Design and fabrication of a four-rod radio frequency quadrupole with a variable aperture

Radiofrequency quadrupole (RFQ) linear accelerators with variable aperture cell parameters offer an effective means of accelerating high-intensity ion beams exceeding 100 mA and have been implemented in various RFQ designs. However, in a four-rod RFQ, the use of dielectric perturbation methods to measure the voltage distribution behind the rod electrodes is not applicable when implementing variable aperture geometries, because changes in the rod shape influence the electric field at the location of the perturbation element. Therefore, it was necessary to design the rod profile for each cell such that the electric field distribution behind the rods remains unaffected by changes in the aperture. In this study, we present a method to adjust the voltage distribution by modifying the geometry of the rod electrodes according to each cell's aperture parameters. This design approach enables the integration of variable aperture cells into a four-rod RFQ linac, significantly enhancing the achievable beam current. To ensure uniform capacitance and maintain a constant rod-electrode voltage despite variations in the average aperture radius, we developed a systematic method for shaping the rod electrodes. This method was refined using two-dimensional (2D) and three-dimensional (3D) electromagnetic field simulations to optimize the electrode cross-sectional profiles. The fabricated rod electrodes were then installed in a four-rod RFQ, and the electric field distribution was measured using the perturbation method and tuned by adjusting the base plates. As a result, the measured variation of ±1.1 % confirms that this design methodology can produce a sufficiently uniform voltage distribution for high-current beam acceleration. These results demonstrate the practical feasibility of a variable-aperture four-rod RFQ linac.

43 PARTICLE ACCELERATORS↗

Probe the Localized Electrochemical Environment Effects and Electrode Reaction Dynamics for Metal Batteries using In Situ 3D Microscopy

Uncontrollable dendrite growth is closely related to non-uniform reaction environments. However, there is a lack of understanding and analysis methods to probe the localized electrochemical environment (LEE). Here the effects of the LEE are investigated, including localized ion concentrations, current density, and electric potential, on metal plating/stripping dynamics and dendrite minimization. A novel in situ 3D microscopy technique is developed to image the morphology dynamics and deposition rate of Zn plating/stripping processes on 3D Zn–Mn anodes. Using the in situ 3D microscope, the electrode morphology changes during the reactions are directly imaged and Zn deposition rate maps at different time points are obtained. It is found that reaction kinetics are highly correlated to LEE and electrode morphology. To further quantify the LEE effects, the digital twin technique is employed that allows the accurate calculation of the electrochemical environments, such as localized ion concentrations, current density, and electric potential, which cannot be directly measured from experiments. We found that the curvature of the 3D electrode surface determines the LEE and significantly influences reaction kinetics. This provides a new strategy to minimize the dendrite formation by designing and optimizing the 3D geometry of the electrode to control the LEE.

36 MATERIALS SCIENCE↗

Verification of electrical spin injection into InGaAs two-dimensional electron gas from CoFe electrode by four-terminal non-local geometry

We performed electrical spin injection into In{sub 0.75}Ga{sub 0.25}As two-dimensional electron gases from Co{sub 0.8}Fe{sub 0.2} electrodes by four-terminal non-local spin-valve (NLSV) measurement. We observed clear SV signals in NL resistance at 1.5 K. From the electrode spacing dependence of the signals, we estimated spin diffusion length and spin polarization to be ∼5.1 μm and ∼5.7 %, respectively. These are larger than those reported in similar systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enabling fast charging of lithium-ion batteries through secondary- /dual- pore network: Part I - Analytical diffusion model

Battery performance is strongly correlated with electrode microstructural properties. Enabling fast charging of lithium-ion batteries requires improved through-plane ionic diffusion that can be achieved through, among other strategies, structured electrodes with a secondary- or dual-pore network (SPN). In this work, an analytical model investigates the impact of such an SPN on ionic diffusion with a composite electrode, considering various pore-channel geometries and comparing to standard electrodes with identical gravimetric- and volumetric-specific theoretical capacities. Relevant SPN design parameters and tortuosity coefficients are identified according to three optimization objectives that aim to balance the improved overall through-plane diffusion, thanks to the coarse aligned channels, and degraded in-plane diffusion because of the porous matrix densification required to maintain gravimetric- and volumetric-specific theoretical capacities. The model indicates that a relatively low amount of SPN is required and that electrodes with high through-plane tortuosity and low in-plane tortuosity benefit most from such architecture.

25 ENERGY STORAGE↗

Electrostatic dispersion lenses and ion beam dispersion methods

An EDL includes a case surface and at least one electrode surface. The EDL is configured to receive through the EDL a plurality of ion beams, to generate an electrostatic field between the one electrode surface and either the case surface or another electrode surface, and to increase the separation between the beams using the field. Other than an optional mid-plane intended to contain trajectories of the beams, the electrode surface or surfaces do not exhibit a plane of symmetry through which any beam received through the EDL must pass. In addition or in the alternative, the one electrode surface and either the case surface or the other electrode surface have geometries configured to shape the field to exhibit a less abrupt entrance and/or exit field transition in comparison to another electrostatic field shaped by two nested, one-quarter section, right cylindrical electrode surfaces with a constant gap width.

Dahl, David A↗

An Exploration into Elemental Additions to Tungsten Electrodes

The scope of this study is to evaluate the arc start capabilities of various tungsten electrode alloys—2% Thoriated, 2% Ceriated, 2% Lanthanated, and a proprietary Tri-Mix WS2 on Stainless Steel 304 and Molybdenum. Each electrode maintained consistent geometry: 0.040" diameter, 2.000" length, and a 0.0010" flat tip with a 40° tip angle. The testing procedure aimed to determine the minimum starting amperage required to achieve 10 consecutive successful arc starts per electrode type.

36 MATERIALS SCIENCE↗

Deterministic switching of a magnetoelastic single-domain nano-ellipse using bending

In this paper, a fully coupled analytical model between elastodynamics with micromagnetics is used to study the switching energies using voltage induced mechanical bending of a magnetoelastic bit. The bit consists of a single domain magnetoelastic nano-ellipse deposited on a thin film piezoelectric thin film (500 nm) attached to a thick substrate (0.5 mm) with patterned electrodes underneath the nano-dot. A voltage applied to the electrodes produces out of plane deformation with bending moments induced in the magnetoelastic bit modifying the magnetic anisotropy. To minimize the energy, two design stages are used. In the first stage, the geometry and bias field (H{sub b}) of the bit are optimized to minimize the strain energy required to rotate between two stable states. In the second stage, the bit's geometry is fixed, and the electrode position and control mechanism is optimized. The electrical energy input is about 200 (aJ) which is approximately two orders of magnitude lower than spin transfer torque approaches.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Considerations for Contractile Electroactive Materials and Actuators

Ras Labs produces contractile electroactive polymer (EAP) based materials and actuators that bend, swell, ripple, and contract (new development) with low electric input. In addition, Ras Labs produces EAP materials that quickly contract and expand, repeatedly, by reversing the polarity of the electric input, which can be cycled. This phenomenon was explored using molecular modeling, followed by experimentation. Applied voltage step functions were also investigated. High voltage steps followed by low voltage steps produced a larger contraction followed by a smaller contraction. Actuator control by simply adjusting the electric input is extremely useful for biomimetic applications. Muscles are able to partially contract. If muscles could only completely contract, nobody could hold an egg, for example, without breaking it. A combination of high and low voltage step functions could produce gross motor function and fine manipulation within the same actuator unit. Plasma treated electrodes with various geometries were investigated as a means of providing for more durable actuation.

60 APPLIED LIFE SCIENCES↗

A computational modeling framework for pre-clinical evaluation of cardiac mapping systems

There are a variety of difficulties in evaluating clinical cardiac mapping systems, most notably the inability to record the transmembrane potential throughout the entire heart during patient procedures which prevents the comparison to a relevant “gold standard”. Cardiac mapping systems are comprised of hardware and software elements including sophisticated mathematical algorithms, both of which continue to undergo rapid innovation. The purpose of this study is to develop a computational modeling framework to evaluate the performance of cardiac mapping systems. The framework enables rigorous evaluation of a mapping system’s ability to localize and characterize (i.e., focal or reentrant) arrhythmogenic sources in the heart. The main component of our tool is a library of computer simulations of various dynamic patterns throughout the entire heart in which the type and location of the arrhythmogenic sources are known. Our framework allows for performance evaluation for various electrode configurations, heart geometries, arrhythmias, and electrogram noise levels and involves blind comparison of mapping systems against a “silver standard” comprised of computer simulations in which the precise transmembrane potential patterns throughout the heart are known. A feasibility study was performed using simulations of patterns in the human left atria and three hypothetical virtual catheter electrode arrays. Activation times (AcT) and patterns (AcP) were computed for three virtual electrode arrays: two basket arrays with good and poor contact and one high-resolution grid with uniform spacing. The average root mean squared difference of AcTs of electrograms and those of the nearest endocardial action potential was less than 1 ms and therefore appears to be a poor performance metric. In an effort to standardize performance evaluation of mapping systems a novel performance metric is introduced based on the number of AcPs identified correctly and those considered spurious as well as misclassifications of arrhythmia type; spatial and temporal localization accuracy of correctly identified patterns was also quantified. This approach provides a rigorous quantitative analysis of cardiac mapping system performance. Proof of concept of this computational evaluation framework suggests that it could help safeguard that mapping systems perform as expected as well as provide estimates of system accuracy.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemical Roughening of Thin-Film Platinum Macro and Microelectrodes

This protocol demonstrates a method for electrochemical roughening of thin-film platinum electrodes without preferential dissolution at grain boundaries of the metal. Using this method, a crack free, thin-film macroelectrode surface with up to 40 times increase in active surface area was obtained. The roughening is easy to do in a standard electrochemical characterization laboratory and incudes the application of voltage pulses followed by extended application of a reductive voltage in a perchloric acid solution. The protocol includes the chemical and electrochemical preparation of both a macroscale (1.2 mm diameter) and microscale (20 µm diameter) platinum disc electrode surface, roughening the electrode surface and characterizing the effects of surface roughening on electrode active surface area. This electrochemical characterization includes cyclic voltammetry and impedance spectroscopy and is demonstrated for both the macroelectrodes and the microelectrodes. Finally, roughening increases electrode active surface area, decreases electrode impedance, increases platinum charge injection limits to those of titanium nitride electrodes of same geometry and improves substrates for adhesion of electrochemically deposited films.

42 ENGINEERING↗

Plasma meniscus and extraction electrode studies of the ISIS H{sup -} ion source

In order to reduce the emittance and increase the transported beam current from the ISIS Penning-type H{sup -} ion source, improvements to the extraction system are required. This ion source is currently being commissioned on the front end test stand at the Rutherford Appleton Laboratory, which demands higher extraction energies, higher beam currents, and smaller emittances. To facilitate this, the present geometry requires optimization. This paper details the experimental and simulation studies performed of the plasma meniscus and the possible electrode geometry modifications needed to extract the highest quality beam.

43 PARTICLE ACCELERATORS↗

Closed electron drift in a self-magnetically insulated ion diode

The paper investigates a spiral geometry self-magnetically insulated ion diode with an explosive-emission cathode made from graphite. The experiments have been carried out using the TEMP-4M accelerator, with the accelerator configured to operate in double-pulse mode: the first negative pulse (300–500 ns, 100–150 kV) and the second positive pulse (150 ns, 250–300 kV). The ion beam energy density was 0.4–0.8 J/cm{sup 2} and the beam was composed of carbon ions (80%–85%) and protons. In order to increase the efficiency of ion current generation, we have developed a new diode with a spiral-shaped grounded electrode. Using this geometry, it seems possible to realize closed electron drift in a diode with self-magnetic insulation. In the spiral diode, the efficiency of accelerated ions is increased from 5%–9% (conventional self-insulated diodes) up to 30%–40%. The realization of closed electron drift in the diode increases the efficiency of C{sup +} ion generation up to 40–50 times the Childe-Langmuir limit, which is more than 4 times higher than with other known constructions of self-magnetically insulated diodes.

43 PARTICLE ACCELERATORS↗

The flush-mounted rail Langmuir probe array designed for the Alcator C-Mod vertical target plate divertor

An array of flush-mounted and toroidally elongated Langmuir probes (henceforth called rail probes) have been specifically designed for the Alcator C-Mod’s vertical target plate divertor and operated over multiple campaigns. The “flush” geometry enables the tungsten electrodes to survive high heat flux conditions in which traditional “proud” tungsten electrodes suffer damage from melting. The toroidally elongated rail-like geometry reduces the influence of sheath expansion, which is an important effect to consider in the design and interpretation of flush-mounted Langmuir probes. The new rail probes successfully operated during C-Mod’s FY2015 and FY2016 experimental campaigns with no evidence of damage, despite being regularly subjected to heat flux densities parallel to the magnetic field exceeding ~1 GW m -2 for short periods of time. A comparison between rail and proud probe data indicates that sheath expansion effects were successfully mitigated by the rail design, extending the use of these Langmuir probes to incident magnetic field line angles as low as 0.5°.

47 OTHER INSTRUMENTATION↗

The flush-mounted rail Langmuir probe array designed for the Alcator C-Mod vertical target plate divertor

An array of flush-mounted and toroidally elongated Langmuir probes (henceforth called rail probes) have been specifically designed for the Alcator C-Mod’s vertical target plate divertor and operated over multiple campaigns. The “flush” geometry enables the tungsten electrodes to survive high heat flux conditions in which traditional “proud” tungsten electrodes suffer damage from melting. The toroidally elongated rail-like geometry reduces the influence of sheath expansion, which is an important effect to consider in the design and interpretation of flush-mounted Langmuir probes. The new rail probes successfully operated during C-Mod’s FY2015 and FY2016 experimental campaigns with no evidence of damage, despite being regularly subjected to heat flux densities parallel to the magnetic field exceeding ∼1 GW per square meter for short periods of time. A comparison between rail and proud probe data indicates that sheath expansion effects were successfully mitigated by the rail design, extending the use of these Langmuir probes to incident magnetic field line angles as low as 0.5 degree.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atomic and molecular effects on spherically convergent ion flow. I. Single atomic species

A formalism for analyzing the effect of ion-neutral gas interactions on the flow of ions between nearly transparent electrodes in spherical geometry has been developed for atomic ions in a weakly ionized plasma, so that the important atomic effects are charge exchange and ion impact ionization. The formalism is applied to spherical, gridded, inertial-electrostatic confinement (IEC) devices. The formalism yields detailed information about the energy spectra of the ions and fast neutral atoms, and the resulting fusion rate for {sup 3}He ions in a background {sup 3}He gas. The results are illustrated with an example calculation for the Wisconsin IEC device operating on {sup 3}He.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transport properties of individual C{sub 60}-molecules

Electrical and thermal transport properties of C{sub 60} molecules are investigated with density-functional-theory based calculations. These calculations suggest that the optimum contact geometry for an electrode terminated with a single-Au atom is through binding to one or two C-atoms of C{sub 60} with a tendency to promote the sp{sup 2}-hybridization into an sp{sup 3}-type one. Transport in these junctions is primarily through an unoccupied molecular orbital that is partly hybridized with the Au, which results in splitting the degeneracy of the lowest unoccupied molecular orbital triplet. The transmission through these junctions, however, cannot be modeled by a single Lorentzian resonance, as our results show evidence of quantum interference between an occupied and an unoccupied orbital. The interference results in a suppression of conductance around the Fermi energy. Our numerical findings are readily analyzed analytically within a simple two-level model.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effect of insulator length and fill pressure on filamentation and neutron production in a 4.6 kJ dense plasma focus

Optimization of neutron yields from dense plasma focus devices is a complex multi-faceted challenge that necessitates the prudent selection of mechanical constraints such as the electrode and insulator geometries. Here, the neutron yield is found to significantly depend on the insulator length. As the length of the insulator increases, the exposed anode length traveled by the sheath during the run-down phase decreases. This suggests an increase in the optimal fill pressure with increasing insulator length to maintain the pinch time near peak current. However, in the present study, the opposite trend is observed—the optimal fill pressure for neutron production decreases with increasing insulator length. Optical probing of the sheath from run-down to the pinch reveals significant plasma filamentation with increasing pressure and a dependence of insulator length on filamentation onset. A direct consequence of increased filamentation is a reduction in mass sweeping efficiency, directly quantified as a function of fill pressure for the first time.

Hahn, E. N. (ORCID:0000000223050532)↗