Well integrity monitoring with electric fields by using hierarchical geo-electric models.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
A quantum dot microscope apparatus is provided. A further aspect employs a tilted or tapered end or tip on a microscopic probe. Another aspect of the present apparatus employs a probe including a quantum dot with only one tunneling lead connected to a power source. A manufacturing aspect includes creating a tapered or asymmetrically shaped specimen-facing end of a probe where a quantum dot is located on the end. A further manufacturing aspect includes using focused ion-beam milling to create a tip or end of a quantum dot microscope probe.
In this paper, we propose a superstructure-based approach to finding the optimal pathways for recovering rare earth elements in their commercialized rare earth oxide form from end-of-life EV and HEV motors. The proposed superstructure was modeled as a MILP optimization problem, selecting the net present value as the objective function. Whenever possible, costing data taken from the literature was used to inform this mode. However, due to the novelty of this research area data were often not available thus requiring the generation of flowsheets that were implemented in Aspen Plus.
Explore the source record for details and available documents.
The electrical substation-grid testbed was created to integrate the GOOSE and/or DNP (Distributed Network Protocol) messages with time synchronized sources and Distributed Ledger Technology (DLT). The objective was to study the impact of faults and cyber-events at an electrical substation with inside (protective relays) and outside (power meters) substation devices. The electrical substation-grid testbed was based on the design of a 34.5/ 12.47 kV electrical substation (sectionalized bus configuration) with two power transformers, connected to radial power lines and load feeders. The electrical substation-grid testbed was installed at 252 lab space (Advanced Power System Protection), Grid Research Integration and Deployment Center (GRID-C), Oak Ridge National Laboratory. This testbed was created for Task 5, DarkNet project. The electrical substation-grid testbed was created to simulate fault and/or cyber events that could potentially result in damage to the electrical infrastructure. In addition, tests were run that are usually not allowed to be performed in an operational electrical power grid, because these test scenarios could trip breakers and/or generate fault situations that could potentially damage equipment. The number of tests performed in the electrical substation-grid testbed were executed in a better way than in a real electrical substation and/or power grid, because multiple tests could be run in a short period of time, and complex permits, and safety/ schedule restrictions like in a real electrical substation environment were not needed. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that are used by electrical utilities, to have same conditions that we could observe in a real power grid or electrical substation. The electrical substation-grid testbed was based on using a real time simulator and expansion box with amplifiers that were wired to electrical substation-grid devices. This hardware-in-the-loop (HIL) was provided by protective relays, power meters, ethernet switches, remote terminal units, synchronized timing network clock, DLT devices, workstations, and servers. This report includes the design, installation, and assessment of the electrical substation-grid testbed that was similar to an operational electrical substation, integrating the power system protection, communication, and control systems. The results for the electrical substation-grid testbed were based on:• verifying the analog signals for protective relays and power meters, • observing the synchronized time source frame at devices, • authenticating the GOOSE (IEC 61850) and DNP messages from power meters and protective relays, and • verifying the trip conditions of protective relays at fault tests with the power system fault event detection, using DLT devices. For future work, the electrical substation-grid testbed with protective relays and power meters, using DLT and synchronized time source from DarkNet, will be used to study the impact of cyber-events at inside and outside substation devices. Advanced algorithms for detecting cyber-events produced by non-desired protective relay settings will be studied, to improve the detection and reliability of protection, control, and communication systems at power grids.
Electric vehicles (EVs) use electricity as their primary fuel or to improve the efficiency of conventional vehicle designs. EVs include all-electric vehicles, also referred to as battery electric vehicles (BEVs), and plug-in hybrid electric vehicles (PHEVs). In colloquial references, these vehicles are called electric cars, or simply EVs, even though some of these vehicles still use liquid fuels in conjunction with electricity. EVs are known for providing instant torque and a quiet driver experience. Other types of electric-drive vehicles not covered here include hybrid electric vehicles, which are powered by a conventional engine and an electric motor that uses energy stored in a battery, and fuel cell electric vehicles, which use a propulsion system similar to electric vehicles, where energy stored as hydrogen is converted to electricity by the fuel cell.
Electric vehicles (EVs) use electricity as their primary fuel or to improve the efficiency of conventional vehicle designs. EVs include all-electric vehicles, also referred to as battery electric vehicles (BEVs), and plug-in hybrid electric vehicles (PHEVs). In colloquial references, these vehicles are called electric cars, or simply EVs, even though some of these vehicles still use liquid fuels in conjunction with electricity. EVs are known for providing instant torque and a quiet driver experience. Other types of electric-drive vehicles not covered here include hybrid electric vehicles, which are powered by a conventional engine and an electric motor that uses energy stored in a battery that is charged by regenerative braking, not by plugging in, and fuel cell electric vehicles, which use a propulsion system similar to electric vehicles, where energy stored as hydrogen is converted to electricity by the fuel cell. This is the French translation of NREL/FS-5400-87125.
Electric vehicles (EVs) use electricity as their primary fuel or to improve the efficiency of conventional vehicle designs. EVs include all-electric vehicles, also referred to as battery electric vehicles (BEVs), and plug-in hybrid electric vehicles (PHEVs). In colloquial references, these vehicles are called electric cars, or simply EVs, even though some of these vehicles still use liquid fuels in conjunction with electricity. EVs are known for providing instant torque and a quiet driver experience. Other types of electric-drive vehicles not covered here include hybrid electric vehicles, which are powered by a conventional engine and an electric motor that uses energy stored in a battery that is charged by regenerative braking, not by plugging in, and fuel cell electric vehicles, which use a propulsion system similar to electric vehicles, where energy stored as hydrogen is converted to electricity by the fuel cell.
Universal access to electricity is an essential part of sub-Saharan Africa's path to development. With the United Nations setting Goal 7 of its sustainable development goals to be universal access to clean, reliable and affordable electricity, substantial research efforts have been made to optimize electricity supply based on projected demand in sub-Saharan African (SSA) countries. Our study reviews the literature on electricity demand, with a specific focus on latent demand (i.e., electricity demand that would exist if the necessary techno-economic conditions were met) in SSA. We found that out of 57 electricity demand papers reviewed, only 3 (5%) incorporated latent demand in their electricity demand projections. Furthermore, majority of the literature on electricity consumption and demand estimation in SSA use econometric models to identify determinants of electricity consumption and project future demand. We find that population density, urbanization, household income, electricity price, market value of crops and availability of natural resources to be significant determinants of electricity consumption in SSA. We conclude the review by proposing a methodology, and providing an initial proof of concept, for more accurately projecting latent demand in sub-Saharan Africa. Incorporating latent demand in electrification models would help inform energy sector stakeholders (e.g., investors and policymakers) about which sectors and geographic locations hold potential for wealth creation via electricity access.
Electrification of residential buildings is a key strategy for increasing the use of renewable energy sources. Central to this transition is understanding the capacity of existing electrical infrastructure—specifically electrical panels—to safely and effectively manage increased electricity demands from electrification technologies. However, comprehensive nationwide data on electrical panel capacities in U.S. single-family homes is currently lacking. To address this gap, we conducted a nationwide survey of single-family homes, collecting detailed data on electrical panel capacities, breaker slot availability, major electric and gas appliances, electrical panel models, and home characteristics such as construction year and floor area. Photographic documentation was used to verify electrical panel data and appliance information. Results show that approximately 60% of surveyed homes have electrical panels rated at ≥200 amperes (A), indicating that a significant portion of the existing housing stock can accommodate additional electric loads. However, 31% of homes possess panels rated at ≤100 A, potentially restricting their ability to adopt new electric appliances without significant upgrades. Panel capacities positively correlate with both home size and construction year, with newer and larger homes generally better suited for electrification. Homes with higher-capacity panels tend to have fewer gas appliances, reflecting a gradual shift toward electric technologies. Conversely, homes with lower-capacity panels frequently rely on multiple gas appliances, highlighting substantial electrification challenges. Additionally, approximately 3% of surveyed homes had potentially hazardous electrical panel models, emphasizing important safety considerations in the residential electrification process. Our findings underscore the need for targeted policies, financial incentives, and infrastructure investments designed specifically to address infrastructural and safety barriers, particularly in older and smaller homes, to support equitable and efficient electrification across the U.S. residential sector.
The last decade has seen a steady evolution of the electricity generation sector. Fuels used for electricity generation have shifted from coal to cleaner energy sources such as natural gas and renewables including solar, wind, and other renewable sources. The share of U.S. electricity generated from coal decreased from 45% in 2010 to 24% in 2019, and is expected to decrease further to 13% by 2050. The conversion efficiency of electricity generation has also increased gradually for fuels such as natural gas due as less-efficient old generators are retired and more-efficient generators replace them. These changes in the electricity generation industry are likely to cause changes in the emissions from power generation units. Emission factors of greenhouse gases (GHG) including CO 2 , CH 4 , and N 2 O, and criteria air pollutants (CAPs) including CO, NO x , PM 10 , PM 2.5 , and SO x , from power plants are important parameters for estimating life-cycle emissions associated with vehicle electrification, energy systems, and the production of materials and chemicals. The electricity generation technologies and associated emission factors in the Greenhouse Gases, Regulated Emissions, and Energy Use in Technologies (GREET) model need to be updated to reflect recent developments in the electricity generation sector. The most recent update of the electricity generation emission factors in GREET adopted a mixed method. The emission factors of CH 4 , N 2 O, NO x , and SOx were estimated using a “topdown” approach by dividing the total emissions by the total net electricity generation, because emission data of these pollutants are readily available in the Emissions & Generation Resource Integrated Database (eGRID). For other CAPs such as CO, VOC, PM 10 , and PM 2.5 , emission data were not reported in eGRID. A “bottom-up” method was used to estimate the emission factors for these pollutants by considering generic uncontrolled emission factors and the pollutant removal efficiencies of emission control technologies adopted in the electricity generation sector. However, the uncontrolled emission factors and the emission removal efficiencies of various emission control technologies considered in the 2012 study came from the legacy AP-42 emission factors, and may not reflect the actual emission performances of the electricity generation sector of today. To leverage new data that recently became available, especially emission data measured from continuous emission monitoring systems (CEMS), we developed a new “top-down” approach to estimate efficiencies and GHG and CAP emission factors for electricity generation from combustion of individual fuel types by individual combustion technologies on the basis of power-generation data from U.S. Energy Information Administration’s (EIA’s) form EIA-923, and plant emission data from Environmental Protection Agency’s (EPA’s) Clean Air Markets Division (CAMD) dataset and National Emissions Inventory (NEI) dataset. Detailed discussion of the method and data used in this study can be found in Section 2.1. With this topdown approach, we aim to improve the estimates of energy efficiencies and emission factors for power plants using a more consistent methodology, and to update the emission factors, generation efficiencies, and generation technologies mixes in GREET to reflect recent technology advancements in the electricity generation sector.
The electricity sector represents the centerpiece of decarbonization pathways for the state. Decrease in the cost of renewable electricity generation, combined with ample solar energy, wind and other renewable resources, presents a realistic way to achieve electricity generation that is nearly free of CO 2 emissions by mid-century. Expansion of renewable electricity supply could allow replacement of many CO 2 -emitting technologies with ones that use electricity—in transportation, buildings, and possibly industry. Key elements of the path for California’s electricity sector are: restrain electricity demand through higher efficiency, rapidly expand renewable electricity generation, develop electricity storage to complement renewable electricity, manage flexible electricity loads for a low-carbon electricity system, electrify where appropriate to reduce CO 2 emissions, and maintain reliable and resilient electricity supply. This report provides an overview of a multitude of innovative technologies in each of the above areas that have the potential to help the state meet its decarbonization goals, while lowering costs and promoting greater reliability. The information presented provides a portrait of the landscape of technology innovation that can help policymakers, state agencies, and interested parties develop strategies to meet the state’s goals and to target efforts to support and nurture technology innovation.
Electricity production is one of the largest sources of environmental emissions - especially greenhouse gases (GHGs) - in the USA. Emission factors (EFs) vary from region to region, which requires the use of spatially relevant EF data for electricity production while performing life cycle assessments (LCAs). Uncertainty information, which is sought by LCA practitioners, is rarely supplied with available life cycle inventories (LCIs). To address these challenges, we present a method for collecting data from different sources for electricity generation and environmental emissions; discuss the challenges involved in agglomerating such data; provide relevant suggestions and solutions to merge the information; and calculate EFs for electricity generation processes from various fuel sources for different spatial regions and spatial resolutions. The EFs from the US 2016 Electricity Life Cycle Inventory (eLCI) are analyzed and explored in this study. We also explore the method of uncertainty information derivation for the EFs. We explore the EFs from different technologies across Emissions & Generation Resource Integrated Database (eGRID) regions in the USA. We find that for certain eGRID regions, the same electricity production technology may have worse emissions. This may be a result of the age of the plants in the region, the quality of fuel used, or other underlying factors. Region-wise life cycle impact assessment (LCIA) ISO 14040 impacts for total generation mix activities provide an overview of the total sustainability profile of electricity production in a particular region, rather than only global warming potential (GWP). We also find that, for different LCIA impacts, several eGRID regions are consistently worse than the US average LCIA impact for every unit of electricity generated. Here this work describes the development of an electricity production LCI at different spatial resolutions by combining and harmonizing information from several databases. The inventory consists of emissions, fuel inputs, and electricity and steam outputs from different electricity production technologies located across various regions of the USA. This LCI for electricity production in the USA will prove to be an enormous resource for all LCA researchers - considering the detailed sources of the information and the breadth of emissions covered by it.
Timely removal of ice and snow from roads is critical to safe, fast, and uninterrupted transportation networks in cold regions. Constructing electrically conductive asphalt pavements to melt the ice and snow on the roads through resistive eating is an emerging alternative technology to traditional snow/ice removal approaches such as utilizing snowplow machines and deicing chemicals. Carbon-based fibers and fillers including carbon fiber and graphite have been widely reported to make electrically conductive hot mix asphalt mixtures for pavement snow/ice-melting applications. This study aimed to develop and demonstrate a novel type of electrically conductive asphalt pavements for snow/ice-melting, which utilizes electrically conductive cold mix asphalt (CMA) mixtures incorporating coal-derived carbon-based coke aggregate as resistive heating elements. Both laboratory experiments and field tests were conducted to investigate the electrical, mechanical, and thermal properties of such electrically conductive asphalt mixtures and pavements. The laboratory experiment results indicated that the electrically conductive CMA mixtures incorporating coke aggregate had sufficiently high electrical conductivity and satisfactory mechanical performance and the pavement prototype slab utilizing a thin layer of such CMA mixtures could successfully raise the pavement surface temperatures to 8.3–11.7 °C rom a low temperature of –5 °C with an input power density of 473 W/m 2 . The field test results showed that the full-scale coal-derived electrically conductive asphalt pavements were able to increase the pavement surface temperatures when electricity was applied, but the magnitude of temperature increase was highly dependent on the power density. Furthermore, it is promising to use coke aggregate to construct coal-derived electrically conductive asphalt pavements for snow/ice melting.
Buildings are the primary users of electricity, and a considerable amount of electric energy consumed in residential and commercial buildings is for meeting thermal demands (e.g., space heating/cooling, water heating, etc.). Therefore, integrating thermal energy storage with a building’s energy system has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable power supply and the thermal demands of buildings. A novel ground-source heat pump system (GSHP) integrated with underground thermal energy storage (UTES) has been developed to enable flexible electric demand at buildings while meeting their thermal demands with an energy-efficient GSHP system. This paper assessed the potential impacts of the proposed system on the peak electrical demand and annual electricity consumption in a typical residential building at various climate zones in the United States. The results show that by replacing the conventional HVAC system (air conditioner and natural gas furnace) with the UTES integrated GSHP system, summer peak electric demand can be reduced by 27% to 50% depending on the weather. Although the winter peak electrical demand could be increased by up to 70% if the proposed system replaces natural gas furnace, the existing electricity supply system for single-family homes in most regions of the United States have adequate capacity for the replacement. While eliminating the natural gas consumption for space heating, the proposed system consumes more electricity on an annual basis in heating-dominated regions. However, it consumes less electricity in cooling dominated regions. The resulting variance in annual electricity consumption in various climate zones is within 15% compared with the baseline system.
Hydropower importantly provides flexible low-carbon electricity, however, climate change will affect the hydropower system through altering hydrologic regimes while also affecting electricity demands for heating and cooling that hydropower resources serve. This study assesses the effect of climate change on hydropower and electricity demand in the Upper Yangtze River Basin (UYRB) in China on the regional net electric load and greenhouse gas (GHG) emissions. This is accomplished by using climate projections from five global climate models (GCMs) to simultaneously force (1) a physically-based hydrological model and a statistically-based hydropower model to estimate the future generating capacity of 21 large hydropower plants in the UYRB and (2) an empirical electricity demand model accounting for socioeconomic and climatic factors. Under climate change, the projected hydropower generation in the UYRB tends to increase in the 21st century but is far less than the increase in electricity demand, increasing the gap between demand and supply. Future increases in overall electricity demand are driven by GDP growth, but climate change will alter the distribution of the seasonal electricity demand. Climate warming decreases electricity demand for heating in winter and increases electricity demand for cooling in summer, but ultimately increases demand. Meanwhile, there is an increasing mismatch between electricity demand and hydropower supply associated with inter- and intra-annual variations, owing to the temporal climate change and increase in compound climate extremes (droughts and heatwaves). Finally, meeting the gap between supply and demand due to climate change is estimated to contribute 79.0–184.6 and 50.6–316.2 MMT CO 2e /yr of additional GHG emissions by the mid and end of 21st century, respectively.
Electricity generation in the United States entails significant water usage and greenhouse gas emissions. However, accurately estimating these impacts is complex due to the intricate nature of the electric grid and the dynamic electricity mix. Existing methods to estimate the environmental consequences of electricity use often generalize across large regions, neglecting spatial and temporal variations in water usage and emissions. Consequently, electric grid dynamics, such as temporal fluctuations in renewable energy resources, are often overlooked in efforts to mitigate environmental impacts. The U.S. Department of Energy (DOE) has initiated the development of resilient energyshed management systems, requiring detailed information on the local electricity mix and its environmental impacts. This study supports DOE's goal by incorporating geographic and temporal variations in the electricity mix of the local electric grid to better understand the environmental impacts of electricity end users. We offer hourly estimates of the U.S. electricity mix, detailing fuel types, water withdrawal intensity, and water consumption intensity for each grid balancing authority through our publicly accessible tool, the Water Integrated Mapping of Power and Carbon Tracker (Water IMPACT). While our primary focus is on evaluating water intensity factors, our dataset and programming scripts for historical and real-time analysis also include evaluations of carbon dioxide (equivalence) intensity within the same modeling framework. This integrated approach offers a comprehensive understanding of the environmental footprint associated with electricity generation and use, enabling informed decision-making to effectively reduce Scope 2 water usage and emissions.
Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation and are associated with distributed energy resources (DERs). The integrity and confidentiality of data from IEDs is crucial, and distributed ledger technology (DLT) could improve the resilience of microgrids by helping to make these data more secure. The most popular applications using blockchain technology for electrical utilities is in the field is based on energy trading. However, the dynamism of the penetration of customer owned DERs and the deployment of sensors with IEDs have led to the identification of new applications using DLT that are focused on other areas, such as monitoring, operation and management of the grid and its assets. In addition, the majority of studies on electrical grid applications with blockchain were validated with software simulations. Although general monitoring of power systems for using DLT could be evaluated in operational electric grids, other DLT research applications such as defense against cyber-attacks and/or electrical fault detection are not likely to be performed in a real infrastructure because of possible risks to the network/equipment security. This report summarizes the application of power system applications using distributed ledger technology (DLT), providing a secure DLT framework for collecting data from IEDs like power meters and protective relays inside and outside of an electrical substation and/or between two different electrical utilities. In this study, the use case scenarios were created and assessed for different power system application by using DLT. The electrical fault detection for faulted phases (1), power quality monitoring of phase voltage magnitudes, frequency levels and load power factor (2), DERs use case monitoring (3), and cyber-event applications (4) were performed in a test bed with a Cyber-Grid Guard (CGG) system using DLT. It had a real-time simulator with power meters and protective relays in-the-loop. The first section of this report presents a literature review of power system applications using blockchain at research level. The second section shows the theory and equations used on this report. The third section shows the description of the test bed, equipment, architecture, and electrical grid diagrams. The fourth section shows the experimental models and use case scenarios that were performed for the electrical fault detection, power quality, DERs use case, and cyber event applications with the CGG system using DLT. The fifth section shows the results collected from the tests based on comparing the time stamped events of the analog signals from the IEDs, DLT computer and real time simulator. The sixth section performed the discussion of the results for the use case scenarios. Finally, section seven presents the conclusions for this report were presented.