Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “droop control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

173 records · Page 10

A Frequency Control Method for Islanded Microgrids Using Energy Storage Systems

Islanded microgrids are vulnerable to frequency fluctuations due to the presence of low-inertia distributed energy resources (DERs). Moreover, implementation of both synchronous-based and inverter-based DERs with a significant difference in inertia leads to a power imbalance between generation and consumption during transients. This results in frequency variations which might have severe consequences such as blackouts. This paper develops a control scheme for battery energy storage systems (BESSs) to enhance the dynamic response of islanded microgrids by mitigating the frequency fluctuations. A piecewise linear-elliptic (PLE) droop characteristic is proposed and employed in BESS to achieve a faster power balance between generation and consumption during transients, resulting in enhanced frequency responses. Different case studies are carried out to validate the viability of the proposed approach in improving the dynamics of islanded microgrids.

Pilehvar, Mohsen S.↗

Development of a Hardware-in-The-Loop Testbed for a Decentralized, Data-Driven Electric Vehicle Charging Control Algorithm

This study presents the design of an electric vehicle (EV)-grid integration (EVGI) hardware test-bed to implement smart EV charging algorithms. Here, the proposed test-bed also allows to create different grid events via flexible integration of other power hardware (e.g., controllable loads and battery energy storage systems) and test their impacts on EV charging. The design uses a real-time digital simulator to realize a complex distribution grid model with primary and secondary networks. A grid simulator physically realizes the selected nodes of the simulated grid to power an actual EV, forming a hardware-in-the-loop (HIL) test setup. The EV-grid integration is demonstrated based on the custom hardware and software implementation of the J1772 charging protocol using dSPACE MicroLabBox, operating as a custom EV Supply Equipment (EVSE). The HIL test-bed features a novel testing platform for accurate implementation and analysis of scalable charging algorithms. To this end, a data-driven, decentralized, model-free charging controller based on the Additive Increase and Multiplicative Decrease (AIMD) algorithm is presented and validated on an EV using the HIL test-bed. We tested the proposed algorithm under various case studies, and presented a comparison study with an existing droop-based, decentralized charging solution. The results showed that the EV successfully performed charging commands generated by the EVSE and regulated its charging power to effectively reduce the system loading caused by high EV penetration.

33 ADVANCED PROPULSION SYSTEMS↗

Energy-Storage Fed Smart Inverters for Mitigation of Voltage Fluctuations in Islanded Microgrids

The continuous integration of intermittent low-carbon energy resources makes islanded microgrids vulnerable to voltage fluctuations. Besides, different dynamic response of synchronous-based and inverter-based distributed generation (DG) units can result in an instantaneous power imbalance between supply and demand during transients. As a result, the ac-bus voltage of microgrid starts oscillating which might have severe consequences such as blackouts. This paper modifies the conventional control scheme of battery energy storage systems (BESSs) to participate in improving the dynamic behavior of islanded microgrids by mitigating the voltage fluctuations. A piecewise linear-elliptic (PLE) droop is proposed and employed in BESS to achieve an enhanced voltage profile by injecting/absorbing reactive power during transients. In this way, the conventional inverter implemented in BESS turns into a smart inverter to cope with fast transients. Using the proposed approach in this paper, any linear droop curve with a specified coefficient can be replaced by a PLE droop curve. Compared with linear droop, an enhanced dynamic response is achieved by utilizing the proposed PLE droop. Case study results are presented using PSCAD/EMTDC to demonstrate the superiority of the proposed approach in improving the dynamic behavior of islanded microgrids.

Pilehvar, Mohsen S.↗

An 802pW 93% Peak Efficiency Buck Converter with 5.5×10 6 Dynamic Range Featuring Fast DVFS and Asynchronous Load-Transient Control

Here this paper presents a buck converter with sub-nW quiescent power, high efficiency, and a wide dynamic range for ultra-low-power (ULP) IoT SoCs. To optimize the SoC power consumption, the buck converter supports fast dynamic voltage and frequency scaling (DVFS) and enables fast load-transient response (FLTR) through asynchronous control. In addition, the buck converter is fully self-contained with all features integrated on chip including a proposed adaptive deadtime controller. Fabricated in 65nm CMOS, measurement results show the buck converter has an 802pW quiescent power at 1.5V input voltage and a 93% peak efficiency. The measured dynamic range is from 0.5nW to 2.75mW, which is over 6 orders of magnitude. The measured voltage droop is 54mV for a 45nA-to-1mA load current step thanks to the asynchronous load-transient detector. The buck converter achieves the highest efficiency and widest dynamic range among all the state-of-the-art sub-nW switching voltage regulators, which makes it well suited for power management in ULP SoCs.

42 ENGINEERING↗

Grey-Box System Identification of Grid-Forming Inverters

This paper demonstrates the use of grey-box system identification methods for simplifying and understanding the nonlinear power dynamics of grid-forming inverters (GFMs). The power and frequency outputs of complex high-order GFM models are fed into system identification software in order to fit them to a predetermined LTI system and learn system parameters such as (synthetic) inertia and droop constants. The same process is then run for a high-order synchronous generator model, and the outputs are fit to the same set of LTI equations. Simulation of a network of GFM inverters with diverse control architecture is also performed for the same process. The intent is threefold: first, to demonstrate the appropriateness of unified LTI models for describing the power and frequency dynamics of individual resources and connected networks, in order to facilitate analysis of larger heterogeneous networked systems; second, to discover the relationship between internal control parameters of GFMs and their externally observed values; and third, to validate that grey-box data-driven system identification techniques can be a valuable tool to discover the values of important parameters in the absence of explicit vendor models.

analytical models↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation: Preprint

Existing real-world projects of GFM inverters that operate in parallel to power grids typically are sized between dozens and a few hundreds Megawatt (MW) scale according to a recent NERC GFM inverter white paper. These large systems are often difficult to evaluate prior to deployments because of their large size. The performance of smaller GFM inverters (dozens to a few hundreds MW) that operate parallel with power grids (distribution systems) is even less understood. There is an opportunity to better understand these systems through hardware testing under controlled laboratory conditions. Therefore, this paper presents the functional performance evaluation tests of multiple (three) commercial GFM inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore the GFM inverters' functionalities and dynamic response when in parallel with power grids to eventually develop universal specifications for GFM inverters. Both steady state (changing the inverter's frequency and voltage droop) and transient (adding step change in grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The experimental results indicate the bench-marked performance that: 1) the GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power when paralleled to the grid; 2) the GFM inverters automatically respond to system frequency and voltage events to output the needed power, however, the GFM inverters all show stability issues when absorbing reactive power from the grid.

grid-forming inverters↗

Unleashing the Frequency: Multi-Megawatt Demonstration of 100% Renewable Power Systems with Decentralized Communication-Less Control Scheme

Power systems, which range in size from small microgrids to island systems to large regional grids, are typically managed by a central controller that requires complex communication methods and can be unreliable and pose cyber security risks in certain applications, especially when controlling a larger number of nodes. We propose an inherently robust, scalable method of integration using multiple energy storage systems and distributed energy resources, which does not require any means of dedicated communication. This method moves beyond the paradigm of controlling grid frequency at a fixed value (e.g., 60 Hz), instead allowing the frequency to fluctuate within certain limits (e.g., 59.6-60.4 Hz). With a greater operating range, the frequency can carry necessary information from energy storage systems to highly variable distributed energy resources like photovoltaics, wind, hydro, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Autonomous Voltage Response for Distributed Energy Resources

An implementation of stable droop voltage response for distributed energy resources (DER) is described. The key point is to use a new “autonomously adjusting reference voltage” as described in IEEE Standard 1547-2018. Examples include battery voltage response, a photovoltaic inverter at the end of a long secondary circuit, and 18 photovoltaic inverters on a distribution lateral. Default inverter settings are proposed for DER that would mitigate voltage fluctuations, with or without communications.

Automatic voltage control, distributed power gener↗

Operando Temperature Measurements of Photovoltaic Laser Power Converter Devices Under Continuous High-Intensity Illumination

Photovoltaic devices that operate under extremely high irradiances, such as laser power converters (LPCs), may also operate at elevated temperatures, even under active cooling, as the result of large temperature gradients. We demonstrate the operation of GaAs LPC devices under orders of magnitude of irradiances up to 150 W/cm 2 in a monochromatic laser simulator with an active cooling stage. The steady-state open-circuit voltage (V OC ) as a function of irradiance is known to droop at high irradiance as the result of junction heating, but the junction temperature can be difficult to measure by conventional methods. Fast, transient V OC measurements under these extreme operating conditions are used here to determine the junction temperature. Empirical V OC temperature coefficients of the devices at each irradiance of interest are determined and used as an integral part of this technique. We show that the thermal design of different LPC devices strongly affects the operating temperature of the junctions. Knowledge of the operating temperature can be a strong tool for understanding the nature of loss mechanisms and improving the design for the operation of photovoltaic LPCs at high irradiances. Furthermore, this technique can be used for laboratory devices during initial design as well as to characterize mass-produced and packaged devices for quality control.

14 SOLAR ENERGY↗

Impedance Analysis and PHIL Demonstration of Reactive Power Oscillations in a Wind Power Plant Using a 4-MW Wind Turbine

This paper presents impedance-based analysis, mitigation, and power-hardware-in-the-loop (PHIL) demonstration of reactive power oscillations in a wind power plant using a 4-MW Type III wind turbine drivetrain. Because such low-frequency oscillations result from interactions among slower control loops of wind turbines regulating phasor quantities—active and reactive power output of the wind turbine and the magnitude of voltages at the point of interconnection (POI)—a new type of admittance is defined in terms of phasor quantities for their analysis. The so-called power-domain admittance of a wind turbine is defined as the transfer function from the frequency and magnitude of voltages at the POI to the active and reactive power output of the turbine. The power-domain admittance responses of the 4-MW wind turbine are measured using a 7-MVA grid simulator to identify the source of the reactive power oscillations. Power-domain impedance analysis and PHIL experiments are performed to explain how a resonant mode manifests as turbine-to-turbine and plant-to-grid reactive power oscillations. It is discovered that weaker grids exhibiting high inductive impedance mitigate oscillations in the reactive power output of wind power plants; however, a higher grid impedance does not help in damping turbine-to-turbine reactive power oscillations. This paper presents a simple droop-based solution to eliminate both turbine-to-turbine and plant-to-grid reactive power oscillations.

17 WIND ENERGY↗

Investigation of Superluminescent Diodes for Smart Lighting Systems. Final Report

The solid-state lighting ecosystem has evolved very rapidly over the last few years, with significant improvements in the technical performance of light-emitting diodes (LEDs) and the commoditization of LED-based lighting fixtures. As the performance of conventional lighting products begins to saturate, there is growing market interest in “Lighting as a Service” applications that will leverage advanced systems to impart new functionalities to lighting and improve energy efficiency, human health, and productivity. These “Smart Lighting” systems will include high-performance light sources, specialized sensors, and dynamic controls to deliver high quality, energy efficient, color tunable lighting with customized spatial light delivery and integrated visible light communication capability. To achieve these capabilities, smart lighting systems will place greater demands on the performance of light sources. Highly efficient sources with additional functionalities compared to conventional LEDs, such as small form factor, large modulation bandwidth, and spatially coherent output beams, will be required. While laser diodes have been proposed as potential sources for smart lighting systems, they also exhibit several properties that pose challenges, such as temporal coherence, extremely high spatial coherence, and ultra-narrow linewidths. To address these issues, we propose an investigation of an alternative device architecture known as a superluminescent diode (SLD). SLDs are similar in form to ridge laser diodes and share many of the same characteristics, such as stimulated emission operation, spatially coherent output, small form factor, and the potential for large modulation bandwidth. However, the operating principle for SLDs is distinct from laser diodes in that SLDs lack a strong cavity feedback mechanism, resulting in spatially coherent but temporally incoherent light output. Thus, SLDs may address the issues with laser diodes for lighting, while simultaneously maintaining some of the desirable characteristics of both laser diodes and LEDs. The objectives of this proposal are to design, grow, and fabricate blue (450 nm) SLDs on polar c-plane and nonpolar m-plane free-standing GaN substrates, and to evaluate their potential as sources in smart lighting systems through basic device characterization and detailed investigations of their efficiency droop and modulation bandwidth. The primary scientific aims of this work are to understand the fundamental role of optical gain in the superluminescent (non-lasing) regime on efficiency droop and modulation bandwidth in III-nitride emitters and to understand the effects of higher optical gain on SLD performance by comparing polar c-plane and nonpolar m-plane SLDs. The University of New Mexico (UNM) will collaborate with Sandia National Laboratories (SNL) and the Center for Integrated Nanotechnologies to design, fabricate, grow, and characterize the SLDs. UNM will perform the design and epitaxial growth, while SNL will focus on the fabrication and device characterization. The novelty of the proposed work includes the first comprehensive theoretical and experimental investigations of efficiency droop and the first investigation of modulation bandwidth in GaN-based emitters operating in the superluminescent regime. Moreover, the comparison of c-plane and m-plane SLDs will enable the first analysis of the effects of higher optical gain on the device performance. The development of high-performance GaN-based SLDs may enable efficiency gains and improved functionality in next-generation smart lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗