Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗

Advanced CCD imager technology for use from 1 to 10,000 A

A low-noise, high-sensitivity charge-coupled-device (CCD) technology for imaging applications extending from the soft X-ray (1 A) to the near-infrared (10,000 A) regimes was developed together with a fabrication technology for making back-illuminated versions of these devices with quantum efficiencies as high as 90 percent from 5000 to 7000 A. The efforts have focused on two devices, a 64 x 64 pixel back-illuminated imager with two output ports that operates at 2000 frames per second with 23 electrons read noise, and a larger device, with 420 x 420 pixel format, designed for lower frame rates with noise as low as 1.5 electrons and used at visible, UV, and X-ray wavelengths. Applications to plasma diagnostics include Thomson scattering and high-frame-rate imaging in the visible, as well as X-ray imaging and bolometry.

Twichell, J. C.↗

Implementation of Johnson Noise Thermometry into Radiation Hardened Electronics

The random motion of charge carriers in an electrical conductor is a function of its temperature. This phenomenon generates an electrical signal, referred to as Johnson noise, that is present in all analog signals. Conversely, the temperature dependence of the Johnson noise spectrum also enables a direct measurement of absolute temperature, which can provide a secondary measurement of temperature when quantified using sensors such as resistive temperature devices (RTDs) in a process called Johnson noise thermometry (JNT). For nuclear environments, this is of particular interest in correcting for RTDs signal drift caused by accumulation, transmutation, and displacement damage caused by neutron and gamma irradiation.

42 ENGINEERING↗

DarkNESS: A skipper-CCD NanoSatellite for Dark Matter Searches

The Dark matter Nanosatellite Equipped with Skipper Sensors (DarkNESS) deploys a recently developed skipper-CCD architecture with sub-electron readout noise in low Earth orbit (LEO) to investigate potential signatures of dark matter (DM). The mission addresses two interaction channels: electron recoils from strongly interacting sub-GeV DM and X-rays produced through decaying DM. Orbital observations avoid attenuation that limits ground-based measurements, extending sensitivity reach for both channels. The mission proceeds toward launch following laboratory validation of the instrument. A launch opportunity has been secured through Firefly Aerospace's DREAM 2.0 program, awarded to the University of Illinois Urbana-Champaign (UIUC). This will constitute the first use of skipper-CCDs in space and evaluate their suitability for low-noise X-ray and single-photon detection in future space observatories.

Alpine, Phoenix [Illinois U., Urbana (main)] (ORCI↗

DarkNESS: A skipper-CCD nanosatellite for dark matter searches

The Dark matter Nanosatellite Equipped with Skipper Sensors (DarkNESS) deploys a recently developed skipper-CCD architecture with sub-electron readout noise in low Earth orbit (LEO) to investigate potential signatures of dark matter (DM). The mission addresses two interaction channels: electron recoils from strongly interacting sub-GeV DM and X-rays produced through decaying DM. Orbital observations avoid attenuation that limits ground-based measurements, extending sensitivity reach for both channels. The mission proceeds toward launch following laboratory validation of the instrument. A launch opportunity has been secured through Firefly Aerospace’s DREAM 2.0 program, awarded to the University of Illinois Urbana-Champaign (UIUC). As a result, this will constitute the first use of skipper-CCDs in space and evaluate their suitability for low-noise X-ray and single-photon detection in future space observatories.

Alpine, Phoenix [University of Illinois, Urbana-Ch↗

A Comparison of ARTEMIS Observations and Particle-in-cell Modeling of the Lunar Photoelectron Sheath in the Terrestrial Magnetotail

As an airless body in space with no global magnetic field, the Moon is exposed to both solar ultraviolet radiation and ambient plasmas. Photoemission from solar UV radiation and collection of ambient plasma are typically opposing charging currents and simple charging current balance predicts that the lunar dayside surface should charge positively; however, the two ARTEMIS probes have observed energydependent loss cones and high-energy, surface-originating electron beams above the dayside lunar surface for extended periods in the magnetosphere, which are indicative of negative surface potentials. In this paper, we compare observations by the ARTEMIS P1 spacecraft with a one dimensional particle-in-cell simulation and show that the energy-dependent loss cones and electron beams are due to the presence of stable, non-monotonic, negative potentials above the lunar surface. The simulations also show that while the magnitude of the non-monotonic potential is mainly driven by the incoming electron temperature, the incoming ion temperature can alter this magnitude, especially for periods in the plasma sheet when the ion temperature is more than twenty times the electron temperature. Finally, we note several other plasma phenomena associated with these non-monotonic potentials, such as broadband electrostatic noise and electron cyclotron harmonic emissions, and offer possible generation mechanisms for these phenomena.

Lunar↗

Achieving Single-Electron Sensitivity at Enhanced Speed in Fully-Depleted CCDs with Double-Gate MOSFETs

We introduce a new output amplifier for fully-depleted thick p-channel CCDs based on double-gate MOSFETs. The charge amplifier is an n-type MOSFET specifically designed and operated to couple the fully-depleted CCD with high charge-transfer efficiency. The junction coupling between the CCD and MOSFET channels has enabled high sensitivity, demonstrating sub-electron readout noise in one pixel charge measurement. We have also demonstrated the non-destructive readout capability of the device. Achieving single-electron and single-photon per pixel counting in the entire CCD pixel array has been made possible through the averaging of a small number of samples. We have demonstrated fully-depleted CCD readout with better performance than the floating diffusion and floating gate amplifiers available today, in both single and multisampling regimes, boasting at least six times the speed of floating gate amplifiers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplexed Readout for an Experiment with a Large Number of Channels Using Single-Electron Sensitivity Skipper-CCDs

This paper presents the implementation of a multiplexed analog readout electronics system that can achieve single-electron counting using Skipper-CCDs with non-destructive readout. The proposed system allows the best performance of the sensors to be maintained, with sub-electron noise-level operation, while maintaining low-bandwidth data transfer, a minimum number of analog-to-digital converters (ADC) and low disk storage requirement with zero added multiplexing time, even for the simultaneous operation of thousands of channels. These features are possible with a combination of analog charge pile-up, sample and hold circuits and analog multiplexing. The implementation also aims to use the minimum number of components in circuits to keep compatibility with high-channel-density experiments using Skipper-CCDs for low-threshold particle detection applications. Performance details and experimental results using a sensor with 16 output stages are presented along with a review of the circuit design considerations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A model for chorus associated electrostatic bursts

The linear theory of the generation of electrostatic bursts of noise by electrons trapped in chorus wave packets is developed for a finite temperature electron beam and a Maxwellian elecron and ion background. The growth rates determined qualitatively in good agreement with those obtained by previous authors from a more idealized model. Two connected instability mechanisms seem to be occurring: a beam plasma (electron-ion two-stream) instability commonly associated with intensification of the chorus power levels, and a transitional or borderline resistive medium instability commonly associated with chorus hooks. The physical reasons for the two mechanisms is discussed. In the second case electron beams are difficult to identify in the particle data. An expression is obtained for the maximum growth rate in terms of the ratios of the beam and electron thermal velocities to the beam velocity, and of the beam density to plasma density. It is anticipated that this may allow the observed peak in the electrostatic noise spectrum to be used as a diagnostic for the beam characteristics. Previously announced in STAR as N84-12832

Grabbe, C. L.↗

Investigation of Density Fluctuations in Supersonic Free Jets and Correlation with Generated Noise

The air density fluctuations in the plumes of fully-expanded, unheated free jets were investigated experimentally using a Rayleigh scattering based technique. The point measuring technique used a continuous wave laser, fiber-optic transmission and photon counting electronics. The radial and centerline profiles of time-averaged density and root-mean-square density fluctuation provided a comparative description of jet growth. To measure density fluctuation spectra a two-Photomultiplier tube technique was used. Crosscorrelation between the two PMT signals significantly reduced electronic shot noise contribution. Turbulent density fluctuations occurring up to a Strouhal number (Sr) of 2.5 were resolved. A remarkable feature of density spectra, obtained from the same locations of jets in 0.5< M<1.5 range, is a constant Strouhal frequency for peak fluctuations. A detailed survey at Mach numbers M = 0.95, 1.4 and 1.8 showed that, in general, distribution of various Strouhal frequency fluctuations remained similar for the three jets. In spite of the similarity in the flow fluctuation the noise characteristics were found to be significantly different. Spark schlieren photographs and near field microphone measurements confirmed that the eddy Mach wave radiation was present in Mach 1.8 jet, and was absent in Mach 0.95 jet. To measure correlation between the flow and the far field sound pressure fluctuations, a microphone was kept at a distance of 50 diameters, 30 deg. to the flow direction, and the laser probe volume was moved from point to point in the flow. The density fluctuations in the peripheral shear layer of Mach 1.8 jet showed significant correlation up to the measurement limit of Sr = 2.5, while for Mach 0.95 jet no correlation was measured. Along the centerline measurable correlation was found from the end of the potential core and at the low frequency range (Sr less than 0.5). Usually the normalized correlation values increased with an increase of the jet Mach number. The experimental data point out eddy Mach waves as a strong source of sound generation in supersonic jets and fail to locate the primary noise mechanism in subsonic jets.

Panda, J.↗

HgCdTe 256x256 NWIR FPA

Researchers developed a HgCdTe 256x256 focal plane array (FPA) which operates in the 1 to 5 micron band. This is presently the largest demonstrated HgCdTe FPA. The detector material is HgCdTe on sapphire (PACE-1 technology) which has a low thermal expansion mismatch with silicon. The multiplexer is a CMOS FET-switch device processed through a commercial silicon foundry. The multiplexer input is direct injection and the charge capacity is about 2 times 10 to the 7th power electrons. The kTC limited read noise is 400 electrons. Researchers demonstrated high background imaging using the device. The broadband quantum efficiency is measured to be 59 percent. Dark currents less than 0.1 pA were measured at 77 K for detectors processed on PACE-1 material with 4.9 microns cutoff. The dark currents decrease as the temperature is lowered, and researchers are presently studying the T less than 77 K characteristics. The interconnect yield is greater than 95 percent. The devices are available for astronomical applications.

Vural, Kadri↗

Sensing performance of sub-100-nm vanadium oxide films for room temperature thermal detection applications

Vanadium oxide films are widely employed as thermal detectors in uncooled infrared detection systems due to their high temperature coefficient of resistance near room temperature. One strategy toward maximizing detectivity and reducing the thermal time constant in these systems is to minimize the system platform dimensions. This approach necessitates thinner film thicknesses ([Formula: see text]100 nm), for which there is little information regarding thermal sensing performance. Herein, we report on the sensitivity of reactively sputtered vanadium oxide thin film resistive thermometers nominally ranging from 100 to 25 nm and assess the influence of thermal annealing. Here we demonstrate that films in this minimum limit of thickness maintain a high temperature coefficient while additionally providing an enhancement in characteristics of the noise equivalent power.

36 MATERIALS SCIENCE↗

On the Characterization and Mitigation of Noise in Space-borne Microwave Sounding Instruments

Space-borne microwave sounding instruments have become vital data sources for weather prediction and climate change studies. Among the various radiometer configurations, the total power microwave radiometer is particularly appealing for current and future operational satellites due to its superior sensitivity and simple design. However, its performance is vulnerable to degradation caused by receiver gain fluctuations, electronic 1/f noise, and other time varying receiver characteristics. For Numerical Weather Prediction (NWP) users, 1/f noise introduces inter-channel correlations, complicating the assimilation of affected observations and reducing their accuracy. Addressing this noise issue in ground data processing system is essential to enhance the utility of microwave sounding data. This paper focuses on the characterization and mitigation of noise in current and future microwave sounding instruments, with particular emphasis on the impact of 1/f noise. Various methods are applied to quantitatively characterize noise features in both frequency and time domains. Additionally, the influence of calibration parameters on 1/f noise are analyzed. Based on these findings, we propose a mitigation algorithm for reducing noise during the on-orbit calibration of microwave sounding instruments, aiming to improve the quality of retrieved data for operational use.

calibration↗

Multidimensional four-wave-mixing spectroscopy with squeezed light

A set of nonlinear spectroscopic measurements with quantum light is presented here. It involves a strong pump with frequency ω pu and a weak probe atω pr interacting with a solid state target to generate a conjugated beam ω c =2ω pu -ω pr via nondegenerate four-wave mixing. The $\chi^{(3)}$ susceptibility can be measured by the noise spectra of the intensity difference of the squeezed beams. We discuss three spectroscopic setups based on squeezed light: first, single four-wave mixing in a single crystal; second, cascading scheme involving two crystals; third, an $\textit{SU}$(1, 1) interferometer based on two separate four-wave mixing processes. We further investigate the microscopic noise and optical losses in all three setups. Simulations are presented for silicon-vacancy color centers in diamond.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Novel 2D velocity estimation method for large transient events in plasmas

Dynamics of fast transient events are challenging to be analyzed with high time resolution. Such events can occur in fusion plasmas such as the filaments during edge-localized modes (ELMs). Here, we present a robust method—the spatial displacement estimation—for estimating the displacements of structures with fast dynamics from high spatial and time resolution imaging diagnostics [e.g., gas-puff imaging (GPI)] with sampling time temporal resolution. First, a background suppression method is shown, which suppresses the slowly time-evolving and spatially non-uniform background in the signal. In the second step, a two-dimensional polynomial trend subtraction method is presented to tackle the remaining polynomial order trend in the signal. After performing these pre-processing steps, the spatial displacement of the propagating structure is estimated from the two-dimensional spatial cross-correlation coefficient function calculated between consecutive frames. The method is tested for its robustness and accuracy by simulated Gaussian events and spatially displaced random noise. An example application of the method is presented on propagating ELM filaments measured by the GPI system on the National Spherical Torus Experiment spherical tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-frequency noise characteristics of GaN vertical PIN diodes—Effects of design, current, and temperature

We report low-frequency noise characteristics of vertical GaN PIN diodes, focusing on the effects of the diode design, current, and temperature. The as-grown and regrown diodes, with and without surface treatment, have been studied. The noise in most of the GaN devices had a characteristic 1/f spectrum at high and moderate currents, while some devices revealed generation-recombination bulges at low currents (f is the frequency). The predominant trend of the noise spectral density, S I , dependence on the current was S I ~ I. All tested GaN PIN diodes had rather low normalized noise spectral densities of 10 –18 –10 –16 cm 2 /Hz (f = 10 Hz) at the current density J = 1 A/cm 2 at room temperature. The noise temperature dependences at different currents revealed peaks at T = 375–400 K. Temperature, current, and frequency dependences of noise suggest that the noise mechanism is of the recombination origin. Here, we argue that the noise measurements at low currents can be used to efficiently assess the quality of GaN PIN diodes.

36 MATERIALS SCIENCE↗