selected for implementation of the process in the future facility. The operation phase began on June 17, and by the end of July more than 30,000 tons of highly radioactive saltwater had been decontaminated - the Decontamination Factor (DF) for Cesium was ∼10{sup 4}. It allowed recycling the contaminated water to cool the reactors while protecting workers and the environment. This paper focuses on the Actiflo{sup TM}-Rad water treatment unit project that was part of the TEPCO general water treatment scheme. It presents a detailed look at the principles of the Actiflo{sup TM}-Rad, related on-the-fly R and D, an explanation of system implementation challenges, and a brief summary of operation results to date. AREVA's response to the Fukushima Dai-Ichi crisis was multi-phased: emergency aid and relief supply was sent within days after the accident; AREVA-Veolia engineering teams designed and implemented a water treatment solution in record time, only 3 months; and AREVA continues to support TEPCO and propose solutions for waste management, soil remediation and decontamination of the Fukushima Dai-Ichi site. Despite the huge challenges, the Actiflo{sup TM}-Rad project has been a success: the water treatment unit started on time and performed as expected. The performance is the result of many key elements: AREVA expertise in radioactive effluents decontamination, Veolia know-how in water treatment equipments in crisis environment, and of course AREVA and Veolia teams' creativity. The project success is also due to AREVA and Veolia teams' reactivity and high level of commitment with engineering teams working 24/7 in Japan, France and Germany. AREVA and Veolia deep knowledge of the Japanese industry ensured that the multi-cultural exchanges were not an issue. Finally the excellent overall project management and execution by TEPCO and other Japanese stakeholders was very efficient. The emergency water treatment was a key step of the roadmap towards restoration from the accident at Fukushima Dai-Ichi that TEPCO designed and keeps executing with success. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling of the Reactor Core Isolation Cooling Response to Beyond Design Basis Operations - Interim Report

Efforts are being pursued to develop and qualify a system-level model of a reactor core isolation (RCIC) steam-turbine-driven pump. The model is being developed with the intent of employing it to inform the design of experimental configurations for full-scale RCIC testing. The model is expected to be especially valuable in sizing equipment needed in the testing. An additional intent is to use the model in understanding more fully how RCIC apparently managed to operate far removed from its design envelope in the Fukushima Daiichi Unit 2 accident. RCIC modeling is proceeding along two avenues that are expected to complement each other well. The first avenue is the continued development of the system-level RCIC model that will serve in simulating a full reactor system or full experimental configuration of which a RCIC system is part. The model reasonably represents a RCIC system today, especially given design operating conditions, but lacks specifics that are likely important in representing the off-design conditions a RCIC system might experience in an emergency situation such as a loss of all electrical power. A known specific lacking in the system model, for example, is the efficiency at which a flashing slug of water (as opposed to a concentrated jet of steam) could propel the rotating drive wheel of a RCIC turbine. To address this specific, the second avenue is being pursued wherein computational fluid dynamics (CFD) analyses of such a jet are being carried out. The results of the CFD analyses will thus complement and inform the system modeling. The system modeling will, in turn, complement the CFD analysis by providing the system information needed to impose appropriate boundary conditions on the CFD simulations. The system model will be used to inform the selection of configurations and equipment best suitable of supporting planned RCIC experimental testing. Preliminary investigations with the RCIC model indicate that liquid water ingestion by the turbine decreases the developed turbine torque; the RCIC speed then slows, and thus the pump flow rate to the RPV decreases. Subsequently, RPV water level decreases due to continued boiling and the liquid fraction flowing to the RCIC decreases, thereby accelerating the RCIC and refilling the RPV. The feedback cycle then repeats itself and/or reaches a quasi-steady equilibrium condition. In other words, the water carry-over is limited by cyclic RCIC performance degradation, and hence the system becomes self-regulating. The indications achieved to date with the system model are more qualitative than quantitative. The avenues being pursued to increase the fidelity of the model are expected to add quantitative realism. The end product will be generic in the sense that the RCIC model will be incorporable within the larger reactor coolant system model of any nuclear power plant or experimental configuration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Selective Shielding Bone Marrow: An Approach to Create Personal Protective Equipment for Gamma Radiation

Many casualties of the Hiroshima and Nagasaki atomic bombs, and many of the firefighters who first responded to the Chernobyl nuclear power plant accident, became ill with acute radiation syndrome (ARS). Most of the people who do not recover from ARS will die within a few weeks to a few months after exposure, with the primary cause of death being the destruction of the body's bone marrow (BM). This is exemplified by the Chernobyl firefighters, the majority of whom received whole body doses between 0.8 and 10 Gy, and the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) final report on the disaster concluded that the underlying cause of death of all 28 firefighters who succumbed to ARS was from bone marrow failure. BM is comprised of hematopoietic stem cells (HSCs) which are responsible for the constant renewal of blood cells. Due to their high rate of proliferation, HSCs are especially vulnerable to ionizing radiation, but are endowed with remarkable regenerative potential. Owing to their central role in blood production, lethal irradiation of HSCs leads to death from severe anemia, infection and internal bleeding. This relationship between high doses of radiation and HSC apoptosis has led to the use of HSC transplantation as a life-saving intervention in cases of acute exposure. This is demonstrable in medical practice, where thousands of individuals have undergone supra-lethal Total Body Irradiation (TBI) for purposes of cancer therapy, and were rescued by well-matched BM transplantation. Indeed, life-threatening damage may be reversed by BM transplantation in individuals receiving doses of radiation of up to 10 Gy. At doses > 10 Gy, damage to gastrointestinal (GI) tissue may become a limiting factor in survival. Remarkably, in the common procedure of BM transplantation, the number of HSCs extracted from a single active BM site containing less than 5% of the donor's BM tissue is sufficient to support the complete reconstitution of the HSC compartment in a lethally irradiated recipient. This capacity of BM to expand and replenish is due to the high regenerative potential of the HSCs it harbors. In contrast to mature blood cells, which are dispersed throughout the body, HSCs are confined to the bones, allowing for effective targeted shielding. This has been confirmed in several animal models, where sparing the HSC-rich area of a subject receiving otherwise full-body irradiation is sufficient to support hematopoietic functions and allow survival. Approximately 48% of the human body's active BM is contained within the lumbar vertebrae and the pelvic region. This high concentration of BM makes the pelvic region an ideal area to shield for preventing the serious hematopoietic effects of radiation exposure. Stem-cell rich tissues like active BM are also more sensitive to the stochastic effects (i.e. cancer) of radiation exposure. The high amount of BM in the pelvic region, combined with the presence of the sensitive gastrointestinal system and female gonads in this same area of the body allows for the possibility of significantly reducing stochastic effects of radiation by limiting radiation exposure to this vital area. Thus, shielding this region holds great promise for both acute and protracted exposures. Thus, a specialized radiation shielding device for the protection of active BM concentrations is presented here. This belt-like selective shielding device focuses on the protection of BM that is present in the pelvis and hip bones, protecting the medullary volume from which BM is commonly extracted for transplantation (i.e. the iliac bones) while allowing relatively unhindered movement of the wearer. In order to optimize the use of shielding materials towards the protection of active BM, the shielding uniquely brings into account the natural shielding properties of human tissue, with thickness being inversely related to the thickness and radiation attenuation of the underlying tissue at each point surrounding the area being protected. The findings resulting from both experimental and simulation testing of this selective shielding device are presented here.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the challenges facing the handling of solid biomass feedstocks: On the Challenges Facing the Handling of Solid Biomass Feedstocks

With a major global emphasis on the management of waste, alternative resources and a shift to environmentally sustainable technologies, demand for large volumes of heterogeneous solid biomass feedstocks for energy or chemical use is expected to rise significantly. In transforming a sporadic supply of a low-value, highly variable product, to continuous and controlled high throughput systems, a thorough understanding of the feedstock properties will increase in importance. Appropriate characterisation tests are necessary to define technical specification and selection criteria for handling equipment and to appraise the requirement and location for additional processes or pre-treatment to be integrated into the handling chain. Such tests may also influence the material characteristics to be used in the conversion process. In this paper, we discuss the main feedstock attributes associated with a number of handling chain phases and the approach to obtain them. Lastly, the framework for a holistic approach to the characterisation and design of biomass feedstock handling systems for further development and practical implementation is also proposed.

09 BIOMASS FUELS↗

ByzSec — A Multi-layered Byzantine Resilient Architecture for Bulk Power System Protective Relays

Reliability, selectivity, and sensitivity are the fundamental attributes of any protection system, acting as the main drivers in the selection of schemes, and equipment. In high-voltage systems, microprocessor-based relays represent the industry’s preferred solution, providing engineers with a vast array of benefits. However, they remain vulnerable to cybersecurity events that may compromise their functionality. To help mitigate against potential cybersecurity risks, this paper presents a fault-tolerant, Byzantine Resilient (BR) architecture that significantly increases the cybersecurity attributes of a protection system while minimizing the amount of performance impacts and integration overheads introduced. The solution relies on an array of independent relays that utilize robust consensus methods (based on Spire [1], [2]) to ensure correct system behavior is achieved even when a relay has been compromised. Furthermore, the solution has been complemented with a custom-built Situational Awareness engine that can be used to detect and identify potential threats. The implemented solution has been developed in consultation with three hardware vendors and has been tested to comply with the performance requirements of a 345kV differential protection scheme (87T). The results indicate that the proposed architecture is a comprehensive solution that: supports the strict correctness and performance requirements of the bulk power grid while providing a cost-effective alternative that offers a seamless, long-term solution.

byzantine security, Fault Tolerant Application Sof↗

Review—Electrochemical Measurements in Molten Salt Systems: A Guide and Perspective

Practical information is provided on electrochemical measurements in molten salt systems. The emphasis is on chloride and fluoride systems, but the principles are applicable to any high temperature molten salt or molten oxide electrolyte system. Considerations are given to topics such as the functionality of electrochemical measurement equipment, reference electrodes, materials selection and chemical compatibility, interpretation of electrochemical measurement signals, molten salt properties, and laboratory practices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of the Tellabs 1150 GPON multiservice access platform

For over two years, Sandia National Laboratories has been using a Gigabit Passive Optical Network (GPON) access layer for selected networks. The GPON equipment includes the Tellabs 1150 Multiservice Access Platform (MSAP) Optical Line Terminal (OLT), the Tellabs ONT709 and ONT709GP Optical Network Terminals (ONTs), and the Panorama PON Network Manager. In late 2013, the Tellabs equipment was updated to Software Release FP27.1_015130. Because a new software release has the potential to affect performance and functionality, it needed to be thoroughly tested. This report documents that testing. It also provides a comparison between the current release and the previous Software Release FP25.5.1_013274 that was being used.

97 MATHEMATICS AND COMPUTING↗

Evaluation of the Tellabs 1150 GPON multiservice access platform

For over two years, Sandia National Laboratories has been using a Gigabit Passive Optical Network (GPON) access layer for selected networks. The GPON equipment includes the Tellabs 1150 Multiservice Access Platform (MSAP) Optical Line Terminal (OLT), the Tellabs ONT709 and ONT709GP Optical Network Terminals (ONTs), and the Panorama PON Network Manager. In late 2013, the Tellabs equipment was updated to Software Release FP27.1_015130. Because a new software release has the potential to affect performance and functionality, it needed to be thoroughly tested. This report documents that testing. It also provides a comparison between the current release and the previous Software Release FP25.5.1_013274 that was being used.

97 MATHEMATICS AND COMPUTING↗

Design of an on-board checkout system.

Onboard Checkout System /OCS/ design, considering system selection techniques, design development, equipment, etc, with orientation on OCS design by NASA/MSC

AIRBORNE EQUIPMENT↗

Major RFI conditions effecting TDRSS

An evaluation of the radio frequency interference (RFI) conditions which would affect operating frequency band selections and data communications equipment design approaches for the Tracking Data Relay Satellite System (TDRSS) is presented. The subjects discussed are: (1) the scope of the investigation, (2) relative RFI in the frequency bands considered, (3) radar RFI power and duty factor, (4) radio relay communications RFI, (5) radio frequency band usage recommendations, and (6) radar RFI impact areas.

Lyttle, J. D.↗

Medical evaluations on the KC-135 1990 flight report summary

The medical investigations completed on the KC-135 during FY 1990 in support of the development of the Health Maintenance Facility and Medical Operations are discussed. The experiments are comprised of engineering evaluations of medical hardware and medical procedures. The investigating teams are made up of both medical and engineering personnel responsible for the development of medical hardware and medical operations. The hardware evaluated includes dental equipment, a coagulation analyzer, selected pharmaceutical aerosol devices, a prototype air/fluid separator, a prototype packaging and stowage system for medical supplies, a microliter metering system, and a workstation for minor surgical procedures. The results of these engineering evaluations will be used in the design of fleet hardware as well as to identify hardware specific training requirements.

Lloyd, Charles W.↗

Recommended Values of Meteorological Factors to Be Considered in the Design of Aircraft Ice-Prevention Equipment

Meteorological conditions conducive to aircraft icing are arranged in four classifications: three are associated with cloud structure and the fourth with freezing rain. The range of possible meteorological factors for each classification is discussed and specific values recommended for consideration in the design of ice-prevention equipment for aircraft are selected and tabulated. The values selected are based upon a study of the available observational data and theoretical considerations where observations are lacking. Recommendations for future research in the field are presented.

VAPOR, WATER↗