Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Histidine methyltransferase SETD3 methylates structurally diverse histidine mimics in actin

Actin histidine N τ -methylation by histidine methyltransferase SETD3 plays an important role in human biology and diseases. Here, we report integrated synthetic, biocatalytic, biostructural, and computational analyses on human SETD3-catalyzed methylation of actin peptides possessing histidine and its structurally and chemically diverse mimics. Our enzyme assays supported by biostructural analyses demonstrate that SETD3 has a broader substrate scope beyond histidine, including N-nucleophiles on the aromatic and aliphatic side chains. Quantum mechanical/molecular mechanical molecular dynamics and free-energy simulations provide insight into binding geometries and the free energy barrier for the enzymatic methyl transfer to histidine mimics, further supporting experimental data that histidine is the superior SETD3 substrate over its analogs. This work demonstrates that human SETD3 has a potential to catalyze efficient methylation of several histidine mimics, overall providing mechanistic, biocatalytic, and functional insight into actin histidine methylation by SETD3.

59 BASIC BIOLOGICAL SCIENCES↗

Benchmarking Smart Thermostats

Our goal is to compute a set of key performance indicators for commercially available smart thermostats using building energy simulation. If successful, the resulting tool will enable EPA ENERGY STAR and other rating/incentive programs to objectively evaluate new thermostat products.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Multi-Scenario Extreme Weather Simulator

The Multi-scenario Extreme Weather Simulator (MEWS) takes existing historical weather data and inserts trends and extreme events such as heat waves, hurricanes, extreme precipitation, or winter storms. The code includes functionality for projecting increasing frequency and duration of such events over a large range of statistically sampled realizations of the future. These weather files can then be used in building energy simulations through the Energy Plus software created by DOE. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525 SAND2021-8658 O

Villa, Daniel↗

Commercial Building Prototypes Based on ANSI/ASHRAE/IES Standard 90.1-2019 Appendix G PRM: Technical Support Document

The two paths for documenting compliance with ANSI/ASHRAE/IES Standard 90.1 are the prescriptive path and the performance path. Beyond code programs and rating systems (for example, USGBC-LEED ) are primarily known to use a third path – the Appendix G Performance Rating Method. An update in the 2016 edition of Standard 90.1 approved the Appendix G Performance Rating System for code compliance, extending its application and allowing for greater consistency of modeling rules for code and beyond code building energy modeling. The Appendix G PRM provides rules for the development of whole building energy models of baseline and proposed models for calculating the “performance cost index target” value using the simulated energy results of the baseline and proposed models and the building performance factors published in Table 4.2.1.1 of the Standard. This report documents (1) the methodology used for development of the baseline and proposed energy models of the Pacific Northwest National Laboratory and U.S. Department of Energy commercial building prototypes using the Appendix G Performance Rating Method; and (2) the building performance factors that were calculated using those models.

97 MATHEMATICS AND COMPUTING↗

Simulations of Grid-Responsive HVAC Cooling Measures via Ice/PCM storage

This study uses EnergyPlus building energy simulations to assess grid-responsive HVAC cooling measures during peak hours having high electricity price, including: lock the high capacity of a two-speed cooling coil during grid-response hours; and use ice/PCM energy storage to drive a chilled water coil and meet the cooling load, when shut off the main electric cooling coil. Here, the impacts on peak power reductions, energy and utility cost savings, and comfort levels in residential buildings of two U.S. cities were revealed.

Shen, Bo↗

EnergyPlus™ v.23.2.0 2023 [SWR-17-23]

EnergyPlus™ is a whole building energy simulation program that engineers, architects, and researchers use to model both energy consumption and water use in buildings. This is the EnergyPlus Development Repository. The Department of Energy maintains a public website for EnergyPlus where you can find much more information about the program. https://energyplus.net/ For detailed developer information, consult the wiki. https://github.com/NREL/EnergyPlus/wiki Many users (and developers) of EnergyPlus are active on Unmet Hours, so that's a great place to start if you have a question about EnergyPlus or building simulation. https://unmethours.com/questions/ For more in-depth, developer-driven support, please utilize the EnergyPlus Helpdesk. https://energyplushelp.freshdesk.com/support/home

Woods, Jason↗

Retrofitting Buildings with Solar-Reflective Roofs and Walls and its Impact on Peak Power Demand

Buildings are a major consumer of electricity in the United States and a significant portion of the consumption comes from heating, ventilation, and air-conditioning (HVAC) applications. Passive cooling strategies in the building envelope help to reduce the energy consumption for HVAC as well as peak electricity demand. Although being one of the most cost-effective passive cooling strategies, modern reflective roofing and reflective exterior wall technology is not well documented for its impact on peak demand. This study utilized whole building energy simulations on residential and commercial building prototype models to quantify the impact of cool roofs and cool exterior walls. The analysis was performed in three climate zones with varying insulation levels and solar reflectances for roofs and exterior walls. For both the residential and commercial buildings, the baseline building had a roof solar reflectance value of 0.10 and an exterior wall solar reflectance value of 0.25. The results from the simulations show that roofs and exterior walls with higher reflectance values increase cooling energy savings but can also increase heating energy consumption. The impact of changes in solar reflectances was greater in buildings with low roof/wall insulation levels compared to roofs/walls with higher insulation levels. A baseline for the simulations was set with the roof and exterior wall solar reflectances set at 0.1 and 0.25, respectively and simulations having varying roof and exterior wall thermal resistances were compared to the baselines.

14 SOLAR ENERGY↗

Deep quantum circuit simulations of low-energy nuclear states

Numerical simulation is an important method for verifying the quantum circuits used to simulate low-energy nuclear states. However, real-world applications of quantum computing for nuclear theory often generate deep quantum circuits that place demanding memory and processing requirements on conventional simulation methods. Here, we present advances in high-performance numerical simulations of deep quantum circuits to efficiently verify the accuracy of low-energy nuclear physics applications. Our approach employs novel methods for accelerating the numerical simulation including management of simulated mid-circuit measurements to verify projection based state preparation circuits. In this study, we test these methods across a variety of high-performance computing systems and our results show that circuits up to 21 qubits and more than 115,000,000 gates can be efficiently simulated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MCCCS-MN

The MCCCS‒MN (Monte Carlo for Complex Chemical Systems‒Minnesota) software is developed by the Siepmann research group at the University of Minnesota. MCCCS‒MN allows for the simulation of multi-component molecular systems in the canonical, isobaric-isothermal (including constant stress for solids), grand-canonical, semi-grand, and Gibbs (NVT, NPT, and more than two simulation boxes) ensembles. It uses the configurational-bias Monte Carlo method to efficiently sample phase space for linear, branched and cyclic chain molecules, the adiabatic nuclear and electronic sampling Monte Carlo method to treat many-body polarization effects, and the aggregation-volume-bias Monte Carlo algorithm to efficiently sample the spatial distribution of associating molecules. MCCCS-MN employs a molecular representation of the system where force fields contain bonded and non-bonded terms. Funding for the development of MCCCS-MN through grants from the National Science Foundation (simulation of fluid phase equilibria and chromatography) and the Department of Energy (simulation of adsorption equilibria) is gratefully acknowledged.

Siepmann, J.Ilja [University of Minnesota - Twin C↗

Model Energy Codes End-Use Opportunity Analysis

Model energy codes (ASHRAE Standard 90.1 and IECC) has significantly impacted programs and policies aimed at improving energy efficiency both in United States and across the globe. Standard 90.1, first published in 1975 (originally referred to as Standard 90) provides minimum energy efficiency guidelines for designing, constructing, operating, and maintaining new construction and renovated buildings. It is updated continuously, with new editions published every 3 years. Pacific Northwest National Laboratory (PNNL) conducts simulated energy and cost savings analysis of model energy codes to determine their expected impact and to track progress toward net-zero goals and efficiency targets. Additionally, the simulation outputs are examined to assess how energy is used across primary systems within prominent U.S. commercial building types to understand how energy is used in each building type at the end-use level and to identify areas for improvements in future code cycles. This end-use opportunity analysis of model energy codes provides ASHRAE technical committees and other interested parties a better understanding of how the Standard affects various building systems and end uses, specifically, those in the Standard that most prominently influence energy efficiency. Additionally, findings provide industry stakeholders guidance in identifying building types and end-uses with the most potential for energy efficiency improvements through energy codes and those that may require beyond code measures to meet energy use reduction targets. This paper summarizes features and functionalities of a webtool created by PNNL to explore and visualize the End-Use opportunity analysis.

ASHRAE 90.1, Energy Codes, Tableau↗

Achieving 50% Energy Savings in Chicago Homes: A Case Study for Advancing Equity and Climate Goals

Since 2019, the National Renewable Energy Laboratory (NREL) and Elevate have collaborated to identify pathways to deep energy retrofits in Chicago's housing stock, document equity implications and co-benefits of this transition, and validate the findings by implementing retrofits in real Chicago homes. This document summarizes our analysis process to model advanced retrofit packages that lead to greater than 50% energy savings in Chicago homes. Based on these findings, we have also developed a roadmap with the City to guide implementation, and are deploying the recommended retrofit packages in real Chicago homes to realize these energy savings. This work was developed in collaboration with two key stakeholders - the City of Chicago and Commonwealth Edison (ComEd) - and funded by the U.S. Department of Energy (DOE). NREL's Residential Buildings team maintains the best-in-class ResStock™ energy model of the U.S. residential building stock. For this work, we calibrated ResStock to Chicago's unique local housing stock to accurately simulate energy use in Chicago homes both for current conditions and with various retrofit scenarios. We simulated a wide range of potential building retrofits covering all aspects of residential energy use and then grouped these into packages based on energy and utility bill savings. ResStock can model diverse building types and housing characteristics, so we're able to observe the range of outcomes that might occur when these upgrades are deployed across the entire housing stock. We can then estimate potential energy savings from an advanced retrofit program on Chicago's housing stock by comparing the modeled energy use before versus after a retrofit. This novel version of ResStock, calibrated to Chicago with data from Elevate, can help City officials, ComEd, and other partners plan for community-scale decarbonization via residential retrofits. Specifically, this work contributes the following project goals: Develop a building retrofit prioritization strategy for Chicago single-family and 2- to 4-unit buildings; Identify neighborhoods and home types that have the highest potential for savings from electrification; and Assess the impact of advanced building retrofits on energy use, utility bills, and CO2 emissions at the city and building level. Although this study is specific to Chicago, its methods and learnings are applicable across the United States. These findings are especially notable for heat pumps and electrification retrofits in cold climates.

building energy modeling↗

Photovoltaic windows cut energy use and CO 2 emissions by 40% in highly glazed buildings

Buildings account for 30% of global energy use. The architectural trend across building sectors is toward more glass despite higher energy use and carbon emissions than opaque cladding alternatives. Numerous window technologies - low-emissivity coatings, triple glazing, dynamic tinting, and the more recently developed photovoltaic glass - have emerged in the last two decades as approaches to reduce building energy. However, a comprehensive understanding of where and how these window technologies can be installed to enable optimal energy savings under different climate conditions remains limited. Here we test window technologies using thousands of macroscale building-energy simulations for different climate zones and building designs to evaluate the associated net energy use and carbon-emissions reduction potential. Novel window technologies, especially photovoltaic windows with high thermal performance, offer energy savings in all climates, ranging from 10,000-40,000 GJ per year over substandard windows for a typical office building, resulting in up to 2,000 tons of annual CO 2 emissions reduction. Highly glazed, net-zero buildings are achievable via photovoltaic windows when combined with careful geometric considerations.

14 SOLAR ENERGY↗

The application of simulation modeling to the cost and performance ranking of solar thermal power plants

Small solar thermal power systems (up to 10 MWe in size) were tested. The solar thermal power plant ranking study was performed to aid in experiment activity and support decisions for the selection of the most appropriate technological approach. The cost and performance were determined for insolation conditions by utilizing the Solar Energy Simulation computer code (SESII). This model optimizes the size of the collector field and energy storage subsystem for given engine generator and energy transport characteristics. The development of the simulation tool, its operation, and the results achieved from the analysis are discussed.

Rosenberg, L. S.↗

The application of simulation modeling to the cost and performance ranking of solar thermal power plants

A computer simulation code was employed to evaluate several generic types of solar power systems (up to 10 MWe). Details of the simulation methodology, and the solar plant concepts are given along with cost and performance results. The Solar Energy Simulation computer code (SESII) was used, which optimizes the size of the collector field and energy storage subsystem for given engine-generator and energy-transport characteristics. Nine plant types were examined which employed combinations of different technology options, such as: distributed or central receivers with one- or two-axis tracking or no tracking; point- or line-focusing concentrator; central or distributed power conversion; Rankin, Brayton, or Stirling thermodynamic cycles; and thermal or electrical storage. Optimal cost curves were plotted as a function of levelized busbar energy cost and annualized plant capacity. Point-focusing distributed receiver systems were found to be most efficient (17-26 percent).

Rosenberg, L. S.↗

Developing occupant archetypes within urban low-income housing: A case study in Mumbai, India

Rapid urbanization pressure and poverty have created a push for affordable housing within the global south. The design of affordable housing can have consequences on the thermal (dis)comfort and behaviour of the occupants, hence requiring an occupant-centric approach to ensure sustainability. This paper investigates occupant behaviour within the urban poor households of Mumbai, India and its impact on their thermal comfort and energy use. This study is a first-of-its-kind attempt to explore the socio-demographic characteristics and energy-related behaviour of low-income occupants within Indian context. Three occupant archetypes, Indifferent Consumers; Considerate Savers; and Conscious Conventionals, were identified from the behavioural and psychographic characteristics gathered through a transverse field survey. A two-step clustering approach was adopted for occupant segmentation that highlighted considerable diversity in occupants’ adaptation measures, energy knowledge, energy habits, and their pro-environmental behaviour within similar socio-economic group. Building energy simulation of the representative archetype behaviour estimated up to 37% variations for air-conditioned and up to 8% variation for fan-assisted naturally ventilated housing units during peak summer months. The results from this study establish the significance of occupant factors in shaping energy demand and thermal comfort within low-income housing and pave way for developing occupant-centric building design strategies to serve this marginalized population. The developed low-income occupant archetypes would be useful for architects and energy modelers to generate realistic energy use profiles and improve building performance simulation results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Basin-Scale Assessment of the Land Surface Energy Budget in the National Centers for Environmental Prediction Operational and Research NLDAS-2 Systems

This paper compares the annual and monthly components of the simulated energy budget from the North American Land Data Assimilation System phase 2 (NLDAS-2) with reference products over the domains of the 12 River Forecast Centers (RFCs) of the continental United States (CONUS). The simulations are calculated from both operational and research versions of NLDAS-2. The reference radiation components are obtained from the National Aeronautics and Space Administration Surface Radiation Budget product. The reference sensible and latent heat fluxes are obtained from a multitree ensemble method applied to gridded FLUXNET data from the Max Planck Institute, Germany. As these references are obtained from different data sources, they cannot fully close the energy budget, although the range of closure error is less than 15%formean annual results. The analysis here demonstrates the usefulness of basin-scale surface energy budget analysis for evaluating model skill and deficiencies. The operational (i.e., Noah, Mosaic, and VIC) and research (i.e., Noah-I and VIC4.0.5) NLDAS-2 land surface models exhibit similarities and differences in depicting basin-averaged energy components. For example, the energy components of the five models have similar seasonal cycles, but with different magnitudes. Generally, Noah and VIC overestimate (underestimate) sensible (latent) heat flux over several RFCs of the eastern CONUS. In contrast, Mosaic underestimates (overestimates) sensible (latent) heat flux over almost all 12 RFCs. The research Noah-I and VIC4.0.5 versions show moderate-to-large improvements (basin and model dependent) relative to their operational versions, which indicates likely pathways for future improvements in the operational NLDAS-2 system.

Energy↗

Design Heating and Cooling Load Calculation Versus Building Load Simulation for Cold Climate Heat Pumps: Understanding the "Gap"

This report explores the differences between Manual J-equivalent block load calculations and building HVAC energy simulation results using EnergyPlus™ calculations when designing cold climate heat pump systems for residential use. This study will help HVAC researchers and advanced designers understand the impacts of oversizing heat pumps on home energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance assessment of active insulation systems in residential buildings for energy savings and peak demand reduction

Active insulation systems (AISs) in buildings are envelopes that integrate thermal insulation, thermal energy storage, and controls. Although different designs for AISs have been proposed in the literature, a comprehensive analysis of feasible AISs is lacking. This paper discusses the energy performance, peak demand reduction potential, and performance characteristics of an AIS that uses a concrete wall as thermal mass sandwiched between two solid-state thermal switches (STSs). These STSs change their thermal conductivity using an on/off metal switch to create or break a thermal bridge across the STS. This paper first describes the experimental setup, used to determine the ratio of thermal resistance during R-high (low thermal conductivity) and R-low (high thermal conductivity) states of the STSs. This ratio was then used in whole-building energy simulations to evaluate the performance of AIS walls across different climate zones with/without a freeze timer of 60 min. The timer was added to reduce the number of switches of STSs from one state to another, and hence the energy needed for these switches. Analysis of the switching frequency and interval of STSs, thermal conductivity of walls, impact of wall orientation, and heat transfer through the wall from the use of AIS at different climate zones/locations were performed. The simulation results show that the AIS can achieve energy savings ranging from ~980 to 2,290 kWh in a single-family home with a floor area of ~220 m 2 compared with an IECC 2018 baseline. We found the energy savings was higher in dry climate zones which represent 17% of residential buildings in the United States, compared to humid or marine climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗