Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic filters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Tangential extreme ultraviolet and soft x-ray diagnostic system for time-resolved temperature measurement on the High Beta Tokamak-Extended Pulse

The High Beta Tokamak-Extended Pulse has recently incorporated a tangential multi-energy extreme ultraviolet and soft x-ray diagnostic system. This system enables measurements of the electron temperature and the examination of mode dynamics within the tokamak. While other systems have been built for poloidal views over similar temperature ranges, this is the first multi-energy tangential-view system designed to work in a temperature range below 200 eV in a tokamak. To facilitate these measurements, a filter wheel comprising five distinct groups of dual-filters has been developed and implemented. By employing a combination of 0.1 μm aluminum and 0.2 μm titanium filters, the system allows estimation of electron temperature profiles through reconstruction of the emission profile using the standard “double-foil” technique. The influence of impurities and filter oxide layers on measurement outcomes is examined. Results reveal that, while the absolute electron temperature values may exhibit some deviations, key characteristics like the electron temperature profile shape and inversion radius during sawtooth events remain consistent. This consistency confirms the system’s suitability for core plasma studies. This system has proven effective in detecting and analyzing internal magnetohydrodynamic phenomena, such as sawteeth.

Instruments & Instrumentation↗

A New Approach to Identify Optimal Properties of Shunting Elements for Maximum Damping of Structural Vibration Using Piezoelectric Patches

The use of shunted piezoelectric patches in reducing vibration and sound radiation of structures has several advantages over passive viscoelastic elements, e.g., lower weight with increased controllability. The performance of the piezoelectric patches depends on the shunting electronics that are designed to dissipate vibration energy through a resistive element. In past efforts most of the proposed tuning methods were based on modal properties of the structure. In these cases, the tuning applies only to one mode of interest and maximum tuning is limited to invariant points when based on den Hartog's invariant points concept. In this study, a design method based on the wave propagation approach is proposed. Optimal tuning is investigated depending on the dynamic and geometric properties that include effects from boundary conditions and position of the shunted piezoelectric patch relative to the structure. Active filters are proposed as shunting electronics to implement the tuning criteria. The developed tuning methods resulted in superior capabilities in minimizing structural vibration and noise radiation compared to other tuning methods. The tuned circuits are relatively insensitive to changes in modal properties and boundary conditions, and can applied to frequency ranges in which multiple modes have effects.

Park, Junhong↗

High-Resolution Electron Energy-Loss Spectroscopy (HREELS) Using a Monochromated TEM/STEM

A 200 keV FEI TF20 XT monochromated (scanning) transmission electron microscope funded by NASA's SRLIDAP program is undergoing installation at Lawrence Livermore National Laboratory. Instrument specifications in STEM mode are Cs =1.0 mm, Cc =1.2 mm, image resolution =0.18 nm, and in TEM mode Cs =1.3 mm, Cc =1.3 mm, information limit =0.14 nm. Key features of the instrument are a voltage-stabilized high tension (HT) supply, a monochromator, a high-resolution electron energy-loss spectrometer/energy filter, a high-resolution annular darkfield detector, and a solid-state x-ray energy-dispersive spectrometer. The high-tension tank contains additional sections for 60Hz and high frequency filtering, resulting in an operating voltage of 200 kV plus or minus 0.005V, a greater than 10-fold improvement over earlier systems. The monochromator is a single Wien filter design. The energy filter is a Gatan model 866 Tridiem-ERS high resolution GIF spec d for less than or equal to 0.15 eV energy resolution with 29 pA of current in a 2 nm diameter probe. 0.13 eV has already been achieved during early installation. The x-ray detector (EDAX/Genesis 4000) has a take-off angle of 20 degrees, an active area of 30 square millimeters, and a solid angle of 0.3 steradians. The higher solid angle is possible because the objective pole-piece allows the detector to be positioned as close as 9.47 mm from the specimen. The voltage-stabilized HT supply, monochromator and GIF enable high-resolution electron energy-loss spectroscopy (HREELS) with energy resolution comparable to synchrotron XANES, but with approximately 100X better spatial resolution. The region between 0 and 100 eV is called the low-loss or valence electron energy-loss spectroscopy (VEELS) region where features due to collective plasma oscillations and single electron transitions of valence electrons are observed. Most of the low-loss VEELS features we are detecting are being observed for the first time in IDPs. A major focus of our research is to understand the origin and significance of these features and how they might be exploited to gain insight about IDPs and other meteoritic materials.

Sai, Z. R.↗

Enhanced thermoelectric efficiency in nanocrystalline bismuth telluride nanotubes

We report on the thermal and thermoelectric properties of individual nanocrystalline Bi 2 Te 3 nanotubes synthesized by the solution phase method using 3ω method and a microfabricated testbench. Measurements show that the nanotubes offer improved ZT compared to bulk Bi 2 Te 3 near room temperature due to an enhanced Seebeck coefficient and suppressed thermal conductivity. This improvement in ZT originates from the nanocrystalline nature and low dimensionality of the nanotubes. Domain boundary filtering of low-energy electrons provides an enhanced Seebeck coefficient. The scattering of phonons at the surface of the nanotube leads to suppressed thermal conductivity. These have been theoretically analyzed using the Boltzmann equation based on the relaxation time approximation and Landauer approach. This work clearly demonstrates the possibility of achieving enhancement in thermoelectric efficiency by combining nanocrystalline and low-dimensional systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Role of structural defects in mediating disordering processes at irradiated epitaxial Fe 3 O 4 / Cr 2 O 3 interfaces

Disordering processes in oxide materials are complicated by the presence of interfaces, which can serve as either point defect sinks or accumulation sites; the response depends on factors such as interfacial structure, chemistry, and termination. Here, we have characterized the disordering of epitaxial Fe 3 O 4 (111) / Cr 2 O 3 (0001) thin film heterostructures after 400 keV Ar 2+ radiation at room temperature. The density of misfit dislocations in both the Fe 3 O 4 overlayer and Cr 2 O 3 buffer layer is varied by changing the thickness of Cr 2 O 3 to be pseudomorphically strained to the Al 2 O 3 (0001) substrate (5 nm thick) or partially relaxed (20 nm thick), as confirmed by Bragg filtering analysis of scanning transmission electron microscopy images. In both cases, irradiation leads to damage accumulation on the Fe 3 O 4 side of the heterointerface, as shown by Rutherford backscattering spectrometry measurements in the channeling geometry. However, the interface with more misfit dislocations exhibits disordering at a faster rate than the less-defective interface. Likewise, layer-resolved electron energy loss spectroscopy reveals interfacial reduction of Fe after irradiation at the more defective interface. Intermixing of Cr across the interface is observed by atom probe tomography, which is likely facilitated by the generation of Cr interstitials in Cr 2 O 3 under irradiation.

36 MATERIALS SCIENCE↗

Aerosol-Assisted Deposition for TiO 2 Immobilization on Photocatalytic Fibrous Filters for VOC Degradation

Atomization and spraying are well-established methods for the production of submicrometer- and micrometer- sized powders. In addition, they could be of interest to the immobilization of photocatalytic nanoparticles onto supports because they enable the formation of microporous films with photocatalytic activity. Here, we provide a comparison of aerosol-assisted immobilization methods, such as spray-drying (SD), spray atomization (SA), and spray gun (SG), which were used for the deposition of TiO 2 dispersions onto fibrous filter media. The morphology, microstructure, and electronic properties of the structures with deposited TiO 2 were characterized by SEM and TEM, BET and USAXS, and UV-Vis spectrometry, respectively. The photocatalytic performances of the functionalized filters were evaluated and compared to the benchmark dip-coating method. Our results showed that the SG and SA immobilization methods led to the best photocatalytic and operational performance for the degradation of toluene, whereas the SD method showed the lowest degradation efficiency and poor stability of coating. We demonstrated that TiO2 sprays using the SG and SA methods with direct deposition onto filter media involving dispersed colloidal droplets revealed to be promising alternatives to the dip-coating method owing to the ability to uniformly cover the filter fibers. In addition, the SA method allowed for fast and simple control of the coating thickness as the dispersed particles were continuously directed onto the filter media without the need for repetitive coatings, which is common for the SG and dip-coating methods. Our study highlighted the importance of the proper immobilization method for the efficient photocatalytic degradation of VOCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design, fabrication and performance of two grazing incidence telescopes for celestial extreme ultraviolet astronomy

The design and performance of grazing incidence telescopes for celestial extreme ultraviolet (EUV) astronomy are described. The telescopes basically consist of a star tracker, collimator, grazing incidence mirror, vacuum box lid, vacuum housing, filters, a ranicon detector, an electronics box, and an aspect camera. For the survey mirror a Wolter-Schwarzschild type II configuration was selected. Diamond-turning was used for mirror fabrication, a technique which machines surfaces to the order of 10 microns over the required dimensions. The design of the EUV spectrometer is discussed with particular reference to the optics for a primarily spectroscopic application and the fabrication of the f/10 optics.

Lampton, M.↗

An incursion of dust in the southwestern United States from April 1980 eruptions of Mount St. Helens

An intrusion of volcanic dust occurred over the northern Mojave Desert, one month before the explosive eruption of 18 May 1980. Visibility was reduced to 15 to 30 miles during meteorological conditions that should have yielded a visibility in excess of 100 miles. This intrusion was documented by particle size distributions, scanning electron microscope analysis of Nuclepore filter samples, insolation measurements, observations by Navy and NASA aircraft, and meteorological data. No further incidents have been observed to date because of a lack of simultaneous volcanic activity with the particular wind patterns that existed in April. Therefore, under certain meteorological conditions, the desert of the southwestern United States could be significantly affected by volcanic ash from an eruption of Mount St. Helens.

Mathews, L. A.↗

An astronomy camera for low background applications in the 1.0 to 2.5 micron spectral region

A description is given of a low-background astronomy camera system based on a short wavelength (1.0-2.5 micron) 128 x 128 focal plane array. The camera is designed to accept either a HgCdTe array for the 1-2.5 micron spectral region or an InSb array for the 3-5 micron spectral region. A cryogenic folded optical system is utilized to control excess stray light along with a cold eight-position filter wheel for spectral filtering. The camera head and electronics will also accept a 256 x 256 focal plane. Engineering evaluation of the system and two engineering runs at the JPL Table Mountain Observatory have been completed. System design, engineering performance, and sample imagery are presented.

Kaki, Said A.↗

Fiber-optic three axis magnetometer prototype development

The goal of this research program was to develop a high sensitivity, fiber optic, interferometric, three-axis magnetometer for interplanetary spacecraft applications. Dynamics Technology, Inc. (DTI) has successfully integrated a low noise, high bandwidth interferometer with high sensitivity metallic glass transducers. Also, DTI has developed sophisticated signal processing electronics and complete data acquisition, filtering, and display software. The sensor was packaged in a compact, low power and weight unit which facilitates deployment. The magnetic field sensor had subgamma sensitivity and a dynamic range of 10(exp 5) gamma in a 10 Hz bandwidth. Furthermore, the vector instrument exhibited the lowest noise level when only one axis was in operation. A system noise level of 1 gamma rms was observed in a 1 Hz bandwidth. However, with the other two channels operating, the noise level increased by about one order of magnitude. Higher system noise was attributed to cross-channel interference among the dither fields.

Wang, Thomas D.↗

Yohkoh/SXT x-ray synoptic maps of coronal brightness and temperature

The Yohkoh soft X-ray telescope (SXT) records on the order of 50 solar images per day in two different color filters. These provide material for the generation of synoptic maps, which compress the 3-dimensional data cube into two dimensions. We are creating synoptic maps from strips of data both at disk center and at different heights, including limb maps that are analogous to those produced by ground-based coronagraphs. The ratios of intensities in images taken in two filters provide estimates of the electron temperature in the range 1 - 3 x 10(exp 6) K. These are broad-band temperature maps; rather than maps created with discrete sampling as in the case of the coronal green and red lines. We discuss the properties of these maps and their application to the study of energy release in the corona.

Slater, G. L.↗

A Second Generation Multi-Angle Imaging SpectroRadiometer (MISR-2)

The Multi-angle Imaging SpectroRadiometer (MISR) has been in Earth orbit since December 1999 on NASA's Terra spacecraft. This instrument provides new ways of looking at the Earth's atmosphere, clouds, and surface for the purpose of understanding the Earth's ecology, environment, and climate. To facilitate the potential future continuation of MISR's multi-angle observations, a study was undertaken in 1999 and 2000 under the Instrument Incubator Program (IIP) of NASA Code Y's Earth Science Technology Office (ESTO) to investigate and demonstrate the feasibility of a successor to MISR that will have greatly reduced size and mass. The kernel of the program was the design, construction, and testing of a highly miniaturized camera, one of the nine that would probably be used on a future space borne MISR-like instrument. This demonstrated that the size and mass reduction of the optical system and camera electronics are possible and that filters can be assembled to meet the miniaturized packaging requirements. An innovative, reflective optics design was used, enabling the wavelength range to be extended into the shortwave infrared. This was the smallest all-reflective camera ever produced by the contractor. A study was undertaken to determine the feasibility of implementing nine (multi-angle) cameras within a single structure. This resulted in several possible configurations. It would also be possible to incorporate one of the cameras into an airborne instrument.

spectroradiometers↗

Single sensor processing to obtain high resolution color component signals

A method for generating color video signals representative of color images of a scene includes the following steps: focusing light from the scene on an electronic image sensor via a filter having a tri-color filter pattern; producing, from outputs of the sensor, first and second relatively low resolution luminance signals; producing, from outputs of the sensor, a relatively high resolution luminance signal; producing, from a ratio of the relatively high resolution luminance signal to the first relatively low resolution luminance signal, a high band luminance component signal; producing, from outputs of the sensor, relatively low resolution color component signals; and combining each of the relatively low resolution color component signals with the high band luminance component signal to obtain relatively high resolution color component signals.

Glenn, William E.↗

Predicting the Blast of Lunar Soil Under a Rocket's Exhaust Jet

The blast of lunar soil represents a problem for the future missions planned for the moon. When the lander approached the ground during the Apollo missions, huge showers of dust particles were sent in all directions at extremely high velocities - including upwards towards the landing spacecraft. This represents a clear danger to the lander because the loss of visibility and the damage that can be produced to the vehicle itself. If there had been equipment on the ground, these showers of particles would have created a sand blasting effect over the equipment, possibly damaging optics and contaminating the equipment and depending on the size and velocity of the particles maybe even more extensive damage as the particles penetrated the outer surface of the equipment. Since the there is no air on the moon to slow down the particles, they can travel large distances at high speeds, in fact in some instances they can reach near escape velocity and go into an orbit around the moon and come all the way back to almost the same point where they were at the beginning; meaning that some of the lunar dust that came up during landing will shower back over the site. Once on the surface, the extremely fine dust had a habit of getting itself everywhere. During the Apollo missions it not only covered the astronauts' suits, but managed to work its way inside, damaging airtight joints and scratching up glass visors. The dust found its way inside the spacecraft, contaminating the floor and electronic systems inside, clogging air filters in the process. This is due to the fact that the lunar soil is extremely cohesive. The Lunar soil causes all of the same problems as sand does on Earth but unlike sand particles on Earth, which have smooth spherical shapes, the dust on the Moon is more like small particles of glass with sharper edges since there is no erosion on the lunar surface. During the Apollo missions the dust problem did not cause a big problem due to the fact of the length of duration of the missions. But as NASA plans to have long term missions to the moon the dust problem becomes an issue, due to multiple landings and the equipment that will be accumulated on the site. In order to mitigate these problems it is needed first to understand the physics of the problem in order to find the most suitable solution to protect equipment and vehicles during the next lunar missions..

Diaz, Carlos J. Sanchez↗

Progress in the Development of Frequency-Domain Multiplexing for the X-ray Integral Field Unit on Board the Athena Mission

Frequency-domain multiplexing (FDM) is the baseline readout system for the X-ray Integral Field Unit on board the Athena mission. Under the FDM scheme, TESs are coupled to a passive LC filter and biased with alternating current (AC bias) at MHz frequencies. Using high-quality-factor LC filters and room-temperature electronics developed at SRON and low-noise two-stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. We have achieved a performance requested for the demonstration model with the single-pixel AC bias ( ΔE = 1.8 eV ) and nine-pixel multiplexing ( ΔE = 2.6 eV ) modes. We have also demonstrated 14-pixel multiplexing with an average energy resolution of 3.3 eV, which is limited by nonfundamental issues related to FDM readout in our laboratory setup.

H. Akamatsu↗

Spatial and Temporal Energy Characterization of Precipitating Electrons for the January 10th, 1997 Magnetic Cloud Event

The January 10-11, 1997 magnetic cloud event provided a rare opportunity to study auroral energy deposition under varying but intense IMF conditions. The Wind spacecraft located about 100 RE upstream monitored the IMF and plasma parameters during the passing of the cloud. The Polar Ultraviolet Imager (UVI) observed the aurora[ precipitation during the first encounter of the cloud with Earth's magnetosphere and during several subsequent substorm events. The UVI has the unique capability of measuring the energy flux and characteristic energy of the precipitating electrons through the use of narrow band filters that distinguish short and long wavelength molecular nitrogen emissions. The spatial and temporal characteristics of the precipitating electron energy will be discussed beginning with the inception of the event at the Earth early January 1 Oth and continuing through the subsidence of auroral activity on January 11th.

Spann, J. F., Jr.↗

One dimensional wormhole corrosion in metals

Corrosion is a ubiquitous failure mode of materials. Often, the progression of localized corrosion is accompanied by the evolution of porosity in materials previously reported to be either three-dimensional or two-dimensional. However, using new tools and analysis techniques, we have realized that a more localized form of corrosion, which we call 1D wormhole corrosion, has previously been miscategorized in some situations. Using electron tomography, we show multiple examples of this 1D and percolating morphology. To understand the origin of this mechanism in a Ni-Cr alloy corroded by molten salt, we combined energy-filtered four-dimensional scanning transmission electron microscopy and ab initio density functional theory calculations to develop a vacancy mapping method with nanometer-resolution, identifying a remarkably high vacancy concentration in the diffusion-induced grain boundary migration zone, up to 100 times the equilibrium value at the melting point. Deciphering the origins of 1D corrosion is an important step towards designing structural materials with enhanced corrosion resistance.

36 MATERIALS SCIENCE↗

Atmospheric particulate measurements in Norfolk, Virginia

Characterization of atmospheric particulates was conducted at a site near the center of Norfolk, Virginia. Air quality was measured in terms of atmospheric mass loading, particle size distribution, and particulate elemental composition for a period of 2 weeks. The objectives of this study were (1) to establish a mean level of air quality and deviations about this mean, (2) to ascertain diurnal changes or special events in air quality, and (3) to evaluate instrumentation and sampling schedules. Simultaneous measurements were made with the following instruments: a quartz crystal microbalance particulate monitor, a light-scattering multirange particle counter, a high-volume air sampler, and polycarbonate membrane filters. To assess the impact of meteorological conditions on air quality variations, continuous data on temperature, relative humidity, wind speed, and wind direction were recorded. Particulate elemental composition was obtained from neutron activation and scanning electron microscopy analyses of polycarbonate membrane filter samples. The measured average mass loading agrees reasonably well with the mass loadings determined by the Virginia State Air Pollution Control Board. There are consistent diurnal increases in atmospheric mass loading in the early morning and a sample time resolution of 1/2 hour seems necessary to detect most of the significant events.

Storey, R. W., Jr.↗