Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Wireless Power Transfer for Space Applications

This paper introduces an implementation for magnetic resonance wireless power transfer for space applications. The analysis includes an equivalent impedance study, loop material characterization, source/load resonance coupling technique, and system response behavior due to loads variability. System characterization is accomplished by executing circuit design from analytical equations and simulations using Matlab and SPICE. The theory was validated by a combination of different experiments that includes loop material consideration, resonance coupling circuits considerations, electric loads considerations and a small scale proof-of-concept prototype. Experiment results shows successful wireless power transfer for all the cases studied. The prototype provided about 4.5 W of power to the load at a separation of -5 cm from the source using a power amplifier rated for 7 W.

Ramos, Gabriel Vazquez↗

Demonstration of a modeling toolkit for the design of building electrical distribution systems

The deployment of building equipment (e.g., lighting, security) and miscellaneous electrical loads that fundamentally require DC power for operation is increasing. Powering these DC loads has traditionally required an AC/DC converter, but the installation of photovoltaic (PV) and battery energy storage systems that primarily produce DC power eliminates the need for AC/DC converters at each end-device. However, analyzing system energy efficiency and cost for different electrical distribution architectures can be challenging as software tools that support this are not readily available. This paper presents preliminary results from a laboratory verification of the Building Electrical Efficiency Analysis Model (BEEAM) toolkit that was developed to address this gap. Three different eight-luminaire lighting systems comprised of market-available products were designed and modeled: one that used traditional AC distribution, a second that used a hybrid AC -to- centralized DC electrical distribution architecture, and a third that used a hybrid AC -to- distributed DC architecture. Notably, AC/DC conversions are required in all three systems. BEEAM models for LED drivers as well as Power-over-Ethernet (PoE) switches were created using laboratory characterization data. The lighting systems were simulated in Modelica, and the results were compared with each other and physics-based expectations. Simulation results show that PoE system energy efficiency is highly dependent on both device specification (e.g., LED driver and PoE switch efficiency) and system architecture (e.g., PoE switch loading) choices, as expected. For the products and system architectures selected for this study, the two DC systems were found to be less efficient than the AC system over the course of typical operation. In future work, simulation results will be compared with laboratory measurements to validate the usefulness of this software for design, and lighting systems with integrated PV and battery energy storage will be simulated to quantify the energy performance improvements that result from the elimination of some AC/DC converters.

Waghale, Anay S.↗

Potential of Utilizing Thermal Energy Storage Integrated Ground Source Heat Pump System to Reshape Electricity Demand in the United States

Each year, more than 20% of electricity generated in the United States is consumed for meeting the thermal demands (e.g., space cooling, space heating, and water heating) in residential and commercial buildings. Integrating thermal energy storage (TES) with building’s HVAC systems has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable generation and the demand of buildings. A novel ground source heat pump (GSHP) system integrated with underground thermal energy storage (UTES) has been proposed to level the electric demand of buildings while still satisfying their thermal demands. This study assessed the potential impacts of the proposed system with a bottom-up approach. The impacts on the electricity demand in various electricity markets were quantified. The results show that, within the capacity of the existing electric grids, the maximum penetration rate of the proposed system in different wholesale markets could range from 51% to 100%. Altogether, about 46 million single-family detached houses can be retrofitted into the proposed system without increasing the annual peak demand of the corresponding markets. By implementing the proposed system at its maximum penetration rate, the grid-level summer peak demand can be reduced by 9.1% to 18.2%. Meanwhile, at the grid level, the annual electricity consumption would change by –12% to 2%. The nationwide total electricity consumption would be reduced by 9%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heavy-Duty Truck Electrification and the Impacts of Depot Charging on Electricity Distribution Systems

Major technological advancements and recent policy support are improving the outlook for heavy-duty truck electrification in the United States. In particular, short-haul operations (=200 miles (=322 km)) are prevalent and early candidates for plug-in electric vehicles (EVs) given their short, predictable routes and return-to-base applications, which allows vehicles to recharge when off shift at their depots. Although previous studies investigated the impacts of added electrical loads on distribution systems, which included light-duty EVs, the implications for heavy-duty EV charging are underexplored. Here we summarize the causes, costs and lead times of distribution system upgrades anticipated for depot charging. We also developed synthetic depot charging load profiles for heavy-duty trucks from real-world operating schedules, and found that charging requirements are met at common light-duty EV charging rates (=100 kW per vehicle). Finally, we applied depot charging load profiles to 36 distribution real-world substations, which showed that most can accommodate high levels of heavy-duty EV charging without upgrades.

47 OTHER INSTRUMENTATION↗

Design of a Compact Dry Cooler With an Aluminum Heat Exchanger Core for a Supercritical CO2 Power Cycle Is Evaluated for a Concentrating Solar Power Application

Abstract As the supercritical CO2 power cycle develops and the component technologies mature, there is still a need to reduce the associated capital and operating costs to maintain a competitive levelized cost of electricity (LCOE) in order to enter the market. When considering concentrating solar power (CSP) coupled with an sCO2 power block and sensible thermal storage, the technology presents a clean source for utility-scale power generation to support baseload or peak-load electrical demand. However, the LCOE of the technology is still considered higher than the competing technologies and should be reduced to better compete in the market; 2030 targets for dispatchable solar plants are 5¢/kWh for baseload CSP and 10¢/kWh for peaker plants, as set by the United States Department of Energy. In response to this need, this study is targeting improvements in the power cycle precooler to reduce power block contribution to LCOE. This study considers a dry cooler, as CSP plants are sensitive to water consumption because many installations are slated for remote or arid locations where solar irradiance is very high, but water is scarce. Furthermore, the power block footprint for an sCO2 system is quite compact, especially as compared to a steam cycle. Therefore, there is interest in installing a more compact dry cooler that is proportional to the reduced footprint sCO2 power block, while conventional dry coolers are an order of magnitude larger. The competing goals of size, performance, and cost were considered in this study to develop a compact dry cooler that can easily be packaged with the power block, significantly reducing the installation and transport cost compared to the current state of the art, while maintaining or improving upon the heat transfer performance and impact on plant LCOE. This paper details the high-level findings of a large dry cooler sensitivity study for design point selection, design of the compact dry cooler, expected year-round performance for the dry cooler and the power cycle, and the predicted LCOE for a 30-year plant life. It was found that an aluminum heat exchanger core can be suitably designed to meet the pressure and temperature requirements for a precooler in an sCO2 recompression Brayton cycle. The dry cooler assembly was found to have improved heat transfer performance, allowing for increased cycle efficiencies and a reduced plant LCOE. When coupled with a centrifugal blower and compact transition duct, the dry cooler assembly was able to reduce the installation footprint by over 50%.

14 SOLAR ENERGY↗

Building Model Calibration: Validation of GridLAB-D Thermal Dynamics Modeling

This report investigates how well GridLAB-D’s house model characterizes the thermal dynamics of buildings given the overpredicted diurnal electric load swing observed in the Distribution System Operation with Transactive (DSO+T) study. This study seeks to validate GridLAB-D’s house model by calibrating it to data from the well-instrumented Pacific Northwest National Laboratory Lab Homes in Richland, WA. The datasets chosen included multiple pre-cooling and pre-heating testing periods where the indoor air temperature was allowed to float over a multi-hour length of time to mimic diurnal behavior. The multi-season calibrations were evaluated by comparing the heating/cooling electric power, indoor air temperature, and the rise/decay time during temperature float periods with Lab Homes data. The default GridLAB-D assumptions for latent load fraction, air heat capacity, mass heat capacity, window-to-wall-ratio, overall envelope conductance (assumed as NORMAL thermal integrity level), and solar heat gain coefficient were compared with the calibrated model to confirm when the default assumptions were adequate and the impact of calibration on the accuracy of modeling the thermal dynamics of homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fast Charging Infrastructure for Electrifying Road Trips to and from National Parks in the Western United States

National parks in the Western United States draw over 80 million visitors every year, and most visitors rely on personal cars for their road trips (or long-distance travels). Travel to national parks represents distinct travel demand, as they are typically located in remote areas necessitating long-distance trips. This study investigates the quantity and locations of on-route fast charging infrastructure needed by 2030 to enable seamless travel to/from national parks using electric vehicles in seven target states in the region, employing unprecedented high-resolution spatial and temporal analysis. We find that the required number of fast charging ports for on-route charging infrastructure ranges from 1,200 to 22,000, depending on different assumptions of key input parameters - vehicle electrification rate, charging behavior, average gap between charging stations, port utilization rate, and towing trailers. Our analysis also indicates that electrical load for on-route fast charging infrastructure would peak in the afternoon, in the range of 70-400 MW, varying with the key input parameters. This study illustrates how different input parameters result in different degrees of impact on various aspects of charging infrastructure. We also examine the characteristics of projected charging infrastructure in terms of land use type, relationship with traffic volume, size of stations, and other variables.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical power generation from moderate-temperature radiative thermal sources

Moderate-temperature thermal sources (100° to 400°C) which radiate waste heat are often the by-product of mechanical work, chemical or nuclear reactions, or information processing. We demonstrate conversion of thermal radiation into electrical power using a bipolar grating-coupled complementary metal-oxide-silicon (CMOS) tunnel diode. A two-step photon-assisted tunneling charge pumping mechanism results in separation of charge carriers in pn-junction wells leading to a large open-circuit voltage developed across a load. Electrical power generation from a broadband blackbody thermal source has been experimentally demonstrated with converted power densities of 27 to 61 microwatts per square centimeter for thermal sources between 250° and 400°C. Scalable, efficient conversion of radiated waste heat into electrical power can be used to reduce energy consumption or to power electronics and sensors.

30 DIRECT ENERGY CONVERSION↗

Competitiveness Assessment of Decarbonizing Electricity and Process Heat Supply to a Campus with a Small Nuclear Reactor

This paper analyzes the competitiveness of siting a small nuclear reactor to support decarbonization of sites requiring tens of MW of electricity and/or process heat to support centralized heating and cooling system. This paper focuses on campuses as representative of sites with collections of buildings and research facilities with decarbonization needs represented by buildings heating, and electricity consumption by electrical loads which may include cooling via chilled water (e.g., for air conditioning and to cool down computer clusters). A nuclear reactor can be considered to decarbonize a site’s high-temperature steam generation used mostly for building heating needs, climate control, and hot water, by supplying process heat capabilities, while electricity decarbonization would be achieved mostly by the grid. However, a secondary application can be considered to maximize reactor utilization and avoid ramping down the reactor if the steam demand varies significantly throughout the year. Chilled water generation through steam-driven systems was identified as an attractive secondary option for the site analyzed, due to potential for plant design simplification, while electricity generation could be considered as well to reduce electricity purchases for a wider range of site applications. For a campus with peak 60MW thermal power demand, a small nuclear reactor with similar thermal power rating would almost eliminate CO2 emissions from steam generation and reduce electricity imports for chilled water production. A preliminary techno-economic feasibility study shows that a small nuclear reactor design that is optimized to support process heat can represent an economically feasible option when compared with other decarbonization alternatives.

Stauff, Nicolas E.↗

Performance analysis of novel thermal storage integrated heat pump system in a residential building at the hot climate for demand flexibility

A novel thermal energy storage integrated heat pump system was proposed to reshape the electricity load profile of residential buildings while maintaining thermal comfort. High-fidelity computer simulations are needed for evaluating the feasibility of the proposed system. This study investigates the annual performance of the proposed system through Modelica-based system simulations. A rule-based control strategy was developed to shift the electric demand of a typical single-family house in Atlanta, GA from peak to off-peak hours to utilize the Time-of-Use electricity rate to lower the energy costs for conditioning the building. For comparison, a conventional air-source heat pump system serving the same building was also developed. Simulation results indicate that the proposed system is capable of shifting around 90% of the building's electricity consumption for meeting the thermal demand from peak to off-peak hours on a daily basis. In addition, the annual power consumption and operating cost for running the HVAC system can be reduced by 6% and 34%, respectively, compared with the conventional air-source heat pump.

Shi, Liang↗

Hydrogen Storage for Load-Following and Clean Power: Duct-firing of Hydrogen to Improve the Capacity Factor of NGCC Plants (Final Report, Phase I Conceptual Study)

The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and the proposed system is an improvement over alternate low carbon dispatchable power options. Our demonstration will include 54 MWh of hydrogen storage. CO 2 capture inherent to the CHG process can capture 90% of the CO 2 (with upgrades to >98%) in a commercial system (~300 MWth) for sequestration or other uses. The hydrogen will be utilized in a duct burner in a Heat Recovery Steam Generator (HRSG) integrated with the existing Southern Company fossil asset. Here, the firing rate of the duct burner is varied to let the plant respond to fluctuations of electrical load. However, H 2 production is relatively constant by storing H 2 , and revenues are improved by arbitrage between use of low-cost off-peak variable electricity generation or use of stored H 2 under peak demand. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via system requirements review with the whole team. These requirements were then incorporated into/iterated with our Heat & Mass Balance models and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Our system generates power at 17.4% lower cost than other low carbon approaches for the H 2 generation, H 2 compression and storage, carbon sequestration, and HRSG added electricity production for a large-scale duct-fired system. Our team recommends completing the Phase II Pre-FEED study for the proposed system as the next step for the project and its tasks will achieve the overall objective and be ready to launch the FEED. The Pre-FEED tasks include updating the requirements, Concept of Operations, plant scope/process description, component modeling, system modeling, performance estimates, emission estimates, block flow diagrams, fluid/process conditions (PFD), utility usage, and facility sizing/definition. The approach will be to complete these updates in a greater level of detail for the selected site. The approach for developing the EIV is to use the updated results, including model outputs, for carbon dioxide and waste streams.

03 NATURAL GAS↗

When Do Different Scenarios of Future Electricity Demand Start to Meaningfully Diverge?

Climate and population change are known to influence electricity demand, but what is the impact of uncertainty in climate and population projections on electricity demand in the United States (U.S.) over the next 30 years? This question has important implications for investment decisions in the energy sector, which are typically made using a 15- to 30-year time horizon. Simply put, if future climate and population scenarios do not lead to meteorological conditions and subsequent energy demands that are distinctly different within the first 30 years then, for the purposes of investment decisions, it may not matter which potential pathway we are most likely on. The Integrated, Multisector, Multiscale Modeling (IM3) project has generated a wide, yet plausible range of 21st century high-resolution climate and population scenarios for the U.S. The IM3 projections span two climate scenarios (Representative Concentration Pathways 4.5 and 8.5) and two population scenarios (Shared Socioeconomic Pathways 3 and 5). For each of the climate scenarios, we reflect a range of climate model uncertainty by using boundary conditions from a set of climate models that are hotter and colder than the multi-model mean. In total there are eight (2 x 2 x 2) IM3 scenarios. This work explores a basic question: When do future climate and energy outcomes start to meaningfully diverge across the eight scenarios? The analysis is done on both the raw meteorology time-series from each scenario as well as a time-series of projected total electricity demand generated using IM3's Total ELectricity Loads (TELL) model. We also explore the spatial heterogeneity of the divergence signal to identify regions of the country that may be more or less path dependent.

Climate Change↗

Nuclear's Role in the U.S. Electricity System: A Multi-Model Inter-Comparison Analysis

Multiple capacity expansion models (CEMs) for the U.S. power system represent the balance of options among generation, transmission, and storage assets that can satisfy electric loads, operating and planning reserves, and policy requirements. These models are typically set up to find the least-cost portfolio of assets that meet specified requirements, and model decisions can include both investments in new, and retirement of existing, resources. The scenarios explored by CEMs can help inform strategies for meeting future electricity and energy needs under a range of future conditions. However, projections can differ between models, sometimes dramatically, for a seemingly similar scenario. Differences in model coverage, structure, and input assumptions contribute to the range of model outcomes. Understanding what drives the biggest differences in model outputs improves model insights and provides context for interpreting results. This summary presents analysis that was performed through a forum of analysts who own, update, and apply CEMs, as well as nuclear experts from national laboratories, industry, and the research community. The following sections describe methods, results, and findings from an original, innovative inter-model comparison that provides insights into what drives the greatest differences in nuclear retirement and deployment projections across models and a range of technology, market, and policy conditions.

capacity expansion model↗

Assessing concurrent effects of climate change on hydropower supply, electricity demand, and greenhouse gas emissions in the Upper Yangtze River Basin of China

Hydropower importantly provides flexible low-carbon electricity, however, climate change will affect the hydropower system through altering hydrologic regimes while also affecting electricity demands for heating and cooling that hydropower resources serve. This study assesses the effect of climate change on hydropower and electricity demand in the Upper Yangtze River Basin (UYRB) in China on the regional net electric load and greenhouse gas (GHG) emissions. This is accomplished by using climate projections from five global climate models (GCMs) to simultaneously force (1) a physically-based hydrological model and a statistically-based hydropower model to estimate the future generating capacity of 21 large hydropower plants in the UYRB and (2) an empirical electricity demand model accounting for socioeconomic and climatic factors. Under climate change, the projected hydropower generation in the UYRB tends to increase in the 21st century but is far less than the increase in electricity demand, increasing the gap between demand and supply. Future increases in overall electricity demand are driven by GDP growth, but climate change will alter the distribution of the seasonal electricity demand. Climate warming decreases electricity demand for heating in winter and increases electricity demand for cooling in summer, but ultimately increases demand. Meanwhile, there is an increasing mismatch between electricity demand and hydropower supply associated with inter- and intra-annual variations, owing to the temporal climate change and increase in compound climate extremes (droughts and heatwaves). Finally, meeting the gap between supply and demand due to climate change is estimated to contribute 79.0–184.6 and 50.6–316.2 MMT CO 2e /yr of additional GHG emissions by the mid and end of 21st century, respectively.

13 HYDRO ENERGY↗

Quantifying the Financial Impacts of Electric Vehicles on Utility Ratepayers and Shareholders [Slides]

Widespread electric vehicle (EV) adoption is critical for meeting economy-wide decarbonization goals and, as a result, states are considering enabling policies and rate designs to accelerate EV deployment. EVs can provide possible financial upside to electric utilities and ratepayers in several ways. For example, from the utility perspective, EVs could drive increased electricity sales and new earnings opportunities through increased capital investments. From the ratepayer perspective, increased electric loads from EVs could reduce average all-in retail rates. The degree to which there are net benefits or costs to shareholders and/or ratepayers depends on how EVs are integrated and managed through enabling grid investments and charging strategies. Using Berkeley Lab’s Financial Impacts of Distributed Energy Resources (FINDER) model that mimics the electric utility investment planning and ratemaking processes, we estimate the utility earnings and customer rate impacts of EVs using a bookend approach of “managed” (i.e., best case) and “mismanaged” (i.e., worst case) charging strategies for a generic summer-peaking, investor-owned, and vertically integrated utility. The analysis also examines the sensitivity of results to different assumptions of EV deployment characteristics, EV impacts on retail electricity sales, incremental distribution system costs, EV charging location, and utility EV enablement costs (i.e., utility costs to invest in EV charging, controls, and communication to deliver and administer EV programs). The results are intended to inform EV policies and deployment strategies that maximize utility system benefits and minimize ratepayer costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Potential for Electrons to Molecules Using Solar Energy

Solar photovoltaics (PV) do and will continue to play an important role in the electric power sector and can potentially support other sectors that are in need of decarbonized energy sources. Chemicals such as hydrogen, ammonia, and hydrocarbons including ethylene are currently produced from natural gas and crude oil. Thus, processes to produce them emit carbon dioxide and other greenhouse gases both directly and in upstream feedstock recovery processes. Electrons-to-molecules (E2M) technologies are being developed to convert carbon dioxide, water, and atmospheric nitrogen to desired chemical products and they are large electricity loads. Thus, they are emerging as a potential applications for PV. In its essence, they can act as electrochemical energy storage, thereby providing a means to further utilize the energy generated from PV and store it in molecular form. E2M systems offer an array of potential products and system designs that can be tailored to different end-uses and applications. It involves electrochemical conversion which uses electricity to break molecular bonds and produce new molecules. Various electrochemical conversion technologies split water into hydrogen and oxygen, reduce carbon dioxide into other hydrocarbon molecules, and several other possible combinations. While this Chapter does not attempt to provide an exhaustive summary or analysis of the potential products from E2M systems, it does provide an initial overview of the potential opportunities and challenges for PV and E2M systems in this space. This Chapter considers the potential for E2M to produce key chemicals and fuels that currently rely on hydrocarbons for production, either as a reactant or a source of high-grade heat.

14 SOLAR ENERGY↗

System Assessment of a High Power 3-U CubeSat

The Advanced eLectrical Bus (ALBus) CubeSat project is a technology demonstration mission of a 3-UCubeSat with an advanced, digitally controlled electrical power system capability and novel use of Shape Memory Alloy (SMA) technology for reliable deployable solar array mechanisms. The objective of the project is to, through an on orbit demonstration, advance the state of power management and distribution (PMAD) capabilities to enable future missions requiring higher power, flexible and reliable power systems. The goals of the mission include demonstration of: 100 Watt distribution to a target electrical load, efficient battery charging in the orbital environment, flexible power system distribution interfaces, adaptation of power system control on orbit, and reliable deployment of solar arrays and antennas utilizing re-settable SMA mechanisms. The power distribution function of the ALBus PMAD system is unique in the total power to target load capability of 100 W, the flexibility to support centralized or point-to-load regulation and ability to respond to fast transient power requirements. Power will be distributed from batteries at 14.8 V, 6.5 A to provide 100 W of power directly to a load. The deployable solar arrays utilize NASA Glenn Research Center superelastic and activated Nitinol(Nickel-Titanium alloy) Shape Memory Alloy (SMA) technology for hinges and a retention and release mechanism. The deployable solar array hinge design features utilization of the SMA material properties for dual purpose. The hinge uses the shape memory properties of the SMA to provide the spring force to deploy the arrays. The electrical conductivity properties of the SMA also enables the design to provide clean conduits for power transfer from the deployable arrays to the power management system. This eliminates the need for electrical harnesses between the arrays and the PMAD system in the ALBus system design. The uniqueness of the SMA retention and release mechanism design is the ability to reset the mechanism, allowing functional tests of the mechanisms prior to flight with no degradation of performance. The project is currently in preparation at the NASA Glenn Research Center for a launch in late calendar year of 2017. The 100 Watt power distribution and dual purpose, re-settable SMA mechanisms introduced several system level challenges due to the physical constraints in volume, mass and surface area of 3-U CubeSats. Several trade studies and design cycles have been completed to develop a system which supports the project objectives. This paper is a report on the results of the system level trade studies and assessments. The results include assessment of options for thermal control of 100 Watts of power dissipation, data from system analyses and engineering development tests, limitations of the 3-U system and extensibility to larger scale CubeSat missions.

CubeSat↗

Stochastic simulation of occupant-driven energy use in a bottom-up residential building stock model

The residential buildings sector is one of the largest electricity consumers worldwide and contributes disproportionally to peak electricity demand in many regions. Strongly driven by occupant activities, household energy consumption is stochastic and heterogeneous in nature. However, most residential energy models applied by industry use homogeneous, deterministic activity schedules, which work well for predictions of annual energy consumption, but can result in unrealistic hourly or sub-hourly electric load profiles, with exaggerated or muted peaks. The increasing proportion of variable renewable energy generators means that representing the heterogeneity and stochasticity of occupant behavior is now crucial for reliable planning at both bulk-power and distribution-system scales. This work presents a novel and open-source occupancy simulation approach that can simulate a diverse set of individual occupant and household event schedules for all major electricity, fuel, and hot water end uses. To accomplish this, we evaluated three alternative occupant activity simulation approaches before selecting a hybrid combining time-inhomogeneous Markov chains and probability-sampling of event durations and magnitudes. Further, we integrated the stochastic occupancy simulation with an open-source bottom-up physics-simulation building stock model and published a set of 550,000 diverse household end-use activity schedules representing a national housing stock. The simulator was verified against time-use survey data, and simulation results were validated against measured end-use electricity data for accuracy and reliability. While we use data for the United States, our application demonstrates how similar approaches could be applied using the time-use survey data collected in many countries around the world.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗