Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrolyte”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Carbon dioxide electrolysis using a ceramic electrolyte

This paper discusses the results of an experimental study of the electrical aspects of carbon dioxide electrolysis using a ceramic electrolyte. The electrolyte compositions used in this study are 8% Y2O3 stabilized ZrO2, 7.5% CaO stabilized ZrO2, and 5% Y2O3 stabilized ThO2. Results indicate that the 8% Y2O3 stabilized ZrO2 is the best material to use for electrolysis, in terms of current as a function of voltage and temperature, and in terms of efficiency of oxide ion flow through it. The poorest results were obtained with the 5% Y2O3 stabilized ThO2 composition. An electrolysis system which might be employed to reclaim oxygen and carbon from effluents of space manufacturing, assuming that an industry would have to electrolyze 258,000 tonnes of CO2 per year, is predicted to require a total cell area of 110,000 sq m of 1 mm thickness and electrical capacity of 441 MW.

Erstfeld, T. E.↗

Dedicated nuclear facilities for electrolytic hydrogen production

An advanced technology, fully dedicated nuclear-electrolytic hydrogen production facility is presented. This plant will produce hydrogen and oxygen only and no electrical power will be generated for off-plant use. The conceptual design was based on hydrogen production to fill a pipeline at 1000 psi and a 3000 MW nuclear base, and the base-line facility nuclear-to-shaftpower and shaftpower-to-electricity subsystems, the water treatment subsystem, electricity-to-hydrogen subsystem, hydrogen compression, efficiency, and hydrogen production cost are discussed. The final conceptual design integrates a 3000 MWth high-temperature gas-cooled reactor operating at 980 C helium reactor-out temperature, direct dc electricity generation via acyclic generators, and high-current density, high-pressure electrolyzers based on the solid polymer electrolyte approach. All subsystems are close-coupled and optimally interfaced and pipeline hydrogen is produced at 1000 psi. Hydrogen costs were about half of the conventional nuclear electrolysis process.

Foh, S. E.↗

Apparatus for electrolytically tapered or contoured cavities

An electrolytic machining apparatus for forming tapered or contoured cavities in an electrically conductive and electrochemically erodible piece is presented. It supports the workpiece and an electrode for movement relatively toward each other and has means for pumping an electrolyte between the workpiece and the electrode.

Williams, L. A.↗

Na+ and Ca2+ ingestion - Plasma volume-electrolyte distribution at rest and exercise

The effects of hypernatremia and hypercalcemia on plasma volume and electrolyte distribution during rest, exercise and recovery in cool and hot environments are investigated. Plasma volume, protein and electrolytes were measured in two groups of five men in the supine position during rest, exercise at 40-47% maximal oxygen consumption and recovery in 26.5 C and 39.4 C environments, after ingestion in the rest period of 16-17 ml/kg hypertonic NaCl, isotonic NaCl or hypertonic calcium gluconate solutions. During the rest period, it is found that the hypertonic Ca drink prevents any rise in plasma volume in both cool and hot environments, while hypertonic Na retarded hypervolemia only in the cool environment and consumption of both isotonic and hypertonic Na in the heat resulted in a hypervolemic response twice as great as that in the cool environment. During exercise and recovery, plasma volume is found to be greatest after drinking hypertonic Na in the heat, while the normal hypervolemic responses during exercise were not influenced by drink composition. Results suggest that hypertonic drinks may be better for maintaining plasma volumes during exercise in the heat.

Greenleaf, J. E.↗

Fluid-electrolyte shifts and thermoregulation - Rest and work in heat with head cooling

The effects of head cooling on thermoregulation and associated plasma fluid and electrolyte shifts during rest and submaximal exercise in the heat are investigated. Thermoregulatory responses and plasma volume were measured in four male subjects fitted with liquid-cooled neoprene headgear during 60 min of rest, 60 min of ergometer exercise at 45% maximal oxygen uptake and 30 min of recovery in the supine position at 40.1 C and 40% relative humidity. It is found that, compared to control responses, head cooling decreased thigh sweating and increased mean skin temperature at rest and attenuated increases in thigh sweating, heart rate, rectal temperature and ventilation during exercise. During recovery, cooling is observed to facilitate decreases in sweat rate, heart rate, rectal temperature and forearm blood flow and enhance the increase in average temperature. Cooling had no effect on plasma protein, osmotic or electrolyte shifts, and decreased plasma volume losses. The findings indicate the effectiveness of moderate head cooling for the improvement of human performance during exercise in heat.

Greenleaf, J. E.↗

JSC systems using solid ceramic oxygen electrolyte cells to measure oxygen fugacites in gas-mixing systems

Details are given for the construction and operation of a 101.3 KN/sq meter (1 atmosphere) redox control system. A solid ceramic oxygen electrolyte cell is used to monitor the oxygen fugacity in the furnace. The system consists of a vertical quench gas mixing furnace with heads designed for mounting the electrolyte cell and with facilities for inserting and removing the samples, a simplified version of a gas mixing apparatus, and devices for experiments under controlled rates of change of temperature. A thermogravimetric analysis system employing these techniques of redox control and measurement is also described. The calibration and maintenance of the system are discussed.

Williams, R. J.↗

Performance comparison: Aluminum electrolytic and solid tantalum capacitor

Several key electrical and environmental parameters of latest technology aluminum electrolytic and solid tantalum capacitors were evaluated in terms of price fluctuations of tantalum metal. Performance differences between solid tantalums and aluminum electrolytics are examined.

Hawthornthwaite, B. G.↗

Solid electrolyte cell

A solid electrolyte cell including a body of solid ionized gas-conductive electrolyte having mutually spaced surfaces and on which is deposited a multiplicity of mutually spaced electrodes is described. Strips and of bare substances are interposed between electrodes, so that currents of ionic gas may be established between the electrodes via the bare strips, whereby electrical resistance for the cells is lowered and the gas conductivity is enhanced.

Richter, R.↗

Orthostatic fluid-electrolyte and endocrine responses in fainters and nonfainters

The responses to orthostasis of fluid-electrolyte and endocrine indicators in persons subject and not subject to fainting during tilting are investigated, along with the effects of heat acclimatization and physical training on those responses. Plasma volume and electrolytes and plasma vasopressin and renin activity were determined in tilt-table tests conducted before and after an eight-day period of daily heat acclimation during exercise at 50% maximal oxygen uptake at 40 C, or a control period of exercise at 24 C. Half of the 10 subjects in the study, regardless of exercise regime, showed improved orthostatic reactions in the second tilting test, related to increases in post-tilt plasma volume and potassium concentration, particularly in the nonfainters. In the first test, plasma renin activity is observed to increase fivefold and plasma vasopressin 50 times after the transition from the supine to the orthostatic positions; the respective increases were reduced by 50 and 75% in the second test. The fainters also exhibit a greater increase in vasopressin and a lower increase in renin activity upon tilting than the nonfainters. Results indicate the orthostatic-induced vasopressin increase to be related to volume control independent of renin activity.

Shvartz, E.↗

Ion Engine With Solid-Electrolyte Ion Generator

Working fluid utilized efficiently. Working fluid positive ions conducted through solid electrolyte to outside, then accelerated in external electric field. While in solid-electrolyte material, ions do not recombine with electrons: transported to surface with high ionization efficiency. Provides new way to generate beam of ions for implantation in semiconductors or other applications.

Richter, R.↗

Application of Organic Solid Electrolytes

If ions are considered to be solid material which transport electric charges, polymer materials can then be considered as organic solid electrolytes. The role of these electrolytes is discussed for (1) ion concentration sensors; (2) batteries using lithium as the cathode and a charge complex of organic material and iodine in the anode; and (3) elements applying electrical double layer capability.

Sekido, S.↗

Electrolyte management in porous battery components. Static measurements

The interaction between the porous hydrogen and nickel electrodes and microporous separator with respect to electrolyte management in nickel/hydrogen cells has been investigated. The distribution of electrolyte among the components has been measured and correlated with the pore size distributions, total void volume, and resistance of a variety of electrodes and separators. Calculations are used to show the effects of systematically varying these properties.

Abbey, K. M.↗

Current concepts of space flight induced changes in hormonal control of fluid and electrolyte metabolism

A systematic analysis of body fluid and renal dynamics during simulated space flight (head-down bedrest) was undertaken to increase understanding of the physiologic effects of acute cephalad fluid shifts. The earliest effects were increases in central venous pressure and decreases in plasma aldosterone, epinephrine and norepinephrine and glomerular filtration rate, 2 h after the beginning of bedrest. Decreases in plasma angiotensin I at 6 h may have resulted from the increased effective pressure and decreased sympathetic activity seen earlier in bedrest. The early decrease in aldosterone and ADH is thought to contribute to an increase, by 6 h, in urinary excretion of salt and water. Fluid and electrolyte losses occur during space flight, and analysis of body fluids from Space Shuttle crewmembers has indicated that conservation of these substances is begun almost immediately upon cessation of weightlessness. Operational medicine measures to counteract dehydration and electrolyte loss resulted in a less extreme physiologic response to the flight.

Leach, C. S.↗

Effects of exercise-heat acclimation on fluid, electrolyte, and endocrine responses during tilt and +Gz acceleration in women and men

Two aspects of prolonged endurance training were investigated: (1) the effects of exercise-heat acclimation (on a cycle ergometer at 40 C, 42 rh) on orthostatic tolerance (70 deg head-up tilt) and on a +Gz (head-to-foot) acceleration tolerance of male and female subjects; and (2) comparison of their fluid-electrolyte shifts and hormonal (plasma epinephdrine, norepinephrine, renin, and vasopressin) responses during tilting and centrifugation. The adaptive responses during the 12 d, 2-h acclimation did not alter acceleration tolerance of either men or women, or the women's tilt tolerance, but did increase men's tilt tolerance from 30.4 min before to 58.3 min after acclimation. The patterns of fluid, electrolyte, and protein shifts at tolerance in acceleration and tilting tests were virtually the same in men and women. On the other hand, the hormonal plasma epinephrine, norepinephrine, renin, and vasopressin resonses displayed different shift patterns during acceleration and tilting. It is concluded that the responses to tilting cannot be used to predict responses to acceleration. Future experiments for relating the orthostatic and the acceleration tolerances, and the practical questions of the training regimens for future astronauts are discussed.

Greenleaf, J. E.↗

Fluid and electrolyte control in simulated and actual spaceflight

Effects of microgravity on body fluid distribution and electrolyte and hormonal levels of astronauts have been studied since the early manned space missions. Bedrested subjects have been used as controls to separate effects of microgravity from those of hypokinesia. These investigations have led to documentation of the physiological effects of spaceflight and to a unified theory of response to microgravity. During flight, crewmembers have decreased thirst and a net loss of body water, sodium, and potassium. These changes seem to be initiated by passive transfer of extracellular fluid resulting in increased central venous pressure (CVP), to which the homeostatic mechanisms respond. A new equilibrium state is maintained during flight; it does not change in response to negative calcium and nitrogen balances during flight. On reexposure to gravity, profound water and salt retention occurs to replete extracellular fluid. Attempts to avoid cardiac deconditioning by repleting water and salt before leaving microgravity have somewhat ameliorated postural hypotension but have had little effect on CVP, cardiac chamber size or electrolyte dynamics.

Leach, C. S.↗

Advances in solid polymer electrolyte fuel cell technology with low-platinum-loading electrodes

The Gemini Space program demonstrated the first major application of fuel cell systems. Solid polymer electrolyte fuel cells were used as auxiliary power sources in the spacecraft. There has been considerable progress in this technology since then, particularly with the substitution of Nafion for the polystyrene sulfonate membrane as the electrolyte. Until recently the performance was good only with high platinum loading (4 mg/sq cm) electrodes. Methods are presented to advance the technology by (1) use of low platinum loading (0.35 mg/sq cm) electrodes; (2) optimization of anode/membrane/cathode interfaces by hot pressing; (3) pressurization of reactant gases, which is most important when air is used as cathodic reactant; and (4) adequate humidification of reactant gases to overcome the water management problem. The high performance of the fuel cell with the low loading of platinum appears to be due to the extension of the three dimensional reaction zone by introduction of a proton conductor, Nafion. This was confirmed by cyclic voltammetry.

Srinivasan, Supramaniam↗

Recent advances in solid polymer electrolyte fuel cell technology with low platinum loading electrodes

High power density fuel cell systems for defense and civilian applications are being developed. Taking into consideration the main causes for efficiency losses (activation, mass transport and ohmic overpotentials) the only fuel cell systems capable of achieving high power densities are the ones with alkaline and solid polymer electrolyte. High power densities (0.8 W/sq cm at 0.8 V and 1 A/sq cm with H2 and O2 as reactants), were already used in NASA's Apollo and Space Shuttle flights as auxiliary power sources. Even higher power densities (4 W/sq cm - i.e., 8 A sq cm at 0.5 V) were reported by the USAF/International Fuel Cells in advanced versions of the alkaline system. High power densities (approximately 1 watt/sq cm) in solid polymer electrolyte fuel cells with ten times lower platinum loading in the electrodes (i.e., 0.4 mg/sq cm) were attained. It is now possible to reach a cell potential of 0.620 V at a current density of 2 A/sq cm and at a temperature of 95 C and pressure of 4/5 atm with H2/O2 as reactants. The slope of the linear region of the potential-current density plot for this case is 0.15 ohm-sq cm. With H2/air as reactants and under the same operating conditions, mass transport limitations are encountered at current densities above 1.4 A/sq cm. Thus, the cell potential at 1 A/sq cm with H2/air as reactants is less than that with H2/O2 as reactants by 40 mV, which is the expected value based on electrode kinetics of the oxygen reduction reaction, and at 2 A/sq cm with H2/air as reactant is less than the corresponding value with H2/O2 as reactants by 250 mV, which is due to the considerably greater mass transport limitations in the former case.

Srinivasan, Supramaniam↗

Carbon dioxide electrolysis with solid oxide electrolyte cells for oxygen recovery in life support systems

The direct electrochemical reduction of carbon dioxide (CO2) is achieved without catalysts and at sufficiently high temperatures to avoid carbon formation. The tubular electrolysis cell consists of thin layers of anode, electrolyte, cathode and cell interconnection. The electrolyte is made from yttria-stabilized zirconia which is an oxygen ion conductor at elevated temperatures. Anode and cell interconnection materials are complex oxides and are electronic conductors. The cathode material is a composite metal-ceramic structure. Cell performance characteristics have been determined using varying feed gas compositions and degrees of electrochemical decomposition. Cell test data are used to project the performance of a three-person CO2-electrolysis breadboard system.

Isenberg, Arnold O.↗