Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “effect measure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Correlation of Coronal Plasma Properties and Solar Magnetic Field in a Decaying Active Region

We present the analysis of a decaying active region observed by the EUV Imaging Spectrometer on Hinode during 2009 December 7-11. We investigated the temporal evolution of its structure exhibited by plasma at temperatures from 300,000 to 2.8 million degrees, and derived the electron density, differential emission measure, effective electron temperature, and elemental abundance ratios of Si/S and Fe/S (as a measure of the First Ionization Potential (FIP) Effect). We compared these coronal properties to the temporal evolution of the photospheric magnetic field strength obtained from the Solar and Heliospheric Observatory Michelson Doppler Imager magnetograms. We find that, while these coronal properties all decreased with time during this decay phase, the largest change was at plasma above 1.5 million degrees. The photospheric magnetic field strength also decreased with time but mainly for field strengths lower than about 70 Gauss. The effective electron temperature and the FIP bias seem to reach a basal state (at 1.5 x 10(exp 6) K and 1.5, respectively) into the quiet Sun when the mean photospheric magnetic field (excluding all areas <10 G) weakened to below 35 G, while the electron density continued to decrease with the weakening field. These physical properties are all positively correlated with each other and the correlation is the strongest in the high-temperature plasma. Such correlation properties should be considered in the quest for our understanding of how the corona is heated. The variations in the elemental abundance should especially be considered together with the electron temperature and density.

Sun: abundances↗

The effects of vegetation cover on the radar and radiometric sensitivity to soil moisture

The measured effects of vegetation canopies on radar and radiometric sensitivity to soil moisture are compared to emission and scattering models. The models are found to predict accurately the measured emission and backscattering for various crop canopies at frequencies between 1.4 and 5.0 GHz, especially at theta equal to or less than 30 deg. Vegetation loss factors, L(theta), increase with frequency and are found to be dependent upon canopy type and water content. In addition, the radiometric power absorption coefficient of a mature corn canopy is 1.75 times that calculated for the radar. Comparison of an L-band radiometer with a C-band radar shows the two systems to be complementary in terms of accurate soil moisture sensing over the extreme range of naturally occurring soil moisture conditions.

Ulaby, F. T.↗

Influence of Chair Vibrations on Indoor Sonic Boom Annoyance

One goal of NASA’s Commercial Supersonic Technology Project is to identify candidate noise metrics suitable for regulating quiet sonic boom aircraft. A suitable metric must consider the short duration and pronounced low frequency content of sonic booms. For indoor listeners, rattle and creaking sounds and floor and chair vibrations may also be important. The current study examined the effect of such vibrations on the annoyance of test subjects seated indoors. The study involved two chairs exposed to nearly identical acoustic levels: one placed directly on the floor, and the other isolated from floor vibrations by pneumatic elastomeric mounts. All subjects experienced both chairs, sitting in one chair for the first half of the experiment and the other chair for the remaining half. Each half of the experiment consisted of 80 impulsive noises played at the exterior of the sonic boom simulator. When all annoyance ratings were analyzed together there appeared to be no difference in mean annoyance with isolation condition. When the apparent effect of transfer bias was removed, a subtle but measurable effect of vibration on annoyance was identified.

Rathsam, Jonathan↗

Low-Speed Flow Studies Using the Pressure Sensitive Paint Technique

Optical pressure measurements have been made on a NACA 0012 airfoil coated with Pressure Sensitive Paint (PSP) at very low flow speeds (less than 50 m/s). Angle of attack was limited to 5 deg. for most measurements. Effects of temperature gradients and mis-registration errors on PSP response have been established and minimized. By reducing measurement error caused by these effects. PSP sensitivity has been enhanced. Acceptable aerodynamic data at flow speeds down to 20 m/s have been obtained and valid pressure paint response was observed down to 10 m/s. Measurement errors (in terms of pressure and pressure coefficient) using PSP with pressure taps as a reference are provided for the range of flow speeds from 50 m/s to 10 m/s.

Brown, O. C.↗

Prediction and measurement of radiation damage to CMOS devices on board spacecraft

The CMOS Radiation Effects Measurement (CREM) experiment is presently being flown on the Explorer-55. The purpose of the experiment is to evaluate device performance in the actual space radiation environment and to correlate the respective measurements to on-the-ground laboratory irradiation results. The experiment contains an assembly of C-MOS and P-MOS devices shielded in front by flat slabs of aluminum and by a practically infinite shield in the back. Predictions of radiation damage to C-MOS devices are based on standard environment models and computational techniques. A comparison of the shifts in CMOS threshold potentials, that is, those measured in space to those obtained from the on-the-ground simulation experiment with Co-60, indicates that the measured space damage is smaller than predicted by about a factor of 2-3 for thin shields, but agrees well with predictions for thicker shields.

Cliff, R. A.↗

Prediction and measurement of radiation damage to CMOS devices on board spacecraft

The CMOS Radiation Effects Measurement (CREM) experiment is presently being flown on the Explorer-55, to evaluate device performance in the actual space radiation environment and to correlate the respective measurements to on-the-ground laboratory irradiation results. The experiment contains an assembly of CMOS and P-MOS devices shielded in front over 2 pi steradian by flat slabs of aluminum of 40, 80, 150, and 300 mils (1.02, 2.04, 3.81, and 7.62 mm) thicknesses, and by a practically infinite shield in the back. Initial results from the CREM experiment are reported. Predictions of radiation damage to CMOS devices are based on standard environment models and computational techniques. Measured space damage is smaller than predicted by about a factor of 2-3 for thin shields but agrees well with predictions for thicker shields. It is not clear at this time how the trapped particle environment models or the computational methods should be modified in order to achieve better agreement between experimental results and predicted damage curves.

Cliff, R. A.↗

Prediction and measurement results of radiation damage to CMOS devices on board spacecraft

Final results from the CMOS Radiation Effects Measurement (CREM) experiment flown on Explorer 55 are presented and discussed, based on about 15 months of observations and measurements. Conclusions are given relating to long-range annealing, effects of operating temperature on semiconductor performance in space, biased and unbiased P-MOS device degradation, unbiased n-channel device performance, changes in device transconductance, and the difference in ionization efficiency between Co-60 gamma rays and 1-Mev Van de Graaff electrons. The performance of devices in a heavily shielded electronic subsystem box within the spacecraft is evaluated and compared. Environment models and computational methods and their impact on device-degradation estimates are being reviewed to determine whether they permit cost-effective design of spacecraft.

Stassinopoulos, E. G.↗

Faster Hall-Effect Current-Measuring Circuit

Current-measuring circuit operates on Hall-effect-sensing and magnetic-field-nulling principles similar to those described in article, "Nulling Hall-Effect Current-Measuring Circuit" (LEW-15023), but simpler and responds faster. Designed without feedback loop, and analog pulse-width-modulated output indicates measured current. Circuit measures current at frequency higher than bandwidth of its Hall-effect sensor.

Sullender, Craig C.↗

Effective defect density for MOS breakdown - Dependence on oxide thickness

A new procedure for measuring effective defect density takes time-dependent primary dielectric breakdown in MOS devices into account. A time-varying breakdown probability is obtained by applying a constant field stress to a statistically sufficient number of MOS capacitors. Effective defects are assumed distributed randomly in two dimensions, hence indistinguishable. The effective defect density is found to vary with oxide thickness; tentative explanations are ventured to account for this (interfacial tensile stress, ion patching enhanced by local trapping, breakdown in the form of filamentary discharges with release of stored electrostatic energy).

Li, S. P.↗

Apparatus and Methods for Photoacoustic Measurement of Light Absorption of Particulate and Gaseous Species

In one embodiment, a photoacoustic effect measurement instrument for measuring a species (e.g., a species of PM) in a gas employs a pair of differential acoustic cells including a sample cell that receives sample gas including the species, and a reference cell that receives a filtered version of the sample gas from which the species has been substantially removed. An excitation light source provides an amplitude modulated beam to each of the acoustic cells. An array of multiple microphones is mounted to each of the differential acoustic cells, and measures an acoustic wave generated in the respective acoustic cell by absorption of light by sample gas therein to produce a respective signal. The microphones are isolated from sample gas internal to the acoustic cell by a film. A preamplifier determines a differential signal and a controller calculates concentration of the species based on the differential signal.

Yu, Zhenhong↗

Quantum Zeno Effect in the Measurement Problem

Critically analyzing the so-called quantum Zeno effect in the measurement problem, we show that observation of this effect does not necessarily mean experimental evidence for the naive notion of wave-function collapse by measurement (the simple projection rule). We also examine what kind of limitation the uncertainty relation and others impose on the observation of the quantum Zeno effect.

Namiki, Mikio↗

Measuring Gap Fraction, Element Clumping Index and LAI in Sierra Forest Stands Using a Full-Waveform Ground-Based Lidar

The Echidna Validation Instrument (EVI), a ground-based, near-infrared (1064 nm) scanning lidar, provides gap fraction measurements, element clumping index measurements, effective leaf area index (LAIe) and leaf area index (LAI) measurements that are statistically similar to those from hemispherical photos. In this research, a new method integrating the range dimension is presented for retrieving element clumping index using a unique series of images of gap probability (Pgap) with range from EVI. From these images, we identified connected gap components and found the approximate physical, rather than angular, size of connected gap component. We conducted trials at 30 plots within six conifer stands of varying height and stocking densities in the Sierra National Forest, CA, in August 2008. The element clumping index measurements retrieved from EVI Pgap image series for the hinge angle region are highly consistent (R2=0.866) with those of hemispherical photos. Furthermore, the information contained in connected gap component size profiles does account for the difference between our method and gap-size distribution theory based method, suggesting a new perspective to measure element clumping index with EVI Pgap image series and also a potential advantage of three dimensional Lidar data for element clumping index retrieval. Therefore further exploration is required for better characterization of clumped condition from EVI Pgap image series.

Zhao, Feng↗

Static and wind tunnel near-field/far-field jet noise measurements from model scale single-flow base line and suppressor nozzles. Summary report

A test program was conducted in the Boeing large anechoic test chamber and the NASA-Ames 40- by 80-foot wind tunnel to study the near- and far-field jet noise characteristics of six baseline and suppressor nozzles. Static and wind-on noise source locations were determined. A technique for extrapolating near field jet noise measurements into the far field was established. It was determined if flight effects measured in the near field are the same as those in the far field. The flight effects on the jet noise levels of the baseline and suppressor nozzles were determined. Test models included a 15.24-cm round convergent nozzle, an annular nozzle with and without ejector, a 20-lobe nozzle with and without ejector, and a 57-tube nozzle with lined ejector. The static free-field test in the anechoic chamber covered nozzle pressure ratios from 1.44 to 2.25 and jet velocities from 412 to 594 m/s at a total temperature of 844 K. The wind tunnel flight effects test repeated these nozzle test conditions with ambient velocities of 0 to 92 m/s.

Jaeck, C. L.↗

Using a focal-plane array to estimate antenna pointing errors

The use of extra collecting horns in the focal plane of an antenna as a means of determining the Direction of Arrival (DOA) of the signal impinging on it, provided it is within the antenna beam, is considered. Our analysis yields a relatively simple algorithm to extract the DOA from the horns' outputs. An algorithm which, in effect, measures the thermal noise of the horns' signals and determines its effect on the uncertainty of the extracted DOA parameters is developed. Both algorithms were implemented in software and tested in simulated data. Based on these tests, it is concluded that this is a viable approach to the DOA determination. Though the results obtained are of general applicability, the particular motivation for the present work is their application to the pointing of a mechanically deformed antenna. It is anticipated that the pointing algorithm developed for a deformed antenna could be obtained as a small perturbation of the algorithm developed for an undeformed antenna. In this context, it should be pointed out that, with a deformed antenna, the array of horns and its associated circuitry constitute the main part of the deformation-compensation system. In this case, the pointing system proposed may be viewed as an additional task carried out by the deformation-compensation hardware.

Zohar, S.↗

Advanced AE Techniques in Composite Materials Research

Advanced, waveform based acoustic emission (AE) techniques have been successfully used to evaluate damage mechanisms in laboratory testing of composite coupons. An example is presented in which the initiation of transverse matrix cracking was monitored. In these tests, broad band, high fidelity acoustic sensors were used to detect signals which were then digitized and stored for analysis. Analysis techniques were based on plate mode wave propagation characteristics. This approach, more recently referred to as Modal AE, provides an enhanced capability to discriminate and eliminate noise signals from those generated by damage mechanisms. This technique also allows much more precise source location than conventional, threshold crossing arrival time determination techniques. To apply Modal AE concepts to the interpretation of AE on larger composite specimens or structures, the effects of modal wave propagation over larger distances and through structural complexities must be well characterized and understood. To demonstrate these effects, measurements of the far field, peak amplitude attenuation of the extensional and flexural plate mode components of broad band simulated AE signals in large composite panels are discussed. These measurements demonstrated that the flexural mode attenuation is dominated by dispersion effects. Thus, it is significantly affected by the thickness of the composite plate. Furthermore, the flexural mode attenuation can be significantly larger than that of the extensional mode even though its peak amplitude consists of much lower frequency components.

Prosser, William H.↗

The hidden ion population - Revisited

In an investigation conducted by Olsen (1982) on the basis of particle data taken with an electrostatic analyzer, it was found that a cold plasma population with a density between 10 and 100 per cu cm appeared suddenly when the satellite was eclipsed, but was hidden in sunlight. The present paper has the objective to show further measurements of ordinarily 'hidden' ion populations, in order to resolve some of the questions raised in connection with the Scatha satellite data reported by Olsen. It is found that the retarding ion mass spectrometer (RIMS) detector is capable of measuring the core of the plasma distribution in sunlight and eclipse, though the task is more easily done in eclipse. There are, however, limitations concerning the ability of the detector to measure all the plasma, all the time. It is, therefore, pointed out that continuous effective measurements of the 'hidden' ion population of the magnetosphere still awaits satellites with effective means of potential control.

Olsen, R. C.↗

Characterization of the transport properties of channel delta-doped structures by light-modulated Shubnikov-de Haas measurements

The transport properties of channel delta-doped quantum well structures were characterized by conventional Hall effect and light-modulated Shubnikov-de Haas (SdH) effect measurements. The large number of carriers that become available due to the delta-doping of the channel, leads to an apparent degeneracy in the well. As a result of this degeneracy, the carrier mobility remains constant as a function of temperature from 300 K down to 1.4 K. The large amount of impurity scattering, associated with the overlap of the charge carriers and the dopants, resulted in low carrier mobilities and restricted the observation of the oscillatory magneto-resistance used to characterize the two-dimensional electron gas (2DEG) by conventional SdH measurements. By light-modulating the carriers, we were able to observe the SdH oscillation at low magnetic fields, below 1.4 tesla, and derive a value for the quantum scattering time. Our results for the ratio of the transport and quantum scattering times are lower than those previously measured for similar structures using much higher magnetic fields.

Mena, R. A.↗